• Title/Summary/Keyword: 이송차량

Search Result 70, Processing Time 0.027 seconds

Analysis of Ambulance Traffic Accident During Driving (국내 구급차량의 운행 중 사고 분석에 관한 조사 연구)

  • Shin, Dong-min;Yoon, Byung-gil;Han, Yong-taek
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.130-137
    • /
    • 2016
  • The purpose of this study is to investigate the circumstances surrounding collisions involving ambulances with an aim to improving the safe operation of emergency services. Collisions are relatively common within paramedic emergency services. We analyzed the time, injury site, and any other specific factors of 908 collisions occurring within four cities. Within our study 29.6% of paramedics have been involved in accidents while responding to an emergency call, with the main cause of the accident being signal violation (35.7%), and is the other party's negligence (22.2%). 92.1% of these accidents occurred while the emergency lights were being operated. XX% of accidents took place in the afternoon, while xx% took place within the hours of xx:xx and xx:xx, during which time there is generally lower levels of traffic, which can cause severe brain and neck damage of 14.4% but the other part is 62.1%. (Ed note; this is not clear at all. 14.4% of collisions resulted in severe head and neck injuries, while 23.5% of collisions resulted in no injury. According to the respondents, defensive driving (xx%), observance of traffic laws (xx%), safe driving habits (xx%)to paramedics were the most critical factors in evading collision. Signal passes were identified as the most common cause of collision (70.1%). Although the majority of collisions occurred while the emergency lights were operational, the damage can cause severe damage at the time of accident occurred.

Histogram Recorder System에 의한 측정예

  • Han, Eung-Gyo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.2 no.1
    • /
    • pp.21-27
    • /
    • 1985
  • 차량, 항공, 교량 및 기계구조물 등 랜덤한 실동하중을 받는 구조물의 응력 및 변위, 진동등의 피로 Data 또는 TRAFFIC 등에 의한 건축물의 변위 및 응력발생빈도를 집록하기 위한 Histogram Recorder System에 대한 내용과 측정예를 소개하고자 한다. 본 System은 8(4)챈 널의 스트레인 게이지 또는 스트레인 게이지식 각종변환기와 각종 Sensor로부터의 출력전압 등 Analog 입력을 수록하여, Digital 처리하여 micro computer를 사용, 미리 프로그램된 방식에 따라 측정과 동시에 실동시간으로 해석처리하여 빈도수로서 내부에 기억저장 시키는 것이다. 따라서 본 Histogtram Recorder 본체는 소형으로 견고하며 조금도 제어부분을 갖지 않고 소요의 해석방법의 프로그램백만을 셋트한 개별의 제어기만을 통해가지고 프로그램을 기입만 하며는 그다음은 손하나 안대고도, 그리고도 또 측정중에 제3자에 의한 제어조작 잘못이 발생할 위험도 없고 1 년이상에 걸친 장기간의 .+-. 32 Slices의 각 레벨당 각각 40 억을 넘는 대량의 빈도수를 자동적으로 집록 할 수가 있다. 집록된 Data는 제어장치에 의해 정리된 Datam는 제어장치에 의해 정리된 Histogram의 형태로 읽어나갈 수가 있어 관찰이 가능할 뿐만 아니라 프린터기록 또는 기록장치에 이송시켜서 Data 만 따로 가져올 수가 있어 필요에 따라서는 one line으로 Host computer에 접속시킬 수가 있어 더욱 고도의 처리를 할 수가 있다. 빈도해석프로그램으로서는 극대, 극소, 최대, 최소, 진폭, 시간 등을 pack으로서 준비되어 있어 이에 대한 시스템의 고성 동작 및 성능등을 소개하고자 한다.

  • PDF

Safety Analysts of Slide-up Seat for the Elder and the Handicapped (노약자를 위한 슬라이드엎 시트의 안전도 분석)

  • 이수철;임구
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2002.11a
    • /
    • pp.487-489
    • /
    • 2002
  • Recently, mobility and accessibility occurs for the elder and the handicapped in the aging problem. In this paper, we analyze the dynamics of slide-up seat, which helps to care the handicapped passenger in and out the automobile when we enjoy trip with the families including the elder and handicapped. We check the trajectories of slide-up seat inside and outside car to protect its corrosion and the stress at the joints of mechanical structure. Those can be helped to keep the safety and accuracy of the multiple dynamic systems for precision quality assurance in mass production.

  • PDF

Safety Analysis of Slide-up Seat for the Elder and the Handicapped (노약자를 위한 슬라이드엎 시트의 안전도 분석)

  • Lee, Soo-Cheol;Lim, Goo
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2002.11a
    • /
    • pp.487-489
    • /
    • 2002
  • Recently, mobility and accessibility occurs for the elder and the handicapped in the aging problem. In this paper, we analyze the dynamics of slide-up seat, which helps to care the handicapped passenger in and out the automobile when we enjoy trip with the families including the elder and handicapped. We check the trajectories of slide-up seat inside and outside car to protect its corrosion and the stress at the joints of mechanical structure. Those can be helped to keep the safety and accuracy of the multiple dynamic systems for precision quality assurance in mass production.

  • PDF

우주발사체 개발을 위한 발사대 케이블마스트(CABLE MAST) 사례조사

  • Lee, Jeong-Ho;Lee, Yeong-Ho;Kim, Yong-Uk;O, Seung-Hyeop
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.152.2-152.2
    • /
    • 2012
  • 우주발사체 발사를 위해서는 발사대시스템 개발이 필수적이다. 발사대시스템은 기계설비와 추진제공급설비, 관제설비로 구성되며, 그 중 기계설비는 발사지지대(Launch Pad), 이렉터(Erector), 트랜스포터이렉터(Transport-Erector), 케이블마스트(Cable-mast), 자동체결장치(Auto-coupling Device) 총 다섯 부분으로 나눌 수 있다. 발사지지대는 발사 전까지 발사체를 지지하는 구조물로 발사체의 안전을 보장하고 공급배관 및 통신라인의 경로를 제공한다. 이렉터는 발사준비과정에서 수평으로 이송된 발사체를 2개의 대형 유압실린더를 사용하여 기립시키는 장비로 발사 취소 시 발사체를 수평으로 전환한다. 트랜스포터이렉터는 조립공간에서 조립을 마치고 최종점검이 완료된 발사체를 전용차량을 이용하여 발사대로 이동하고 발사체를 안전하게 잡아준다. 자동체결장치는 지상으로부터 발사체로 연결되는 추진제, 압축가스 등의 연결배관을 자동으로 연결/분리하는 장치이다. 케이블마스트는 우주발사체 상단부의 UCU-E(Umbilical Connectors Unit-Electrical)를 통해서 전기, 고압가스, 고온공기 등을 공급하기 위한 통로로 발사 전까지 발사체시스템과 지상장비와의 통신수단이다. 또한 발사체로 연결되는 라인들을 발사 시에 나오는 후류에 의한 충격으로부터 보호하고, UCU-E가 기계적으로 분리되도록 구성되어 있다. 본 논문은 기존에 적용된 케이블마스트에 대한 구성, 기능 및 운용절차에 관한 것으로, 현재 진행 중인 한국형발사체 개발을 위한 기초 자료조사로 활용하고자 한다.

  • PDF

Structural Analysis of PWR(pressurized water reactor) Canister for Applied Impact Force Occurring at the Moment of Falling Plumb Down Collision (추락낙하 충돌 시 가해지는 충격에 대한 경수로(PWR) 처분용기의 구조해석)

  • Kwon, Young-Joo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.2
    • /
    • pp.211-222
    • /
    • 2011
  • In this paper a structural analysis of the PWR(pressurized water reactor) canister with 102cm diameter is carried out to evaluate the structural safety of the canister for the impact force occurring at the moment of collision with the ground in the falling plumb down accident from the carriage vehicle which may happen during the canister handling at the spent nuclear fuel disposal repository. For this, a rigid body dynamic analysis of the canister is executed to compute the impact force using the commercial CAE system, RecurDyn, and a nonlinear structural analysis is performed to compute stresses and deformations occurring inside the canister for this computed impact force using the commercial FEM code, NISA. From these analysis results, the structural safety of the canister is evaluated for the falling plumb down accident from the carriage vehicle due to the inattention during the canister handling at the repository. The rigid body dynamic analysis performed assuming the canister as a rigid body shows that the canister falls plumb down to the ground in two types. And also it shows that early collision impact force is the biggest one and following impact forces decrease gradually. The height of the carriage vehicle in the repository is assumed as 5m in order to obtain the stable structural safety evaluation result. The nonlinear structural analysis of the canister is executed for the biggest early impact force. The structural analysis result of the canister shows that the structural safety of the PWR canister is not secured for the falling plumb down accident from the moving carriage vehicle because the maximum stresses occurring in the cast iron insert of canister are bigger than the yield stress of the cast iron.

Failure Analysis and Heat-resistant Evaluation of Electric Fuel Pump for Combat Vehicle (전투차량용 전기식 연료펌프의 고장분석 및 내열성능 평가)

  • Kwak, Daehwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.634-640
    • /
    • 2020
  • Failure analysis and heat-resistant were performed for an electric fuel pump that is installed in the fuel tank to transfer fuel to the engine of combat vehicles. The fuel pump with a DC motor was disassembled and inspected to determine the cause of failure. The failure phenomenon was classified into three categories based on observations of the inside of the housing: burnt winding, quick brush abrasion, and fuel leak into the pump. Based on the inspection results, it was estimated that overheating was the main cause of failure. The thermal test was conducted under the no-load condition in 24 hours, and the thermal sensor was installed on the stator surface and the brush holder to check the possibility of damage to the winding due to overheating. When the ambient temperature of the fuel pump was set to 68 ℃, the stator temperature increased to 135.9 ℃, and the winding of the motor was almost damaged. The test results confirmed the lack of heat resistance of fuel pump windings, and suggested that the type F of insulation class (below 155 ℃) of the windings and varnish should be replaced with type C or higher that can be used above 180 ℃.

A Moving Control of an Automatic Guided Vehicle Based on the Recognition of Double Landmarks (이중 랜드마크 인식 기반 AGV 이동 제어)

  • Jeon, Hye-Gyeong;Hong, Youn-Sik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.8C
    • /
    • pp.721-730
    • /
    • 2012
  • In this paper the problem of a moving control of an automatic guided vehicle(AGV) which transports a dead body to a designated cinerator safely in a crematorium, an special indoor environment, will be discussed. Since a method of burying guided lines in the floor is not proper to such an environment, a method of moving control of an AGV based on infrared ray sensors is now proposed. With this approach, the AGV emits infrared ray to the landmarks adheres to the ceiling to find a moving direction and then moves that direction by recognizing them. One of the typical problems for this method is that dead zone and/or overlapping zone may exist when the landmarks are deployed. To resolve this problem, an algorithm of recognizing double landmarks at each time is applied to minimize occurrences of sensing error. In addition, at the turning area to entering the designated cinerator, to fit an AGV with the entrance of the designated cinerator, an algorithm of controlling the velocity of both the inner and outer wheel of it. The functional correctness of our proposed algorithm has been verified by using a prototype vehicle. Our real AGV system has been applied to a crematorium and it moves automatically within an allowable range of location error.

A Quantitative Risk Analysis of LPG Leaked During Cylinder Delivery (가스용기 운반 중 누출된 LPG의 정량적 위험 분석)

  • Kim B-J,;Park Ki-Chang;Lee Kuen-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.2 s.19
    • /
    • pp.33-41
    • /
    • 2003
  • There exists high hazard when transporting LPG as well as using, storing, and producing. For small scale LPG consumer, retailers deliver LPG to customers via a truck loading many LPG cylinders. Suppose there occurred a accident during LPG cylinder transfer, this could result in serious damages to the life and properties in the near or neighbor of the accident spot. In this regard, we made a quantitative risk analysis to estimate the possible damages and the probability through the identification of accidents causes and the simulation of the possible scenario. In this study, we made the Excel & Visual Basic computer program to perform quantitative LPG accident analysis. The simulation showed the following results. In case of UVCE(Unconfined Vapor Cloud Explosion), the effect within l0m of the accident spot showed very severe structural damages and even the accident can break the window glasses of the area of 150 m apart from accident spot. In case of TNT corresponding probit analysis, after 10 minutes LPG leaking, $75\%$ window glasses of 40 m distance was expected to be broken. And $16\%$ frames of 20m distance, $10\%$ frames of 40m distance was expected to be collapsed.

  • PDF

Challenges of Medical Waste Treatment in Fiji (피지국에서의 의료폐기물 처리현황과 문제점)

  • Kim, Daeseon;Bolaqace, Josefa;Rafai, Eric;Lee, Chulwoo
    • Journal of Appropriate Technology
    • /
    • v.6 no.1
    • /
    • pp.37-44
    • /
    • 2020
  • Medical waste is any kind of waste that contains infectious material and recommended not to be transferred for infection control. As a means of disposal, incineration has better points than dumping or landfill in the quantity reduction, odorless and nonhazardous. However, open burning and incineration of health care wastes under bad circumstances, can result in the emission of environmental pollutants to air. A burial of biological waste brings pollution of soil and water. Most of sub divisional hospitals in Fiji transfer their medical wastes to divisional hospitals for incineration. In 2011, 62,518 kg of medical waste was incinerated in the three divisional hospitals. However, some medical wastes are considered as general waste and burnt or sent to landfill site, some are buried on site in some sub-divisional hospitals. In this regards, urgent education is necessary for awareness promotion to relevant personnel in medical waste treatment. On site incineration using small scale incinerator is more recommended than transportation of medical wastes treatment in Fiji. Moreover, remotely controllable and fixable small scale of incinerator is more desirable in sub-divisional hospitals. It is recommended that Fiji government to set up a legal framework for medical waste management (MWM), to develop specific guidelines for MWM, to set up a training system for MWM to ensure that all relevant personnel are trained, to develop a monitoring and supervision system for MWM, to clarify the future financing of MWM activities, and to improve the MWM infrastructure.