• Title/Summary/Keyword: 음향학적 검사

Search Result 40, Processing Time 0.027 seconds

Voice Analysis of Countertenors (카운터테너의 음성학적 분석)

  • 정성민;김문정;윤선옥;신혜정;박수경;신유리;권영경
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.12 no.1
    • /
    • pp.39-45
    • /
    • 2001
  • Background and Objectives : A post-pubescent male classical singer has lower vocal register than a female classical singer. Countertenors who can produce higher vocal register like female classical singers with their falsetto voice and head resonance are recently active. The general purpose of this study is to analyze voice of countertenors and to determine the differences with those of classical singers. Materials and Methods : Four countertenors in Korea were examined using a videostrobos-copy and their voice were analyzed using aerodynamic, acoustic and voice range profile methods. Results and Conclusion : Countertenors could produce elevated fundamental frequency, voice intensity and mean air flow rate using large pulmonary capacity and head voiced falsetto. It means the presence of greater energy in countertenor is due to the more efficient conversion of the air flow to acoustic energy. But, they had unstable amplitude perturbation per each vocal cycle. The results indicated that countertenor is the acoustic products of different laryngeal mechanism with other classical register and it can be recognized as one of the registers of male classical singers.

  • PDF

Treatment Outcomes and Acoustic Rhinometric Results in Endoscopic Sinus Surgery of Adult Chronic Paranasal Sinusitis (성인 말성 부비동염에서 내시경적 부비동 수술 전.후의 증상 호전도와 음향비강통기도 검사 결과)

  • Kim, Yong-Dae;Kim, Jae-Yeul;Chang, Keun-Young;Lee, Hyung-Joong;Song, Si-Youn;Yoon, Seok-Keun
    • Journal of Yeungnam Medical Science
    • /
    • v.19 no.1
    • /
    • pp.28-38
    • /
    • 2002
  • Background: Chronic paranasal sinusitis is one of the most common disease in the otorhinolaryngologic field. Endoscopic sinus surgery is treatment of choice in chronic paranasal sinusitis. The aim of this study was to evaluate objective and subjective treatment outcomes of endoscopic sinus surgery in adult chronic paranasal sinusitis with or without polyp. Materials and Methods: We reviewed 84 adult patients underwent endoscopic sinus surgery by one surgeon from June 1999 to June 2000, prospectively. We analyzed preoperative and postoperative subjective symptom scores and acoustic rhinometric results. Results: Fifty cases were male and thirty four cases female. The average age was of 33 year-old (range: 17 to 66 years). There was significantly improvement of symptom scores in postoperative 3 months and 6 months compared with preoperative symptom scores. There was significantly increased postoperative total volume of nasal cavity. When we compared high score group with low score group, there was statistically significant improvement of symptom scores between preoperative stage and postoperative 3 months in radiologic grading group. Conclusions: Endoscopic sinus surgery is considered to be effective for the treatment of chronic paranasal sinusitis. It seems to be helpful to employ subjective symptom score system and objective total volume change of nasal cavity through acoustic rhinometric test to analyze effectiveness of endoscopic sinus surgery. In this study, the most important preoperative factor of sinus surgery outcomes is radiologic grading system.

  • PDF

The Acoustic and Aerodynamic Aspects of Patients with Spasmodic Dysphonia (연축성 발성장애 환자의 음향학적 및 공기역학적 양상)

  • 이주환;김인섭;고윤우;오종석;배정호;윤현철;최성희;최홍식
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.11 no.1
    • /
    • pp.98-103
    • /
    • 2000
  • Background and Objectives : The etiology and pathophysiology of spasmodic dysphonia is yet unknown. This study was performed to determine if any laryngeal aerodynamic parameter distinguish the voice of patient diagnosed as having adductor spasmodic dysphonia from individuals with normal voice production and to investigate the pathophysiology of spasmodic dysphonia. Materials and Methods : fifteen women diagnosed as having adductor spasmodic dysphonia and fifteen normal control women participitated in this study Maximum phonation time, mean air flow rate, subglottic pressure, vocal efficiency, Vfo, NHR, VTI, FTRI, ATRI, Jitter percent, Shimmer percent were obtained from the participants using 'MDVP(multi-dimensional voice program)' of CSL(Computerized Speech lab, Kay Elemetrics, Co., Model No. 4300), and 'maximum sustained phonation' and 'IPIPI test' of AP II(Aerophone II, Kay Elemetrics, Co., Model 6800). Results : T-test statistical analysis revealed statistically different values for vocal efficiency, Vfo, NHR, MPT, litter percent, Shimmer percent between the spasmodic dysphonia group and the control group. Conclusions : Spasmodic dysphonia affects the ability of the laryngeal mechanism to function effectively. Results from our study demonstrate that certain aerodynamic and acoustic parameters distinguish adductor spasmodic dysphonia from normal voice.

  • PDF

A preliminary study of sound quality evaluation of cochlear implant users (인공와우 사용자의 심리음향적 음질평가 예비연구)

  • Bahng, Junghwa;Oh, Soo Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.1
    • /
    • pp.45-51
    • /
    • 2022
  • Sound quality evaluation is one of the psychoacoustic methods to measure subjective judgements for sound color. The purpose of this study is to investigate sound quality benefits of bimodal users by comparing sound quality scores between bimodal hearing condition and unilateral cochlear implant(CI) condition as a preliminary study. Thirteen bimodal users and seven unilateral CI users were participated in this study. Audiologists performed pure tone and speech audiometry and measured functional gain and real-ear insertion gain. Subjective assessment of sound quality was followed with four sounds including violin sound, male and female voices, and refrigerator noise. Participants judged the sound quality with six sound quality index. Bimodal users showed mean 0.8 points more sound quality improvements in bimodal condition than unilateral CI condition. Group comparison between bimodal and unilateral CI users showed no differences. A follow-up study of sound quality tools and methods should be considered to evaluate subjective bimodal benefits of cochlear implant users.

VHI, V-RQOL, and vocal characteristics of teacher and singer (교사 및 성악가의 VHI, V-RQOL, 음향학적 특성 비교)

  • Hong, Ju-Hye;Hwang, Young-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.7
    • /
    • pp.3048-3056
    • /
    • 2012
  • The purpose of this study was to investigate VHI, V-RQOL, and vocal characteristics of a teacher and singer. 56 subjects were participated in this study (20 subjects are a teacher with vocal nodule, 20 subjects are a singer with vocal nodule, and 16 subjects are normal speakers). All subjects completed the VHI, V-RQOL, and vocal characteristics were measured using CSL 4500(Kay Pentax. USA). 21 subjects completed the VHI, V-RQOL, and vocal evaluation using CSL 4500 twice to assess test-retest reliability. A statistical analysis was performed using the Statistical Package for Social Sciences 18.0 (SPSS Inc, Chicago, IL). The VHI and V-RQOL showed that the teacher and singer group were significantly higher than those of the control group in functional, physical and emotional aspects(p<0.05). the acoustic analysis using CSL 4500 showed the teacher and singer group were significantly higher than those of the the control group in fundamental frequency related variables, fundamental perturbation related variables, amplitude perturbation related variables, noise related variable, and tremor related variables(p<0.05). Conclusionally, the teacher and singer group recognized their voice problems as a serious physico-functional aspects.

Piezoelectric Polymer Ultrasound Transducers and Its Biomedical Applications (압전고분자 초음파 트랜스듀서와 생의학적 응용)

  • Ha, Kang-Lyeol;Cao, Yonggang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.585-596
    • /
    • 2012
  • PVDF(poly vinylidene fluoride) and P(VDF-TrFE)(poly vinylidene fluoride-tetrafluoroethylene) are the typical piezoelectric polymers with unique properties. Even they are inferior to conventional piezoelectric ceramics PZT in electromechanical conversion efficiency and interior loss, though they are superior in receiving sensitivity and frequency bandwidth. Their acoustic impedances are relatively close to water or biological tissue and it is easier to make thin film than other piezoelectric materials. Futhermore, the film is so flexible that it is easy to attach on a complex surface. Those properties are suitable for the ultrasound transducers which are useful for medical and biological application, so that various types of polymer transducers have been developed. In this paper, several important considerations for design and fabrication of piezoelectric polymer transducers were described and their effect on the transducer performance were demonstrated through the KLM model analysis. Then, it was briefly reviewed about the structures of the polymer transducers developed for obtaining images as well as the characteristics of the images in several important medical and biological application fields.

Detection of Fatigue Damage in Aluminum Thin Plates with Rivet Holes by Acoustic Emission (리벳 구멍을 가진 알루미늄 박판구조의 피로손상 탐지를 위한 음향방출의 활용)

  • Kim, Jung-Chan;Kim, Sung-Jin;Kwon, Oh-Yang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.3
    • /
    • pp.246-253
    • /
    • 2003
  • The initiation and growth of short fatigue cracks in the simulated aircraft structure with a series of rivet holes was detected by acoustic emission (AE). The location and the size of short tracks were determined by AE source location techniques and the measurement with traveling microscope. AE events increased intermittently with the initiation and growth of short cracks to form a stepwise increment curve of cumulative AE events. For the precise determination of AE source locations, a region-of-interest (ROI) was set around the rivet holes based on the plastic zone size in fracture mechanics. Since the signal-to-noise ratio (SNR) was very low at this early stage of fatigue cracks, the accuracy of source location was also enhanced by the wavelet transform do-noising. In practice, the majority of AE signals detected within the ROI appeared to be noise from various origins. The results showed that the effort of structural geometry and SNR should be closely taken into consideration for the accurate evaluation of fatigue damage in the structure.

Characteristics of Vowel Formants, Voice Intensity, and Fundamental Frequency of Female with Amyotrophic Lateral Sclerosis using Spectrograms (스펙트로그램을 이용한 근위축성측삭경화증 여성 화자의 모음 포먼트, 음성강도, 기본주파수의 변화)

  • Byeon, Haewon
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.9
    • /
    • pp.193-198
    • /
    • 2019
  • This study analyzed the changes of vowel formant, voice intensity, and fundamental frequency of vowels for 11 months using acoustochemical spectrogram analysis of women diagnosed with amyotrophic lateral sclerosis (ALS). The test word was a vowel /a, i, u/ and a diphthong /h + ja + da/, /h + wi + da/, and /h +ɰi+ da/. Speech data were collected through the word reading task presented on the monitor using 'Alvin' program, and the recording environment was set to 5,500 Hz for the nyquist frequency and 11,000 Hz for the sampling rate. The records were analyzed by using spectrograms to vowel formants, voice intensity, and fundamental frequency. As a result of analysis, the fundamental frequency and intensity of the ALS process were decreased and the formant slope of the diphthong was decreased rather than the formant change in the vowel. This result suggests that the vowel distortion of ALS due to disease progression is due to the decrease of tongue and jaw co morbidity.

A comparison of acoustic measures among the microphone types for smartphone recordings in normal adults (정상 성인에서 스마트폰 녹음을 위한 마이크 유형 간 음향학적 측정치 비교)

  • Jeong In Park;Seung Jin Lee
    • Phonetics and Speech Sciences
    • /
    • v.16 no.2
    • /
    • pp.49-58
    • /
    • 2024
  • This study aimed to compare the acoustic measurements of speech samples recorded from individuals with normal voices using various devices: the Computerized Speech Lab (CSL), a unidirectional wired pin-microphone (WIRED) suitable for smartphones, the built-in omnidirectional microphone (SMART) of smartphones, and Bluetooth-connected wireless earphones, specifically the Galaxy Buds2 Pro (WIRELESS). This study included 40 normal adults (12 males and 28 females) who had not visited an otolaryngologist for respiratory diseases within the past three months. Participants performed sustained vowel /a/ phonation for four seconds and reading tasks with sentences ("Walk") and paragraphs ("Autumn") in a sound-treated booth. Recordings were simultaneously conducted using the four different devices and synchronized based on the CSL-recorded samples for analysis using the MDVP, ADSV, and VOXplot programs. Compared with CSL, the Cepstral Spectral Index of Dysphonia (CSIDV, CSIDS) and Acoustic Voice Quality Index (AVQI) values were lower in the WIRED and higher in the SMART. The opposite trend was observed for the L/H spectral ratios (SRV and SRS), and the WIRELESS demonstrated task-specific discrepancies. Furthermore, both the fundamental frequency (F0) and the cepstral peak prominence of the vowel samples (CPPV) had intraclass correlation coefficient (ICC) values above 0.9, indicating high reliability. These variables, F0 and CPPV were considered highly reliable for voice recordings across different microphone types. However, caution should be exercised when analyzing and interpreting variables such as the SR, CSID, and AVQI, which may be influenced by the type of microphone used.