• Title/Summary/Keyword: 응집 공정

Search Result 484, Processing Time 0.022 seconds

Water Quality Variation on the Unit Operation of Water Treatment Process When CCPP Index was Controlled for Internal Corrosion of Water Pipes (수도관 내부부식방지를 위한 CCPP 조절시 정수공정내에서의 수질변화)

  • Lee, Jae-In;Kim, Do-Hwan;Lee, Ji-Hyung;Kim, Dong-Youn;Hong, Soon-Heon;Shin, Pan-Sae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.362-368
    • /
    • 2005
  • The pH, alkalinity and calcium hardness could be adjusted by $CO_2$, $Ca(OH)_2$, and $Na_2CO_3$ addition in the water treatment process for corrosion protection of the water pipes. This research was performed to investigate the effect on the variation of water quality on the unit process by addition $CO_2$, $Ca(OH)_2$, and $Na_2CO_3$ in water treatment process. Carbon dioxide and lime were added before the coagulation basin and soda ash was added after the BAC process. pH and aklainity were increased at coagulation basin then after the water qualities had sustained similiarly to BAC process. There was no effect on turbidity and DOC removal efficiency during experimental period by addition\ $CO_2$, $Ca(OH)_2$, and $Na_2CO_3$ solution was added into clear well, the last process for optimum control of CCPP and is used mainly to control pH and alkalinity. In this research, average pH, alkalinity, and calcium hardness in treated water were 8.39, 61.4 mg/L as $CaCO_3$, 59.4 mg/L as $CaCO_3$, respectively and CCPP of treated water was higher than 29.5 mg/L to BAC process water, so adjusted water was expected to prevent internal corrosion of water pipe.

Optimizing Coagulation Conditions of Magnetic based Ballast Using Response Surface Methodology (반응표면분석법을 이용한 자성기반 가중응집제의 응집조건 최적화)

  • Lee, Jinsil;Park, Seongjun;Kim, Jong-Oh
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.12
    • /
    • pp.689-697
    • /
    • 2017
  • As a fundamental study to apply the new flocculation method using ballast in water treatment process, the optimal conditions for general and ballast coagulant dosage, and pH, which are known to have a significant influence, were derived by response surface methodology. Poly aluminum chloride (PAC) and magnetite ballast were used as a general coagulant and ballast, respectively. Coagulation experiments were performed by jar-tester using the kaolin based synthetic water. The effects of three independent variables (pH, PAC, and ballast) on response variables (turbidity removal rate and average settling velocity of flocs) and the optimum condition of independent variables to induce the optimum flocculation were obtained by 17 experimental conditions designed by Box-Behnken procedure. After performing experiments, the quadratic regression model was derived for each of response variables, and the response surface analysis was conducted to explore the correlation between independent variables and response variables. The $R^2$ values for the turbidity removal rate and the average settling velocity were 0.9909 and 0.8295, respectively. The optimal conditions of independent variables were 7.4 of pH, 38 mg/L of PAC and 1,000 mg/L of ballast. Under these conditions, the turbidity removal rate was more than 97% and the average settling velocity exceeded 35 m/h.

Separation of Non-covalently Functionalized Graphene Nanoplatelets via Salting-out Process (염석법을 이용한 비공유 기능기화된 그래핀 나노플레이트렛의 분리 공정 연구)

  • Kim, Joonhui;Yoo, Sung Chan;Cha, Jaemin;Ryu, Hojin;Hong, Soon Hyung
    • Composites Research
    • /
    • v.32 no.3
    • /
    • pp.134-140
    • /
    • 2019
  • Graphene nanoplatelets (GNP), one of the graphene derivatives is famous as the most proper candidate for industrial applications. However, current performance of GNPs as reinforcing filler in composites is limited by their agglomeration and physicochemical heterogeneity. Herein, an approach to produce non-covalently functionalized GNPs (F-GNPs) is reported which possesses potential to be extended as the industrial level of mass production. The one-step functionalization process uses melamine, a low-cost chemical, to prevent agglomeration and dispersion in polar solvents. Furthermore, a purification strategy called salting-out process based on differences in the dispersibility of the individual F-GNP flakes is reported to separate F-GNPs. The functionalization and separation process developed in this paper provides a strategy to use GNPs at the industrial level in composite applications.

Evaluation Model of the Automation Level of Smart Water Treatment Plant (스마트 정수처리장의 자동화수준 평가모델)

  • Son, Sang Hyeok;Kim, Sun Woo;LEE, Jong Yun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.05a
    • /
    • pp.285-288
    • /
    • 2021
  • 4차 산업혁명의 출현과 함께 스마트공장, 스마트시티, 스마트러닝 등이 등장하면서 스마트 물관리시스템과 그 평가지표의 연구개발이 주요 사회문제로 대두되고 있다. 따라서 본 논문에서는 스마트 물 관리시스템의 자동화 수준 평가지표를 제안하고자 한다. 그 세부 연구내용은 다음과 같다. 첫째, 기존의 CMM과 SPICE 소프트웨어 프로세스 평가모델과 스마트공장의 평가지표를 검토하고, 스마트 정수처리장의 개념을 살펴본다. 둘째, 제안하는 스마트 물관리시스템의 평가지표에는 정수장의 주요 공정에 따라 착수 공정, 약품투입 공정, 혼화·응집 공정, 침전 공정, 여과 공정, 소독 공정의 6개 평가영역으로 세분화 하였고, 각 평가영역별로 0에서 4까지의 5단계 평가수준으로 구분하여 제안하였다.

Removal Mechanism of Phosphorus in Wastewater Effluent using Coagulation Process (응집공정을 이용한 하수처리수 중의 인 제거 Mechanism)

  • Han, Seung-Woo;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.8
    • /
    • pp.774-779
    • /
    • 2010
  • The experimental results for the analysis of aluminum hydrolysis species with PACls (polyaluminum chloride) prepared by different basicity (r value) showed that monomeric Al species were reduced while polymeric Al species were increased with an increase in basicity for PACls. The PACl with 2.2 of r value contained the highest amount of polymeric Al species. According to the experimental results for the phosphorus removal, the alum and PACl (r=0), which consisted of mainly monomeric Al species, were the most effective for phosphorus removal. Therefore, it was concluded that the Al coagulant containing higher amount of monomeric or lower molecular Al species would be more beneficial for phosphorus removal.

Removal of Dissolved Organic Nitrogen from Surface Water and Reclaimed Water by Coagulation (지표수 및 재이용수내 용존 유기질소의 응집처리)

  • Lee, Wontae;Choi, June-Seok;Oh, Hyun Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.11
    • /
    • pp.729-734
    • /
    • 2012
  • During chlorination processes dissolved organic nitrogen (DON) can form toxic nitrogenous disinfection byproducts and organic chloramines which have little or no bactericidal activity. DON needs to be removed before chlorination processes to reduce the formation of those products. This study investigated the removal of DON from surface water and reclaimed water by coagulation with aluminum sulfate (alum) and a cationic polymer (polyDADMAC). Removal characteristics of dissolved organic carbon (DOC) and ultraviolet absorbance at 254 nm ($UVA_{254}$) were compared with that of DON. Coagulation with alum removed DON, DOC, and $UVA_{254}$ with similar trends, but the removal of $UVA_{254}$ was highest. A dual coagulation strategy of alum and cationic polymer improved the removal of DON. Coagulation with cationic polymer alone was not effective due to its narrow range of charge neutralization. DON in reclaimed water was easier to remove than that in surface water, and higher molecular weight fraction (>10,000 Da) of DON was preferentially removed.

Characteristics of Coagulants Distribution by the Pumping Rate in Pump Diffusion Mixer (Pump Diffusion Mixer에서 압력수량에 따른 응집제 확산분포 특성)

  • Park, Youngoh;Kim, Ki-Don;Park, No-Suk;Lim, Jae-Lim;Lim, Kyung-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.65-71
    • /
    • 2008
  • This study collected the latest 30-year (1976~2005) continuous rainfall data hourly recorded at 61 meterological observatories in Korea, and the continuous rainfall data was divided into individual rainfall events. In addition, distribution charts of average rainfall event-depth were created to facilitate the application to the overflow risk-based design of detention storage basin. This study shows that 4 hour is appropriate for SST (storm separation time) to separate individual rainfall events from the continuous rainfall data, and the one-parameter exponential distribution is suitable for the frequency distribution of rainfall event depths for the domestic rainfall data. The analysis of the domestic rainfall data using SST of 4 hour showed that the individual rainfall event was 1380 to 2031 times, the average rainfall event-depth was 19.1 to 32.4mm, and ranged between 0.877 and 0.926. Distribution charts of average rainfall event-depth were created for 4hour and 6 hour of SST, respectively. The inland Gyeongsangbuk-do, Western coastal area and inland of Jeollabuk-do had relatively lower average rainfall event-depth, whereas Southern coastal area, such as Namhae, Yeosu, and Jeju-do had relatively higher average rainfall event-depth.

The Sludge Conditioning and Dewatering Properties of Waste Sludge with Metal Salt (금속염 응집제를 이용한 폐 슬러지 개량 및 탈수 특성)

  • Lee, Chang-Han
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.8
    • /
    • pp.775-780
    • /
    • 2008
  • Sludge conditioning is widely used to improve aggregation and dewaterability of waste sludge in sludge treatment processes. The study aims to examine quantitative correlations between coagulant dosage and sludge cake dewaterability using three kinds of coagulants, such as an aluminum sulfate, a ferric chloride, and a poly aluminum chloride(PAC). When an aluminum sulfate, a ferric chloride, and a PAC were injected with 0.79$\sim$1.19 mmol/g, 0.61$\sim$1.25 mmol/g TSS, and 0.21$\sim$0.39 mmol/g TSS, respectively, specific resistances to filtration of the sludge were decreased at 95.0% or more. This study shows that the correlation between coagulant dosage per g sludge(D) and normalized specific resistance to filtration(R) could be expressed by the exponential functions.

The Effect of the Fiber Volume Fraction Non-uniformity and Resin Rich Layer on the Rib Stiffness Behavior of Composite Lattice Structures (섬유체적비 불균일 및 수지응집층이 복합재 격자 구조체 리브의 강성도 거동에 미치는 영향)

  • Kang, Min-Song;Jeon, Min-Hyeok;Kim, In-Gul;Kim, Mun-Guk;Go, Eun-Su;Lee, Sang-Woo
    • Composites Research
    • /
    • v.31 no.4
    • /
    • pp.161-170
    • /
    • 2018
  • Cylindrical composite lattice structures are manufactured by filament winding process. The fiber volume fraction non-uniformity and resin rich layers that can occur in the manufacturing process affect the stiffness and strength of the structure. Through the cross-section examination of the hoop and helical ribs, which are major elements of the composite lattice structure, we observed the fiber volume fraction non-uniformity and resin rich layers. Based on the results of the cross-section examination, the stiffness of the ribs was analyzed through the experimental and theoretical approaches. The results show that the fiber volume fraction non-uniformity and resin rich layers have an obvious influence on the rib stiffness of composite lattice structure.

Application of electro-coagulation for the pretreatment of membrane separation of anaerobic digestion effluents (혐기성 소화액의 막분리를 위한 전기응집 전처리 연구)

  • Kim, Shin-Young;Chang, In-Soung;Kim, Jang-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4665-4674
    • /
    • 2014
  • The aim of this study was to confirm the feasibility of the electro-coagulation process as a pre-treatment for the membrane separation of anaerobic digestion effluents to minimize membrane fouling. The reduction of membrane fouling was evaluated according to the number of electrodes (immersed surface area of electrodes), current density and contact time. In the case of the small surface area of electrodes, the increased electric field strength resulted in a soluble COD increase due to the destruction of the microbial flocs and/or cells, whereas large changes in the soluble COD were not observed in the case of the high surface area of electrodes. On the other hand, the T-P concentration decreased as a result of the precipitation of aluminum ions and phosphates. The membrane permeation flux increased and the fouling resistance (Rc+Rf) decreased with increasing electric current density. Although the particle size of the anaerobic digestion effluent increased slightly, it was not related directly to the reduced fouling phenomena. The main mechanism for the enhanced flux was attributed to the inorganic particulate produced during electrocoagulation, such as $AlPO_4$, which acted as a dynamic membrane deposited on the membrane surface.