• Title/Summary/Keyword: 의학적 평가

Search Result 1,984, Processing Time 0.024 seconds

Comparison of Ultrasound with $^{99m}-Tc-MIBI$ Scintimammography in the Detection of Breast Cancer (유방암의 진단에서 유방초음파 검사와 $^{99m}-Tc-MIBI$ 유방스캔의 비교)

  • Seok, Ju-Won;Kim, Seong-Jang;Kwak, Hi-Suk;Lee, Jun-Woo;Kim, In-Ju;Kim, Yong-Ki;Bae, Young-Tae;Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.3
    • /
    • pp.177-184
    • /
    • 2002
  • Purpose: Ultrasonography and $^{99m}-Tc-MIBI$ scintimammography were validated as useful diagnostic tools for primary breast cancer. However, ultrasound has the problem of low specificity. We compared the diagnostic usefulness of ultrasound with $^{99m}-Tc-MIBI$ scintimammography in the diagnosis of breast cancer. Materials and Methods: This study included 174 patients who had ultrasound and $^{99m}-Tc-MIBI$ scintimammography peformed on breast masses from 1999 to 2000. The pathologic results were obtained by surgery or FNAB. Results: Among the 174 patients, malignant breast disease numbered 117 and benign breast disease numbered 57. Ultrasound revealed 88 TP, 9 FN, 8 FP, 34 TN, and 35 indeterminate cases. $^{99m}-Tc-MIBI$ scintimammography revealed 91 TP, 25 FN, 9 FP, and 48 TN. The sensitivity, specificity, positive predictive value, and negative predictive value of Ultrasound were 66.7%, 44.2%, 67.2%, and 43.6% respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of $^{99m}-Tc-MIBI$ scintimammography were 77.8%, 84.2%, 91%, and 64.9% respectively. Among the 35 indeterminate ultrasound cases, $^{99m}-Tc-MIBI$ scintimammography revealed 13 TP, 15 TN, and 7 FP Conclusion: $^{99m}-Tc-MIBI$ Scintimammography was more sensitive and specific than ultrasound for the detection of primary breast cancer and provided more useful information in cases of indeterminate ultrasound findings.

Second-Look Arthroscopy after ACL Reconstruction with Autograft Tendons (자가건을 이용한 전방 십자 인대 재건술 후 이차 관절경 검사)

  • Fang, Zhen-Zhu;Yoo, Moon-Jib;Kim, Myung-Ho;Bahng, Seung-Chu;Kim, You-Jin;Park, Hee-Gon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.6 no.1
    • /
    • pp.38-44
    • /
    • 2007
  • Purpose: To evaluate status of reconstructed ACL and changes around graft through second-look arthroscopy after arthroscopic reconstruction of the ACL with autograft tendons. Material and Methods: Between Jun. 2003 and Feb. 2007, the second look arthroscopy was performed on 22 cases. Second-look arthroscopy was conducted on average 15.1 $(7\sim31)$ months after reconstruction. 15 cases received hamstring tendon autograft, 7 cases received bone-patellar tendonbone autograft. We measured graft tension using displacement by probing, synovial coverage by visual analysis at second-look arthroscopy The assay in Lysholm score, Lachmann test and KT-2000 arthrometer were evaluated status of reconstructed ACL. Results: The hamstring tendon group showed normal tension in 11 cases and lax tension in 4 cases. The patellar tendon group showed normal tension in 3 cases, lax tension in 2 cases and partial tear in 2 cases. In the hamstring tendon group, synovial coverage was good in 11 cases, half in 3 cases and pale in 1 case, and the bone-patellar tendon-bone group was good in 4 cases and half in 3 cases. The patellar tendon group was superior to the hamstring tendon group in Lysholm score (p<0.05), but insignificance difference in KT-2000 arthrometer results statistically. Conclusion: The hamstring tendon group was superior to the bone-patellar tendon-bone group in second-look arthroscopy after ACL reconstruction with autograft tendons results, but long term follow up will be necessary to further evaluated.

  • PDF

The Investigation of Current Information Regarding Renal Diseases in Mass Media (대중매체를 통한 신장 관련 정보 제공 실태에 대한 고찰)

  • Lim, Dong-Hee;Jung, Ji-In;Yim, Hyung-Eun;Eun, Baik-Lin;Yoo, Kee-Hwan;Hong, Young-Sook;Lee, Joo-Won
    • Childhood Kidney Diseases
    • /
    • v.12 no.1
    • /
    • pp.47-53
    • /
    • 2008
  • Purpose: We often have patients who acquired incorrect medical information from the mass media. The purpose of this study was to evaluate credibility of articles in newspapers and medical counseling on websites about renal diseases. Methods: Kidney information was searched in 6 newspapers for the past 10 years, and 4 portal websites and 17 internet health counseling sites for the past 5 years. We classified them according to information providers and evaluated credibility by giving points 3, 2, 1 to correct, mostly correct but ambiguous, and incorrect contents, respectively. We compared the credibility of the groups with each other. Results: Sixty four articles from newspapers, and 789 and 506 medical counselings from portal websites and internet health counseling sites were selected, respectively. The kidney information providers in newspapers were medical journalists(doctors)(31.2%), kidney specialists(doctors)(23.4%) and so on. The consultants in the portal sites were doctors(49.1%)and anonymous reporters (49.9%). In internet health counseling sites, 91% of the consultants were doctors. All articles in the newspapers were credible. Doctors' answers were more credible than nonphysicians'(P=0.005) and anonymous contributors(P<0.001) in portal sites. In health counseling sites, doctors answered more reliably than nonphysicians. Conclusion: The kidney information in newspapers was credible. It is important for questioners to confirm the type of consultants in websites. We suggest that doctors, especially kidney specialists need to increase their roles in offering information to mass media.

  • PDF

ROC Analysis of Visual Assessments Made in Gated Blood Pool Scans of Patients with Coronary Artery Disease (관상동맥질환에서 심장풀 스캔의 육안적 평가에 대한 ROC 분석)

  • Lee, Kyun-Han;Choi, Yoon-Ho;Lee, Bum-Woo;Moon, Dae-Hyuk;Koong, Sung-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.175-181
    • /
    • 1989
  • Visual assessment of regional wall motion abnormality (RWMA) by gated blood pol scan (GBPS) serves as an useful parameter in the diagnosis, functional evaluation, and follow up in various clinical settings, but are still subject to some inherent limitations. On important problem may be the interobserver as well as intraobsever variation that may well be present due to the subjective nature of the interpretations. This study was carried out to determine the reliability and reproducibility of visual assessments made in GBPSs, and to observe the degree to which the results would be influenced by observer variation. Fifty two patients with coronary heart disease had resting GBPS and contrast ventriculography within 4 days appall. Contrast ventriculography-showed normal wall motion in 6 patients and the remaining 46 had RWMA in one or more segments. The anterior and left anterolateral views of all 52 GBPSs were analyzed by three independent observers, who selected from 5 scales, their level of confidence that there was RWMA in that segment. Reciever operating characteristic (ROC) curves for each analysis was plotted and the area under the curve $(\theta)$ was used as a parameter representing each observer's performance in his interpretations. The findings of contrast ventriculographies were used as the standard for RWMA. The apical and inferoapical segments showed the best correlation with contrast ventriculography ($\theta=0.90-0.94$, 0.81-0.94, respectively), and the inferior wall showed the poorest correlation $(\theta=0.70-0.74)$. The interpretations of the inferior, septal, apical, and posteroinferior, segments showed no difference between the observers, but there was significantly better performance in assessment by observer A compared to that by B or C for the anterolateral segments ($\theta=0.87$, 0.78, 0.76, respectively. p<0.01 for A vs B, p<0.05 for A vs C), as well as when all segments were considered altogether ($\theta=0.88$, 0.83, 0.82, respectively. both p<0.05). This was also true for the infero-apical segment between A and C ($\theta=0.09$, 0.81, p<0.05). The intraobserver variation, however, did not appear significant, with only the inferior segment for observer B showing any significant difference when observer A and B repeated the analysis 10 days latter. There was no difference in assessing dyskinesia, with all observers showing a high performance ($\theta=0.98$, 0.87, 0.97, respectively). The visual assessment of left ventricular ejection fraction by all three observers correlated well with the calculated value from a semiautomated method (Spearman's r = 0.91, 0.83, 0.83. p<0.01, p<0.05, p < 0.05). The assessment of LV and RV size also correlated well between the three observers (Kendall's w = 0.80, 0.51, p<0.01 for both left and right ventricles). The above findings suggest that RWMA visually assessed by GBPS correlates well with that done by contrast ventriculography. And although the observer's experience or skill may influence the results in certain segments, visual analysis of GBPS may serve as a reliable and reproducible means for evaluating ventricular function.

  • PDF

Predictive Values of Early Rest/24 Hour Delay T1-201 Perfusion SPECT for Wall Motion Improvement in Patients with Acute Myocardial Infarction After Reperfusion (급성 심근 경색 환자에서 재관류 후 조기에 시행한 휴식/24시간 지연 T1-201 심근 SPECT의 심근벽 운동 호전 예측능)

  • Hyun, In-Young;Kwan, June
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.259-265
    • /
    • 1998
  • Purpose: We studied early rest/24 hour delay T1-201 perfusion SPECT for prediction of wall motion improvement after reperfusion in patients with acute myocardial infarction. Materials and Methods: Among 17 patients (male/female= 11/6, age: $59{\pm}13$) with acute myocardial infarction, 15 patients were treated with percutaneous transcoronary angioplasty (direct:2, delay: 11) and intravenous urokinase (2). Spontaneous resolution occurred in infarct-related arteries of 2 patients. We confirmed TIMI 3 flow of infarct-related artery after reperfusion in all patients with coronary angiography. We performed rest T1-201 perfusion SPECT less then 6 hours after reperfusion and delay T1-201 perfusion SPECT next day. T1-201 uptake was visually graded as 4 point score from normal (0) to severe defect (3). Rest T1-201 uptake ${\le}2$ or combination of rest T1-201 uptake ${\le}2$ or late reversibility were considered to be viable. Myocardial wall motion was graded as 5 point score from normal (1) to dyskinesia (5). Myocardial wall motion was considered to be improved when a segment showed an improvement ${\ge} 1$ grade in follow up echo compared with the baseline values. Results: Among 98 segments with wall motion abnormality, the severity of myocardial wall motion decrease was as follow: mild hypokinesia: 18/98 (18%), severe hypokinesia: 28/98 (29%), akinesia: 51/98 (52%), dyskinesia: 1/98 (1%). The wall motion improved in 85%. Redistribution (13%), and reverse redistribution (4%) were observed in 24 hour delay SPECT. Positive predictive value (PPV) and negative predictive value (NPV) of combination of late reversibility and rest T1-201 uptake were 99%, and 54%. PPV and NPV of rest T1-201 uptake were 100% and 52% respectively. Predictive values of combination of rest T1-201 uptake and late reversibility were not significantly different compared with predictive values of rest T1-201 uptake only. Conclusion: We conclude that early T1-201 perfusion SPECT predict myocardial wall motion improvement with excellent positive but relatively low negative predictive values in patients with acute myocardial infarction after reperfusion.

  • PDF

Diagnostic Ability of Tc-99m MIBI SPECT in Coronary Artery Diseases is not Affected by the Degree of Exercise (운동 정도와 무관한 Tc-99m Methoxyisobutyl Isonitrile 심근관류 스캔의 진단능)

  • Lee, Jae-Tae;Kim, Jong-Soo;Chun, Kyung-Ah;Lee, Sang-Woo;Kang, Do-Young;Cho, Yong-Keun;Chae, Shung-Chull;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.40-48
    • /
    • 1999
  • Purpose: The sensitivity of ST-depression in the electrocardiogram during exercise is influenced by the level of efforts. However, unlike the prevalence of ST-depression on exercise ECG, the degree of exercise is reported to do not influence the diagnostic ability of myocardial perfusion scan. Furthermore, the relation between the prevalence of myocardial ischemia and effort is still controversial. We evaluated the effect of the degree of exercise on the ability of SPECT imaging to detect coronary artery stenosis. Materials and Methods: The patient population was comprised of 111 patients (73 men and 38 women, mean age 56 years) who underwent an exercise test in conjunction with Tc-99m MIBI and cardiac catheterization within 3 months apart each other. The degree of exercise was classified into four groups according to the percentage of maximal predicted heart rate. The sensitivity and specificity was compared between each group. Results: The overall diagnostic sensitivity was significantly higher with Tc-99m MIBI SPECT than exercise ECG. The specificity was not significantly different between two tests. Sensitivity and specificity of Tc-99m MIBI was not different between four groups. Sensitivity for individual coronary stenosis seemed to be lower in subjects who had premature termination of exercise due to early appearance of ST depression. Conclusion: These results suggest that the overall diagnostic sensitivity of Tc-99m MIBI myocardial perfusion SPECT is not significantly affected by the degree of exercise in stable patients undergoing symptom-limited treadmill exercise testing. Myocardial perfusion SPECT imaging should be added to routine exercise stress testing for the detection of coronary artery disease.

  • PDF

Detection of HCV-RNA by Reverse Transcription Polymerase Chain Reaction Using Biotinylated and Radioiodinated Primers (역전사 중합효소 연쇄반응(RT-PCR)에 의한 HCV-RNA의 검출 : Biotin 및 방사성옥소 표지 Primer로 구성된 Kit의 이용)

  • Ryu, Jin-Sook;Moon, Dae-Hyuk;Cheon, Jun-Hong;Chung, Yoon-Young;Park, Hung-Dong;Chung, Young-Hwa;Lee, Young-Sang
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.220-226
    • /
    • 1994
  • This study was performed to evaluate the clinical applicability of the reverse transcription polymerase chain reaction (RT-PCR ) kit of HCV-RNA using biotinylated and radioiodinated primers. Study subjects were 118 patients with positive anti-HCV. HCV-RNA in patient's serum was extracted by guanidium thiocyanate method. After first amplification, the product was reamplified by primers labelled with biotin and I-125. The final amplification product was defected by counting the radioactivity after incubation in avidin coated tubes. In 51 samples, the test was repeated for evaluation of reproducibility. This new method was also compared with conventional RT-PCR methods in 34 samples from patients with chronic liver disease. The results were as follows ; 1) HCV-RNA was positive in 85(97%)of 88 patients with chronic liver disease, and in 23 (73%) of 30 patients with normal liver function. 2) In comparison with conventional method, HCV-RNA was detected in 32(94%) of 34 patients with new method, whereas in 27(79%) of the same group with conventional method. 3) Repeated test with new method in 52 samples demonstrated 82% of concordant result. In conclusion, new method with biotinylated and radioiodinated primers was more sensitive than conventional method. However, great care must be taken for quality control because there were considerable interassay variation and possiblity of false positivity and false negativity.

  • PDF

The Usefulness of Tc-99m MIBI SPECT in the Localization and the Assessment of Radiotherapy in Non-Small Cell Lung Cancer (비소세포 폐암의 국소화 및 방사선치료 판정에 있어 Tc-99m MIBI SPECT의 유용성)

  • Bom, Hee-Seung;Song, Ho-Chun;Kim, Ji-Yeul;Nam, Taek-Keum;Ahn, Sung-Ja;Chung, Woong-Ki;Nah, Byung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.186-191
    • /
    • 1994
  • Tc-99m MIBI, a lipophilic cation, was reported as a useful agent for localization of lung cancer. The effect of radiation therapy on the uptake of Tc-99m MIBI in lung cancer, however, was not well evaluated. The aim of the present study was to elucidate the usefulness of Tc-99m MIBI SPECT in the localization and the assessment of radiotherapy in non-small cell lung cancer. Twenty patients(19 males and 1 female, mean age 59, 16 squamous cell ca and 4 adenoca) were studied with Tc-99m MIBI SPECT before radiation therapy. Eleven patients(10 males and 1 female, mean age 59, 8 squamous cell ca and 3 adenoca) were repeated the study 1 month after the completion of radiation therapy(mean dose 6453cGy). All patients showed positive uptakes of Tc-99m MIBI in their tumors. One patient showed a hot uptake in atelectatic area. There was no difference of Tc-99m MIBI uptakes between squamous cell ca and adenoca either on planar or tomographic images. Tc-99m MIBI uptake ratios of squamous cell ca and adenoca were $1.50{\pm}0.16$ and $1.45{\pm}0.15$ on planar images, and $2.73{\pm}0.46$ and $2.54{\pm}0.37$ on tomographic images, respectively. The concordance between radiological change(chest x-ray and CT) and change of Tc-99m MIBI uptakes was 9/11 (81.8% ). In conclusion, Tc-99m MIBI SPECT was useful in the localization of tumor and the assessment of radiation therapy in non-small cell lung cancer.

  • PDF

Measurements of Actual Effective Half-Life in $^{131}I$ Therapy for Graves' Hyperthyroidism (그레이브스 갑상선기능항진증 환자의 방사성옥소($^{131}I$) 치료시 실제 유효반감기의 측정)

  • So, Yong-Seon;Kim, Myung-Seon;Kwon, Ki-Hyun;Kim, Seok-Whan;Kim, Tae-Hyung;Han, Sang-Woong;Kim, Eun-Sil;Kim, Chong-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Radioiodine($^{131}I$) has been used for the treatment of Graves' hyperthyroidism since the late 1940's and is now generally regarded as the treatment of choice for Graves' hyperthyroidism who does not remit following a course of antithyroid drugs. But for the dose given, several different protocols have been described by different centers, each attempting to reduce the incidence of long-term hypothyroidism while maintaining an acceptable rate control of Graves' hyperthyroidism. Our goals were to evaluate effective half-life and predict absorbed dose in Graves' hyperthyroidism patients, therefore, to calculate and readminister radioiodine activity needed to achieve aimed radiation dose. Our data showed that the mean effective $^{131}I$ half-life for Graves' disease is 5.3 days(S.D=0.88) and mean biologic half-life is 21 days, range 9.5-67.2 days. The mean admininistered activity and the mean values of absorbed doses were 532 MBq(S.D.=254), 112 Gy (S.D.=50.9), respectively. The mean activity needed to achieve aimed radiation dose were 51MBq and marked differences of $^{131}I$ thyroidal uptake between tracer and therapy ocurred in our study. We are sure that the dose calculation method that uses 5 days thyroidal $^{131}I$ uptake measurements after tracer and therapy dose, provides sufficient data about the effective half-life and absorbed dose of $^{131}I$ in the thyroid and predict the effectiveness of $^{131}I$ treatment in Graves' hyperthyroidism.

  • PDF

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF