• Title/Summary/Keyword: 의료 정보 교환

Search Result 134, Processing Time 0.026 seconds

Legal Issues for the Implementation of Non-Face-to-Face Treatment (비대면진료 실행을 위한 법적 쟁점)

  • Kwon, Ohtak
    • The Korean Society of Law and Medicine
    • /
    • v.23 no.3
    • /
    • pp.47-87
    • /
    • 2022
  • Due to the COVID-19 pandemic, non-face-to-face treatment was temporarily permitted. A lot of consensus has been formed on the need to continuous non-face-to-face treatment. However, the current 「Medical Service Act」 only permits telemedicine between doctors and medical personnel. On the other hand, as a result of legal interpretation, there is an opinion that non-face-to-face treatment is allowed. But considering the overall legal system, non-face-to-face treatment is not allowed. Nevertheless, we have to consider the reality such as the development of science and technology and the outbreak of infectious diseases. Therefore, it is not advisable to allow face-to-face treatment only. Ultimately, it is necessary to find ways to ensure that non-foce-to-face treatment can be performed in a safe and effective manner. And it should be institutionalized. This is strategically necessary and important. Therefore, we must look over ahead legal issues to be discussed. First of all, the scope, the target disease and the subject of implement have to be clear. Also, structurally, the standards of facilities and equipment must be prepared for non-face-to-face treatment to be implemented. Functionally, communication and information exchange between doctors and patients should be well conducted. In addition, the information protection management system that occurs in the process of non-face-to-face treatment should be materialized. Lastly, the issue of responsibility and cost of non-face-to-face treatment should be decided in detail. When these problems materialize, it can be expected that a safe non-face-to-face treatment environment will be established.

Development of a Version-Compatible HL7 Parser (버전 상호 호환 HL7 파서의 개발)

  • Lee, In Keun;Yoon, Hyo Jeon;Hwang, Dosam
    • Annual Conference on Human and Language Technology
    • /
    • 2018.10a
    • /
    • pp.520-521
    • /
    • 2018
  • 의료정보 교환 국제 표준인 HL7의 처리를 위한 인터페이스 소프트웨어에서 다양한 버전 사이의 호환성 문제의 해결 방법으로 객체 지향적 구조에 기반한 HL7 파서(Parser)의 구조가 설계되었다. 그러나 수천개의 HL7 메시지 및 구성요소를 처리할 수 있는 HL7 파서를 직접 구현하기 위해서 많은 시간과 인력이 필요하다. 또한, 구현된 파서의 기능 변경 시 수천 개의 파일을 프로그래머가 직접 수정하는 방법은 매우 비효율적이다. 따라서 본 연구에서는 버전 상호 호환 가능한 HL7 파서의 설계에 따라 HL7 파서를 효과적인 구현할 수 있는 방법을 제안한다. 제안한 방법에 따라 HL7 파서를 구현하고, HL7 메시지의 버전 간 변환 테스트를 수행하여 개발한 파서의 효용성을 확인한다.

  • PDF

초고속 통신망을 이용한 척추 경나사못 삽입술 Simulator

  • 윤승식;성정환;최희원;김영호;강석호;염진섭
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1999.04a
    • /
    • pp.105-107
    • /
    • 1999
  • 본 연구의 목적은 CT장비로부터 얻어지는 단면 영상을 이용하여 재구성한 3차원 Voxel 정보를 기반으로 의료 시술 중 위험도가 높으며 장기간의 수술 훈련이 필요한 수술인 척추경나사 삽입술에 대한 모의 시술기를 개발하는 것이다. 모의 시술기의 입력은 환자의 환부에 대한 CT와 모의 시술을 해보고자 하는 의사 (사용자)의 입력 (경나사의 진입 위치와 각도)이 되며 출력은 의사들이 시술장에서 받을 수 있는 유일한 방법인 Voxel데이터로부터 재생성된 X-Ray이미지, 혹은 C-Arm의 동영상이며, 최종 결과 출력은 나사못이 삽입된 재구성 CT 이미지들과 3차원 정보를 볼 수 있는 Image Based Rendering의 Image data set이 된다. 본 연구에서는 각 시각화 부분의 특성을 고려하여 direct volume projection, surface modeling, 그리고 최근 많은 관심을 받고 있는 Image Based Rendering 기법을 intergrate하여 사용하였으며 각 시각화 모듈의 초고속 정보 통신망에서의 정보 교환에 대한 방법론에 대해 다루고 있다.

  • PDF

Enhanced latitude for digital projection radiography (디지털 투시촬영의 관용도 향상)

  • Han, Seung-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.98-101
    • /
    • 2002
  • 대조도와 관용도사이의 손실 교환은 투사 방사선 촬영에 있어서 잘 알려져 있고 또한 오랫동안 지속되어온 영상의 질에 있어서의 제약이었다. 전자적인 영상획득의 도입으로 한 영상 내에 넓은 영역의 X-Tay 노출을 포획하는 것이 가능해 졌다. 그러나, 진단에 필요한 세부영역 들을 위해 적절한 대조도를 유지하는 반면, 일반적으로 기대되는 관용도 범위 이외의 정보가 시각화 되어지는 것과 같은 영상의 rendering과 displaying의 문제가 남아 있었다. 이 문서에 묘사되는 EVP(Enhanced Visualization Processing)는 이 문제를 중점적으로 다룬다. 방대한 진단용 CR 영상 데이터베이스로부터 선택된 14개의 검사유형 당 각각 5개의 영상들을 포함한, 총 70개의 영상들을 사용하여 임상 보고서가 제출되었다. 각 영상에 대해, control rendering은 현재 개발되어 있는 automatic tone scaling algorithm(자동 톤 스케일 알고리즘)에 의해 생성되었고, test rendering은 그 control of image에 EVP를 인가함에 의해 생성되었다. 10명의 radiologist들은 각자 개별적으로 140개의 이미지들(70개의 test renderings와 70개의 control renderings)을 9점의 진단 상의 품질 척도로 평가했다. EVP는 세부 대조도의 부당한 손실 없이 증가된 노출 관용도를 제공했다. 많은 영상에서 EVP는 과소 투과 영역에서의 정보의 손실을 줄여주고, 반면 과다 투과 영역의 밝게 빛나는 현상을 실제적으로 감소시켰다. 진단상의 품질 평가는 EVP image와 control image 모두 평균적으로 높았다. 그럼에도 EVP images의 평균 등위는 control image의 그것보다 1 단계 완전히 높은 범위에 있는 것으로 평가되었다. 쌍으로 그 영상들을 보면, EVP images의 76%가 일치하는 control images의 평가 단계보다 1 또는 그 이상 높은 범주인 것으로 평가되었고, 반면 control image의 6% 만이 일치하는 EVP 영상보다 우수한 것으로 평가되었다. 유사한 결과가 연구된 14개의 검사유형에 대해 획득되었다.

  • PDF

System for storing and managing CDA documents in the relational database (CDA 문서를 관계형 데이터베이스에 저장 관리하기 위한 시스템)

  • Park, Soo-Jin;Kim, Il-Kon;Cho, Hune;Kwak, Yeon-Sik
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.10b
    • /
    • pp.835-837
    • /
    • 2003
  • 본 논문에서는 병원간의 정보를 교환하기 위한 목적으로 정의된 의료 분야의 표준기관인 HL7에서 제안하는 Clinical Document Architecture(CDA)문서를 관리하기 위한 시스템을 제안한다. CDA Manager라는 이 시스템은 각 병원의 관계형 데이터베이스인 CDA local repository에서 CDA문서를 저장, 검색, 수정의 기능을 제공한다. 본 논문에서는 XML로 기술된 CDA문서의 특성을 살려 테이블을 설계하고 검색속도를 향상시켰다.

  • PDF

Transmitting/Receiving of Standard Health Data Using Bluetooth HDP on the Android Platform (안드로이드에서 블루투스 HDP를 이용한 표준건강정보의 송수신)

  • Park, Young-Jin;Cho, Hui-Sup;Son, Jong-Wuk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.5
    • /
    • pp.464-470
    • /
    • 2013
  • These days, with increasing interest about the health care, research about standard for transmitting/receiving data of health device has been actively conducted. Standardization and testing / certification is underway through the IEEE 11073 PHD, Health Level Seven and the Continua Health Alliance, it'll continue to be more research and experiments in the future. In this paper, we introduce the IEEE 11073 PHD standards for exchange of remote health information and the Bluetooth Health Device Profile(HDP) for health device profile of the Bluetooth technology, also we conducted experiments about exchange health information between health device and smart device which are adapted the IEEE 11073 PHD and Bluetooth HDP. Transmitting/receiving of the IEEE 11073 PHD standard protocol using the Bluetooth HDP profile between health device and smart device can be known by this experiment, and it expect to implement variety of remote medical services through health device supporting these standards in future.

A study on the success factors of EDI information system: Focused on medical industry (EDI 정보 시스템의 성공 모형 도출: 의료 산업을 중심으로)

  • Jo, Hyeon;Kim, Soung-Hie;Lee, Seok-Kee
    • Journal of the Korean Data and Information Science Society
    • /
    • v.22 no.2
    • /
    • pp.323-333
    • /
    • 2011
  • Recently, Electronic Data Interchange (EDI) systems are widely used. Many organizations exchange the documents by using EDI, and EDI is used in various industries such as physical distribution, export and import business, custom, and medical care. However, there have been little attempt to empirically investigate the success factors of EDI system. In this paper, we identify the influencing factors which determine the success of typical information system and then suggest the additional factors characterized to the EDI system. Our research model, mainly based on the system success model, is tested by analyzing the empirical data acquired from the companies in the medical industry. As a result, the system quality, information quality, service quality, and the perceived sacrifice turned out to be significant to the success of EDI system while data security does not. The result of this research is likely to help providing useful guidelines for the successful EDI implementations.

Design and Implementation of Message Format and Server for Interworking EMR System and Gateway of Medical Devices (의료기기 통합 게이트웨이와 EMR 시스템간의 연동을 위한 메시지 규격 설계 및 서버 구현)

  • Im, Seokjin;Hwang, Hee-Joung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.6
    • /
    • pp.255-262
    • /
    • 2013
  • Medical Gateway(MG), that integrates medical devices with its unique data format in various hospital information systems, provides effectiveness in the cost of the management unlike existing systems that uses PC as a gateway to hospital information systems because MG enables to interface medical devices with itself. However, in spite of using MG for integrating medical devices, we need additional programs or systems to interwork with EMR system of each hospital in accordance with the configuration of DB. In this paper, we design and implement the format of medical information and server system for interworking MG with EMR system. The proposed system makes easy exchanging medical data between MG and EMR system. Thus, the proposed system can contribute to a national project to export abroad advanced hospital setup converged with IT.

Design of Real-time Vital-Sign Encryption Module for Wearable Personal Healthcare Device (착용형 개인 건강관리 장치를 위한 실시간 생체신호 암호화 모듈의 설계)

  • Kim, Jungchae;Yoo, Sun Kook
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.221-231
    • /
    • 2013
  • Exchanging personal health information(PHI) is an essential process of healthcare services using information and communication technology. But the process have the inherent risk of information disclosure, so the PHI should be protected to ensure the reliability of healthcare services. In this paper, we designed encryption module for wearable personal health devices(PHD). A main goal is to guarantee that the real-time encoded and transmitted PHI cannot be allowed to be read, revised and utilized without user's permission. To achieve this, encryption algorithms as DES and 3DES were implemented in modules operating in Telos Rev B(16bit RISC, 8Mhz). And the experiments were performed in order to evaluate the performance of encryption and decryption using vital-sign measured by PHD. As experimental results, an block encryption was measured the followings: DES required 1.802 ms and 3DES required 6.683 ms. Also, we verified the interoperability among heterogeneous devices by testing that the encrypted data in Telos could be decoded in other machines without errors. In conclusion, the encryption module is the method that a PHD user is given the powerful right to decide for authority of accessing his PHI, so it is expected to contribute the trusted healthcare service distribution.

A Context Aware Model and It's Application Using Difference of Multiple-Valued Logic Functions (다치 함수의 차분을 이용한 상황 인식 모델 및 응용)

  • Go, Hyeon-Jeong;Jeong, Hwan-Muk
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2006.11a
    • /
    • pp.215-219
    • /
    • 2006
  • 최근 유비쿼터스 컴퓨팅 환경에서 핵심적인 요소 기술인 상황인식 시스템을 실현하기 위해 이에 필요한 상황정보를 수집하는데 점차 센서의 활용과 응용분야가 확대되고 있다. 상황인식 서비스는 센서로부터 수집된 상황정보의 수집 및 교환을 통해 인식하고, 해석 및 추론 과정을 거쳐 사용자에게 상황에 적절한 서비스를 제공하는 것으로 매장, 의료, 교육 등의 응용분야에서 많이 연구되고 있다. 본 논문에서는 Boole 함수 및 다치 논리함수의 미분을 이용하여 유비쿼터스 환경 하에서 주변상황 등을 인식하는 방법과 그 인식 결과를 해석하고 주변상황의 변화에 따른 적절한 서비스를 제공하는 모델을 제안하고 적용 예를 통하여 확인한다.

  • PDF