• Title/Summary/Keyword: 이수열

Search Result 500, Processing Time 0.038 seconds

NUMERICAL OPTIMIZATION OF TEMPERATURE DISTRIBUTION IN HRSG SYSTEM USING INLET GUIDE VANE (전치 가이드 베인 설치에 따른 열회수 보일러 입구 온도 최적화)

  • Lee, Soo-Yoon;Ahn, Joon;Shin, Seung-Won
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.148-154
    • /
    • 2008
  • Diverging channel from gas burner exit to the inlet section of Heat Recovery Steam Generator (HRSG) has been re-designed for 1 MW system. To improve the uniformity in velocity and temperature distribution of existing design(Case A and B) of 300 kW HRSG system, two additional test geometries have been chosen for the numerical simulation. At first, gas burner exit section has been centered to the inlet section of boiler(Case C) and uniformity has been improved considerably. Secondly, the diverging channel length can be further reduced for compact geometry with new guide vane design (Case D and E). Proposed design shows overall improvement in uniformity in velocity and temperature distribution compared to existing one.

  • PDF

NUMERICAL OPTIMIZATION OF TEMPERATURE DISTRIBUTION IN HRSG SYSTEM USING INLET GUIDE VANE (전치 가이드 베인 설치에 따른 열회수 보일러 입구 온도 최적화)

  • Lee, Soo-Yoon;Ahn, Joon;Shin, Seung-Won
    • Journal of computational fluids engineering
    • /
    • v.14 no.3
    • /
    • pp.1-8
    • /
    • 2009
  • Diverging channel from gas engine exit to the inlet section of Heat Recovery Steam Generator (HRSG) has been re-designed for 1 MW system. To improve the uniformity in velocity and temperature distribution of existing design(Case A and B), two additional test geometries have been chosen for the numerical simulation. At first, gas burner exit section has been centered to the inlet section of the boiler(Case C) and uniformity in velocity and temperature distribution has been improved considerably. Secondly, the diverging channel length can be further reduced to compact geometry with new guide vane design (Case D and E). Proposed design shows overall improvement in uniformity in velocity and temperature distribution compared to existing one.

Packet Error Rate Model for DAB system (DAB 시스템에서의 패킷오율 모델링)

  • Lee, Hyun;Jo, Sammo;Lee, Bong-Ho;Lee, Soo-In
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.201-206
    • /
    • 2002
  • 패킷 기반 통신 시스템에서는 비트오율 보다는 패킷오율이 시스템 파라미터 설계에 보다 중요한 역할을 한다. 패킷오율을 분석하기 위해서는 대부분의 접근이 패킷을 이루고 있는 비트열의 오류 발생 사건을 독립이라고 가정한다. 그러나 실제의 통신 시스템에서는 오류 발생 형태가 버스트 형태로 그룹을 이루고 있다[1]. 본 논문은 비터비 디코더를 포함하는 통신시스템에 있어서의 버스트의 확률 분포를 기반으로 한 PER 모델을 제안하고, Eureka-147 방식의 디지털 오디오 방송 시스템의 시뮬레이션을 통하여 얻은 비트열에 대한 패킷오율과 제안한 패킷오율 모델과의 비교를 통하여 제안한 모델을 검증하였다.

  • PDF

A Study of Water Curtain Nozzles Installation for Wooden Cultural Asset Protection (목조문화재 보호를 위한 수막노즐의 개발에 관한 연구)

  • Kim, Kyong-Jin;Lee, Su-Jyung;Song, Dong-Woo;Yoon, Chuel-Jea;Kim, Ji-Hoon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.537-540
    • /
    • 2011
  • 중요 목조문화재를 산불이나 인접 건축물의 화재로부터 보호하기 위한 방안으로 수막노즐을 제시하였다. 바닥으로부터 일정압력 이상으로 상승하는 물줄기로 수막을 형성하여 복사열을 차단함으로써 $200^{\circ}C{\sim}250^{\circ}C$에서 발생하는 목재의 열분해를 막기 위한 것으로 기존에 설치되어 있는 강원도 낙산사와 전라남도 무위사의 수막노즐의 설치상태를 확인해 보았고 이를 보완 개량하기 위한 방안으로 평상시 덮개에 덮인 노즐을 설치하여 경관을 손상시키지 않게 하였고 사용 시 수직상승하여 물을 분사할 수 있는 상하승강식 노즐봉과 이를 효과적으로 설치하는 방법에 대하여 연구되었다.

  • PDF

Thermal-flow Characteristics of Magnetic Fluid for Concentric Annuli Under Fixing Magnetic Field Using Visualization Technique (가시화기법을 이용한 고정자장에서 이중원관내 자성유체의 열유동 특성에 관한 연구)

  • Kim, Hyung-Jin;Seo, Jae-Hyeong;Kim, Dae-Wan;Lee, Moo-Yeon;Seo, Lee-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.1
    • /
    • pp.26-30
    • /
    • 2013
  • This article is experimentally to investigate thermal-flow characteristics of the magnetic fluid for concentric annuli under externally fixed magnetic fields using visualization technique. Temperatures of the inner tube and outer tube in the tested concentric annuli were constantly maintained at both $30^{\circ}C$ and $25^{\circ}C$ and the middle tube was filled with the magnetic fluid. Magnetic field was uniformly applied using 4 permanent magnets at 4 directions of the concentric annuli. As a result, the thermal-flow characteristics of the magnetic fluid for concentric annuli could be controlled by directions of the external magnetic fields.

Near-field Target Localization Using Bottom-mounted Linear Sensor Array in Multipath Environment (다중경로환경에서 바닥고정형 선배열센서를 이용한 근거리표적의 위치추정기법)

  • 이수형;류창수;이균경
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.7
    • /
    • pp.7-14
    • /
    • 2000
  • In this paper, we propose a near-field target localization algorithm using a bottom-mounted linear sensor amy in a multipath environment. In a multipath environment, the conic angles of a target signals through each path are different, and the position of the target can be estimated using these conic angles and the time difference of these signals. We derive equations on the relation of time-difference of signals and conic angles estimates under the far-field assumption, and estimate the position of target by simultaneously solving these equations. For a certain geometry of a target and the sensor array, there exist cases when the conic angles are very close. In such a case, we estimate the position of the target using an additional 1-D search.

  • PDF

추력 30톤급 연소기의 냉각 성능

  • Cho, Won-Kook;Lee, Soo-Yong;Cho, Gwang-Rae
    • Aerospace Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.197-204
    • /
    • 2004
  • A design of regenerative cooling system of 30 ton level thrust combustion chamber for ground test has been performed. The 1-D design code has been validated by comparing with the heat flux of the NAL calorimeter for high chamber pressure and water-cooling performance of the ECC engine of MOBIS. The present design code has been confirmed to predict accurately the heat flux and water-cooling performance for high chamber pressure condition. The maximum hot-gas-side wall temperature is predicted to be about 720 K without thermal barrier coating and the coolant-side wall temperature is less than the coking temperature of RP-1. The coolant temperature rises nearly 100 K with thermal barrier coating when Jet-A1 is used as coolant.

  • PDF

Impact of climate change on hydrological cycle components in North Korea basins by statistical analysi (북한지역의 수문순환요소의 통계특성분석을 통한 기후변화 영향 평가)

  • Kwon, Bo Ra;Jeung, Se Jin;Kim, Byung Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.202-202
    • /
    • 2017
  • 전 세계적으로 기후변화로 인해 슈퍼태풍 및 극한 강우, 폭설과 한파, 온난화 현상이 발생하고 있으며, 한반도의 기후변화는 전 세계 평균보다도 빠르게 진행되고 있다. 특히 북한지역은 오랜 식량난과 에너지난으로 산림생태계가 훼손되어 홍수 및 이수와 같은 기후변화 관련 자연재해에 매우 취약하며, 무분별한 도시화에 따른 불투수층의 증가로 인해 유역내의 수문순환요소가 변화하고 있다. 이러한 기후변화에 효율적으로 대처하기 위해서는 체계적이고 과학적인 기상 및 기후정보의 활용이 중요하다. 하지만 본 논문의 대상지역인 북한지역은 우리가 수문자료를 구하기가 힘들고, 직접 측정 할 수 없기 때문에 수문순환분석에 한계가 있다. 따라서 본 논문에서는 WMO에서 제공하고 있는 북한의 27개 기상관측소의 강수량, 기온자료를 제공 받아 분석에 사용하였다. 본 논문에서는 기상정보를 이용하여 각 관측소별 잠재 증발산량을 산정하였으며, 또한 lumped conceptual model 인 WASMOD 모형을 이용하여 북한 미계측 유역의 유출량을 산정 하였다. 이렇게 산정된 수문순환요소 시계열 자료를 이용하여 통계분석, BCP, 유황분석등 시계열 분석을 통해 북한지역의 수문순환특성을 파악하고자 한다.

  • PDF

Design and Performance Analysis of Current Source for 3.0T MREIT System (3.0T MREIT 시스템을 위한 정전류원의 설계 및 성능검증)

  • 김규식;오동인;백상민;오석훈;우응제;이수열;이정한
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.165-169
    • /
    • 2004
  • In Magnetic Resonance Electrical Impedance Tomography (MREIT), we inject current through electrodes placed on the surface of a subject and measure the induced magnetic flux density distribution using an MRI scanner. This requires a constant current source whose output pulses are synchronized with MR pulse sequences. In this paper, we present a design and performance analysis of a current source used in a 3.0T MREIT system. The developed current source was tested using a saline phantom. We found that its performance is satisfactory for the current MREIT system. We suggest future improvements for better SNR(signal-to-noise ratio).

A Numerical Study for Natural Convective Heat Transfer by Finite Element Method (유한요소법을 이용한 자연대류열전달 수치해석 연구)

  • ;Ashley F. Emery
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.113-121
    • /
    • 1998
  • In natural convection flows, the fluid velocities are highly dependent on the thermal field and property variations can have a strong effect on both the flow and thermal fields. To examine the effect of property variations, at first, numerical analyses covering wide range of the Prandtl number under the same Rayleigh numbers have been carried out. Next, we have modeled the viscosity and thermal conductivity as parabolic functions of temperature and a comprehensive set of numerical solutions have been obtained to understand the effect. The Prandtl number dependence of Nusselt number is fairly strong even though the effect is still weak compared to the Rayleigh number dependence. When thermophysical properties are dependent on temperature, the flow field showed a fairly weak variation except near boundaries, whereas the temperature field is strongly affected, especially by the temperature dependent thermal conductivity.

  • PDF