• 제목/요약/키워드: 이상 냉매 유동

검색결과 16건 처리시간 0.031초

수평 T형 분지관 내 냉매 이상유동 분배특성에 미치는 변수들의 영향 (Effect of Parameters on the Two-Phase Flow Distribution Characteristics of Refrigerants in a Horizontal T-Junction)

  • 태상진;조금남
    • 설비공학논문집
    • /
    • 제18권1호
    • /
    • pp.31-37
    • /
    • 2006
  • The present study has been experimentally investigated the effect of geometric and operating parameters on the two-phase flow distribution of refrigerants in a horizontal T-junction. The operating parameters were the kind of refrigerants (R-22, R- l34a, and R-410A), saturated temperature, and the inlet mass flux and quality. The geometric parameters were the tube diameter and the tube diameter ratio. The measured data of refrigerants were compared with the values predicted using the models developed by several researchers for air/water or steani/water two-phase flow. Among the operating parameters, the inlet Quality was the most sensitive to the mass flow rate ratio. Between the geometric parameters, the tube diameter ratio was more sensitive than tube diameter.

수평 전열관내 냉매의 이상유동 압력강하에 관한 연구 (A Study on Pressure Drop in Two-Phase Flow Boiling of Refrigerants in Horizontal Tube)

  • 임태우;김준효
    • 설비공학논문집
    • /
    • 제15권6호
    • /
    • pp.510-517
    • /
    • 2003
  • An experimental study on the pressure drop during flow boiling for pure refrigerants R134a and Rl23, and their mixture was carried out in a uniformly heated horizontal tube. Tests were run at a pressure of 0.6 MPa and in the ranges of heat flux 5~50 kW/m$^2$, vapor quality 0~100 percent and mass velocity of 150~600 kg/m$^2$s. Generally, the two-phase frictional multiplier is used to predict the frictional pressure drop during the two-phase flow boiling. The obtained results have been compared to the existing various correlations for the two-phase multiplier. Also, the frictional pressure drop was compared to a few available correlations; The Lockhart-Martinelli correlation considerally overpredicted the frictional pressure drop data for mixture as well as pure components in the entire mass velocity ranges employed in the present study, while the Chisholm correlation underpredicted the present data. The Friedel correlation was found to satisfactorily correlate the frictional pressure drop data except for a low quality region.

증발 지연 구간을 포함한 비단열 모세관에서의 냉매 유동 특성 예측을 위한 시뮬레이션 (A Simulation for predicting the Refrigerant Flow Characteristics Including Metastable Region in Non-Adiabatic Capillary Tubes)

  • 손기동;박상구;정지환;김윤수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.263-270
    • /
    • 2008
  • The capillary tube/suction line heat exchanger (SLHX) is widely used in small refrigeration systems. The refrigerant flowing in the SLHX experiences frictional and accelerational head losses, flashing, and heat transfer simultaneously. The simulation of refrigerant flow through SLHX is important since this will help engineers analyze and optimize the SLHX incorporated in a refrigeration system. The present SLHX model is based on conservation equations of mass, momentum and energy. Also a meta-stable model is included. All these equations are solved simultaneously. In this paper, HFC-134a refrigerant flow through a non-adiabatic capillary tube is simulated. The simulation results are discussed but not validated against experimental measurements yet.

  • PDF

수평 평활관내 R404A와 R152a 냉매 유동의 응축 열전달 계수에 대한 비교 연구 (Comparative Study of Condensation Heat Transfer Coefficients between R404A and R152a Flow in a Horizontal Smooth Tube)

  • 이상용;김만희;이치영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.256-261
    • /
    • 2005
  • In the present experimental study, condensation heat transfer coefficients between R404A and R152a flow in a horizontal smooth tube were compared. The outer and inner diameters of the tube were 9.52 mm and 7.55 mm, respectively, and the heated length was 1045 mm. The mass flux ranged from 150 to 400 $kg/m^{2}s$ and the test section were uniformly heated from 8 to 12. $kW/m^2$. The quality range was from 0.2 to 0.8 at the saturation temperature from 27.3 to $34^{\circ}C$. Experimental condensation heat transfer coefficients increased as the quality and mass flux increased. Modified Dobson and Chato correlation reduced the mean deviation of 5.1% for R404A and 9.4% for R152a than the original correlation$^{(2)}$.

  • PDF

마찰 계수와 점성 계수 모델이 단열 모세관 유동에 미치는 영향 평가 (An Assessment of Friction Factor and Viscosity Models for Predicting the Refrigerant Characteristics in Adiabatic Capillary Tubes)

  • 손기동;박상구;정지환;이승홍;김윤수
    • 설비공학논문집
    • /
    • 제21권3호
    • /
    • pp.140-148
    • /
    • 2009
  • Capillary tubes are widely used as expansion device in small refrigeration systems. The refrigerant flowing in the capillary tube experiences frictional and accelerational head losses and flashing simultaneously. In this paper flow characteristics of adiabatic capillary tubes were simulated with various friction factor models, two-phase viscosity models, and two-phase frictional multiplier models. The predicted pressure distribution and mass flow rate are compared with experimental data reported in literature. It is confirmed that the predicting accuracy with homogeneous model can be improved by employing suitable correlations of friction factor, two-phase viscosity and two-phase frictional multiplier.

마찰 계수와 점성 계수 모델이 단열 모세관 유동에 미치는 영향 평가 (An assessment of friction factor and viscosity models for predicting the refrigerant characteristics in adiabatic capillary tubes)

  • 손기동;박상구;정지환;김윤수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.47-54
    • /
    • 2008
  • Capillary tubes are widely used as expansion device in small refrigeration systems. The refrigerant flowing in the capillary tube experiences frictional and accelerational head losses, and flashing, simultaneously. In this paper flow characteristics of adiabatic capillary tubes with various friction factor models, two-phase viscosity models, and two-phase frictional multiplier models were simulated. The predicted pressure distribution, mass flow rate are compared with experimental data reported in literature. It is confirmed that the predicting accuracy with homogeneous model can be improved by employing the suitable correlations of friction factor and two-phase viscosity model, and two-phase frictional multiplier.

  • PDF

R134a 및 Rl23과 비공비 혼합냉매 R134a/R123의 수평관내 이상유동양식에 관한 연구 (A Study on Two-Phase Flow Pattern of Pure Refrigerants R134a and Rl23 and Zeotropic Mixture R134a/R123 in Horizontal Tubular)

  • 임태우;김준효
    • 대한기계학회논문집B
    • /
    • 제27권8호
    • /
    • pp.1033-1041
    • /
    • 2003
  • Two-phase flow pattern data during horizontal in-tube flow boiling are presented for pure and mixed refrigerants of R134a and Rl23, The flow pattern is observed through tubular sight glasses located at inlet and outlet of the test section, which is made of a stainless steel tube, 2m long with 10mm I.D., 1.5mm wall thickness. The obtained results are compared with the available various correlations for flow pattern. The flow pattern map of Hashizume was in good agreement with the present data except the region of low mass velocity. Weisman flow pattern map was also known to satisfactorily predict data for refrigerants in the region of annular flow. In this study, the flow pattern are simply classified into two groups; stratified(including intermittent, stratified and stratified-wavy) flow and annular flow. The transition quality from stratified to annular flow was obtained by modifying the liquid Froude number.

마이크로채널 반응기를 이용한 강화된 저온 피셔-트롭쉬 합성반응의 전산유체역학적 해석 (Intensified Low-Temperature Fischer-Tropsch Synthesis Using Microchannel Reactor Block : A Computational Fluid Dynamics Simulation Study)

  • ;나종걸;박성호;정익환;이용규;한종훈
    • 한국가스학회지
    • /
    • 제21권4호
    • /
    • pp.92-102
    • /
    • 2017
  • 피셔-트롭쉬 합성반응은 CO와 H2의 혼합가스로 이루어진 합성가스를 부가가치가 높은 탄화수소 제품으로 변환시킨다. 본 논문에서는 저온 피셔-트롭쉬 합성반응과 단일, 다중 마이크로채널 반응기에 패킹시킨 촉매를 기반으로 강화된 반응조건의 열전달을 고려하여 전산유체역학 기반의 시뮬레이션을 진행하고 분석하였다. 단일채널모델을 통하여 CO 전환률이 ~65% 이상, $C_{5+}$ 선택도가 ~74% 이상을 달성하면서도 Co 기반의 super-active 촉매를 통해 GHSV를 $30000hr^{-1}$을 달성할 수 있음을 보였다. 다중 마이크로채널 반응기모델에서는 열전달 시뮬레이션을 동시에 해석하여, 3가지의 다른 반응기구조에 대해서, 직교류 wall boiling 냉매를 사용시 ${\Delta}T_{max}$가 23 K였으며 평행유동 subcooled 냉매와 평행유동 wall boiling 냉매의 경우 각각 15 K와 13 K의 ${\Delta}T_{max}$를 보였다. 반응기 전체적으로 498 - 521 K에서 온도제어가 가능했으며 계산된 사슬성장 가능성은 저온 피셔-트롭쉬 합성에 적합한 것으로 보인다.