• Title/Summary/Keyword: 이산화탄소 센서

Search Result 81, Processing Time 0.046 seconds

The Application of CO2 and Hydrometer Sensor for Development of Real Time Measuring Method on CO2 Emission of Construction Equipment (건설장비의 CO2배출량 실시간 측정방법 개발을 위한 CO2 및 유속센서의 활용)

  • Jang, Won-Suk;Kim, Byung-Soo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.2
    • /
    • pp.78-86
    • /
    • 2013
  • The researches for reduce $CO_2$ are going along animatedly in hole industry area. In construction area, the researches to minimize $CO_2$ emission are progressing variously. The researches to minimize $CO_2$ emission based on $CO_2$ emission. The method measuring $CO_2$ emission are using $CO_2$ emission coefficient on fuel consumption, LCA and an inter-industry relation table. Especially, the methods using the carbon emission coefficient based on fuel consumption are 3 types(Tier1~Tier3) of IPCC. Present, the most using method(Tier1) is using the fuel consumption and the carbon emission coefficient. But because this method do not effect each vehicle distance and driving environment, we can't calculate right $CO_2$ emission. Especially construction project's $CO_2$ emission could be different by project's characteristic. However, we can't apply these difference with present methods. So we need methodology calculating $CO_2$ emission by applying personal project's characteristic and these methodology's most important things is directly measuring $CO_2$ emission of construction equipment which use energy. The object of this study is to develop the $CO_2$ emission calculation methodology which occur in construction process, is to suggest ways to measure in real time $CO_2$ emission from construction equipment.

The study of smart farm sensing device in Jeonbuk province (전북지역 스마트 온실의 센서 활용에 대한 연구)

  • Lee, Choong Ho;Kim, H.Y.;Jung, Y.J.;Yang, S.H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.134-134
    • /
    • 2017
  • 전북지역의 130여개 스마트온실 중에서 주요한 10여개의 주요 온실에 대한 온습도, 이산화탄소, 광센서 및 기타 센서의 사용실태에 대한 조사를 수해하였다(2016년 9월~12월). 온실의 선정은 온실의 종류(비닐/유리)와 복합제어기 종류(국산/외산)를 중심으로 조사하였다. 국내외 업체의 장단점, 스마트기기의 활용과 문제점, 클라우드 기반의 3세대 한국형 스마트온실의 적용기반에 대한 조사를 수행하였다. 융복합 제어기와 센서는 자체의 신뢰성 이외에 운용상의 알고리즘 차이에서 오는 문제로 인해 농가에서 측정결과에 대한 신뢰성이 낮고, 측정이 부정확하고 일일측정 데이터에 대한 활용이 어렵고, 설정 값을 사용자가 직접 계산하고 값들을 입력해주어야 한다는 단점에 대한 의견이 대부분이다. 외국 제품은 데이터 측정값의 활용이 용이하고 복합 환경 상황에 알맞게 자동 계산 시스템이 체계적으로 작동하여 제어에 반영되며 국내 업체 설정 값의 범위보다 세밀하게 설정이 가능하다는 장점이 있으나 설치비용이 국내대비 3~4배 높고 고장 시 A/S가 느린 편이며 영어로 구성된 복잡한 시스템이기 때문에 100% 활용하기 어렵다는 단점이 있다. 스마트기기 활용은 복합 환경제어를 하는 농가이면 국내 업체와 외국 업체 모두 활용하고 있으며 주로 스마트 폰으로 사용되고 전용 어플이 아닌 PC원격 제어 소프트웨어인 팀뷰어(Teamviewer)를 이용하여 복합제어기 PC를 직접 조작하여 사용한다. 클라우드 활용으로는 복합환경제어기 회사에서 작물별 제어 방법과 데이터 정보를 제공하지 않는 점에 대한 농가의 불편함이 많은 편으로 작물별 농사방법이 많고 지역별 농사방법이 다르기 때문에 조사한 전북지역의 농가 10곳 모두 클라우드를 사용하지 않는 것으로 조사되었다. 다양한 온실 및 생육환경에 따른 표준화된 운영의 문제점을 개선하여 스마트팜에서 중요한 역할을 수행하는 복합센서의 표준시험방법과 절차를 개발하여 관련산업의 발전에 응용할 필요성이 있으며 단순한 하드웨어의 표준화 또는 개선방향보다는 농가의경험과 누적된 토양,작물 등의 재배 생육정보를 이용한 작물생육모델과 온실모델의 일치를 통해 센서-생육환경예측-검증방법의 포준화가 필요한 것으로 사료된다.

  • PDF

Non-dispersive infrared carbon dioxide sensor with an externally exposed optical cavity (광 도파관이 외부로 노출된 구조를 가지는 비분산적외선 이산화탄소 센서)

  • Jung, Dong Geon;Lee, Junyeop;Do, Nam Gon;Jung, Daewoong
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.456-460
    • /
    • 2021
  • In this study, a Non-Dispersive Infrared (NDIR) Carbon Dioxide (CO2) sensor with an externally exposed optical cavity is proposed for improving sensitivity. NDIR CO2 sensors with high performance must use a lamp-type infrared (IR) source with a strong IR intensity. However, a lamp-type IR source generates high thermal energy that induces thermal noise, interfering with the accuracy of the CO2 concentration measure. To solve this problem, the optical cavity of the NDIR CO2 sensor is exposed to quickly dissipate heat. As a result, the proposed NDIR CO2 sensor has a shorter warm-up time and a higher sensitivity compared to the conventional NDIR CO2 sensor.

Corona19 Quarantine Bus Shelter with CO2 and Body Temperature Sensor (CO2 센서와 체온 센서를 이용한 코로나19 방역 버스 쉘터)

  • Park, Byeong-Yoon;Lee, Hyeon-Min;Tran, Van-Son;Nguyen, Minh-Tuan;Lee, Boong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.5
    • /
    • pp.981-990
    • /
    • 2021
  • Corona 19 quarantine is often not implemented at degraded bus stops. We conducted this study to improve these problems. The inside and outside of the shelter can be sterilized with UV photocatalyst coating to maintain a hygienic and clean shelter, and passengers can breathe smoothly by reducing carbon dioxide in the shelter using CO2 sensors and fans. It is also expected that the body temperature can be measured using a body temperature sensor to prevent more than 20% of the spread of the coronavirus in the shelter by isolating suspected coronavirus patients in the first place. When the temperature measurement distance was less than 10cm, the accuracy of the temperature measurement was 98.9%. You can communicate your intention to ride safely and clearly without contacting the bus driver by using a ride bell that uses wireless communication inside the shelter.

Design of a Greenhouse Monitoring System using Arduino and Wireless Communication (아두이노와 무선통신을 이용한 온실 환경 계측 시스템 설계)

  • Sung, Bo Hyun;Cho, Young-Yeol
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.452-459
    • /
    • 2022
  • One of the important factors among the smart farm factors is environmental measurement. This study tried to design an environmental measurement monitoring system through Bluetooth wireless communication with LoRa using the open source programs Arduino, App Inventor, and Node Red. This system consists of Arduino, LoRa shield, temperature and humidity sensor (SHT10), and carbon dioxide sensor (K30). The environmental measurement system is configured as a system that allows the sensor to collect environmental data and transmit it to the user through wireless communication to conveniently monitor the farm environment. As libraries used in the Arduino program, LoRa.h, Sensirion.h, LiquidCrystal_I2C.h and K30_I2C.h were used. When receiving environmental data from the sensor at regular intervals, coding using average value was used for data stabilization. An Android-based app was developed using Node Red and App Inventor program as the user interface. It can be seen that the environmental data for the sensor is well collected with the screen output to the serial screen of Arduino, the screen of the smartphone, and the user interface of Node Red. Through these open source-based platforms and programs will be applied to various agricultural applications.

Speculation of Optical Cavity for Improving Optical Gas Sensor's Characteristics (광학적 가스센서 특성 향상을 위한 광 공동 구조의 고찰)

  • Yi, Seung-Hwan;Park, Jong-Seon
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.4
    • /
    • pp.63-68
    • /
    • 2008
  • This paper describes about the simulation and the experimental results of optical cavity with curved mirror surface and vertical mirror surface to improve the light intensity and efficiency of the optical sensors. When we use the vertical mirror surface, the distribution of light reached to the filter surface of detector shows an elliptical shape. Whereas, the curved mirror surface focuses the light into circular shape. Therefore, due to focusing effects in case of using curved mirror surface, the light intensity per unit area has been improved. Consequently, the output voltage of gas sensor has been expected to increase. Based upon the simulation, the experiment of gas sensor has been conducted with $CO_2$ gas from 0ppm to 2,500 ppm at 250 ppm step and $25^{\circ}C$, 45%R.H. ambient. The output voltage of gas sensor that has a curved mirror surface increases approximately 200 mV than that of vertical mirror surface.

  • PDF

An implementation of NDIR type $CO_2$ gas sample chamber and measuring hardware for capnograph system in consideration of the time response characteristics (시간응답특성을 고려한 2광원 1센서 방식의 capnograph 시스템용 NDIR식 $CO_2$ 가스 챔버 설계 및 측정 회로의 구현)

  • Park, I.Y.;Lee, I.K.;Lee, S.K.;Kang, K.M.;Kang, S.W.;Cho, J.H.
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.5
    • /
    • pp.279-285
    • /
    • 2001
  • The capnograph system for determining the partial pressure of carbon dioxide in the blood of a patient was developed based on the NDIR(non-dispersive infrared) absorption technology. NDIR gas analyzing method requires an optical absorption chamber and signal processing hardware. In this paper, we have designed and implemented NDIR type $CO_2$ gas chamber in consideration of the time response characteristics and lamp chopping frequency. And we have implemented signal processing hardware using two infrared sources to reduce the thermal background effect. The implemented gas chamber and signal processing hardware were tested in the temperature variation experiment and human expiratory experiment. The results showed that the system could produce a stable output signal and a good $CO_2$ gas concentration curve like a typical capnogram.

  • PDF

Temperature Dependency of Non-dispersive Infrared Carbon Dioxide Gas Sensor by using Infrared Sensor for Compensation (보상용 적외선 센서를 사용한 비분산 적외선 이산화탄소 센서의 온도특성)

  • Yi, SeungHwan
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.124-130
    • /
    • 2016
  • NDIR $CO_2$ gas sensor was built with ASIC implemented thermopile sensor which included temperature sensor and unique elliptical waveguide structures in this paper. The temperature dependency of dual infrared sensor module ($CO_2$ and reference IR sensors) has been characterized and its output voltage characteristics according to the temperature and gas concentration were proposed for the first time. NDIR $CO_2$ gas and reference IR sensors showed linear output voltages according to the variation of ambient temperatures from 243 K to 333 K and their slopes were 14.2 mV/K and 8.8 mV/K, respectively. The output voltages of temperature sensor also presented a linear dependency according to the ambient temperature and could be described with V(T)=-3.191+0.0148T(V). The output voltage ratio between $CO_2$ and reference IR sensors revealed irrelevant to the changes of ambient temperatures and gave a constant value around 1.6255 with standard deviation 0.008 at 0 ppm. The output voltage of $CO_2$ gas sensor at zero ppm $CO_2$ gas consisted of two components; one is caused by the HPB (half pass-band) of IR filter and the other is attributed to the part of $CO_2$ absorption wavelength. The characteristics of output voltages of $CO_2$ gas sensor could be accurately modeled with three parameters which are dependent upon the ambient temperatures and represented small average error less than 1.5% with 5% standard deviation.

Implement of Analysis system with Indoor Environment Monitoring Based on IoT (사물인터넷 기반 실내 환경 모니터링 분석 시스템 구현)

  • Nam, Jae-hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.12
    • /
    • pp.1687-1692
    • /
    • 2019
  • In the era of the fourth industrial revolution, advanced technologies such as the Internet of Things(IoT) and big data are emerging. However, the level of application of IoT to indoor environment is very weak. Therefore, it is necessary to develop a system for analyzing air pollutants or indoor air quality through real-time monitoring using the IoT. This paper implements a system that measures indoor environmental values using Arduino and various sensors, and stores the information obtained from various sensors into a database of server. The information stored in the server was built as a database and utilized in the ventilation system or air cleaner installed in the home or company's room. In the proposed system, it is possible to check the immediate indoor environmental condition through the LED status display of the monitoring sensor module while reducing the cost of the sensor used to implement IoT technology.

Structure optimization and characterization of a microbolometer for a CO2 detector (이산화탄소 감지소자를 위한 마이크로볼로미터 구조 최적화 및 특성연구)

  • Seo, Ho-Won;Kim, Tae-Geun;Moon, Sung
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.75-80
    • /
    • 2008
  • In this work, we optimized a microbolometer for application of a $CO_2$ detector by using MEMS technology. We fabricated a stable thermal isolation structure by varying the lengths of supporting legs which affect bolometer performance. We could fabricate more stable thermal isolation structure for the microbolometer through the results of ANSYS simulations, and minimize the fabrication processes by using bulk micromachining to use a $CO_2$ detector. The microbolometer shows a detectivity of $2.5{\times}109$ cmHz$^{1/2}$/W at a chopper frequency of 8 Hz and a bias current of $6.25\;{\mu}A$ with a vacuum package of about $3.0{\times}10.3$ torr. Therefore, we put to conclusion that the microbolometer optimized in this experiment could be useful for the application of a $CO_2$ detector.