• Title/Summary/Keyword: 응력회복

Search Result 176, Processing Time 0.02 seconds

Photoelastic Stress Analysis of Single Implant Restoration According to Implant Fixture Size and Abutment Diameter (단일치 임플란트에서 고정체와 지대주 직경의 차이에 따른 광탄성 응력 분석)

  • Lee, Jin-Han;Cho, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.253-267
    • /
    • 2008
  • The purpose of this study was to evaluate the pattern and the magnitude of stress distribution in the supporting tissues surrounding implant fixture with different diameter of implant fixtures(3i implant, Ø4.0, Ø5.0, Ø6.0mm and UCLA abutments(Ø4.1, Ø5.0, Ø6.0mm using photoelastic stress analysis. Photoelastic model was made with PL-2 resin(Measurements Group, Raleigh, USA) and three implants of each diameter were placed in the mandibular posterior edentulous area distal to the canine. Individual crowns were fabricated using UCLA abutments. Photoelastic stress analysis was carried out to measure the fringe order around the implant supporting structure under simulated loading conditions(15 lb, 30 lb). The results were as follows; 1. The more the diameter of implant fixture was increased, the less the stress concentration on cervical area of fixture was observed under loading. 2. Increasing mesiodistal diameter of implant superstructure had no much influence on stress distribution around implant fixture. 3. The use of smaller abutment had no influence on stress distribution around implant fixture. The use of smaller abutment diameter than that of implant fixture had no favorable effect on implant supporting tissue at biomechanical consideration.

Buckling Analysis of Box-typed Structures using Adaptive Shell Finite Elements (적응적 쉘유한요소를 이용한 박스형 구조물의 좌굴해석)

  • Song, Myung-Kwan;Kim, Sun-Hoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.3
    • /
    • pp.265-272
    • /
    • 2007
  • The finite element linear buckling analysis of folded plate structures using adaptive h-refinement methods is presented in this paper. The variable-node flat shell element used in this study possesses the drilling D.O.F. which, in addition to improvement of the element behavior, permits an easy connection to other elements with six degrees of freedom per node. The Box-typed structures can be analyzed using these developed flat shell elements. By introducing the variable-node elements some difficulties associated with connecting the different layer patterns, which are common in the adaptive h-refinement on quadrilateral mesh, can be overcome. To obtain better stress field for the error estimation, the super-convergent patch recovery is used. The convergent buckling modes and the critical loads associated with these modes can be obtained.

Implant assisted obturator in patient after maxillectomy: a case report (상악골 절제 환자에서 임플란트를 이용한 구개폐쇄장치 증례)

  • Seo, Yoon-Hee;Lee, Joon-Seok;Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.322-329
    • /
    • 2016
  • Reconstruction of the maxillectomy with an obturator is to restore masticatory, swallowing, phonetic and esthetic problems. Stress created by lateral forces is minimized by the proper selection of an occlusal scheme, elimination of premature occlusal contacts, and wide distribution of supporting area. It should be considered that properly designed retainers reduce the stresses transmitted to the abutment while the obturator is in function. The following clinical report presents palatal obturator treatment with implant assisted removable partial denture (IARPD) design that restores normal function and esthetics in patients who experienced maxillectomy and dental implant failure.

Development of Permanent Deformation Prediction Model for Trackbed Foundation Materials based on Shear Strength Parameters (강화노반 쇄석재료의 전단강도특성을 고려한 영구변형예측모델 개발)

  • Lim, Yujin;Hwang, Jungkyu;Cho, Hojin
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.6
    • /
    • pp.623-630
    • /
    • 2012
  • Formation used as trackbed foundation for providing vertical bearing capacity onto rail foundation are composed of crushed stones usually with certain type of grain size distribution. Permanent deformation in trackbed foundation can be generated by increasing number of load repetition due to train traffic increases, causing track irregularity. In this study, a specially prepared trackbed foundation materials (M-40) used in Korea has been tested using a large repetitive triaxial compression apparatus in order to understand resilient and permanent deformation characteristics of the material. From these test results, resilient and permanent deformation characteristic are analyzed so that a permanent deformation model is developed which can consider number of load repetition N, confining stress (${\sigma}_3$), shear stress ratio(${\tau}/{\tau}_f$) and stiffness of the material.

Characterization of the Stress in the Luting Cement layer Influenced by Material Properties of Full Veneer Crown (전부피개관의 물성과 시멘트의 물성이 시멘트 내부의 응력에 미치는 영향)

  • Lee, Jun-Young;Lee, Kyu-bok;Lee, Chung-Hee;Jo, Kwang-Hun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.1-12
    • /
    • 2009
  • The objective of this study was to test the effects of crown material, cement type, the direction in which stress is applied and distribution of luting cement that might lead to cement microfracture using 2D Finite Element Method. Twenty three finite element models with a chamfer margin configuration were generated for a mandibular first molar. Crown models exhibited four crown materials: type 3 gold alloy, Ni-Cr alloy, ceramic and composite resin, and two luting cements: zinc phosphate and glass ionomer cements with a thicknesses of $70{\mu}m$. Modeled crowns were loaded axially or obliquely at unit load of 1 N. Areas and levels of stress concentrations within the cement were determined. Stress in the cement layer at the margins of crowns were higher than those in the area away from the margin. Stress under oblique loads were much higher than under axial load. The stiffer crown material produced higher stress and similarly, higher stress were found in cements with the greater Young's modulus.

A photoelastic Stress Analysis of Implant Prosthesis According to Fitness of Super structure (불량 적합 임플란트 보철물의 광탄성 응력 분석)

  • Lim, Hyun-Pil;Heo, Shin-Ok;Kim, Hong-Joo;Park, Sang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.39-46
    • /
    • 2010
  • To assess the stress distribution of implant prosthesis induced by intentional misfit using photoelastic model. Stress was measured at the surrounding bone after applying vertical load to the implant. Three implants were placed in each of three photoelastic resin blocks. No misfits were used for the control group, while for the experimental group $100{\mu}m$ misfit after cutting the crown was used. The photoelastic stress analysis was performed. In control group, stress concentration was not shown when the load was not applied, whereas stress concentration was shown only in the loaded part even when load was applied and the stress was distributed in anterior-posterior direction when applying a load in the middle. When intentional misfits were given, stress around the fixture was incurred when tightening the screw even if load was not applied. If the load was applied, stress was concentrated around the implants including areas where the load was applied. In particular, the prosthesis made of UCLA showed more stress concentration as compared with a conical abutment. In the UCLA case, concentration was shown from the apex following through the axis to the cervical area. Prosthesis with misfit makes the stress concentrated though the load was not applied and it induces even more severe stress concentration when the load was applied. This founding demonstrates the importance of the correct prosthesis production.

Arthroscopic Reduction of Subluxed Medial Meniscus using Suture Anchor for Restoration of Hoop Stress - Technical Note - (버팀테응력 회복을 위한 아탈구된 내측 반월상 연골의 Suture anchor를 이용한 정복술 - 술기 보고 -)

  • Kim, Jaw-Hwa;Lee, Yoon-Seok;Kim, Chul;Han, Seung-Chul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.3
    • /
    • pp.280-284
    • /
    • 2009
  • Purpose: The authors introduce a new technique of arthroscopic reduction of subluxed medial meniscus using suture anchor for the restoration of hoop stress. Operative Technique: Anterolateral, anteromedial, and medial midpatellar arthroscopic portal are used. Arthroscope was inserted through anterolateral portal. Through the scope, we confirmed subluxation of medial meniscus. Transection of menisci including radial and root tear were excluded. We released the anterior horn of medial meniscus through anteromedial and burred the future insertion site of suture anchor. After inserting suture anchor through medial midpatellar portal, we used 90 degree suture hook and no.2 Nylon to retrieve the suture of inserted anchor. We tied the suture by sliding knot-tying method. Weight bearing was limited for 6 weeks postoperatively. Conclusion: Arthroscopic retightening of medial meniscus is less invasive, conserving and progressed method for subluxed meniscus.

  • PDF

Study on the Recovery and Recrystalligation of Cold-lolled Zr-based Alloys by Thermoelectric Power Measurement During Isothermal Annealing (TEP 분석을 이용한 냉간가공된 Zr-based 합금의 등온열처리에 따른 회복 및 재결정 거동에 관한 연구)

  • O, Yeong-Min;Jeong, Heung-Sik;Kim, Seon-Jin
    • Korean Journal of Materials Research
    • /
    • v.11 no.6
    • /
    • pp.483-491
    • /
    • 2001
  • The recovery and recrystallization behavior of cold-rolled Zr-based alloys during isothermal annealing at temperatures from $575^{\circ}C$ to $650^{\circ}C$ was studied by thermoelectric power and Vickers microhardness measurement. The recovery and recrystallization resulted in the increase of TEP doe to the extinction of lattice defect, vacancy, dislocation and stacking fault during isothermal annealing after cold- rolling. The completion of recrystallization could be determined much clearly by TEP behavior than by microhardness change in Zr-based alloys. Especially, the recovery and recrystallization were classified separately by TEP behavior in Zr-0.4Nb-xSn alloys. From the analysis of TEP behavior and microhardness, the addition of Sn caused to form the interaction between stain field and dislocation, which resulted in the delay of recovery in Zr-based alloys. The precipitation due the addition of Nb suppressed the grain growth after recrystallization effectively in Zr-based alloys.

  • PDF

Pop-in/pop-out Phenomena in Materials under the Contact Stress during Nanoindentation (나노인덴테이션 접촉응력 하에서의 재료의 팝인/팝아웃 현상)

  • 김지수;고철호;윤종성;윤존도
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.40-40
    • /
    • 2003
  • 최근 나노기술의 발달과 더불어 나노재료에 대한 특성평가 요구가 높아지고 있고, 따라서 나노스케일에서 재료의 기계적 거동을 분석할 수 있는 나노인덴테이션 기법이 심도있게 연구되고 있다. 본 연구에서는 나노인덴테이션, 주사탐침현미경(SPM), 투과전자현미경(TEM) 기법을 이용하여 여러가지 재료의 탄성 소성 변형 거동과 팝인/괍아웃 현상을 조사하고 해석하였다. 나노인덴테이션 기법으로는 50 마이크로뉴턴 (5 mg) 이하의 매우 작은 하중 하에서는 접촉 응력조건이라도 인장시험에서 관찰되는 영구변형이 제로인 완전탄성 변형 거동을 관찰할 수 있었다. 또한, 50-250 마이크로 뉴턴의 하중 범위에서 재료는 탄성변형 이후에 갑작스런 항복거동과 더불어 수십-수백 나노미터를 미끌어지듯 변형하는 팝인(pop-in), 또는 탈선(excursion) 현상을 관찰할 수 있었다. 이 현상은 하중을 가하는 동안에 여러 번 발생하였으며 재료의 표면상태와 전위밀도와 밀접한 상관관계를 보였다. 반복 압입 시험에서는 전형적인 가공경화 현상으로 항복점이 높아지고 새로운 항복점 이후에야 다시 팝인 발생함을 보였다. 한편, 하중을 가할 때 발생하는 팝인과는 달리 하중을 제거할 때 급격히 회복하는 팝아웃 현상 또한 관찰되었다.

  • PDF

Elastic-plastic Contact Stress Analysis of CRT Glass Bulb (CRT 글래스 벌브의 탄소성 접촉 응력 해석)

  • Kang, Dae Jin;Shin, Woon Seo;Song, Chang Seop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.2
    • /
    • pp.145-151
    • /
    • 1997
  • In this paper, we discuss the cathode ray tube(CRT) glass bulb stress and sagging recovery by the contact band pressure using finite element method. We analyzed the band pressure and stress using contact element method between band and bulb before and after banding process which was conducted to decrease the stress concentration using finite element method, and calculated sagging recovery. The analysis results were confirmed by experiments using strain gauge and sagging recovery test apparatus.

  • PDF