• Title/Summary/Keyword: 이성분계 혼합물

Search Result 57, Processing Time 0.037 seconds

Measurement of flash point for binary mixtures of Ethanol, 1-propanol, 2-propanol and 2,2,4-trimethylpentane (Ethanol, 1-propanol, 2-propanol 그리고 2,2,4-trimethylpentane 이성분 혼합계에 대한 인화점 측정)

  • Hwang, In Chan;In, Se Jin
    • Clean Technology
    • /
    • v.25 no.2
    • /
    • pp.140-146
    • /
    • 2019
  • Flammable substances, such as organic solvents, are commonly used in laboratories and industrial processes. The flash point of flammable liquid mixtures is a very important parameter for characterizing the ignition and explosion hazards, and the flash points of mixtures of $C_2{\sim}C_3$ alcohols and 2,2,4-trimethylpentane were measured in the present study. The 2,2,4-trimethylpentane is an important component of gasoline and is frequently used in the petroleum industry as a solvent. Lower flash point data were measured for the binary systems {ethanol + 2,2,4-trimethylpentane}, {1-propanol + 2,2,4-trimethylpentane}, and {2-propanol + 2,2,4-trimethylpentane}. The flash point measurements were carried out according to the standard test method (ASTM D3278) using a Stanhope-Seta closed cup flash point tester. The measured flash points were compared with the predicted values calculated using Raoult's law and also following $G^E$ models: Wilson, Non-Random Two Liquid (NRTL) and UNIversal QUAsiChemical (UNIQUAC). These models were able to predict the experimental flash points for different compositions of {$C_2{\sim}C_3$ alcohols + 2,2,4-trimethylpentane} mixtures with minimal deviations. The average absolute deviation between the predicted and measured lower flash point was less than 1.28 K. A minimum flash point behaviour was observed in all of the systems as in the many observed cases for the hydrocarbon and alcohol mixtures.

Carbon Dioxide-Isopropyl Alcohol System: High Pressure Phase Behavior and Application with SAFT Equation of State (이산화탄소-이소프로필 알코올계: 고압 상거동 및 SAFT 상태방정식 적용)

  • Kwak, Chul;Byun, Hun-Soo
    • Applied Chemistry for Engineering
    • /
    • v.10 no.2
    • /
    • pp.324-329
    • /
    • 1999
  • In this work, high pressure binary phase equilibria data of carbon dioxide and isopropyl alcohol were obtained by experiment. A static type experimental apparatus was made to measure temperature, pressure and phase equilibria composition. The experimental apparatus was tested by comparing the measured phase equilibria data of the carbon dioxide-isopropyl alcohol system at $80^{\circ}C$ with those of Rodosz. The binary phase behavior data of carbon dioxide-isopropyl alcohol system were measured in range of 41 to 133 bar and at temperatures of 40, 60, 80, 100 and $120^{\circ}C$. The solubility of isopropyl alcohol increases as the temperatures increases at constant pressure. Also, these carbon dioxide-alcohol solute system have critical-mixture curves that exhibit maxima in pressure at temperatures between the critical temperatures of carbon dioxide and isopropyl alcohol. The experimental data obtained in this study were modeled using the statistical associating fluid theory(SAFT) equation of state. A good fit of the data was obtained with SAFT using two adjustable parameters for the carbon dioxide-isopropyl alcohol system.

  • PDF

Fire Extinguishing Ability of Binary Gaseous Extinguishing Agents Evaluated by Cup Burner and Numerical Studies (이성분계 가스계소화약제 소화성능의 컵버너실험 및 이론적 고찰)

  • Kwon, Kyung-Ok;Won, Dong-Bin;Choi, Keun-Joo;Kim, Jong-Won;Shin, Dong-Il
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.7-12
    • /
    • 2007
  • The search for a new fire-extinguishing agent with all the desirable properties of halon 1301 has not been successful. To study binary gaseous extinguishing agents instead, one has to determine the extinguishing concentrations for several compositions of a given chemical in an inert gas. This process is expensive and time consuming. The fire suppression efficiencies of gas mixtures of HFC 125 and HFC 227ea with nitrogen as total flooding agents were studied by cup burner method. It was shown that addition of small amounts of those extinguishants to nitrogen can enhance the suppression effectiveness of the inert gas. As expected, the degree of synergism was highest at low concentrations of the chemical. For each binary system, extinguishing concentrations of the pure compounds and one binary data were used to predict the extinguishing concentrations for the entire range of binary composition. The predicted values were very close to experimental data.

  • PDF

Toxicity Reduction of VOCs by Catalytic Oxidation Mechanism (VOCs의 촉매산화 메커니즘에 의한 독성 저감효과)

  • 이재동
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.3
    • /
    • pp.88-93
    • /
    • 2000
  • The objective of this study was to depict the kinetic behavior of the platinum catalyst for the deep oxidation of VOCs and their mixture. The oxidation characteristics of VOCs, which were benzene, toluene, and styrene, was studies on a 0.5% $Pt/{\gamma}-Al_2O_3$ catalyst. The reactivity increases in order benzene>toluene>styrene. In mixtures, remarkable effects on reaction rate and selectivity have been evident ; the strongest inhibiting effect was shown by styrene and increases in a reverse order with respect to that of reactivity. The reaction model reveals that there is a competition between the two reactants for the oxidized catalyst. Thus, the nontoxic catalytic oxidation process was suggested as the new VOCs control technology.

  • PDF

Isobaric Vapor-Liquid Equilibrium of 1-propanol and Bromochloromethane System at Subatmospheric Pressures (감압하에서 1-propanol과 Bromochloromethane의 정압 기-액 평형)

  • Jang, Hoi-Gu;Kang, Choon-Hyoung
    • Applied Chemistry for Engineering
    • /
    • v.21 no.3
    • /
    • pp.295-300
    • /
    • 2010
  • A binary system of 1-propanol and bromochloromethane which exhibits an azeotropic point and a considerable nonideal phase behavior probably due to the large boiling point difference is not amenable in the actual chemical processes such as the distillation tower and absorber. Therefore, experimental data of phase behavior data of this mixture are indispensable in understanding the inherent thermodynamic characteristics for an efficient application of the system in the industrial processes. In this work, the isobaric vapor-liquid equilibrium of a binary mixture consisting of 1-propanol and bromochloromethane was measured by using a recirculating equilibrium cell at various pressures ranging from 30 to 70 kPa. The measured VLE data were correlated in a satisfactory manner by using the UNIQUAC and NRTL models along with the thermodynamic consistency test based on Gibbs/Duhem equation. In addition, the excess molar volume of the mixture was also measured by using a vibrating densitometer and correlated with a Redlich-Kister polynomial.

Comparison of Experimental Data on the Fluctuation Integral Gij with the Calculated Results Based on the Activity Coefficient Model in Binary Mixtures Containing c-Hexane (c-hexane을 포함하는 이성분계 혼합물에서 활동도계수 모델을 이용한 변동적분 Gij의 계산 수치와 실험 수치의 비교)

  • Hur, Kwang-II;Kwon, Yong-Jung
    • Journal of Industrial Technology
    • /
    • v.20 no.A
    • /
    • pp.203-209
    • /
    • 2000
  • The fluctuation integrals which give useful information in the structure of solution are associated with the mixed direct correlation integral ($C_{12}$) known. Using its weighted arithmetic mean of $C_{11}$ and $C_{22}$ and the activity coefficient model, the fluctuation integrals on solute-solute, solvent-solute, and solvent-solvent can be calculated in the function of mole fraction. In this work, several binary mixtures containing c-hexane were tested and the results on the fluctuation integrals were rather good.

  • PDF

Kinetics Prediction of Binary Aromatic Solvent Mixtures in Catalytic Oxidation Process (방향족 유기용매의 촉매산화공정에서 이성분계 혼합물의 속도특성 예측)

  • 이승범;윤용수;홍인권;이재동
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.1
    • /
    • pp.66-71
    • /
    • 2001
  • The objective of this study was to depict the kinetic behavior of the platinum catalyst for the deep oxidation of aromatic solvents and their binary mixtures. The oxidation kinetics of aromatic solvents, which were benzene, toluene and m-xylene, was studied on a 0.5% $Pt/{\gamma}-Al_2O_3$ catalyst. Deep oxidation of binary mixtures, which were 1:1 in volume, was carried out and the inlet concentration was controlled in the range of 133 and 333ppmv. An approach based on the two-stage redox model was used to analysis the results. The deep oxidation conversion of aromatic solvents was inversely proportional to inlet concentration in plug flow reactor. This trend is due to the zeroth-order kinetics with respect to inlet concentration. The kinetic parameters of multicomponent model were independently evaluated from the single compound oxidation experiments. A simple multicomponent model based on two-stage redox rate model made reasonably good predictions of conversion over the range of parameters studied.

  • PDF

Measurement and Prediction of Autoignition Temperature(AIT) of n-Decane+Ethylbenzene System (노말데칸과 에틸벤젠 계의 최소자연발화온도 측정 및 예측)

  • Lee, Jae-Hwa;Kim, Gui-Ju;Hong, Soon-Kang;Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.5
    • /
    • pp.54-60
    • /
    • 2015
  • The autoignition temperature (AIT) of a material is the lowest temperature at which the material will spontaneously ignite. The AIT is important index for the safe handling of flammable liquids which constitute the solvent mixtures. This study measured the AITs of n-decane+ethylbenzene system by using ASTM E659 apparatus. The AITs of n-decane and ethylbenzene which constituted binary system were $210^{\circ}C$ and $430^{\circ}C$, respectively. The experimental AITs of n-decane+ethylbenzene mixture were a good agreement with the calculated AITs by the proposed equations with about $11^{\circ}C$ A.A.D.(average absolute deviation).

Dew Point Prediction by Lower Flash Points of Binary Mixtures (이성분계 혼합물의 하부 인화점에 의한 이슬점 예측)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.34-39
    • /
    • 2017
  • Vapor-liquid equilibrium calculation is required to properly design and operation of distillation process. The general calculation method is to use binary interaction parameter. Lower flash points of cyclohexanol+aniline and cyclohexanol+cyclohexanone were measured by using Seta-flash closed cup apparatus. The measured flash points were compared with those calculated by the method based on Raoult's law and the optimization method using Wilson equation. The absolute average errors(A.A.E.) of the results calculated by Raout's law are $0.25^{\circ}C$ and $1.07^{\circ}C$ for cyclohexanol+aniline and cyclohexanol+cyclohexanone, respectively. The absolute average errors of the results calculated by the optimization method are $0.22^{\circ}C$ and $0.65^{\circ}C$ for cyclohexanol+aniline and cyclohexanol+cyclohexanone, respectively. As can be seen from A.A.E., the calculated values based on the optimization method were found to be better than those based on the Raoult's law. The binary interaction parameters calculated by the optimization method are used to predict the dew points of cyclohexanol+aniline and cyclohexanol+cyclohexanone. The A.A.E. for these mixtures show that there is an acceptable agreement between experimental and calculated dew poins.

Measurement and Prediction of the Flash Point for the Flammable Binary Mixtures using Tag Open-Cup Apparatus (Tag식 개방계 장치를 이용한 가연성 이성분계 혼합물의 인화점 측정 및 예측)

  • Ha, Dong-Myeong;Lee, Sungjin;Song, Young-Ho
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.181-185
    • /
    • 2005
  • The flash point is one of the most important combustible properties used to determine the potential for fire and explosion hazards of industrial material. An accurate knowledge of the flash point is important in developing appropriate preventive and control measures in industrial fire protection. The flash points for the n-butanol+n-propionic acid and n-propanol+n-propionic acid systems were measured by using Tag open-cup apparatus(ASTM D 1310-86). The experimental data were compared with the values calculated by the laws of Raoult and van Laar equation. The calculated values based on the van Laar equation were found to be better than those based on the Raoult's law.