• Title/Summary/Keyword: 이상유체

Search Result 914, Processing Time 0.025 seconds

Analytical Methods of Leakage Rate Estimation from a Containment tinder a LOCA (냉각수상실 사고시 격납용기로부터 누출되는 유체유량 추산을 위한 해석적 방법)

  • Moon-Hyun Chun
    • Nuclear Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.121-129
    • /
    • 1981
  • Three most outstanding maximum flow rate formulas are identified from many existing models. Outlines of the three limiting mass flow rate models are given along with computational procedures to estimate approximate amount of fission products released from a containment to environment for a given characteristic hole size for containment-isolation failure and containment pressure and temperature under a loss of coolant accident. Sample calculations are performed using the critical ideal gas flow rate model and the Moody's graphs for the maximum two-phase flow rates, and the results are compared with the values obtained from the mass leakage rate formula of CONTEMPT-LT code for converging nozzle and sonic flow. It is shown that the critical ideal gas flow rate formula gives almost comparable results as one can obtain from the Moody's model. It is also found that a more conservative approach to estimate leakage rate from a containment under a LOCA is to use the maximum ideal gas flow rate equation rather than tile mass leakage rate formula of CONTEMPT-LT.

  • PDF

Relationships between Micronutrient Contents in Soils and Crops of Plastic Film House (시설재배 토양과 작물 잎 중의 미량원소 함량 관계)

  • Chung, Jong-Bae;Kim, Bok-Jin;Ryu, Kwan-Sig;Lee, Seung-Ho;Shin, Hyun-Jin;Hwang, Tae-Kyung;Choi, Hee-Youl;Lee, Yong-Woo;Lee, Yoon-Jeong;Kim, Jong-Jib
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.3
    • /
    • pp.217-227
    • /
    • 2006
  • Micronutrient status in soils and crops of plastic film house and their relationship were investigated. Total 203 plastic film houses were selected (red pepper, 66; cucumber, 63; tomato, 74) in Yeongnam region and soil and leaf samples were collected. Hot-water extractable B and 0.1 N HCl extractable Cu, Zn, Fe, and Mn in soil samples and total micronutrients in leaf samples were analyzed. Contents Zn, Fe, and Mn in most of the investigated soils were higher than the upper limits of optimum level for general crop cultivation. Contents of Cu in most soils of cucumber and tomato cultivation were higher than the upper limit of optimum level, but Cu contents in about 30% of red pepper cultivation soils were below the sufficient level. Contents of B in most soils of cucumber and tomato were above the sufficient level but in 48% of red pepper cultivation soils B were found to be deficient. Micronutrient contents in leaf of investigated crops were much variable. Contents of B, Fe, and Mn were mostly within the sufficient levels, while in 71% of red pepper samples Cu was under deficient level and in 44% of cucumber samples Cu contents were higher than the upper limit of sufficient level. Contents of Zn in red pepper and cucumber samples were mostly within the sufficient level but in 62% of tomato samples Zn contents were under deficient condition. However, any visible deficiency or toxicity symptoms of micronutrients were not found in the crops. No consistent relationships were found between micronutrient contents in soil and leaf, and this indicates that growth and absorption activity of root and interactions among the nutrients in soil might be important factors in overall micronutrient uptake of crops. For best management of micronutrients in plastic film house, much attention should be focused on the management of soil and plant characteristics which control the micronutrient uptake of crops.

Polymer magnetic separator for biosensor applications (바이오센서 응용을 위한 자기 분리장치)

  • Kang, Moon-Sik;Kim, Yun-Ho;Yu, Geum-Pyo;Min, Nam-Gi;Hong, Suk-In
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2117-2120
    • /
    • 2004
  • 본 논문은 UV-LIGA 공정, 후막공정을 이용한 바이오센서용 magnetic bead 분리 장치의 제작 기술개발에 관한 것이다. 최근 MEMS(microelectromechanical system) 기술을 이용한 바이오센서에 대한 연구가 활발하게 이루어지고 있다. 이러한 바이오센서 분야 중 혈액이나 다른 원하지 않는 물질을 분리해 주는 분리장치는 MEMS 기술을 이용해 구현이 매우 어려운 부분 중에 하나이다. 기존의 UV-LIGA 공정과 도금법을 이용한 마이크로 전자석 제작하여 분리장치를 제작하는 경우 제작 공정이 매우 복잡하며 매우 많은 공정비용을 요구한다. 이러한 단점을 해결하기 위해 본 논문에서는 Sr 계연의 고분자 자석과 3차원 PDMS(poly-dimethylsiloxane) 마이크로 채널 공정을 이용해 분리장치를 제작하였다. 제작된 분리장치는 $0{\sim}30{\mu}{\ell}$/min 의 속도에서 유체를 흘렸을 90% 이상의 분리 효율을 나타냈다. 개발된 분리 장치는 연재질의 PDMS 로 제작되어 일회용 바이오센서에 적용이 가능하다.

  • PDF

Fast Volume Rendering of VKH dataset using GPU Cluster (GPU 클러스터를 이용한 VKH 데이터의 빠른 볼륨 렌더링)

  • Lee Joong-Youn
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.11a
    • /
    • pp.763-765
    • /
    • 2005
  • 볼륨 렌더링은 3차원이나 그 이상의 차원의 볼륨 데이터에서 의미있는 정보를 추출해 내어 직관적으로 표출하는 가시화 기법을 말하며 의료영상 기상학, 유체역학 등 다양한 분야에서 널리 사용되고 있다. 한편, 최근 PC 하드웨어의 급격한 발전으로 과거에는 슈퍼컴퓨터에서나 가능했던 대용량 볼륨 데이터의 가시화가 일반 PC 환경에서도 가능하게 되었다. PC 그래픽스 하드웨어의 꼭지점 및 픽셀 세이더의 수치 계산에 최적화된 벡터 연산으로 빠른 볼륨 가시화를 가능하게 한 것이다. 그러나 그래픽스 하드웨어의 메모리 용량의 한계로 대용량의 볼륨 데이터를 빠르게 가시화하는 것은 지금까지 어려운 문제로 남아있다. 본 논문에서는 한국과학기술정보연구원에서 제작한 대용량의 인체영상 데이터인 Visible Korean Human 데이터를 여러 개의 그래픽스 하드웨어 메모리에 분산시키고 이를 꼭지점 및 픽셀 쉐이더를 이용하여 빠르게 가시화하여 고해상도의 이미지를 얻고자 하였다.

  • PDF

Low Noise Characteristics of the Comformal Sensor Array's Support Structure (곡면배열 센서의 저소음화를 위한 지지구조 설계 구조)

  • Lee, Jong-Kil;Lee, Sang-Won;Seo, Hee-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.340-341
    • /
    • 2010
  • Noise reduction is an important factor to design low noise sensor array. In this paper three layers of the de-coupler in the conformal sensor array were used to investigate noise reduction. Conformal sensor array is positioned in the layers and the distance from the layer is 0.25cm~1.5cm. Transfer function in the frequency density function is investigated according to the three different positions. When increasing the embedded distance the flow noise decreased in the region of the kx>10.

  • PDF

Numerical Simulations of Cavitation Flow in Volumetric Gear Pump (회전 용적형 기어펌프의 캐비테이션 유동 해석)

  • Lee, Jung-Ho;Lee, Sang-Wook
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.4
    • /
    • pp.28-34
    • /
    • 2011
  • A volumetric gear pump is often used in extensive industrial applications to provide both high pressure and sufficiently high flow rate by physical displacement of finite volume of fluid with each revolution. Template mesh function in commercial CFD software, PumpLinx, by which 3-D meshes in the complex region between rotor and housing can be readily generated was employed for 3-D flow simulations. For cavitation analysis full cavitation model was included in 3-D simulations. The results showed high pulsation in pressure and flowrate which is implicated in pump vibration and noise. A model test for cavitation visualization was conducted and the results showed good qualitative agreement with numerical prediction.

Turbomolecular Pump 내 Rotor-Stator의 형상 변화에 따른 유동의 수치적 해석

  • Kim, In-Chan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.98-98
    • /
    • 2012
  • 최고진공도 10-10 mbar, 배기속도 2500 L/s를 구현할 대용량 복합 분자펌프(TMP) 설계를 위한 3차원 유동해석을 실시하였다. 진공도가 10-5 mbar 이상이 되는 고진공도에서는 Knudsen 수가 102~107에 이르러 분자간 충돌을 거의 무시할 수 있게 되며, 이때의 유체해석 방법으로서는 통상 희박기체 해석법으로 많이 쓰이는 Direct Simulation Monte Carlo (DSMC) 방법이나 Continuum fluid에 대한 Navier-Stokes 해석보다, 충돌이 없는 분자의 자유운동을 모사하는 Monte Carlo 방법이 더 적합할 수 있다. 본 연구에서는 다단계 rotor와 stator로 구성되는 복합분자 내 유동장에 Monte Carlo 해석법을 적용하여 유동해석을 실시하였다. 해석 방법의 타당성을 확인하기 위해 동일한 형상에 대해 Navier-Stokes 해석과 DSMC 해석을 병행하였다. 각각의 수치적 해석에서 공통적으로, TMP의 성능에 지배적인 영향을 미치는 설계변수는 rotor-stator의 날개각임이 확인되었고, 이 설계변수들의 최적값을 다양한 3차원 유동해석을 통해 도출하였다. 해석결과는 펌프설계에 적용되어 펌프 성능시험결과를 통해 확증된다.

  • PDF

Structural optimization and numerical analysis of multiphysics system (멀티 피직스 시스템 해석과 구조 최적 설계)

  • Yoon, Gil-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.157-160
    • /
    • 2009
  • 멀티 피직스 시스템은 구동을 수치적으로 해석하기 위하여 두 개 이상의 연성이 되어 있는 물리계를 고려해야하는 시스템을 일컫는다. 대표적인 예로 기계 분야에서 현재까지 많이 연구되어 왔던 열탄성(Thermal/Structure)과 유체/구조 연성(Fluid/Structure)시스템을 들 수 있다. 또한 현재 차세대 성장산업으로 많은 관심이 집중되고 있는 의료기기나 지능형 자동차와 로봇 등에서 사용되는 다양한 센서와 엑추에이터 등도 특별한 예로 들 수 있다. 특히, 한 개의 물리계 해석으로 시스템 해석이 가능한 기존의 일반적인 기계 시스템과는 달리 MEMS 등의 초소형 시스템은 시스템의 거동을 수치적으로 계산하기 위하여 여러 물리계의 연성을 고려해야 한다는 점에서 대표적인 다물리계 시스템의 예로 들 수 있다. 이렇게 우리생활에 밀접하게 쓰이고 있는 멀티 피직스 시스템은 단일 물리계 시스템과 비교하여 엔지니어의 경험에 의존하여 설계(Design)하기가 어려운 특성이 있다. 이에 이 연구 논문에서는 이런 멀티 피직스 시스템을 해석하고 최적화 하기위한 노력을 소개한다.

  • PDF

Numerical Study on Improvement of Mixing Equipment' Plan in a Water Treatment Plant (수리해석을 이용한 정수장내 혼화장치 설계 개선에 관한 연구)

  • Oh, S.Y.;Hyun, D.S.;Oh, J.J.;Lee, S.H.;Lee, N.Y.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.777-782
    • /
    • 2001
  • In this study, we used In-line orifice mixer for efficient chemicals mixing in water treatment. The method of using In-line orifice mixer has been already proved the improvement of water treatment efficiency. Numerical study was performed using FLUENT, a commercial code, to standard design and production of effective In-line orifice mixer. As variable for exactly standardizing, a proper ratio between an outer diameter of cone and a diameter of pipe, a distance between cone and orifice, a determination of orifice diameter for an optimal mixing, a distance between injection nozzle's position and cone, Numerical study has been performed for optimal standard and analyzed flow field on a basis of turbulent intensity in an orifice downstream.

  • PDF

Study on the Flow Characteristics around a Barge in Still Water (정수중 부선 주위의 유동 특성에 관한 연구)

  • Lee, Sang-Min;Jeong, Uh-Cheul;Kim, Hyun-Soo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2010.04a
    • /
    • pp.345-346
    • /
    • 2010
  • 본 연구에서는 모형실험 및 수치계산에 의해 정수중 부선 주위의 유통해석을 실시하였으며, 이를 통하여 객관적이고 정량적으로 부선의 저항추진 성능을 파악할 수 있었다. 먼저 희류수조에서 모형실험을 실시한 후, 실험에서 얻어진 데이터와의 비교를 통한 CFD의 유효성을 검증하고, 다른 형태의 예부선 선박 주위의 유동장 계산에 적용시켜 해결할 수 있는 가능성을 확인 하였다. 부선의 선수 형상에 의하여 저속일 때 25% 정도의 저항이 차이나는 현상을 모형실험을 통하여 파악할 수 있었으며, 유효마력은 7kts부터 급격히 증가하므로 적재상태별 경제적인 운항속력을 선정하여 효율적인 예부선 업무를 수행해야 할 것으로 판단된다.

  • PDF