• Title/Summary/Keyword: 이온에너지분포

Search Result 152, Processing Time 0.035 seconds

Modeling of the dynamic behavior of a 12-V automotive lead-acid battery (12V 차량용 납축전지의 동적 거동 모델링)

  • Kim, Sung Tae;Lee, Jeong Bin;Kim, Ui Seong;Shin, Chee Burm
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.175-183
    • /
    • 2013
  • For the optimal design of the vehicle electric system, it is important to have a reliable modeling tool to predict the dynamic behavior of the automotive battery. In this work, a one-dimensional modeling was carried-out to predict the dynamic behaviors of a 12-V automotive lead-acid battery. The model accounted for electrochemical kinetics and ionic mass transfer in a battery cell. In order to validate the modeling, modeling results were compared with the experiment data of the dynamic behaviors of the lead-acid batteries of two different capacities that were mounted on the automobiles manufactured by Hyundai Motor Company. The discharge behaviors were measured with various discharge rates of C/3, C/5, C/10, C/20 and combination. And dynamic behaviors of charge and discharge were measured. The voltage curves from the experiment and simulation were in good agreement. Based on the modeling, the distributions of the electrical potentials of the solid and solution phases, and the current density within the electrodes could be predicted as a function of charge and discharge time.

Monte Carlo Simulation of a Varian 21EX Clinac 6 MV Photon Beam Characteristics Using GATE6 (GATE6를 이용한 Varian 21EX Clinac 선형가속기의 6 MV X-선 특성모사)

  • An, Jung-Su;Lee, Chang-Lae;Baek, Cheol-Ha
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.571-575
    • /
    • 2016
  • Monte Carlo simulations are widely used as the most accurate technique for dose calculation in radiation therapy. In this paper, the GATE6(Geant4 Application for Tomographic Emission ver.6) code was employed to calculate the dosimetric performance of the photon beams from a linear accelerator(LINAC). The treatment head of a Varian 21EX Clinac was modeled including the major geometric structures within the beam path such as a target, a primary collimator, a flattening filter, a ion chamber, and jaws. The 6 MV photon spectra were characterized in a standard $10{\times}10cm^2$ field at 100 cm source-to-surface distance(SSD) and subsequent dose estimations were made in a water phantom. The measurements of percentage depth dose and dose profiles were performed with 3D water phantom and the simulated data was compared to measured reference data. The simulated results agreed very well with the measured data. It has been found that the GATE6 code is an effective tool for dose optimization in radiotherapy applications.

A Relation between the Electrochemical Behaviors and Morphology of Co3O4 and Ni-Co3O4 Composites as Anode Materials for Li Ion Secondary Batteries (리툼 이차 전지용 Co3O4 및 Ni-Co3O4 복합물의 전기화학적 특성 및 표면 형상의 관계)

  • Kang, Yong-Mook;Lee, Yong-Ju;Song, Min-Sang;Park, Min-Sik;Lee, Jai-Young
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.14 no.3
    • /
    • pp.217-228
    • /
    • 2003
  • Li 이차 전지 음극용 활물질인 $Co_3O_4$의 초기 충방전 효율을 향상시키기 위해 chemical reduction method나 mechanical milling법을 이용하여 $Co_3O_4$에 Ni을 첨가하여 $Ni-Co_3O_4$, 복합물을 제조하였다. 그 결과 초기 충방전 효율이 약 69%에 불과한 $Co_3O_4$에 비해 mechanical milling법을 이용하여 제조된 $Ni-Co_3O_4$ 복합물은 약 79%이상의 대폭 향상된 초기 충방전 효율 특성을 나타내었다. 하지만 chemical reduction method를 이용하여 제조된 $Ni-Co_3O_4$ 복합물은 약 71%의 초기 충방전 효율 특성만을 나타내었다. SEM 분석을 통해 각 물질의 표면 형상을 관찰한 결과 mechanical milling법과 chemical reduction method를 통해 제조된 $Ni-Co_3O_4$ 복합물에서는 $Co_3O_4$ 표면에 분포된 Ni의 균일성의 차이가 존재하였다. $Co_3O_4$$Li_2O$의 분해, 형성에 의해 충방전되고 Ni이 $Li_2O$의 분해를 촉진시키는 효과를 가지고 있음을 고려할 때 이러한 균일성의 차이는 결국 Ni 과 $Co_3O_4$ 사이의 접촉면적의 차이로 이어져 $Ni-Co_3O_4$ 복합물의 초기 충방전 효율 특성이 그 제조 방법에 따라 달라지는 것으로 보인다.

Distribution of Potassium Fractions and Soil Parameters Related to the Potassium Availability of Upland Soils (밭토양(土壤)의 칼륨형태별(形態別) 함량분포(含量分布) 및 칼륨비옥도(肥沃度) 관련지표(關聯指標))

  • Park, Yang-Ho;Ryu, In-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.27 no.3
    • /
    • pp.179-188
    • /
    • 1994
  • This study was conducted to investigate the distribution of potassium fractions and to establish the soil chemical indices for assessing potassium availability in upland soil. Soil samples were collected from 66 vegetable crop fields of Chungbuk Jungweon, Jeonbuk Imsil and Kyengbuk Euiseong and these samples were analyzed water soluble(W. S. -K), exchangeable(Exch. -K) and nonexchangeable potassium(Nonex. -K). The distribution of potassium fractions was examined for soils having different physico-chemical properties and compared with the soil parameters related to the potassium availability. 1. The distribution ranges of W.S.-K, Exch.-K and Nonex.-K were 0.07~1.42, 0.27~2.30, and 0.84~4.74me/100g, and average contents of relevent fractions were 0.40, 1.03 and 2.37me/100g respectively. 2. Contents of W.S.-K and Exch.-K were decreased with increasing soil pH, CEC, Exch. Ca and Exch. Mg contents but Nonex. -K showed a low correlationship with these factors. 3. Exch.-K content slightly inereased with increasing clay content, while W.S.-K and Nonex. -K contents were grandually decreased with clay contents. 4. The relationship between W.S.-K and Exch.-K was significant and W.S.-K was released from soil at 0.23me/100g content of Exch.-K 5. Contents of W.S-K and Exch.-K showed high correlationship with soil chemical parameters such as ratio of exchangeable cations(K/Ca+Mg), ratio of exchangeable cation equivalent[$K/{\sqrt{Ca+Mg}}:(me/100g)^{1/2}$], potassium exchangeable free energy(${\Delta}F=RT$ 1n $K/{\sqrt{Ca+Mg}}$ : calories/mole) and saturation percentage of potassium($Exch.K/CEC{\times}100$), and these factors were considered to be good parameters for assessing soil potassium availability.

  • PDF

Quantitative Evaluation of Gated Radiation Therapy Using Gamma Index Analysis (감마지표 분석을 통한 호흡연동방사선치료의 정량적 평가)

  • Ma, Sun Young;Choi, Ji Hoon;Jeung, Tae Sig;Lim, Sangwook
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.198-203
    • /
    • 2013
  • Generally, to evaluate gated radiation therapy, moving phantoms are used to simulate organ motion. Since the target moves in every direction, we need to take into account motion in each direction. This study proposes methods to evaluate gated radiation therapy using gamma index analysis and to visualize adequate gating window sizes according to motion ranges. The moving phantom was fabricated to simulate motion in the craniocaudal direction. This phantom consisted of a moving platform, the I'm MatriXX, and solid water phantoms. A 6 MV photon filed with a field size of $4{\times}4cm^2$ was delivered to the phantom using the gating system, while the phantom moved in the 1-, 2-, 3-, 4-, and 5-cm motion ranges. The gating windows were set at 40~60%, 30~40%, and 0~90%, respectively. The I'm MatriXX acquired the dose distributions for each scenario and the dose distributions were compared with a $4{\times}4cm^2$ static filed. The tolerance of the gamma index was set at 3%/3 mm. The greater the gating window, the lower the pass rate, and the greater the motion range, the lower the pass rate in this study. In case treatment without gated radiation therapy for the target with motion of 2 cm, the pass rate was less than 96%. But it was greater than 99% when gated radiation therapy was used. However gated radiation therapy was used for the target with motion greater than 4 cm, the pass rate could not be greater than 97% when gating window was set as 30~70%. But when the gating window set as 40~60%, the pass rate was greater than 99%.

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

Studies on the Preservative Condition and the Ultrastructure of Hair of Newly Found Sixteenth Century Mummy in Paju (파주에서 발견된 16세기 미라 머리카락의 미세구조과 보존상태에 관한 연구)

  • Lee, Gwi-Yeong;Chang, Byung-Soo
    • Applied Microscopy
    • /
    • v.35 no.4
    • /
    • pp.24-31
    • /
    • 2005
  • The preservative condition and ultrastructure on the mummified hair collected from newly found female mummy in Paju, were investigated by using scanning and transmission electron microscopes. The female mummy was found in september, 2002 during the traditional reburial process for the buried ones. The hair of 16th century mummy showed very intact appearances during observation with electron microscope. And the structures of the cortex, medulla and cuticle were well preserved. The cuticle layer was easily discernable, which are composed of six to seven cuticular cells. Each cuticular cells surrounded and thus seperated from its neighbors by intercellular membrane complex. In the cortex, many macrofibrils and some melanin granules between them were observed. We observed well preserved rod form macrofibrils running parallel along the direction of hair shaft. Especially, melanin granules were aggregated in the cortex which was adjacent to the cuticlu layer. As to the cause for the well-preservation of 440 year old hair sample, the presence of surface coat on the hair, which are composed of various materials. As calcium was included in the surface coat in Electron Dispersive X-ray Spectroscopy (EDS), the hardening process of the surface coat by calcium might inhibit the water or microorganism infiltration into the hair.

Soil Chemistry Changes after N, P, and K Fertilization in a Willow(Salix spp.) Bioenergy Plantation (버드나무(Salix spp.) bioenergy 조림지내(造林地內) N, P, K 시비(施肥)가 토양화학성(土壤化學性) 변화(變化)에 미치는 영향(影響))

  • Park, Gwansoo
    • Journal of Korean Society of Forest Science
    • /
    • v.86 no.3
    • /
    • pp.311-318
    • /
    • 1997
  • Chemical properties of soil(N, P, K, Ca, Na, Mg, CEC, and pH) were studied after annual additions of $NH_4NO_3$(336kg/ha N), treble superphosphate(112kg/ha P), and KCl(224kg/ha K) fertilizers in a willow(Salix spp.) bioenergy plantation. Soil samples were collected from November through December 1992 from previously established the fertilized and non-fertilized willow plantation at Tully, New York, U.S.A. in 1987. Total fertilizer additions from 1987 through 1991 were 1,680kg/ha N and 560kg/ha P and 1.120kg/ha K. Fertilization with N, P, and K resulted in no difference in total soil N content between the fertilized and non-fertilized plots, increased soil P and K, decreased base cations ($Ca^{2+}$ and $Mg^{2+}$) and soil pH, and increased soil pH with soil depth. Strong positive correlations of soil carbon to soil N, Ca, Mg, and CEC were noted. Soil C/N ratio in the study plots ranged from 9.6 to 11.2 for all treatment combinations. Significant differences in soil P, K, Ca, and pH between the fertilized and non-fertilized plots indicate that fertilization had changed chemical properties of soil in this fertilizer trial.

  • PDF

Mineralogical Characteristics and Provenance of Cu-bearing Green Minerals Used as Traditional Pigments (전통 안료로 사용된 구리함유 녹색광물의 광물학적 특성과 산지추정)

  • Do, Jin-Young;Jung, Jongmee
    • Journal of the Mineralogical Society of Korea
    • /
    • v.31 no.2
    • /
    • pp.123-135
    • /
    • 2018
  • This study tried to find the clue to Seokrok province by comparing Seokrok used in painting culture properties with Seokrok ore from domestic occurrence and imported Seokrok ore. To this end, chemical and mineralogical characteristics of painting cultural properties were identified with portable X-ray Florescence (p-XRF), micro X-ray diffraction (micro XRD) and SEM/EDS Analysis. To obtain Pb isotopic ratio, the Pb contained in Seokrok has been analyzed with Thermal Ionization Mass Spectrometer. Atacamite (or botallackite) and small quantity of brochantite were identified from Seokrok in Dancheong, and malachite was also identified from Buddhist painting besides those two ingredients. Without distinction of type, most Seokrok used in painting cultural properties is atacamite composed of Cu and Cl. From Pb isotope analysis, it was found that Seokrok in painting cultural properties was closer to that of north Korea, north China and Japan than south Korea as in regional division for East North Asia suggested by Mabuchi. The Pb isotopic ratio of domestic green mineral belongs to the distribution of Seokrok inside the painting cultural properties but imported malachite showed considerably difference. Considering the fact that atacamite, the main mineral of Seokrok in painting cultural properties is rarely produced from southern mine of the Korean Peninsula and the result of Pb isotope analysis.

Carbon Fiber as Material for Radiation Fixation on Device : A comparative study with acrylic (고정기구 재질로써 탄소 섬유와 아크릴의 방사선량 감쇄 영향 비교)

  • Chie, Eui-Kyu;Park, Jang-Pil;Huh, Soon-Nyung;Hong, Se-Mie;Park, Suk-Won;Kim, In-Ah;Wu, Hong-Gyun;Kim, Jae-Sung;Kang, Wee-Saing;Kim, Il-Han;Ha, Sung-Whan;Park, Charn-Il
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • Radiation absorption parameters of carbon fiber panel were measured in comparison to acrylic panel. $30{\times}30cm$ sized 2mm thick carbon fiber panel and identical sized 6mm thick acrylic panel were placed in tray holder position and 0cm, 5cm, 10cm from surface of phantom. Radiation field size was $10{\times}10cm$. 50MU of 4MV photon was irradiated to the phantom with dose rate of 300MU/min. Source-to-phantom distance was 120cm. Radiation dose was measured with 0.6cc Farmer-type ionization chamber with 1cm build-up. Measurement was repeated thrice and normalization was done to the dose of the open field. Radiation transmission rate of carbon fiber panel is approximately 1% lower than acrylic panel of equivalent thickness. However, considering the strength of the material, transmission rate is higher for carbon fiber panel. Although carbon fiber panel increases the radiation dose when attached to the surface for about 2%, it normalizes the radiation dose to 97-99% of irradiated dose which could have been lowered to as much as 5-7.5% with acrylic panel. As carbon fiber panel is stronger than acrylic panel, radiation fixation device could be made thinner and thus lighter and furthermore, with increased radiation transmission. This in turn makes carbon fiber more ideal material for radiation fixation device over conventionally used acrylic.