• Title/Summary/Keyword: 의료기구

Search Result 241, Processing Time 0.026 seconds

Development of Biopsy Assist Device on Computed Tomography Using 3D Printing Technology (3D 프린팅 기술을 이용한 전산화단층영상 기반 조직 생검 보조기구 개발)

  • Jeong-Wan Kim;Youl-Hun Seoung
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.151-157
    • /
    • 2023
  • The purpose of this study was to develop an assist device that could correct and support patient position during biopsy on computed tomography (CT) using 3D printing technology. The development method was conducted in the order of 3D design, 3D output, intermediate evaluation for product, final assist device evaluation. The 3D design method was conducted in the order of prior research data survey, measurement, primary modeling, 3D printing, output evaluation, and supplementary modeling. The 3D output was the 3D printer (3DWOX 2X, Sindoh, Korea) with additive manufacturing technology and the polylactic acid (PLA) materials. At this time, the optimal strength was evaluated to infill degree of product as the 3D printing factors into 20%, 40%, 60%, and 80%. The intermediate evaluation and supplementation was measured noise in the region of interest (ROI) around the beam hardening artifact on the CT images. We used 128-channel MDCT (Discovery 75 HD, GE, USA) to scan with a slice thickness of 100 kVp, 150 mA, and 2.5 mm on the 3D printing product. We compared the surrounding noise of the final 3D printing product with the beginning of it. and then the strength of it according to the degree of infill was evaluated. As a result, the surrounding noise of the final and the early devices were measured at an average of 3.3 ± 0.5 HU and 7.1 ± 0.1 HU, respectively, which significantly reduced the noise of the final 3D printing product (p<0.001). We found that the percentage of infill according to the optimal strength was found to be 60%. Finally, development of assist devices for CT biopsy will be able to minimize artifacts and provide convenience to medical staff and patients.

Development of gripping force and durability test standard for myoelectric prosthetic hand (근전전동의수의 파지력 및 내구성 시험 표준 개발)

  • Gook Chan Cha;Suk-Min Lee;Ki-Won Choi;Sangsoo Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.393-399
    • /
    • 2023
  • Upper limb amputees wear an upper limb prosthesis for both aesthetic purposes and functional necessity, and in particular, in the case of amputee with both hands, it is essential to wear a myoelectric prosthetic hand capable of gripping action. The prosthetic hand operated by the EMG signal of the remaining muscles is a public insurance benefit item of the Industrial Accident Compensation Insurance, and test method standards are needed to be developed for the safety of the user and the effectiveness of the product performance. In this study, we developed systems for measuring the gripping force of myoelectric hand prosthesis by a load cell and for durability test of the prosthesis over repeated use with a proximity sensor, and propose a test method standard. Since the international test method standard has not yet been established, it is expected that Korea will be able to play a leading role in this standardization field in the future.

A Study on Radiation Dose for General Radiography Examination at First Medical Institution (Around the Radiology Clinic of National Capital Region) (일차 의료기관에서 일반촬영 검사의 피폭선량 연구 (수도권 영상의학과를 중심으로))

  • Hwang, Su-Lyun;Jung, Hong-Ryang;Lim, Cheong-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.245-253
    • /
    • 2011
  • The hazard level will be increased with the augmentation of the dose received by patients. Therefore, patients radiation dose have been analyzed by this study for the radiology clinics located at Seoul and Gyeongin area from August 2009 to September 2010. In the case of the front and rear directional inspection of skull, patient radiation dose was turned out to be 1.75mGy for radiology clinic, 3.00mGy for UK, 3.00mGy for Japan, and 5.00mGy for Germany, therefore, radiology clinic was the lowest. In the case of lateral directional inspection of skull, patient radiation dose was turned out to be 1.49mGy for radiology clinic, 1.50mGy for 3rd medical institution, therefore, radiology clinic was measured lower, and it was lower than 3.00mGy which is the recommended dose of IAEA. In order to reduce medical exposure of patient, optimization of efficient protection of radiation and reduction of medical radiation exposure are thought to be required by observing recommendation of international organization based on the result of this study.

Recognition of Medical Consumer over the Infection Control of Dental Clinic (감염관리에 관한 치과의료소비자들의 인식도)

  • Kim, Ji-Hwa;Kim, Gi-Wook
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.11
    • /
    • pp.306-312
    • /
    • 2013
  • The purpose of this study was to grasp the recognition of medical consumer over the infection in dental clinic. The study performed the questionnaire by selecting the patients visiting 3 dental clinics of Daegu area as targets and analyzed 213 question papers collected. The result revealed that the infection control, which was most important for the patients, was 'instrument disinfection' (64.3%) and it was significant in age factor(P<0.01). For the responsibility of infection control, 72.3% replied that 'dentist or dental clinic staff' should be responsible for it and it was significant in academic background factor(P<0.001). For the importance of cleaning and sanitation, 70.0% replied that 'it is very important' and it was gender(P<0.05)and the age factor.((P<0.01) The person who experienced the information about the infection control of dental clinic observed hand washing(P<0.001), replacement of suction tip(P<0.001) and replacement of teeth washing cup (P<0.01) more carefully and considered whether dentist wears protective goggle more importantly than the person who did not experience it(P<0.01). If dental clinic recognizes the evaluation of infection control notified by the Ministry of Health & Welfare and performs the infection control suitable for the eye level of general medical consumer on the basis of the study result above, it can improve the reliance of hospital as well as patient's satisfaction.

Appropriate Technology, Responding to the COVID-19 Pandemic - Redefined Roles in a Public Health Crisis (Part II) (COVID-19 대유행에 대응하는 적정기술 : 보건 위기에서 재정의된 역할 - 파트 2)

  • Pyun, Nayoon;Lee, Sungwoo;Suh, Jungwoo;Kim, Jaeeun;Jang, Dongyoon;Shin, Kwanwoo
    • Journal of Appropriate Technology
    • /
    • v.6 no.2
    • /
    • pp.256-270
    • /
    • 2020
  • The collapse of the medical and healthcare system in the pandemic is resulting in the voluntary participation of civil society and a new way of responding. Some of new countermeasure can be immediately utilized at the forefront of the health crisis. Appropriate technology is no longer an intermediate technology, demonstrating its role as a technology capable of overcoming the crisis of not only developing countries but also any countries where the health system has collapsed. In this Part 2, examples of health fields such medical devices as negative pressure chambers and ventilators, diagnostic chips, and diagnostic techniques, are being discussed as a quick response to the collapse of health systems under COVID-19, within the framework of appropriate technologies. Finally, the important role of scientists and engineers is discussed for the prevention of severe impacts on the vulnerable people in terms of socioeconomic status.

Implementation of Multichannel Digital Hearing Aid Algorithm Development Platform using Simulink (Simulink 기반 다채널 디지털 보청기 알고리즘 개발 플랫폼 구현)

  • Byun, Jun;Min, Ji-hwan;Cha, Tae-hwan;Ji, You-na;Park, Young-cheol
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.2
    • /
    • pp.205-212
    • /
    • 2016
  • In this paper, we implement the development platform of multichannel digital hearing aid algorithm using Simulink provided by Matlab. The digital hearing aids are considered medical devices designed to compensate for hearing loss, they need to be correctly selected, to help a person who has difficulty in hearing. The development platform that implemented in this paper, includes WOLA filterbank for analysis/synthesis of input signal, Wide dynamic range compression for hearing loss compensation and adaptive filter for feedback cancellation. Using the development platform, algorithm parameters for each block can be set depending on the hearing aid user. Thus it is possible to test the algorithm before the machine language. As a result, the time for algorithm development can be saved and performance and computational complexity can be optimized.

A Study on Recognition of Infection Control among Dental Staff (치과의료종사자들의 감염방지에 대한 인식)

  • Park, Hyun-Sook;Bae, Ji-Young;Lee, Yeong-Ae;Jo, Min-Jung
    • Journal of dental hygiene science
    • /
    • v.7 no.4
    • /
    • pp.257-262
    • /
    • 2007
  • This study aimed at recognition on infection control among dental staff. This investigation was implemented by survey and questionnaires on 50 dentists and 176 dental hygienists and 100 aide nurses who were working in Deagu. The results is 1. Dental staff was recognition that extremely dangerous infectious disease is hepatitis B in dental clinic. 2. Wearing gloves and rubber dam was high in degree of recognition on using of personal protective gears however, put on apron was low. 3. The degree of recognition about sterilization of dental instruments was more higher on dentist and dental hygienists than aide nurse. 4. Dental hygienists were higher than other groups on degree of recognition about managing of dental equipment's surface.

  • PDF

The Status of Accidents and Management for Electronic Assistive Devices among the Handicapped (장애인 전동보조기구 사고 및 관리현황에 관한 연구)

  • Kim, Deok-Ju;Lee, Hye-Jin;Yang, Yeong-Ae
    • The Korean Journal of Health Service Management
    • /
    • v.10 no.3
    • /
    • pp.223-234
    • /
    • 2016
  • Objectives : The purpose of this study was to investigate accident cases involving electronic assistive devices, to determine how these accidents can be avoided and to devise preventative instructions for the handicapped who use these devices. Methods : This study was carried out from July 20 to October 3, 2015. A consent-based survey was conducted via mail and mobile phones targeting 700 electronic assistive device users, of which questionnaires from 290 users were collected and used in the analysis. Results : Accidents involving electronic assistive devices were investigated, especially the causes of the accidents and accident prevention education, as well as the status of the electronic assistive devices. The most common accident types were collision and falling, and it was found that the victims of the accidents usually suffered severe injury to their lower limbs. Most users used electronic assistive devices every day but rarely wore a safety belt because of discomfort. There were more incidents of collision and falling for older aged handicapped users, and the injury rate to the lower limbs was highest in handicapped elderly aged 50 years or older. Conclusions : In order to prevent accidents with electronic assistive devices in the future, a or management organizations must prepare specific safety guidelines and manage these accidents.

Development of Infrared Imaging Measurement Device for Internal Red Ginseng Analysis. (홍삼 내부 분석을 위한 적외선 영상 측정기기 개발)

  • Park, Jaeyoung;Kim, Taehoon;Jung, Seokhoon;Kim, Donggeun;Cho, Se-Hyoung;Han, Chang Ho;Lee, Sangjoon;Lee, Ji Yeon;Ko, Kuk Won
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.04a
    • /
    • pp.573-576
    • /
    • 2017
  • 본 연구는 홍삼 등급판정 과정에서 내부 조직 치밀도 분석을 위해 의료 영상 분석 방법을 이용하여 적외선 영상 측정기기를 개발하였다. 기존 홍삼 내부분석방법은 수동으로 암실환경에서 강한 조명을 홍삼에 투과하여 사람 눈으로 직접 판별하는 과정을 거친다. 이러한 기존 검사 과정은 작업 비효율성과 불균일한 검사기준으로 제품 품질 신뢰도 저하의 단점을 가져온다. 이러한 문제점을 해결하기 위해 본 연구는 적외선 조명환경에서 자동 측정이 가능한 홍삼 내부 측정기기를 개발하였다. 개발된 장치는 홍삼의 빛 투과 특성을 응용한 920nm 파장대역의 적외선 조명기구, 조명 제어회로, 적외선 대역 촬영이 가능한 영상 측정 카메라 장치, $0.9^{\circ}$의 간격으로 $360^{\circ}$ 홍삼 영상취득이 가능한 회전 엑츄에이터로 구성이 된다. 본 연구에서 제안 하는 홍삼 단층 영상분석 방법은, 홍삼을 $0.9^{\circ}$ 간격으로 회전시키어 $360^{\circ}$ 홍삼 내부영상을 취득하여 라돈 변환(Radon transform)을 통해 사이노그램(Sinogram)으로 재구성 하였으며, 역 라돈 변환(Inverse Radon transform)을 통해 단층 영상복원(Back-projection)알고리즘을 구현하였다. 이 결과 홍삼을 절단하지 않고 홍삼 내부 단면영상 획득이 가능하였으며 내공(內空), 내백(內白)의 유무를 판단하고 직경을 파악할 수 있었다. 이를 토대로 등급 판별 공식을 산출하면 신뢰성 있는 홍삼 등급 자동화 측정기기를 개발할 수 있을 것으로 기대된다.

Design of Oxygen Chamber System for Diagnosis and Treatment of Cold Hypersensitivity (냉증을 진단하고 치료하는 산소챔버 시스템의 설계)

  • Cho, Myeon-Gyun;Choi, Hyo Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.6013-6021
    • /
    • 2012
  • Although there are many patients who suffer from cold hypersensitivity and have a difficult time in living daily lives due to feeling cold at room temperature, it is about true that an accurate diagnostic method and an effective remedy for a cold hypersensitivity have not been developed yet. Therefore, in order to develop traditional medicine equipment for cold hypersensitivity, we have designed new oxygen chamber system which can diagnose cold hypersensitivity with multiple bionic sensors and supply a patient optimum amount of oxygen adaptively to the extent of their illness. In particular, diverging from conventional diagnosis based on the experience of doctor and subjective statements of patient, we introduced accurate method for diagnosis in comparing between output of multiple sensors and threshold derived from clinical trials. After all, the proposed oxygen chamber system will contribute to achieving scientific evidence and manufacturing of korean traditional medicine.