• Title/Summary/Keyword: 의료선

Search Result 624, Processing Time 0.02 seconds

Concepts and Legal Problems Related to the Health-vulnerable Class, and Measures to Ensure Health (건강취약계층의 개념과 법적 문제점, 그리고 건강보장을 위한 방안)

  • Kim, JESUN
    • The Korean Society of Law and Medicine
    • /
    • v.22 no.3
    • /
    • pp.125-144
    • /
    • 2021
  • The purpose of this study is to present a legal improvement plan for health protection of the health-vulnerable class in our society in the 'COVID-19'. The contents of the first study examined the meaning of the existing (social) vulnerable class, and then critically considered the health-vulnerable class as an expanded concept in connection with the social risk of health. The term "vulnerable class" tends to have both meaning as the traditionally marginalized class such as the elderly, the disabled, and women, as well as the condition of having no ability to live due to low income, such as the low-income class. The concept of the health-vulnerable class is meaningful in that it appears as a recently expanded concept as it is linked to the concept of the vulnerable class and social risks such as health threats. The content of the second study looked at the problems that appeared when the health-vulnerable class was used together with the health care-vulnerable class in laws. Due to the laws used in both terms, there was a problem that the social security system related to health and health care could create blind spots. The contents of the third study suggested legal improvement directions for social security measures for health for the underprivileged.

The Experimental Study of the Effective Point of Measurement for Cylindrical Ion Chamber -For Medical Electron Beams- (원통형 전리함의 유효 측정점에 관한 실험적 연구 -의료용 전자선을 중심으로-)

  • 이병용;최은경;장혜숙;홍석민;이명자;전하정
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.155-160
    • /
    • 1991
  • We have studied the effective point of measurement for cylindrical ion chamber in water phantom for medical electron beams. Markus parallel plate chamber water phantom are used for the measurement of depth dose to determine the depth of the effective point of measurement for various energies(for electron 6MeV, 9MeV, 12MeV, 16MeV, and 20MeV; Co-60; for photon 6MV, 15MV). Cylindrical ion chambes(PTW233643 with r=2.75mm, PR-05P with r=2mm, and PM30 wiht r=15mm are used for the measurement of depth dose by same mtethod and the values of d$\_$50/ and R$\_$p/ obtained by three cylindrical chambers were compared with those of a flat chamber. From this we could evaluate the effective measuring points of cylindrical ion chamber. The effective point of measurement was estimated as 0.4~0.6r shifted toward surface from the center of the chamber for electron beam, 0.3~0.7r for $\^$60/Co X-ray.

  • PDF

DWT Analysis of Scatter-Ray Due to the Changed Energy on Digital Medical Images (디지털 의료영상에서 에너지 변화에 따른 산란선의 DWT 분석)

  • Kim, Jisun;Jung, Jaeeun;Ahn, Byeoungju
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.2
    • /
    • pp.65-74
    • /
    • 2014
  • This study extracts characteristics of signal by wavelet transform to prove that the Compton scattering, occurred by changed the energy, influenced a picture. We also analyzed the extracted data and evaluated how much the picture of scatter-rays was affected by a change of tube voltage. For this study, we wrote a program with MatLap which is engineering tool and evaluated with the program on variation of scattered-rays due to increased tube voltage. The evaluation result shows both CR and DR have frequency changes of high frequency area by tube voltage variations and it proved that Compton scattering influences the picture. In conclusion, according to this study indicates that DR is more sensitive to radiation with high energy than CR. Therefore, the research on DR detector needs to be advanced as actual condition of clinical setting is being changed to DR circumstance gradually. From the result of this study, we expect that assessment method of the image quality using MatLab Tool becomes the official assessment method and very useful method.

Calculation of Energy Spectra for Electron Beam of Medical Linear Accelerator Using GEANT4 (GEANT4를 이용한 선형가속기 기초 코드 작성과 전자선 에너지 분포 계산)

  • Joh, Young-Gull;Kim, Hyung-Dong;Kim, Byung-Young;Kim, Sung-Jin;Oh, Se-An;Kang, Jeong-Ku;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.85-91
    • /
    • 2011
  • The energy spectra for electron beam of medical linear accelerator were calculated using a GEANT4 Medical Linac 2 example code. The incident electron mean energy were 6, 9, 12, 16, 20 MeV. This code was designed to calculate electron beam energy spectra according to material, thickness and location of electron scattering foil affecting electron beam characteristic. Lead, Copper, Aluminum and Gold were used for scattering foil. The energy distribution for electron and photon were analyzed by changing position of scattering foil in the head of linear accelerator. The effect of electron scattering foil on energy spectra which is basic data of simulation for medical linear accelerator were presented. The calculated results would be used in design of medical accelerator head.

Effects of Antioxidant and Thermal Treatment on the Radiation Resistance of Polypropylene (폴리프로필렌의 내방사선성에 미치는 산화방지제와 열처리의 영향)

  • Park Sung Hyun;Kim Hyung-Il;Kang Phil Hyun;Nho Young Chang
    • Polymer(Korea)
    • /
    • v.30 no.1
    • /
    • pp.10-13
    • /
    • 2006
  • The effects of antioxidants and thermal treatment on the radiation resistance of the gamma-ray irradiated polypropylene (PP) were studied. The PP was blended with various antioxidants and was fabricated into a sheet. The PP sheet was irradiated with gamma-ray to a dosage of 25kGy in the nitrogen atmosphere. The differences in both color and mechanical strength were investigated for the gamma-ray irradiated PP depending on the kind and the content of antioxidant. The residual amount of free radical and the variation of oxidation index were investigated for the gramma-ray irradiated PP with thermal treatment after irradiation. The PP having phosphite antioxidant showed little difference in color after gamma-ray irradiation compared with the PP having phenolic or mine antioxidant. Sufficient amount of free radical could be removed from the gamma-ray irradiated PP by the thermal treatment at $130\;^{\circ}C$ for 30 min. Thermally treated PP showed lower oxidation index than the PP without thermal treatment.

A Method for Region-Specific Anomaly Detection on Patch-wise Segmented PA Chest Radiograph (PA 흉부 X-선 영상 패치 분할에 의한 지역 특수성 이상 탐지 방법)

  • Hyun-bin Kim;Jun-Chul Chun
    • Journal of Internet Computing and Services
    • /
    • v.24 no.1
    • /
    • pp.49-59
    • /
    • 2023
  • Recently, attention to the pandemic situation represented by COVID-19 emerged problems caused by unexpected shortage of medical personnel. In this paper, we present a method for diagnosing the presence or absence of lesional sign on PA chest X-ray images as computer vision solution to support diagnosis tasks. Method for visual anomaly detection based on feature modeling can be also applied to X-ray images. With extracting feature vectors from PA chest X-ray images and divide to patch unit, region-specific abnormality can be detected. As preliminary experiment, we created simulation data set containing multiple objects and present results of the comparative experiments in this paper. We present method to improve both efficiency and performance of the process through hard masking of patch features to aligned images. By summing up regional specificity and global anomaly detection results, it shows improved performance by 0.069 AUROC compared to previous studies. By aggregating region-specific and global anomaly detection results, it shows improved performance by 0.069 AUROC compared to our last study.

A study on the calculation of the shielding wall thickness in Medical Linear Accelerator (의료용 선형가속기 차폐벽의 두께 산정에 관한 연구)

  • Lee, Dong-Yeon;Park, Eun-Tae;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.281-287
    • /
    • 2017
  • The purpose of this study is to calculate the thickness of shielding for concrete which is mainly used for radiation shielding and study of the walls constructed to shield medical linear accelerator. The optimal shielding thickness was calculated using MCNPX(Ver.2.5.0) for 10 MV of photon beam energy generated by linear accelerator. As a result, the TVL for photon shielding was formed at 50~100 cm for pure concrete and concrete with Boron+polyethylene at 80~100 cm. The neutron shielding was calculated 100~140 cm for pure concrete and concrete with Boron+polyethylene at 90~100 cm. Based on this study, the concrete is considered to be most efficient method of using steel plates and adding Boron+polyethylene th the concrete.

Acceptance Test and Quality Control of Radiotherapy Treatment Simulator (의료용 모의치료기의 품질관리에 관한 연구)

  • 신동호;박성용;신동오;최진호;김유현;권수일
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.90-97
    • /
    • 2002
  • The simulator which has a identical geometry with radiotherapy equipments, is a essential equipment to accomplish optimized radiotherapy plan through simulation by using diagnostic low energy X-ray. A Radiotherapy simulator has a combined technology from the therapeutic and diagnostic radiology and needs a periodical test for mechanical and optical properties, X-ray generator, image intensifier of simulator to keep the proper maintenance and radiation safety. Hence, tests were done and classified as i) mechanical and optical parameter for the gantry, collimator, and couch ii) key performance of the X-ray generator such as a kVp, mAs, and timer iii) performance of the image intensifier such as a resolution and contrast for three kinds of simulator, common use in clinic. The above result of tests will be applied to the acceptance test and periodical quality assurance procedure.

  • PDF

Detecting Regions of Stenosis and Aneurysm in a 3D Blood Vessel Model (3차원 혈관 모델에서 협착 및 팽창 영역 탐색 방안)

  • Park, Sang-Jin;Kim, Jae-Sung;Park, Hyungjun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.113-120
    • /
    • 2018
  • Angiography and CT angiography are used widely for the examination of vascular diseases, but the diagnosis of such diseases is made mostly by the subjective judgment of the inspector. This paper proposes a method for detecting the suspicious regions of stenosis and aneurysm in the inner surfaces of 3D blood vessel models reconstructed from medical images. Initially, the 3D curve-skeletons of the blood vessel models and the contours at the nodes of the curve-skeletons were generated. Next, the 3D curve-skeletons were divided into a set of branches and the areas of normal contours of nodes located in each branch were calculated. The nodes whose contours contain suspicious regions were detected by taking into account the average area, maximum and minimum areas, and the area difference between the adjacent normal contours. The diagnosis of stenosis and aneurysm can be supported by properly visualizing the suspicious regions detected. The suspicious regions of the disease were identified by implementing and testing it using several data sets of human blood vessels, highlighting the usefulness of the proposed method.

A Comparative Study of Image Quality and Radiation Dose according to Variable Added Filter and Radiation Exposure in Diagnostic X-Ray Radiography (진단용 X-선 촬영시 부가 필터 및 노출의 변화에 따른 피폭선량 및 영상 화질 비교 연구)

  • Choi, Nam-Gil;Seong, Ho-Jin;Jeon, Joo-Seop;Kim, Youn-Hyun;Seong, Dong-Ook
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.25-34
    • /
    • 2012
  • To know which parameters were acceptable for achieving lowest radiation exposure to the patients and highest image quality at the diagnostic X-ray radiography, we measured the patient radiation dose and image quality in transmitted PACS (Picture Archiving and Communication System) at variable combinations of the added filters. As a result, the Dose Area Product (DAP: $mGy{\cdot}cm^2$) and Entrance Surface Doses (ESDs: $mGy$) was lowest at 1 mmAl + 0.2 mmCu and highest at 0 mmAl. The histogram of the image quality by transmitted PACS was not significantly different at variable combinations of exposure parameters on the MATLAB. In conclusion, this study can be helpful for expecting radiation dose-exposure and control exposure parameters for the diagnostic X-ray radiography.