• Title/Summary/Keyword: 이온교환능력

Search Result 123, Processing Time 0.033 seconds

Removal of Radioactive Ions from Contaminated Water by Ion Exchange Resin (오염된 물로부터 이온교환수지를 이용한 방사성이온 제거)

  • Shin, Do Hyoung;Ju, Ko Woon;Cheong, Seong Ihl;Rhim, Ji Won
    • Applied Chemistry for Engineering
    • /
    • v.27 no.6
    • /
    • pp.633-638
    • /
    • 2016
  • In this study, we used three kinds of commercially available cation, anion, and mixed-ion exchange resins to separate radioactive ions from a polluted water containing Cs, I, and other radioactive ions. The experiment was conducted at a room temperature with a batch method, and a comparative analysis on the decontamination ability of each resin for the removal of Cs and I was performed by using different quantities of resins. The concentration was analyzed using ion chromatography and the ion exchange resin product from company D showed an overall high ion exchange ability. However, for most of the experiments when the amount of ion exchange resin was decreased, the decontamination ability of the resins against mass increased. When the mass of company D's cation exchange resin was small, the ion exchange ability against Cs and I ions were measured as 0.199 and 0.344 meq/g, respectively. When the mixed ion exchange resin was used, the ion exchange ability against I ions was measured as 0.33 meq/g. All in all, company D's ion exchange resins exhibited a relatively higher ion exchange ability particularly against I ions than that of other companies' exchange ions.

Ion Exchange Modeling with Sequencing Chemical Equilibrium (연속화학평형 모델을 이용한 이온교환 모델링)

  • 이인형;안현경
    • Proceedings of the KAIS Fall Conference
    • /
    • 2002.11a
    • /
    • pp.306-308
    • /
    • 2002
  • 원자로냉각재계통(Reactor Coolant System) 및 사용 후 저장조정화계통(Spent Fuel Pool Purification System)에는 양ㆍ음이온 교환수지가 충진된 혼상 이온교환수지탑을 설치하여 계통수에 존재하는 방사성 핵종을 제거하고 있으며, 정화율을 나타내는 제염계수(Decontamination Factor)가 특정값 이하이면 수지를 교체하고 있다. 그러나 특정 핵종에 대한 제염계수가 수지 사용기간에 관계없이 기준값 이하로 나타나고 있고, 수지탑의 성능을 예측하고 있지 못하는 실정이다. 원자력발전소 1차 계통에 설치되어 불순물을 제거하는 이온교환 수지탑에 대한 연속화학평형모델에 적용한 결과 수지탑에서 이온 용출은 수지에 대한 이온 선택도 순서와 동일하고 냉각재계통에는 붕산이 주성분이므로 음이온수지에서 붕산이 가장 먼저 누출된다. 그리고 붕산으로 포화된 음이온수지의 음이온 불순물 제거능력은 저하되지 않으며, 리튬으로 포화된 양이온수지의 양이온 불순물 제거능력은 저하된다.

Synthese von selektiv wirksamen lonenaustauscher auf Polystyrol-Basis (Polystyrol을 기반으로 한 특수 이온교환 수지의 제조)

  • Kim, Un-Young
    • Journal of the Korean Chemical Society
    • /
    • v.14 no.1
    • /
    • pp.37-43
    • /
    • 1970
  • Durch Umsetzung an vernetzten p-lithiumstyrolhaltigen Copolymeren ist es nicht moglich, Austauscherharze mit Benzoylaceton-oder 8-Hydroxy-chinolingruppen mit praktisch brauchbarer Kapazitat herzustellen. Tetraphenylarsoniumchlorid-Gruppierungen enthaltende Austauscher mit einem Gehalt von etwa 1,3 mval/g an funktionellen Gruppen lassen sich aus vernetzten p-lithiumstyrolhaltigen Copolymeren und Triphenyl-arsinoxid herstellen. Aus einer Quecksilber(II)-chlorid-Losung nehmen in wassrigem Dioxan etwa 60% der im Harz befindlichen funktionellen Gruppen Quecksilberionen auf.

  • PDF

Synthesis of Zeolite from Waste LCD Panel Glass (폐 LCD 패널유리를 이용한 제올라이트의 합성)

  • Lee, Chul-Tae
    • Applied Chemistry for Engineering
    • /
    • v.28 no.5
    • /
    • pp.521-528
    • /
    • 2017
  • To find a recycling method for waste liquid crystal display (LCD) panel glasses, we investigated the synthesis process of zeolite with an ion exchange ability by hydrothermal reaction using waste LCD panel glass as a raw material. It was shown that the waste LCD panel glass can be used as a raw material for the production of zeolites having the ion exchange ability. Following conditions for the synthesis of the zeolite with an ion exchange ability were required : the molar ratio of Si to Al components of the waste LCD glass needs to be 2.0 to 2.8, and the temperature of $100^{\circ}C$ and reaction time of 12 hours are needed for the hydrothermal reaction. Based on the required conditions previously mentioned, the A type zeolite was synthesized when the molar ratio of the Si to Al component was 2.0, and the P type zeolite was produced when the molar ratio was 2.8. The type A zeolite synthesized by using the waste LCD panel glass showed a good ion exchange ability and heavy metal adsorption ability. Also, an excellent ion exchange capacity was observed as the crystal phase grows stably in a cubic phase.

Efficient bio-gas desulfurization purification technology development Using ion-exchange fibers (이온교환섬유를 이용한 바이오가스 고효율 탈황정제기술 개발)

  • Tak, Bong-Yeol;Tak, Bong-Sik;Min, Gil-Ho;Lee, Sang-Min;Lee, Won-Gu;Lee, So-A
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.116-116
    • /
    • 2011
  • 바이오 가스 플랜트의 혐기소화 공정에서 발생하는 바이오 가스는 중 유해가스인 황하수소($H_2S$)는 부식성 가스로 수천 PPM농도를 함유하여, 발전기나 가스보일러로 이용하는 경우에는 $H_2S$를 제거하는 탈황공정이 반드시 필요하다. 탈황방식에는 산화철 탈황(건식 탈황)과 생물 탈황이 현재 많이 사용되고 있어나 산화철 탈황은 산화철 pellet이 유화철에 변화하면 탈황능력이 저하되어 pellet을 교환해야 하며 많은 비용이 발생한다. 생물 탈황 방식은 유황산화세균의 서식활동조건(온도, 반응시간, 산소량)확보가 반드시 필요하여 높은 운전기술을 필요로 한다. 본 연구에서는 바이오가스 전처리 기술 중 활성탄 또는 약액을 이용한 기존의 탈황정제방식보다 흡착성능이 뛰어난 이온교환섬유를 이용하여, 황화수소($H_2S$)를 95% 이상 제거할 수 있는 고효율 섬유상 이온촉매 악취제거 시스템 개발을 수행하였다. 이온교환섬유는 방사선 조사를 이용하여 부직포에 라디칼을 인위적으로 형성시켜(그라프트 중합) 양이온 또는 양이온을 교환할 수 있도록 제조된 섬유상의 흡착제로, 이온교환 섬유의 화학적 이온교환과 물리적 흡착 및 탈착반응이 동시에 발생되고, 활성탄/실리카켈 보다 흡착능력이 2~4배 높다. 또한 이온섬유의 재생기능을 이용하여 장기적 다양한 악취($H_2S$, $NH_3$, 아민계, 메르갑탄류, 알데히드 등) 및 유해가스(VOCs, NOx, SOx) 등을 95% 이상 제거할 수 있다.

  • PDF

A Study on Ion Exchange Characteristics with Composition and Concentration of Electrolyte, Ratio of Ion Exchange Resin (전해질 성분 및 농도, 이온교환 수지 비율에 따른 이온교환 특성 연구)

  • Ahn Hyun-Kyoung;Rhee In-Hyoung;Yoon Hyoung-Jun;Jeong Hyun-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.727-732
    • /
    • 2006
  • The object of this study was to investigate the influence of composition and concentration of electrolyte, ratio of cation to anion exchange resin of mixed ion exchange column in the performance of ion exchange. Also this work examined the removal capability of suspended solids by ion exchange resin and the effect of particule on the characteristics of ion exchange. Breakthrough time was extended as the amount of ions and particles present in liquid was decreased. The case of anion, the breakthrough sequence is $Cl^{-}, but the case of cation, the breakthrough sequence is $Na^{+}. As for the ratio of cation to anion exchange resin of 1:2, the breakthrough time was prolonged compared with that of 1:1 and 1:3. For the electrolyte of equal concentration containing suspended solid, breakthrough time was contracted less than 20%. It results in the increase in the removal capacity of cation exchange resin. For the higher ratio of cation exchange resin, suspended solids are shorten the cation's breakthrough time so that the runtime of ion exchange resin tower is increased.

  • PDF

Treatment of Simulated Soil Decontamination Waste Solution by Ferrocyanide-Anion Exchange Resin Beads (Ferrocyanide-음이온 교환수지에 의한 모의 토양제염 폐액 처리)

  • Won Hui Jun;Kim Min Gil;Kim Gye Nam;Jung Chong Hun;Park Jin Ho;Oh Won Zin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.1
    • /
    • pp.41-47
    • /
    • 2005
  • Preparation of ferrocyanide-anion exchange resin and adsorption test of the prepared resin on the Cs$^{+}$$ion were performed. Adsorption capability of the prepared resin on the Cs$^{+}$ion in the simulated citric acid based soil decontamination waste solution was 4 times greater than that of the commercial cation exchange resin. Adsorption equilibrium of the prepared resin on the Cs$^{+}$ion reached within 360 minutes. Adsorption capability on the Cs$^{+}$ion became to decrease above the necessary Co$^{2+}$ion concentration in the experimental range. Recycling test of the spent ion exchange resin by the successive application of hydrogen peroxide and hydrazine was also performed. It was found that desorption of Cs$^{+}$ion from the resin occurred to satisfy the electroneutrality condition without any degradation of the resin.

  • PDF

Chloride Penetration Properties of Portland Cement Mortar Substituted with Anion Exchange Resin Powder (음이온교환수지 분말이 치환된 포틀랜드 시멘트 모르타르의 염소이온 침투 특성)

  • Lee, Yun-Su;Lim, Seung-Min;Park, Jang-Hyun;Jung, Do-Hyun;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2020
  • Chloride ion, which penetrates into the cement composites from the outside, generally diffuses by the concentration gradient. Chloride ions are adsorbed by the chemical reaction with cement hydrates. Recent studies have shown that anion exchange resin (AER) powder can effectively adsorb the chloride ion in the cement composites, and thus, the cement composites containing AER have a high chloride adsorption capacity and a good resistance for chloride penetration. In this study, the chloride adsorption ability of the AER powder was investigated under the conditions of distilled water and calcium hydroxide saturated solution to determine if the AER powder is less effective to increase the chloride adsorption ability after grinding process. The chloride adsorption ability of AER powder was compared with the previous research about the chloride adsorption of AER bead. In addition, the compressive strength, chloride diffusion coefficient (using NT Build 492 method), and the chloride profile of cement mortar substituted with AER powder were investigated. There was no decrease in the chloride adsorption capacity of AER powder but increase in the kinetic property for chloride adsorption after the grinding process. The AER powder could absorb the chloride ion in the mortar quickly, and showed better chloride ion adsorption ability than the cement hydrates.

A Study on the Phase Identification and Ion-Exchange Behavior of NH4+ at Natural Zeolite (천연제올라이트의 상규명 및 아모니아 제거 특성)

  • Kim, Wha-Jung;Yoo, Jae-Churl;Lee, Myung-Churl;Lee, Gee-Jung
    • Applied Chemistry for Engineering
    • /
    • v.7 no.1
    • /
    • pp.43-50
    • /
    • 1996
  • A series of domestic natural zeolites were investigated to identify the phase and to study the capability of $NH_4{^+}$-ion removal from solution system. It was proved that the natural zeolite from Young-II bay area was thermally unstable zeolite, heulandite by XRD and FT-IR analyses. In addition, the heulandite exchanged by $K^+$ ion showed the highest thermal stability upon heat-treatments. However, the best capability of removing $NH_4{^+}$-ion from the solution system was the non-exchanged zeolite.

  • PDF

A study on the separation and determination of the rare earth Elements by the AG® 50W-X8 cation exchange resin (AG® 50W-X8 양이온교환수지를 이용한 희토류원소의 분리와 분석에 관한 연구)

  • Lee, Jung Sook;Choi, Beom Suk
    • Analytical Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.272-278
    • /
    • 2008
  • Methods to separate 14 rare earth elements (REEs) and yttrium by the $AG^{(R)}$ 50W-X8 cation exchange resin, and to determine REEs by inductively coupled plasma atomic emission spectrophotometry (ICP-AES) were described. Ion exchange capacities of REEs on the resin were so high that the REEs were quantitatively ion exchanged under the flow rate of 0.3~1.0 mL/min at pH 1~6. The breakthrough capacity curve of the REEs showed that ion exchange capacities of light REEs (Cerium group) were greater than that of the heavy REEs (Yttrium group). When $200{\mu}g$ of each REEs was ion exchanged on 100 mg of resin, most of the heavy REEs were quantitatively desorbed with 10 mL of 2.0 M of $HNO_3$, while most of the light REEs with 30 mL. The method was applied to the monazite sample. The REEs could be separated from matrix, since ion exchange capacities of matrix ions of Ca, Ti, Mg, Mn were much lower than that of the REEs. However the relative standard deviations of the analytical results by the present method were not improved, as high as 1~5%.