• Title/Summary/Keyword: 의료폐기물

Search Result 64, Processing Time 0.025 seconds

Measurement of Specific Radioactivity for Clearance of Waste Contaminated with Re-186 for Medical Application (의료용 Re-186 오염폐기물의 규제해제를 위한 방사능측정)

  • Kim, Chang-Bum;Lee, Sang-Kyung;Jang, Seong-Joo;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.633-638
    • /
    • 2017
  • The amount of radioactive waste has been rapidly increased with development of radiation treatment in medical field. Recently, it has been a common practice to use I-131 for thyroid cancer, F-18 for PET/CT and Tc-99m for diagnosis of nuclear medicine. All the wastes concerned have been disposed of by means of the self-disposal method, for example incineration, after storage enough to decay less than clearance level. IAEA proposed criteria for clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, specific radioactivity of radioactive waste contaminated with Re-186 was measured to confirm whether it meets the clearance level. Re-186 has long half life of 3.8 days relatively and emits beta and gamma radiation, therefore it can be applied in treatment and imaging purposes. The specific radioactivity of contaminated gloves weared by radiation workers was measured by MCA(Multi-channel Analyzer) which was calibrated by reference materials in accordance with the measuring procedure. As a result, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and physical half-life was considered, and it is showed that the physical half-life is longer than induced half-life. Therefore, the storage period of radioactive waste for self-disposal may be curtailed in case of application of induced half-life. The result of this study will be proposed as ISO standard.

Identifying Medical Waste Management Status by Different Types of Dental Institutions (치과의료기관별 의료폐기물 관리 현황 파악)

  • Seong, Mi-Ae;Park, Ji-Hye;Sakong, Joon
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.5
    • /
    • pp.452-459
    • /
    • 2018
  • Objectives: We aimed to examine whether dental waste was being managed adequately at different types of dental institutions in City D in South Korea. Methods: The staff responsible for disinfection at 101 dental offices and clinics (six dentistry departments of general hospitals, 12 dental hospitals, and 83 dental clinics) was interviewed. Results: Solid suction pump waste was handled appropriately at four of the general hospital dentistry departments (66.7%), six dental hospitals (50.0%), and 15 dental clinics (18.1%). Solid spittoon waste was handled appropriately at four general hospital dentistry departments (66.7%), seven dental hospitals (58.3%), and 14 dental clinics (16.9%). Developer and fixer were handled appropriately by a subcontractor at two general hospital dentistry departments (100.0%), five dental hospitals (100.0%), and 24 dental clinics (75.0%). Impression materials were handled appropriately at four general hospital dentistry departments (66.7%), six dental hospitals (50.0%), and 11 dental clinics (13.3%). The plastic covers of intra-oral radiography films were handled appropriately at five general hospital dentistry departments (100.0%), eight dental hospitals (72.7%), and 22 dental clinics (30.1%). Conclusion: South Korea must implement detailed and specialized guidelines for the disposal of solid and general medical waste from dental institutions. Moreover, waste disposal training should be provided annually, and not only once every three years.

Verification of the Possibility of Convergence Medical Radiation Shielding Sheet Using Eggshells (계란 껍데기를 이용한 융합 의료방사선 차폐시트의 가능성 검증)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.6
    • /
    • pp.33-38
    • /
    • 2021
  • In order to manufacture a lightweight medical radiation shielding sheet, a new shielding material was studied. We tried to verify the possibility of a shielding material by mixing egg shell powder, which is thrown away as food waste at home, with a polymer material. Existing lightweight materials satisfy eco-friendly conditions, but there are difficulties in the economics of shielding materials due to the cost of the material refining process. This study aims to solve this problem by using egg shells, which are household waste. A 3 mm-thick shielding sheet was fabricated using HDPE, a polymer material, and particle distribution within the cross-section of the shielding sheet was also verified. The shape of the particles was rough and there were voids between the particles, and the average weight per unit area was 1.5 g/cm2. The shielding performance was around 20% in the low energy area and 10% in the high energy area, showing the possibility of a low-dose medical radiation shielding body.

A case study of hospital logistic and medical wastes management's innovation (병원 물류 및 의료 폐기물 관리 혁신 사례 연구)

  • Ahn, Tae-Yong;Kim, Soon-Jo;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.3
    • /
    • pp.55-62
    • /
    • 2008
  • This is to prevent accidents that can be caused during the process of hospital logistics and accidents in relation to the traceability of medical wastes. And this is also to set up the logistic management system of medical wastes is hospital where the safety of patients shall to regard as the first priority. through these case studies effective operating plans shall be provided.

A Study of Targetry Activation and Dose Analysis of PET Cyclotron Using Monte Carlo Simulation (몬테카를로 모의 모사를 이용한 의료용 사이클로트론의 Targetry 방사화 및 피폭선량 분석)

  • Jang, Donggun;Kim, Dong hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.565-573
    • /
    • 2018
  • Cyclotron for medical purposes generates nuclear reaction by accelerating protons in high speed, in order to produce radiopharmaceuticals, and unnecessary neutrons are generated through such nuclear reaction. Neutrons cause activation in the parts of cyclotron which then cause exposure to radiation for people working in the field. This study, in that regard, aims to analyze exposure level by finding out the degree of activation of aluminum body, silver body, and havar foil which are the parts of Targetry where the nuclear reaction takes place. The results of the experiment showed that aluminum body and silver body had no problems re-using them as the energy and half-life of activated nuclides were small and short, making the affect on the people working in the field extremely low. However for havar foil, its activated nuclides had a high level of energy which resulted in high level of affect to the people working in the field. The activation factors of the cyclotron were analyzed, and the results showed that the Havar foil was activated the most among the targetry parts, and greatly exposed workers due to regular replacement, and needed special management as radioactive waste.

Dental Waste Management Practices at Dental Offices in Gyeongsangnam-do (경남지역 치과의원 의료폐기물 관리실태)

  • Kim, Hae-Jin;SaKong, Joon
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.4
    • /
    • pp.332-339
    • /
    • 2012
  • Objectives: The purpose of this study was to prevent health problems and environmental contamination resulting from inappropriate management of dental wastes and to provide reference data for revision and supplementation of dental clinic waste management guidelines. Methods: From 640 total of dental clinics registered in 16 cities and counties in Gyeongsangnam-do, 100 (60 in Changwon (Masan, Changwon), 29 in Gimhae, and 11 in Jinju) were included in this study. From July 2010 to September 2010, investigators visited the 100 dental clinics and conducted survey interviews using a structured survey questionnaire regarding disposal methods for liquid wastes (suction pump, spittoon container waste, used liquid disinfectants, and X-ray developer), and disposal methods for solid waste (suction pump, spittoon container waste, and general medical waste). Results: All the 100 dental clinics were found to treat liquid waste from suction pumps and spittoon containers in the same manner as general waste water. Nineteen percent of the clinics treated solid waste that was not filtered through the filter of a suction pump as general waste. Fifty or more percent of the clinics treated solid waste in spittoon containers as general waste. Seventy percent of the clinics used disinfectant solution, although most of them treated used disinfectants in the same manner as general waste water. Some clinics treated used X-ray developer and X-ray fixer in the same manner as general waste water. In most of the clinics, used drapes were washed within the clinic. Conclusions: It was found that waste water and dental wastes at some dental clinics were treated in inappropriately. Thus, in conclusion, the development of guidelines regarding proper management of liquid and solid dental waste at dental clinics is required, and hygiene and environmental training for workers at dental clinics is necessary.

Study on Safety Management Activity of Blood Test Room of Nuclear Medicine Department (핵의학과 혈액검사실의 안전 관리 활동에 대한 고찰)

  • Sim, Seong-Jae;Shin, Young-Kyun;Moon, Hyeong-Ho;Yoo, Seon-Hee;Jo, Shi-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.104-110
    • /
    • 2011
  • Purpose: The object evaluation method about medical institutes of these days increases credibility of consumers about medical services by conducting a certification system about medical institutes. In addition, as nuclear medicine test rooms and diagnosis test medicine room adopt many kinds of international certification systems, the matters regarding safety management of test rooms are being regarded as important. Since the blood test rooms of nuclear medicine are exposed to many harmful factors such as infection from clinical specimen and radioactive isotope reagent, there is a need to pay lots of attention to the safety management of staff and patients. Therefore, this study discusses safety management activities of staff and patients, which are conducted in the blood test rooms of the nuclear medicine department in Asan Medical Center. Materials and Methods: In the blood test rooms of the nuclear medicine department in Asan Medical Center, the matters regarding comprehensive safety management by the person in charge of safety management are offered and all staff members of the test rooms apply them into work. Safety management education is regularly conducted according to established regulations, and infection is prevented through implementation of wearing personal protectors and hand sanitation during test work. In addition, technical safety guides and accident guides for interruption of electric power are provided against emergencies. Through infection management guides, infection prevention and preparation methods for infection are learned and radioactive isotope management, safety management about reagent use and safety guides about harmful chemical substances are being applied to work. Results: The blood test rooms of the nuclear medicine department apply safety management regulations to work. Under the situation where hand sanitation should be conducted, hands are washed to prevent infection between staff and patients, and for preventing infection from clinical specimen, personal protectors are worn. The reagent, which is classified as harmful substance, is separately stored to be easily recognized, radioactive wastes and general medical wastes are also safely managed. Through these lots of safety management activities, safety management awareness of staff members is enhanced, and patients are protected from many dangers. Conclusion: Staff members of the blood test rooms of the nuclear medicine department should be fully aware of safety management regulations and apply them to work. When better safety management suggestions are made, they need to be examined and applied for increasing quality of safety management for staff and patients.

  • PDF

A Study on Control Status of Radioactive Waste Products in Medical Institution (의료용(醫療用) 방사성폐기물(放射性廢棄物)의 관리현황(管理現況))

  • Kim, Chang-Kyun;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.18 no.1
    • /
    • pp.81-90
    • /
    • 1995
  • This study was conducted to find out the management status of radioisotopes and radioactive waste products in Korean medical institutions during the period of three years from 1991 to 1993. The results are summarized as follows : 1. The rate of medical institution to the institutions making use of radioisotopes was decreased every year, for example, 18.11 % in the year 1991, 17.86 % in the year 1992 and 15.87 % in the year 1993. 2. The use of domestic made radioisotopes in the medical institution was increased every year, for instance, 89.68 % in the year 1991, 94.21 % in the year 1992 and 99.79 % in the year 1993. 3. 91.01 % of the half life of isotopes used in the medical Institution were two month below. 4. The rate of radioactive waste products in the medical institution to all radioactive waste products was increased every year, for example, 54.44 % in the year 1991, 75.36 % in 1992 and 78.49 % in the year 1993. 5. The rate of inflammable waste products from medical institution was 76.47 % of all inflammable waste products, and 73.99 % of whole waste products was from the medical Institution.

  • PDF

Current Status of Collection and Recycling of Used Plastics (폐플라스틱의 수거 및 재활용 현황)

  • 나근배
    • Resources Recycling
    • /
    • v.6 no.2
    • /
    • pp.47-59
    • /
    • 1997
  • Thc paper points oul ever increasing amounts of plastics used in dex, clopmg countries and the prohlelns associated with such increase. Tl~e current status of the production and usc of plaslic materials is reviewed. Also reviewed lncludc thc pahcicies and gu~dclmcs canccrning the treatment of used plastics which have already bccn mstitutcd.

  • PDF

Development of Evaluation Index for Infection Control and Prevention at Dental Hospital and Its Validity Verification (치과의료기관 감염관리 평가지표 개발 및 타당성 검증)

  • Bae, Sung-Suk;Lee, Myung-Sun
    • Journal of dental hygiene science
    • /
    • v.13 no.3
    • /
    • pp.254-263
    • /
    • 2013
  • This study is to develop an evaluation index for infection control and to verify its validity by examining each set of weighted data collected from 121 infection control personnel at dental hospitals who agreed to the preliminary survey and advisory. The study was conducted from 14th December, 2010 to 31st January, 2011, and PASW Statistics 18.0 and AMOS 5.0 had been used for the statistical data analysis. As a result of the study, five evaluation factors with 21 sub-indicators have been identified at structural level, eight evaluation factors with 32 sub-indicators at processing level, and one evaluation fact with five sub-indicators at resulting level, total 14 evaluation factors with 58 sub-indicators throughout all levels. The path analysis added on the result that 'standard precautions ($x_1$)', 'infection control support system ($x_2$)', 'internal and external characteristics ($x_3$)' are exogenous variables that affect on other variables, and 'standard infection control ($y_1$)','Organization equipment management handwashing ($y_2$)', 'environmental infection control ($y_3$), 'personal protective equipment ($y_4$)', 'waste and laundry management ($y_5$)' are endogenous variables that are infulenced by others. The standardized metrics are more needed than anything else when examining on infection control. This study attempts to develop proper dental infection control metrics adequately adjusted for domestic circumstances, and therefore to contribute to effective systematic management and decision-making in infection control.