• Title/Summary/Keyword: 이승종

Search Result 960, Processing Time 0.026 seconds

The accuracy of the frequency dependent type apex locator (주파수의존형 전자근관장측정기의 정확도에 관한 연구)

  • Park, Ju-Huun;Roh, Byoung-Duck;Lee, Seoung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.150-160
    • /
    • 1996
  • The present study was to evaluate the accuracy of the frequency dependent type apex locator, Root-ZX. The subjects included 505 root canals of 238 teeth treated by the Department of Conservative Dentistry, and 22 human premolars which were schduled to be extracted for the orthodontic reasons. The results were as follows ; 1. The working lengths determined by Root-ZX were compared with radiographic readings. Of the total 505 root canals, 66 % showed coincidence within ${\pm}0.5mm$ and the average readings of Root-ZX were $0.13mm{\pm}1.05$ longer than those of radiographic readings. 2. The length difference between the file tip determined by Root-ZX and the apical constriction in extracted teeth were measured. Of the total 24 root canals, 70.8 % showed coincidence within ${\pm}0.5mm$ and the average readings of Root-ZX were $0.12mm{\pm}0.50$beyond the apical constriction. 3. The vitality of the teeth did not show any statistical difference(p>0.05) in the accuracy of the Root-ZX readings. The presence of the periapical lesions, however, significantly lowered the percentage of ${\pm}0.5mm$ accuracy in Root-ZX measurements.(p<0.05). In the presence of periapical lesions, the percentage within ${\pm}0.5mm$ was significantly lower.

  • PDF

THE EFFECT OF CO2 LASER ON DENTAL PULP OF DOG (CO2 laser조사가 성견치수에 미치는 영향에 관한 실험적 연구)

  • Kim, Hee-Joong;Lee, Chan-Young;Lee, Sung-Jong;Lee, Chung-Suck
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.1
    • /
    • pp.7-19
    • /
    • 1988
  • The object of this paper was to investigate the histopatological changes on dog's pulp under cavitation by irradiation of the $CO_2$ laser. The subjects were derived from four dogs, and irradiated 113.23 J/$mm^2$, 283.09 J/$mm^2$, 566.08 J/$mm^2$ in Group I, II, and III respectively. The dogs were sacrificed immediately, 24 hour, 72 hour and 1 week after $CO_2$ laser treatment. For light microscopic examination, routine H-E and PAS stains were employed. For electron microscopic observation, the teeth were fixed in 1% paraformaldehyde and 1% glutaraldehyde, decalcified teeth in 10% EDTA were stained by uranyl acetate and lead citrate. The observation was made with a Hitachi H-500 model electron microscope. The following results were obtained in this study: 1. At the early stage of the experimental sub-groups-immediately, 24 hour, 72 hour samples of Group I, II and III-coagulation necrosis and hyperemia were observed in odontoblastic and subodontoblastic pulpal layer. 2. At the 1 week sub-group of Group I, II, regenerative hyperplasia of the odontoblasts without coagulation necrosis were revealed, in addition to thickened predentin. On he other hand coagulation necrosis and atrophic change accompanying with hyperplasia were found at the 1 week sub-group of Group III. 3. Ultrastructurally, the odontoblasts appeared nuclear degeneration, vacuolar change of cytoplasmic organelles and rupture of plasma membrane at the early stage of the experimental period of all groups. 4. Under spectrohelioscopic examination, regenerative odontobalsts were seen at the 1 week specimens of Group I, II and III. 5. The pulpal response occured at 113-566 J/$mm^2$. The pathologic change of pulp tissue occured at the early experimental period but regeneration of odontoblasts could be seen after 1 week.

  • PDF

New Measuring Method of Breast Volume Using Polyethylene Bag and Plaster Molding (투명 폴리백과 반창고를 이용한 간편한 유방 부피 측정법의 소개)

  • Lee, Seung Jong;Lee, Hye Kyung;Tark, Kwan Chul;Shin, Keuk Shun
    • Archives of Plastic Surgery
    • /
    • v.33 no.5
    • /
    • pp.676-679
    • /
    • 2006
  • Purpose: Breast volume is one of the crucial measurements in preoperative planning and postoperative evaluation of the results in mammoplasty. There are several methods suggested by different authors, but there is still no commonly accepted standard methods for measuring breast volume. To help the surgeons to base their estimation on an objective evaluation, we developed a simple method using Polyethylene bag and plaster molding. Methods: After Polyethylene bags were put in suitable size on both breasts of the patient in upright position, silk plaster was molded on the surface evenly. Then molds can be obtained after marking boundaries of breasts with a pen. Breast volume measurement can be done by filling water in the molds and measuring it. Moreover, postoperative design for natural skin brassier was possible using the molds. Results: This method was applied to 2 patients for reduction mammoplasty and the breast volume measurement was simple, hygienic and accurate, done within 10 minutes. Conclusion: This method using Polyethylene bag and plaster molding has several advantages. 1. It is comparatively accurate regardless of the size and shape of patient's breasts in upright position. 2. Measurement time is short and inconvenience and shame of patients can be reduced by making molds after putting on Polyethylene bags. 3. It is relatively economical and uses easily available hygienic materials. 4. The postoperative shape and volume of breasts can be predicted by using molds preoperatively.

Winter Warming and Long-term Variation in Catch of Yellowtail (Seriola quinqueradiata) in the South Sea, Korea (겨울철 온난화와 남해 방어 어획량의 장기변동)

  • Lee, Seung-Jong;Go, You-Bong
    • Korean Journal of Ichthyology
    • /
    • v.18 no.4
    • /
    • pp.319-328
    • /
    • 2006
  • The relationships among long-term climate variation at the southern part of the Korean peninsula, oceanic conditions in the South Sea, Korea, and variation in the winter catch of yellowtail (Seriola quinqueradiata) were analyzed using 32 years of time-series data from 1971~2002. In the early 1990s, winter climatic conditions at the southern part of Korean peninsula shifted from a cool to a warm regime with higher air temperature, relative weak wind speed, and lower relative humidity. Also, the winter water temperature at 50 m depth became consistently higher in the South Sea. The annual winter catch of yellowtail in the South Sea increased dramatically in the early 1990s, as did that of anchovy, which is the major food organism for yellowtail. From the results of correlation analysis, we found that the winter catch of yellowtail was more closely related to the increasing of air temperature, water temperature and anchovy catch.

Annual Reproductive cycle of the File Fish, Stephanolepis cirrhifer, on the Southern Coast of Cheju Island (제주 남부 연안 쥐치, Stephanolepis cirrhifer의 생식년주기)

  • Lee, Seung-Jong;Go, You-Bong;Lee, Young-Don
    • Korean Journal of Ichthyology
    • /
    • v.12 no.1
    • /
    • pp.62-70
    • /
    • 2000
  • Annual reproductive cycle of the file fish, Stephanolepis cirrhifer (Temminck et Schlegel), was histologically investigated. Samples were collected monthly in the coastal waters of Chungmun, south of Cheju Island, Korea from July 1997 to June 1999. In males and females of S. cirrhifer, the values of GSI (gonadosomatic index) were similar to the changes of water temperature and day length. GSI values in males and females were reached the maximum in June. Reproductive cycle could be divided into the following successive stages: in females, growing stage (February to May), mature stage (May to June), spawning stage (June to August), degenerative and resting stage (September to December), and in males, growing stage (February to April), mature stage (May to June), spent stage (June to August), degenerative and resting stage (September to January), respectively. Throughout histological observation of the ovary in the spawning period, the species belong to an asynchronous and multiple spawner.

  • PDF

자가 치아 이식술에 사용되는 Computer Aided Rapid Prototyping model(CARP model)의 실제 치아에 대한 오차

  • Lee, Seong-Jae;Kim, Ui-Seong;Kim, Gi-Deok;Lee, Seung-Jong
    • The Journal of the Korean dental association
    • /
    • v.44 no.2 s.441
    • /
    • pp.115-122
    • /
    • 2006
  • Objective : The purpose of this study was to evaluate the dimensional errors between real tooth, 3D CT image and CARP model. Materials and Methods : Two maxilla and two mandible block bones with intact teeth were taken from two cadavers. Computed tomography was taken either in dry state and in wet state. After then, all teeth were extracted and the dimensions of the real teeth were measured using a digital caliper at mesio-distal and bucco-lingual width both in crown and cervical portion. 3D CT image was generated using the V-works $4.0^{TM}$ (Cybemed Inc., Seoul, Korea) software. Twelve teeth were randomly selected for CARP model fabrication. All the measurements of 3D Ct images and CARP models were made in the same manner of the real tooth group. Dimensional errors between real tooth, 3D CT image model and CARP model was calculated. Results : 1) Average of absolute error was 0.199 mm between real teeth and 3D CT image model, 0.169 mm between 3D CT image model and CARP model and 0.291 mm between real teeth and CARP model, respectively. 2) Average size of 3D CT image was smaller than real teeth by 0.149 mm and that of CARP model was smalier than 3D CT image model by 0.067mm. Conclusion : Within the scope of this study, CARP model with the 0.291 mm average of absolute eror can aid to enhance the success rate cf autogenous tooth transplantation due to the increased accuracy of recipient bone and donor tooth.

  • PDF

Development of an Electric Pulp Tester with Constant Current Source (정 전류원을 이용한 치수 검사기의 개발)

  • 김재성;남기창;김수찬;이승종;김덕원
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.2
    • /
    • pp.61-68
    • /
    • 2004
  • Electric stimulation of teeth has been used for assessing pulp vitality. The principle is based upon the assumption that a subject feels the pain produced by electrical current stimulation of intradental nerve. Because of very high and wide range of impedance of the enamel, it is very difficult to determine stimulation levels regardless of teeth status. Most pulp testers adopt voltage stimulation method and thus, their stimulating threshold levels significantly depend on each individual. Therefore, a constant current stimulator is necessary to minimize the effect of wide variation due to different enamel thickness. And it is also necessary to test teeth vitality with a wide current range regardless of tooth impedance. In this study, we constructed a burst-wave type pulp tester to reduce the pain using a current stabilizing circuit with the maximum current of 150 uA.

A Performance Comparison of On-Demand Routing Protocols for Application Services in MANET (MANET에서 응용 서비스 데이터 유형에 따른 요구기반 라우팅 프로토콜의 성능비교)

  • Jang Jun-Young;Lee Kil-Sup;Lee Sung Jong
    • The KIPS Transactions:PartC
    • /
    • v.11C no.7 s.96
    • /
    • pp.871-878
    • /
    • 2004
  • Recenty, there has been great interest in MANET from various areas. In this paper we focus on performance analysis of on demand routing protocols surf as DSR, AODV, and TORA in MANET. We have conducted several simulations concerned with application service data such as sensor, text. voice, and video data. And then, we have evaluated the performance of three protocols in a pre-designed ad hoc network, which is consisted of 20 nodes. As a result, we have obtained quantitative data for packet delivery fraction, average end to-end delay, routing load, channel utilization from upper layer and supportable routing protocol for application service data. The results can be used for designing specific-purposed ad-hoc networks.

A Quantitative Quality Evaluation Approach for the Artifacts of the Defense Component Based Development (국방 CBD 산출물을 위한 정량적 품질 평가 방법)

  • Lee Kil-Sup;Lee Hyun-Chul;Lee Sung Jong
    • The KIPS Transactions:PartD
    • /
    • v.12D no.7 s.103
    • /
    • pp.993-1000
    • /
    • 2005
  • Recently, software quality evaluation based on ISO/IEC 9126 and ISO/IEC 14598 has been widely accepted in various areas. However, these standards for software quality do not provide practical guidelines to apply the quality model and the evaluation process of software product=5. And the qualify management in most software projects has been conducted by managing defects without applying the standards for software qualify. Thus, we present a quantitative quality evaluation approach of artifacts in the Component Based Development (CBD). Particularly, our evaluation approach allows most of the standard evaluation process and adopts a quantitative quality model which uses the weights of quality characteristics obtained through carefully selected questionnaires for stakeholder and Analytic Hierarchical Process(AHP). Moreover, we have also examined the proposed evaluation approach with applying the checklists for the artifacts of the CBD to a small-scale software project. As a result, we believe that the proposed approach will be helpful for acquiring the high quality software.

AN EXPERIMENTAL STUDY OF THE EFFECT OF THE EDTA ON HUMAN DENTIN HARDNESS (EDTA가 상아질의 경도 변화에 미치는 영향에 관한 실험적 연구)

  • Lee, Sang-Ki;Lee, Chung-Suck;Park, Dong-Soo;Lee, Seung-Jong;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.2
    • /
    • pp.93-103
    • /
    • 1990
  • The primary purpose of this study was to assess the effect of the EDTA on human dentin hardness of root. The 30 extracted human anterior teeth were divided into three groups, and EDTA was applied on the each tooth root dentin surface for 5, 15 and 30 minutes to evaluate the dentin hardness. The following results were obtained : 1. The KHN of dentin was decreased by 21.3% from 50.8 to 40.0 in 5 min. group, 44.2% from 48.4 to 27.0 in 15 min. group, and 51.9% from 48.0 to 23.1 in 30 min group. 2. The decrease rate per 1 min. of KHN of dentin was 4.3 in 5 min. group, 2.9 in 15 min. group, and 1.7 in 30 min. group. 3. As time passed, the KHN of dentin of 5 min. group and 15 mim. group were significantly decreased, but the KHN of dentin of 30 min. was not significantly decreased compared with 15 min. group. There was a statistical significance in the decrease rate of KHN of dentin among 3 groups(P<0.05).

  • PDF