• Title/Summary/Keyword: 이동도

Search Result 50,678, Processing Time 0.082 seconds

Distortion of the Dose Profile in a Three-dimensional Moving Phantom to Simulate Tumor Motion during Image-guided Radiosurgery (방사선수술에서 종양 움직임을 재현시킨 움직이는 팬텀을 이용하여 선량 분포의 왜곡에 대한 연구)

  • Kim, Mi-Sook;Ha, Seong-Hwan;Lee, Dong-Han;Ji, Young-Hoon;Yoo, Seong-Yul;Cho, Chul-Koo;Yang, Kwang-Mo;Yoo, Hyung-Jun;Seo, Young-Seok;Park, Chan-Il;Kim, Il-Han;Ye, Seong-Jun;Park, Jae-Hong;Kim, Kum-Bae
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.268-277
    • /
    • 2007
  • Purpose: Respiratory motion is a considerable inhibiting factor for precise treatment with stereotactic radiosurgery using the CyberKnife (CK). In this study, we developed a moving phantom to simulate three-dimensional breathing movement and investigated the distortion of dose profiles between the use of a moving phantom and a static phantom. Materials and Methods: The phantom consisted of four pieces of polyethylene; two sheets of Gafchromic film were inserted for dosimetry. Treatment was planned to deliver 30 Gy to virtual tumors of 20, 30, 40, and 50 mm diameters using 104 beams and a single center mode. A specially designed robot produced three-dimensional motion in the right-left, anterior-posterior, and craniocaudal directions of 5, 10 and 20 mm, respectively. Using the optical density of the films as a function of dose, the dose profiles of both static and moving phantoms were measured. Results: The prescribed isodose to cover the virtual tumors on the static phantom were 80% for 20 mm, 84% for 30 mm, 83% for 40 mm and 80% for 50 mm tumors. However, to compensate for the respiratory motion, the minimum isodose levels to cover the moving target were 70% for the $30{\sim}50$ mm diameter tumors and 60% for a 20 mm tumor. For the 20 mm tumor, the gaps between the isodose curves for the static and moving phantoms were 3.2, 3.3, 3.5 and 1.1 mm for the cranial, caudal, right, and left direction, respectively. In the case of the 30 mm tumor, the gaps were 3.9, 4.2, 2.8, 0 mm, respectively. In the case of the 40 mm tumor, the gaps were 4.0, 4.8, 1.1, and 0 mm, respectively. In the case of the 50 mm diameter tumor, the gaps were 3.9, 3.9, 0 and 0 mm, respectively. Conclusion: For a tumor of a 20 mm diameter, the 80% isodose curve can be planned to cover the tumor; a 60% isodose curve will have to be chosen due to the tumor motion. The gap between these 80% and 60% curves is 5 mm. In tumors with diameters of 30, 40 and 50 mm, the whole tumor will be covered if an isodose curve of about 70% is selected, equivalent of placing a respiratory margin of below 5 mm. It was confirmed that during CK treatment for a moving tumor, the range of distortion produced by motion was less than the range of motion itself.

A Study on BRCA1/2 Mutations, Hormone Status and HER-2 Status in Korean Women with Early-onset Breast Cancer (젊은 한국인 유방암 환자에서 BRCA1/2 돌연변이와 호르몬 수용체, HER-2 상태에 관한 연구)

  • Choi, Doo-Ho;Jin, So-Young;Lee, Dong-Wha;Kim, Eun-Seog;Kim, Yong-Ho
    • Radiation Oncology Journal
    • /
    • v.26 no.1
    • /
    • pp.65-73
    • /
    • 2008
  • Purpose: Women with breast cancer diagnosed at an age of 40 years or younger have a greater prevalence of germline BRCA1 and BRCA2 mutations than the prevalence of women with breast cancer diagnosed at older ages. Several immunohistochemical characteristics have been identified in breast cancers from studies of Caucasian women with BRCA1/2 mutations having familial or early-onset breast cancers. The aim of this study is to determine whether early-onset breast cancer in BRCA1 or BRCA2 mutation carriers, who were not selected from a family history, could be distinguished by the use of immunohistochemical methods and could be distinguished from breast cancer in women of a similar age without a germline BRCA1 or BRCA2 mutation. We also analyzed the prognostic difference between BRCA1/2 related and BRCA1/2 non-related patients by the use of univariate and multivariate analysis. Materials and Methods: Breast cancer tissue specimens from Korean women with early-onset breast cancers were studied using a tumor tissue microarray. Immunohistochemical staining of estrogen receptor(ER), progesterone receptor(PR) and HER-2, as well as the histology and grade of these specimens, were compared. The prognostic impact of immunohistochemical and histological factors as well as the BRCA1/2 mutation status was investigated separately. Results: There were 14 cases and 16 deleterious BRCA1/2 mutations among 101 patients tested. A family history(4/14) and bilateral breast cancers(3/9) were high risk factors for BRCA1/2 mutations. BRCA1/2-associated cancers demonstrated more expression of ER-negative(19.4% versus 5.1%, p=0.038) and HER-2 negative than BRCA1/2 negative tumors, especially for tumors with BRCA1 tumors The BRCA1/2 mutation rate for patients with triple negative tumors(negative expression of ER, PR and HER-2) was 24.2%. Tumor size, nodal status, and HER-2 expression status were significantly associated with disease free survival, as determined by univariate and multivariate analysis, but the BRCA1/2 status was not a prognostic factor. Conclusion: Breast cancer that occurs in women with a germline BRCA1 or BRCA2 mutations have recognizable immunohistochemical features, which may be useful in identifying individuals that are more likely to carry germline mutations. Although the BRCA1/2 mutation status was not a prognostic factor in Korean women with early-onset breast cancer, more cases with a longer follow-up period are needed for further study.

Development of Dual Reporter System of Mutant Dopamine 2 Receptor ($D_2R$) and Sodium Iodide Symporter (NIS) Transgenes (변이 도파민 2 수용체와 나트륨 옥소 공동 수송체 이입유전자의 이중 리포터시스템 개발)

  • Hwang, Do-Won;Lee, Dong-Soo;Kang, Joo-Hyun;Chang, Young-Soo;Kim, Yun-Hui;Jeong, Jae-Min;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.294-299
    • /
    • 2004
  • Purpose: Both human NIS and mutant $D_2R$ transgenes are proposed as reporting system in transplanted cell tracking. Using hepatoma cell lines, we constructed a dual reporter system containing human sodium-iodide symporter (hNIS) and dopamine 2 receptor ($D_2R$) and compared its characteristics. Materials and Methods: The recombinant plasmid ($pIRES-hNIS/D_2R$) was constructed with IRES (internal ribosome entry site) under control of the CMV promoter $pIRES-hNIS/D_2R$ was transfected to human hepatoma SK-Hep1 cell line with lipofectamine. HEP-ND ($SK-Hep1-hNIS/D_2R$) cells stably expressing hNIS and $D_2R$ was established by selection with G418 for two weeks. RT-PCR was performed to investigate the expression of both hNIS and $D_2R$ genes. The expressions of hNIS and $D_2R$ were measured by $^{125}I$ uptake assays and receptor binding assays. Specific binding of $D_2R$ to $[^3H]spiperone$ was verified by Scatchard plot with (+) butaclamol as a specific inhibitor. $K_d\;and\;B_{max}$ values were estimated. The correlation between hNIS and $D_2R$ expression was compared by using each clone. Results: Similar quantities of hNIS and $D_2R$ genes were expressed on HEP-ND as RT-PCR assays. HEP-ND cells showed 30 to 40 fold higher radioiodine uptakes than those of parental SK-Hep1 cells. $^{125}I$ uptake in HEP-ND cells was completely inhibited by $KClO_4$, a NIS inhibitor Specific binding to HEP-ND cells was saturable and the $K_d\;and\;B_{max}$ values for HEP-ND cells were 2.92 nM, 745.25 fmol/mg protein and 2.91nM, 1323 fmole/mg protein in two clones, respectively. The radioiodine uptake by hNIS activity and $D_2R$ binding was highly correlated. Conclusion: We developed a dual positron and gamma imaging reporter system of hNIS and $D_2R$ in a stably transfected cell line. We expect that $D_2R$ and hNIS genes can complement mutually as a nuclear reporting system or that $D_2R$ can be used as reporter gene when hNIS gene were used as a treatment gene.

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

Studies on the Organo-mercury Residues in Rice Grain -I. Mercury residues in rice seeds treated with organo-mercury fungicide- (수도(水稻)에 처리(處理)된 유기수은제(有機水銀劑)의 잔류성(殘留性)에 관(關)한 연구(硏究) -제1보(第1報) 침지용유기수은제(浸漬用有機水銀劑)로 처리(處理)된 수도종자중(水稻種子中)의 수은잔류량(水銀殘留量)에 관(關)하여-)

  • Lee, Dong-Suk
    • Applied Biological Chemistry
    • /
    • v.8
    • /
    • pp.87-93
    • /
    • 1967
  • 1) For the micro-analysis of mercury in plant materials, the method of Furutani was shown to be the simplest and most efficient way and the recovery of the assay was about 98%. 2) When the rice grain was soaked in 1/1000 diluted solution of organo-mercury fungicide for 8 hours at the end of March, the amounts of mercury residues in the brown rice and unhulled rice were 8.8 to $9.5\;{\mu}g/g$ seeds and 10.1 to $10.7\;{\mu}g/g$ seeds, respectively. 3) By washing the treated rice seeds with running water for three days, tile residual mercury concentration was reduced to 1/4 to 1/5; thus the mercury residues were 1.86 to $1.92\;{\mu}g/g$ for brown rice and 1.96 to $2.93\;{\mu}g/g$ for unhulled rice. 4) The residual mercury was present more in the unhulled rice than in the brown rice, either before or after washing of the treated seeds. 5) Among the different rice varieties, no difference was observed in mercury residues by seed treatment and washing.

  • PDF

Review of 2015 Major Medical Decisions (2015년 주요 의료판결 분석)

  • Yoo, Hyun Jung;Lee, Dong Pil;Lee, Jung Sun;Jeong, Hye Seung;Park, Tae Shin
    • The Korean Society of Law and Medicine
    • /
    • v.17 no.1
    • /
    • pp.299-346
    • /
    • 2016
  • There were also various decisions made in medical area in 2015. In the case that an inmate in a sanatorium was injured due to the reason which can be attributable to the sanatorium and the social welfare foundation that operates the sanatorium request treatment of the patient, the court set the standard of fixation of a party in medical contract. In the case that the family of the patient who was declared brain dead required withdrawal of meaningless life sustaining treatment but the hospital rejected and continued the treatment, the court made a decision regarding chargeable fee for such treatment. When it comes to the eye brightening operation which received measure of suspension from the Ministry of Health and Welfare for the first time in February, 2011, because of uncertainty of its safety, the court did not accept the illegality of such operation itself, however, ordered compensation of the whole damage based on the violation of liability for explanation, which is the omission of explanation about the fact that the cost-effectiveness is not sure as it is still in clinical test stage. There were numerous cases that courts actively acknowledged malpractices; in the cases of paresis syndrome after back surgery, quite a few malpractices during the surgery were acknowledged by the court and in the case of nosocomial infection, hospital's negligence to cause such nosocomial infection was acknowledged by the court. There was a decision which acknowledged malpractice by distinguishing the duty of installation of emergency equipment according to the Emergency Medical Service Act and duty of emergency measure in emergency situations, and a decision which acknowledged negligence of a hospital if the hospital did not take appropriate measures, although it was a very rare disease. In connection with the scope of compensation for damage, there were decisions which comply with substantive truth such as; a court applied different labor ability loss rate as the labor ability loss rate decreased after result of reappraisal of physical ability in appeal compared to the one in the first trial, and a court acknowledged lower labor ability loss rate than the result of appraisal of physical ability considering the condition of a patient, etc. In the event of any damage caused by malpractice, in regard to whether there is a limitation on liability in fee charge after such medical malpractice, the court rejected the hospital's claim for setoff saying that if the hospital only continued treatments to cure the patient or prevent aggravation of disease, the hospital cannot charge Medical bills to the patient. In regard to the provision of the Medical Law that prohibit medical advertisement which was not reviewed preliminarily and punish the violation of such, a decision of unconstitutionality was made as it is a precensorship by an administrative agency as the deliberative bodies such as Korean Medical Association, etc. cannot be denied to be considered as administrative bodies. When it comes to the issue whether PRP treatment, which is commonly performed clinically, should be considered as legally determined uninsured treatment, the court made it clear that legally determined uninsured treatment should not be decided by theoretical possibility or actual implementation but should be acknowledged its medical safety and effectiveness and included in medical care or legally determined uninsured treatment. Moreover, court acknowledged the illegality of investigation method or process in the administrative litigation regarding evaluation of suitability of sanatorium, however, denied the compensation liability or restitution of unjust enrichment of the Health Insurance Review & Assessment Service and the National Health Insurance Corporation as the evaluation agents did not cause such violation intentionally or negligently. We hope there will be more decisions which are closer to substantive truth through clear legal principles in respect of variously arisen issues in the future.

  • PDF

Stress/Rest Tc-99m-MIBI SPECT in Comparison with Rest/Stress Rubidium-82 PET (휴식/부하 심근 Rubidium-82 양전자단층촬영과 부하/휴식 심근 Tc-99m-MIBI 단일광자단층촬영의 비교)

  • Lee, D.S.;Kang, K.W.;Lee, K.H.;Jeong, J.M.;Kwark, C.;Chung, J.K.;Lee, M.C.;Seo, J.D.;Koh, C.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.31-40
    • /
    • 1995
  • We compared stress/rest myocardial Tc-99m-MIBl tomographic image findings with rest/stress rubidium-82 tomographic images. In 23 patients with coronary artery disease (12 of them received bypass grafts before) and 6 normal subjects, rest rubidium PET study was performed : rubidium-82 and Tc-99m-MIBI were injected simultaneously to each patient after dipyridamole stress for rubidium PET and MIBI SPECT; and rest MIBI SPECT was performed 4 hours thereafter. We scored segmental decrease of rubidium or MIBI uptakes into 5 grades for 29 segments from 3 short-axis, vertical and horizontal slices. Scores were summed for each major arterial territory. When more score than two grade-2's or one grade-3 was considered as the cue for significant stenosis for major arterial territories, 67% of 46 stenosed arteries were found with MIBI studies and 78% of them by rubidium studies. Fourteen among 28 grafted arterial territories of 12 post-CABG patients were found normal with both rubidium and MIBI. Segmental scores were concordant between rubidium and MIBI in 72% of 709 stress segments and in 80% of 825 rest segments. Stress rubidium segmental scores were less than stress MIBI scores in 9%, so were rest rubidium scores. Stress rubidium scores were more than stress MIBI scores in 20% of segments, and rest rubidium segmental scores were more than rest MIBl scores in 11%. Rank correlations (Spearman's rho's more than 0.7(stress) and 0.5(rest), slopes (MIBI/rubidium) around 0.7(stress) and 0.9 (rest)) suggested deeper and wider defects in stress with rubidium. Slope over 1 (MIBI/rubidium) with LAD segemental scores at rest and 7 territories which had much larger score with MIBI revealed exaggeration of rest defects with rest MIBI in same-day stress/rest study. Difference scores (stress-rest for each territory) suggesting Ischemia were larger with rubidium (slope of MIBI/rubidium around 0.45). As has been implied by animal or separate-day-human studies, these segmental analyses with simultaneous examination in patients told that rubidium PET flow studies disclose ischemia more often than MIBI studies and that rest MIBI studies in same-day stress/rest-sequence gave a little larger rest defect than they would have shown.

  • PDF

Diagnostic Accuracy of $^{99m}Tc$-DISIDA Scintigraphy in Biliary Atresia (선천성 담도폐쇄증에서 $^{99m}Tc$ DISIDA 신티그라피의 진단정확성)

  • Hyun, In-Young;Lee, Dong-Soo;Lee, Kyung-Han;Kim, Jong-Ho;Chung, June-Key;Suh, Jung-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.357-363
    • /
    • 1994
  • We evaluated the diagnostic accuracy of $^{99m}Tc$-DISIDA scintigrauhy as a mean of differentiating biliary atresia from neonatal hepatitis. $^{99m}Tc$-DISIDA scintigraphy was visually interpreted by assessing the presence or absence of radioactivity in the intestine or gall bladder. In patients without intestinal radioactivity, we measured the hepatic retention index and the hepatic uptake index. The hepatic retention Index was expressed as the amount of change of liver activity from 5 minutes to 30 minutes postinjection. The hepatic uptake Index was graded visually with 5 minute images using the following scoring scheme : grade 0(normal hepatic uptake), grade 1(decreased hepatic uptake), grade 2(hepatic uptake equal to cardiac uptake), and grade 3(hepatic uptake less than cardiac uptake). Age, total bilirubin, and hepatic uptake index were compared between the biliary atresia and the neonatal hepatitis group, between neonatal hepatitis patients with and without intestinal radioactivity, and between the biliary atresia and neonatal hepatitis patients with absent intestinal radioactivity. The results were as follows ; 1) None of the 30 biliary atresia patients showed intestinal radioactivity, while 31/40 neonatal hepatitis patients showed intestinal radioactivity. The sensitivity, specificity, and accuracy of the presence of intestinal radioactivity ?or the diagnosis of biliary atresia was 100%, 78%, and 87%, respectively. 2) In patients with absent intestinal radioactivity the mean hepatic retention index was $1.5{\pm}0.6$ in the 16 biliary atresia patients, and $1.1{\pm}0.2$ in the 7 neonatal hepatitis patients(p<0.01). All 7 patients with hepatic retention index over 1.5 had biliary atresia. But there were 9 patients with biliary atresia below 1.5. 3) No significant differences were found in age, total bilirubin, or hepatic uptake Index between biliary atresia and neonatal hepatitis patients. However there were differences in age, total bilirubin, and hepatic uptake index between neonatal hepatitis patients with and without intestinal radioactivity. The hepatic uptake index was significantly lower, age was old, and total bilirubin was low in the group with intestinal radioactivity compared the group without intestinal radioactivity(p<0.05). Relation between total bilirubin and the hepatic uptake index was that total bilirubin was relatively low at normal hepatic uptake index in biliary atresia and neonatal hepatitis patients. 4) When hepatic uptake index and hepatic retention index were high it suggest that biliary atresia is more likely, considered relation between hepatic uptake Index and the hepatic retention index. Thus, we conclude that $^{99m}Tc$-DISIDA scintigraphy is accurate in the differential diagnosis of biliary atresia and neonatal hepatitis. In patients without intestinal radioactivity, the hepatic retention index and hepatic uptake index, along with the patient's age and total bilirubin level may supplement diagnosis and improve diagnostic accuracy.

  • PDF

Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay (핵의학 체외 검사에서 자동분주기를 이용한 Random Assay 가능성평가)

  • Moon, Seung-Hwan;Lee, Ho-Young;Shin, Sun-Young;Min, Gyeong-Sun;Lee, Hyun-Joo;Jang, Su-Jin;Kang, Ji-Yeon;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.323-329
    • /
    • 2009
  • Purpose: Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. Materials and Methods: The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. Results: The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2$\pm$1.7%, 3.9$\pm$2.1%, 7.1$\pm$6.2%, 11.2$\pm$7.2%. The CVs by random assay were 2.1$\pm$1.7%, 4.8$\pm$3.1%, 3.6$\pm$4.8%, and 7.4$\pm$6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). Conclusion: The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay.

A Consideration of Apron's Shielding in Nuclear Medicine Working Environment (PET검사 작업환경에 있어서 APRON의 방어에 대한 고찰)

  • Lee, Seong-wook;Kim, Seung-hyun;Ji, Bong-geun;Lee, Dong-wook;Kim, Jeong-soo;Kim, Gyeong-mok;Jang, Young-do;Bang, Chan-seok;Baek, Jong-hoon;Lee, In-soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.110-114
    • /
    • 2014
  • Purpose: The advancement in PET/CT test devices has decreased the test time and popularized the test, and PET/CT tests have continuously increased. However, this increases the exposure dose of radiation workers, too. This study aims to measure the radiation shielding rate of $^{18}F-FDG$ with a strong energy and the shielding effect when worker wore an apron during the PET/CT test. Also, this study compared the shielding rate with $^{99m}TC$ to minimize the exposure dose of radiation workers. Materials and Methods: This study targeted 10 patients who visited in this hospital for the PET/CT test for 8 days from May 2nd to 10th 2013, and the $^{18}F-FDG$ distribution room, patient relaxing room (stand by room after $^{18}F-FDG$ injection) and PET/CT test room were chosen as measuring spots. Then, the changes in the dose rate were measured before and after the application of the APRON. For an accurate measurement, the distance from patients or sources was fixed at 1M. Also, the same method applied to $^{99m}TC's$ Source in order to compare the reduction in the dose by the Apron. Results: 1) When there was only L-block in the $^{18}F-FDG$ distribution room, the average dose rate was $0.32{\mu}Sv$, and in the case of L-blockK+ apron, it was $0.23{\mu}Sv$. The differences in the dose and dose rate between the two cases were respectively, $0.09{\mu}Sv$ and 26%. 2) When there was no apron in the relaxing room, the average dose rate was $33.1{\mu}Sv$, and when there was an apron, it was $22.3{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $10.8{\mu}Sv$ and 33%. 3) When there was no APRON in the PET/CT room, the average dose rate was $6.9{\mu}Sv$, and there was an APRON, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $1.4{\mu}Sv$ and 25%. 4) When there was no apron, the average dose rate of $^{99m}TC$ was $23.7{\mu}Sv$, and when there was an apron, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $18.2{\mu}Sv$ and 77%. Conclusion: According to the result of the experiment, $^{99m}TC$ injected into patients showed an average shielding rate of 77%, and $^{18F}FDG$ showed a relatively low shielding rate of 27%. When comparing the sources only, $^{18F}FDG$ showed a shielding rate of 17%, and $^{99m}TC$'s was 77%. Though it had a lower shielding effect than $^{99m}TC$, $^{18}F-FDG$ also had a shielding effect on the apron. Therefore, it is considered that wearing an apron appropriate for high energy like $^{18}F-FDG$ would minimize the exposure dose of radiation workers.

  • PDF