• Title/Summary/Keyword: 이산화탄소 누출

Search Result 36, Processing Time 0.033 seconds

Technical Review on Risk Assessment Methodology for Carbon Marine Geological Storage Systems (이산화탄소 해양 지중저장 시스템에서의 누출 위해성 평가방법에 관한 기술적 검토)

  • Hwang, Jin-Hwan;Kang, Seong-Gil;Park, Young-Gyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.2
    • /
    • pp.121-125
    • /
    • 2010
  • Carbon Capture and Storage (CCS) technology mitigates the emission amount of carbon dioxide into the atmosphere and can reduce green house effect which causes the climate change. Deep saline aquifer or obsolete oil/gas storage etc. in the marine geological structure are considered as the candidates for the storage. The injection and storage relating technology have been interested in the global society, however the adverse effect caused by leakage from the system failure. Even the safety level of the CCS is very high and there is almost no possibility to leak but, still the risk to marine ecosystem of the high concentrated carbon dioxide exposure is not verified. The present study introduces the system and environmental risk assessment methods. The feature, event and process approach can be a good starting point and we found the some possibility from the fault tree analysis for evaluation. From the FEP analysis, we drove the possible scenario which we need to concentrate on the construction and operation stages.

The Effect of Carbon Dioxide Leaked from Geological Storage Site on Soil Fertility: A Study on Artificial Leakage (지중 저장지로부터 누출된 이산화탄소가 토양 비옥도에 미치는 영향: 인위 누출 연구)

  • Baek, Seung Han;Lee, Sang-Woo;Lee, Woo-Chun;Yun, Seong-Taek;Kim, Soon-Oh
    • Economic and Environmental Geology
    • /
    • v.54 no.4
    • /
    • pp.409-425
    • /
    • 2021
  • Carbon dioxide has been known to be a typical greenhouse gas causing global warming, and a number of efforts have been proposed to reduce its concentration in the atmosphere. Among them, carbon dioxide capture and storage (CCS) has been taken into great account to accomplish the target reduction of carbon dioxide. In order to commercialize the CCS, its safety should be secured. In particular, if the stored carbon dioxide is leaked in the arable land, serious problems could come up in terms of crop growth. This study was conducted to investigate the effect of carbon dioxide leaked from storage sites on soil fertility. The leakage of carbon dioxide was simulated using the facility of its artificial injection into soils in the laboratory. Several soil chemical properties, such as pH, cation exchange capacity, electrical conductivity, the concentrations of exchangeable cations, nitrogen (N) (total-N, nitrate-N, and ammonia-N), phosphorus (P) (total-P and available-P), sulfur (S) (total-S and available-S), available-boron (B), and the contents of soil organic matter, were monitored as indicators of soil fertility during the period of artificial injection of carbon dioxide. Two kinds of soils, such as non-cultivated and cultivated soils, were compared in the artificial injection tests, and the latter included maize- and soybean-cultivated soils. The non-cultivated soil (NCS) was sandy soil of 42.6% porosity, the maize-cultivated soil (MCS) and soybean-cultivated soil (SCS) were loamy sand having 46.8% and 48.0% of porosities, respectively. The artificial injection facility had six columns: one was for the control without carbon dioxide injection, and the other five columns were used for the injections tests. Total injection periods for NCS and MCS/SCS were 60 and 70 days, respectively, and artificial rainfall events were simulated using one pore volume after the 12-day injection for the NCS and the 14-day injection for the MCS/SCS. After each rainfall event, the soil fertility indicators were measured for soil and leachate solution, and they were compared before and after the injection of carbon dioxide. The results indicate that the residual concentrations of exchangeable cations, total-N, total-P, the content of soil organic matter, and electrical conductivity were not likely to be affected by the injection of carbon dioxide. However, the residual concentrations of nitrate-N, ammonia-N, available-P, available-S, and available-B tended to decrease after the carbon dioxide injection, indicating that soil fertility might be reduced. Meanwhile, soil pH did not seem to be influenced due to the buffering capacity of soils, but it is speculated that a long-term leakage of carbon dioxide might bring about soil acidification.

자동차용 냉매가 환경에 미치는 영향

  • 김영일
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.29 no.9
    • /
    • pp.75-78
    • /
    • 2000
  • 환경친화적 자동차에 대한 관심이 커질수록 여러 분야에서 시스템 설계의 영향을 더욱 더 잘 이해하려는 노력이 진행되고 있다. 자동차용 냉방기의 경우 냉방시스템의 세밀한 분석과 환경에 미치는 영향을 최소화하기 위한 설계가 이루어지고 있다. 그 중에서도 냉매의 선택과 그 냉매의 환경적 영향에 대한 자세한 연구가 필요하다. 몬트리올 조약 이후 자동차 산업계는 대부분 R-134a를 채택하고 있는데 이는 R-134a가 오존층을 파괴하지 않을 뿐 아니라 적절한 사이클 효율을 가지면서 안전하고 비독성이며 불연성이기 때문이었다. 최근 지구온난화와 이산화탄소($CO_2$)의 발생원에 대한 관심은 산업계가 사용냉매를 재검토하게 하는 계기가 되었으며, R-134a도 교토 조약의 규제냉매에 속해 있어 자동차용 냉방기의 대체냉매에 대한 연구가 시급하다고 여겨지고 있다. R-134a와 관련된 주된 논점은 냉매 누설시의 영향이다. R-134a의 지구온난화지수(GWP)는 1,300인데, 이는 누출되었을 때 1,300배의 이산화탄소가 누출된 것과 동일하다는 것을 의미하다. 최근 자연냉매의 선호와 맞물려 냉매로서 이산화탄소의 평가에 많은 관심이 모아지고 있다. 본 글에서 자동차용 냉방기의 대체냉매로서 이산화탄소의 상대적인 장점과 R-134a와의 비교에 대해 수행된 연구결과를 나타내었다.

  • PDF

Application of Cyber Physical System (CPS) for Risk Management of a CO2 Storage Site (이산화탄소 저장부지 위해성 관리를 위한 가상물리시스템 적용성 평가)

  • Jeong, Jina;Park, Eungyu;Jun, Seong-Chun;Kim, Hyun-Jun;Yun, Seong-Taek
    • Economic and Environmental Geology
    • /
    • v.50 no.5
    • /
    • pp.363-373
    • /
    • 2017
  • In the present study, adaptability of cyber-physical system (CPS) for risk management of $CO_2$ storage site is examined and the subagging regression (SBR) method is proposed as a key component of the cyber-twin to estimate the risk due to potential $CO_2$ leakage. For these purposes, $CO_2$ concentration data monitored from a controlled $CO_2$ release field experiment is employed to validate the potentialities of the SBR method. From the validation study, it is found that the SBR method has robust estimation capability by showing minimal influence from anomalous measurements, and makes stable and sound predictions for the forthcoming $CO_2$ concentration trend. In addition, the method is found to be well suited as a tool of operational risk assessment based on real-time monitoring data due to the computational efficiency. The overall results suggest that the SBR method has potential to be an important component comprising the cyber twin of CPS for risk management of $CO_2$ storage site.

Effects of Artificial CO2 Release in Soil on Chlorophyll Content and Growth of Pinus densiflora and Quercus variabilis Seedlings (토양 내 인위적인 이산화탄소 누출에 따른 소나무와 굴참나무 묘목의 엽록소 함량과 생장 반응)

  • Kim, Hyun-Jun;Han, Seung Hyun;Kim, Seongjun;Chang, Hanna;Son, Yowhan
    • Journal of Korean Society of Forest Science
    • /
    • v.107 no.4
    • /
    • pp.351-360
    • /
    • 2018
  • This study was conducted to analyze the responses of chlorophyll contents and growth of Pinus densiflora and Quercus variabilis seedlings on distance from the well and $CO_2$ flux after the artificial $CO_2$ release. From June 1 to 30, 2016, $CO_2$ gas was injected at the rate of $6L\;min^{-1}$ at the study site in Eumseong. Chlorophyll content was analyzed in the middle of July, 2016, and root collar diameter (RCD), height (H), and biomass were measured in May and December, 2016 after planting 2-year-old P. densiflora and 1-year-old Q. variabilis seedlings in May, 2015. The chlorophyll content of P. densiflora seedlings did not show a significant correlation with $CO_2$ flux, whereas the chlorophyll content of Q. variabilis seedlings showed a significant negative correlation with increasing $CO_2$ flux (P<0.05). The RCD and H growth rates of both species showed the significant difference in the distance from the well of the $CO_2$ anthropogenic release treatment. In particular, the RCD and H growth rate of P. densiflora seedlings and the RCD growth rate of Q. variabilis seedlings increased significantly as the seedlings were closer to the well, but the H growth rate of Q. variabilis seedlings decreased significantly. In addition, as the $CO_2$ concentration in the ground increases, ${\Delta}R/S$ ratio increases in both species, suggesting that the high $CO_2$ concentration in the soil promotes carbon distribution relative to the root part. The results of this study can be used as data necessary to monitor the $CO_2$ leakage and physiological and growth responses of both species to leakage of stored $CO_2$ in the future.

Detection of Potential Flow Paths of Leaked CO2 from Underground Storage Using Electrical Resistivity Survey (전기비저항탐사 방법에 의한 지중 저장 이산화탄소 누출 가능 경로 탐지)

  • Lim, Woo-Ri;Hamm, Se-Yeong;Hwang, Hak-Soo;Kim, Sung-Wook;Jeon, Hang-Tak
    • The Journal of Engineering Geology
    • /
    • v.28 no.1
    • /
    • pp.69-79
    • /
    • 2018
  • The Korean government attempts to reduce $CO_2$ emissions by 37% to 314.7 Mt $CO_2$, down from the estimated 850.6 Mt $CO_2$ until 2030 in order to confront green house effect. In this context, in 2014, Korean government launched $CO_2$ Storage Environmental Management Research (K-COSEM) Center for carrying out pilot-scale research on $CO_2$ leakage from underground $CO_2$ storage facilities. For the detection of $CO_2$ leakage, it is necessary to identify hydrologeological and geophysical characteristics of the subject area. In the study site of Naesan-ri, Daeso-myeon, Eumseong-gun, Chungbuk Province, two times injection tests (June 28-July 24, 2017 and August 07-September 11, 2017) of $CO_2$ and $SF_6$ dissolved waters, respectively, was conducted to understand the leakage behavior of $CO_2$ from underground. The injection well was drilled to a depth of 24 m with a 21-m casing and screen interval of 21~24 m depth. Two times resistivity surveys on August 18, 2017 and September 1, 2017, were conducted for revealing the flow of the injected water as well as the electrical properties of the study site. The study results have shown that the high-resistivity zone and the low-resistivity zone are clearly contrasted with each other and the flow direction of the injected water is similar to natural groundwater flow. Besides, the low resistivity zone is widely formed from the depth of injection to the shallow topsoil, indicating that the weathered zone of high permeability has high $CO_2$ leakage potential.

Serum Leakage Control using PP/PDMS Composite Membrane (PP/PDMS 복합막을 이용한 혈청누출 제어)

  • 김기범;이삼철;정순량;정경락
    • Membrane Journal
    • /
    • v.10 no.1
    • /
    • pp.47-53
    • /
    • 2000
  • The artificial lung is a device used to replace the function of the lungs. The major function of the lung is to remove carbon dioxide from the venous blood and replace it with oxygen, or arterialize the blood. And the function of the artificial lung is to provide an adequate amount of oxygenated blood to all the tissues of body during the open heart surgery. Extracorporeal life support(ECLS or ECMO) is standard treatment for severe respiratory failure but poses many contributions to future lung transplantation. Artificial Lung or membrane oxygenators available today, based on microporous polypropylene fibers, are associated with two major problems. They require systemic anticoagulation of the patient and they allow serum leakage across the membrane from the blood side to the gas side during long-term use. We obtained newly fabricated polypropylene(PP)/polydimethylsiloxane(PDMS) membranes which combined PP membrane, a microporous support layer with PDMS, and we had investiaged a technique for minimizing serum lekage of polypropylene(PP) membrane. The gas permeability of each PP/PDMS membrane was almost constant before and after the whole blood test by Lee-White method, while that of PP membrane was significantly reduced. Therefore the PP/PDMS membrane could be prevented serum leakage of PP membrane. In addition, the gas permeability of $CO_2$ in PP/PDMS membrane was 11.5 times higher as compared with that of $O_2$.

  • PDF

Spatio-Temporal Monitoring of Soil CO2 Fluxes and Concentrations after Artificial CO2 Release (인위적 CO2 누출에 따른 토양 CO2 플럭스와 농도의 시공간적 모니터링)

  • Kim, Hyun-Jun;Han, Seung Hyun;Kim, Seongjun;Yun, Hyeon Min;Jun, Seong-Chun;Son, Yowhan
    • Journal of Environmental Impact Assessment
    • /
    • v.26 no.2
    • /
    • pp.93-104
    • /
    • 2017
  • CCS (Carbon Capture and Storage) is a technical process to capture $CO_2$ from industrial and energy-based sources, to transfer and sequestrate impressed $CO_2$ in geological formations, oceans, or mineral carbonates. However, potential $CO_2$ leakage exists and causes environmental problems. Thus, this study was conducted to analyze the spatial and temporal variations of $CO_2$ fluxes and concentrations after artificial $CO_2$ release. The Environmental Impact Evaluation Test Facility (EIT) was built in Eumseong, Korea in 2015. Approximately 34kg $CO_2$ /day/zone were injected at Zones 2, 3, and 4 among the total of 5 zones from October 26 to 30, 2015. $CO_2$ fluxes were measured every 30 minutes at the surface at 0m, 1.5m, 2.5m, and 10m from the $CO_2$ releasing well using LI-8100A until November 13, 2015, and $CO_2$ concentrations were measured once a day at 15cm, 30cm, and 60cm depths at every 0m, 1.5m, 2.5m, 5m, and 10m from the well using GA5000 until November 28, 2015. $CO_2$ flux at 0m from the well started increasing on the fifth day after $CO_2$ release started, and continued to increase until November 13 even though the artificial $CO_2$ release stopped. $CO_2$ fluxes measured at 2.5m, 5.0m, and 10m from the well were not significantly different with each other. On the other hand, soil $CO_2$ concentration was shown as 38.4% at 60cm depth at 0m from the well in Zone 3 on the next day after $CO_2$ release started. Soil $CO_2$ was horizontally spreaded overtime, and detected up to 5m away from the well in all zones until $CO_2$ release stopped. Also, soil $CO_2$ concentrations at 30cm and 60cm depths at 0m from the well were measured similarly as $50.6{\pm}25.4%$ and $55.3{\pm}25.6%$, respectively, followed by 30cm depth ($31.3{\pm}17.2%$) which was significantly lower than those measured at the other depths on the final day of $CO_2$ release period. Soil $CO_2$ concentrations at all depths in all zones were gradually decreased for about 1 month after $CO_2$ release stopped, but still higher than those of the first day after $CO_2$ release stared. In conclusion, the closer the distance from the well and the deeper the depth, the higher $CO_2$ fluxes and concentrations occurred. Also, long-term monitoring should be required because the leaked $CO_2$ gas can remains in the soil for a long time even if the leakage stopped.

A Numerical Study on the CO2 Leakage Through the Fault During Offshore Carbon Sequestration (해양지중에 저장된 이산화탄소의 단층을 통한 누출 위험 평가에 관한 수치해석 연구)

  • Kang, Kwangu;Huh, Cheol;Kang, Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.2
    • /
    • pp.94-101
    • /
    • 2015
  • To mitigate the greenhouse gas emission, many carbon capture and storage projects are underway all over the world. In Korea, many studies focus on the storage of $CO_2$ in the offshore sediment. Assurance of safety is one of the most important issues in the geological storage of $CO_2$. Especially, the assessment of possibility of leakage and amount of leaked $CO_2$ is very crucial to analyze the safety of marine geological storage of $CO_2$. In this study, the leakage of injected $CO_2$ through fault was numerically studied. TOUGH2-MP ECO2N was used to simulate the subsurface behavior of injected $CO_2$. The storage site was 150 m thick saline aquifer located 825 m under the continental shelf. It was assumed that $CO_2$ leak was happened through the fault located 1,000 m away from the injection well. The injected $CO_2$ could migrate through the aquifer by both pressure difference driven by injection and buoyancy force. The enough pressure differences made it possible the $CO_2$ to migrate to the bottom of the fault. The $CO_2$ could be leaked to seabed through the fault due to the buoyancy force. Prior to leakage of the injected $CO_2$, the formation water leaked to seabed. When $CO_2$ reached the seabed, leakage of formation water stopped but the same amount of sea water starts to flow into the underground as the amount of leaked $CO_2$. To analyze the effect of injection rate on the leakage behavior, the injection rate of $CO_2$ was varied as 0.5, 0.75, and $1MtCO_2/year$. The starting times of leakage at 1, 0.75 and $0.5MtCO_2/year$ injection rates are 11.3, 15.6 and 23.2 years after the injection, respectively. The leakage of $CO_2$ to the seabed continued for a period time after the end of $CO_2$ injection. The ratios of total leaked $CO_2$ to total injected $CO_2$ at 1, 0.75 and $0.5MtCO_2/year$ injection rates are 19.5%, 11.5% and 2.8%, respectively.

Scheme on Environmental Risk Assessment and Management for Carbon Dioxide Sequestration in Sub-seabed Geological Structures in Korea (이산화탄소 해양 지중저장사업의 환경위해성평가관리 방안)

  • Choi, Tae-Seob;Lee, Jung-Suk;Lee, Kyu-Tae;Park, Young-Gyu;Hwang, Jin-Hwan;Kang, Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.4
    • /
    • pp.307-319
    • /
    • 2009
  • Carbon dioxide capture and storage (CCS) technology has been regarded as one of the most possible and practical option to reduce the emission of carbon dioxide ($CO_2$) and consequently to mitigate the climate change. Korean government also have started a 10-year R&D project on $CO_2$ storage in sea-bed geological structure including gas field and deep saline aquifer since 2005. Various relevant researches are carried out to cover the initial survey of suitable geological structure storage site, monitoring of the stored $CO_2$ behavior, basic design of $CO_2$ transport and storage process and the risk assessment and management related to $CO_2$ leakage from engineered and geological processes. Leakage of $CO_2$ to the marine environment can change the chemistry of seawater including the pH and carbonate composition and also influence adversely on the diverse living organisms in ecosystems. Recently, IMO (International Maritime Organization) have developed the risk assessment and management framework for the $CO_2$ sequestration in sub-seabed geological structures (CS-SSGS) and considered the sequestration as a waste management option to mitigate greenhouse gas emissions. This framework for CS-SSGS aims to provide generic guidance to the Contracting Parties to the London Convention and Protocol, in order to characterize the risks to the marine environment from CS-SSGS on a site-specific basis and also to collect the necessary information to develop a management strategy to address uncertainties and any residual risks. The environmental risk assessment (ERA) plan for $CO_2$ storage work should include site selection and characterization, exposure assessment with probable leak scenario, risk assessment from direct and in-direct impact to the living organisms and risk management strategy. Domestic trial of the $CO_2$ capture and sequestration in to the marine geologic formation also should be accomplished through risk management with specified ERA approaches based on the IMO framework. The risk assessment procedure for $CO_2$ marine storage should contain the following components; 1) prediction of leakage probabilities with the reliable leakage scenarios from both engineered and geological part, 2) understanding on physio-chemical fate of $CO_2$ in marine environment especially for the candidate sites, 3) exposure assessment methods for various receptors in marine environments, 4) database production on the toxic effect of $CO_2$ to the ecologically and economically important species, and finally 5) development of surveillance procedures on the environmental changes with adequate monitoring techniques.

  • PDF