• Title/Summary/Keyword: 음파효과

Search Result 123, Processing Time 0.03 seconds

A Study for Reducing the Acoustic Cross Talk Level in an Array Type Piezoelectric Ultrasonic Transducer Using Acoustic Wells (음향 벽을 이용한 배열형 압전형 초음파 변환기의 음향 간섭 수준 감소를 위한 연구)

  • 김영신;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.208-216
    • /
    • 2003
  • In one dimensional linear array type piezoelectric ultrasonic transducers widely used for medical diagnosis, the acoustic cross talk caused by the structural acoustic coupling between the adjacent piezoelectric elements reduces significantly their performance. In the study, we have proposed an acoustic wall to reduce the acoustic cross talk by wave propagation through the surface the transducer which can not be prevented by conventional kerf and have analyzed using a finite element method the acoustic cross talk level with respect to the shape, size and materials of the acoustic wall mounted on a convex one dimensional piezoelectric ultrasonic transducer. We expect that the simulated results provide us with a valuable information to make an optimized design of the way type ultrasonic transducer minimizing the acoustic cross talk level.

A Study on The low-frequency Hydrophone Using Single-mode FBG in the Hopper Type WDM be in the Making (단일모드 FBG(Fiber Bragg Grating)을 이용한 Hopper type WDM 개발과 저주파수 수중음향 센서연구)

  • Kim, Kyung Bok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.287-291
    • /
    • 2013
  • The low- frequency hydrophone sensor, using the recently developed FBG has an excellent merits which the existing fiber-optic sensor has and also it has an excellent signal sensing effect in the environment of low-frequency(30Hz-300Hz), not to be detected by the PZT sensor. we have the detection of frequency 19KHz right signals when was using more Hopper lenz WDM than $1{\times}3$ optical coupler. furthermore, we can expect the uitilization of low-frequency signal detection to be used for the military purpose and also it can be developed as the high-sensibility multiplexing through the sensor array system.

A Study on Recycle of Concreted Organic Waste water by Electroflotation Apparatus for Resource Recycle of Non-Metal (비금속 자원 재활용을 위한 전해부상 장치를 이용한 고농도 유기질 폐수의 재활용에 관한 연구)

  • Kim, Ki-Jun;Nam, Sang-Sung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.653-658
    • /
    • 2012
  • There is an increasing interest in the use of electrochemical methods for the food waste treatment. The technologies using the electrochemical method provide ideal tools for approaching industrial and food wastes problems. Unlike other chemical treatments, the electrochemical systems do not make the volume of the secondary waste increase. The electrochemical methods can be operated with electrochemical apparatus and inorganic agent allow selective separation and recovery and even quieter than others. This study concerns design factors, electrode construction and wastewater treatment process of the electrochemical apparatus. The experiment of color, COD and BOD removal is much effective in using electrochemical method with ultrasonication and ozonation.

Transdermal permeation and Anti-inflammatory Effects of Piroxicam Gel by Phonophoresis (음프록시캄 겔을 이용한 음파영동이 경피투과와 염증에 미치는 효과)

  • Choi, Sug-Ju;Kim, Tae-Youl;Yoon, Se-Won
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.1
    • /
    • pp.170-179
    • /
    • 2003
  • This study was performed that how phonophoresis using ultrasound for piroxicam affects transdermal permeation and anti-inflammative effects. Transdermal permeation study conducted by using hairless mouse had two categories: control group and ultrasound group. Transdermal permeation was observed according to duty cycle and intensity. Anti-inflammatory effects were determined using in Sprague-Dawley rat. The subjects were divided into three groups of six SD rat each 24 hour, 48 hour, 72 hour. The results of this study were as follows: 1. Transdermal permeation of piroxicam was measured according to ultrasound duty cycle. This research demonstrates that ultrasound group retains more transdermal permeation than control group, and that pulsed ultrasound group holds a little more transdermal permeation than continuous ultrasound group. 2. The transdermal permeation of piroxicam is closely related with ultrasound intensity. Effect of each group of transdermal permeation was significant rises in proportion to ultrasound intensity. 3. By observing inflammation of the tissue caused by trauma, phonophoresis group showed more significant of anti-inflammatory effect. The conclusion of phonophoresis was found to improve significantly the transdermal permeation and the anti-inflammatory effect.

  • PDF

Media Access Control Mechanism for Efficient Wireless Communication in Underwater Environments (수중 환경에서 효율적인 무선 통신을 위한 매체접근제어 메커니즘)

  • Jeong, Yoo-Jin;Shin, Soo-Young;Park, Soo-Hyun
    • Journal of the Korea Society for Simulation
    • /
    • v.15 no.4
    • /
    • pp.79-86
    • /
    • 2006
  • Data transmission in poor environment like underwater has considerably serious delay rate and ewer rate. Like this environment usually has heavy fluctuation of error rate and limited wireless communication state. Therefore, mechanism using in such environment has to be efficient and simple. This paper suggests a new block ack mechanism, called the Pervasive Block ACK (PBA), which transmits aggregated ACKs. This mechanism takes effect on reducing number of traffic, decreasing overhead and delay rate in poor environment networks like underwater. Additionally, we can expect energy consumption. We verify propriety and efficiency of PBA through describing numerical result based analytical formula in this paper.

  • PDF

Measurements of High-frequency Sea Surface Backscattering Signals (고주파 해수면 후방산란 신호 측정)

  • 최지웅;나정열;박경주;윤관섭;박정수;나영남
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.4
    • /
    • pp.421-429
    • /
    • 2002
  • Sea surface backscattering signal measurements were conducted in the shallow waters off the east coast of Korea to study the acoustic wave scattering from the sea surface. The grazing angles of wave range from 20° to 40° with a frequency of 60 kHz. The wind speed and surface roughness of the experiment area were 3 m/os and below 1 m, respectively. The measured acoustic backscattering strengths greatly exceed the composite roughness predictions at low grazing angles. To account for this discrepancy, the scattering strengths due to a near-surface bubble layer were considered. The prediction with bubble contribution was found to be in good agreement with the experimental measurement.

Remote Sound Extraction Using Laser Doppler Interferometer (레이저 도플러 간섭계를 이용한 원거리 소리 추출)

  • Hwang, Jeong-hwan
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.3
    • /
    • pp.108-113
    • /
    • 2021
  • We propose and experimentally demonstrate a method of remote sound extraction using laser Doppler interferometry. The output frequency of a laser Doppler interferometer changes to be the same as the frequency of the acoustic wave from than object vibrated by the sound due to the Doppler effect. Based on this phenomenon, we measure the vibrational frequency of a remote target affected by a sound wave in real time, via laser Doppler interferometry. We track the peak frequency of the interferometer's output via appropriate signal processing, which confirms that the characteristics of the so detected wave are the same as that of the original sound source. We also confirm that the same method can retrieve the sound waves not only from remote sources of single tones, but from those of any sound.

5-MHz Volume Backscattering Strength Measurements from Suspended Sediment Concentrations (5 MHz 신호를 이용한 부유물의 농도에 따른 후방산란강도 측정)

  • Lee, Changil;Choi, Jee Woong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.14-21
    • /
    • 2013
  • The erosion, suspension, and transport of sediment frequently occur in the coastal waters and estuarine. These processes often generate the so-called fluid mud layer, which is defined as a high-concentration aqueous suspension of fine grained sediment (> 10 g/l), consisting mainly of silt and clay-size particles. Therefore the high-resolution ultrasound is mostly used to detect or monitor the fluid mud layer. Because the sound attenuation tends to increase rapidly with the suspended sediment concentration, it is necessary to consider the accurate attenuation correction to estimate the backscattering strengths from the suspended sediment layers. In this paper, the volume backscattering strengths with various suspended sediment concentrations were measured using 5-MHz ultrasound signal in a small-scale water tank. The sound attenuation due to the viscosity and scattering from suspended sediment particles was predicted by the Richard's model and applied to the sonar equation to estimate the volume backscattering strengths from the suspended sediment concentrations. For the case that the additional attenuation was not considered, the volume backscattering strengths increased to the concentration of 20 g/l, and over this point, the backscattering strengths were roughly constant. However, for the case that the attenuation due to the suspended sediment concentration was considered, the backscattering strengths increased with the concentration.

Causes and Clinical Outcomes of Congenital Hydronephrosis (신생아 수신증의 원인과 임상 경과에 대한 고찰)

  • Kang Hyun-Young;Chang Mea-Young;Lee Jae-Ho
    • Childhood Kidney Diseases
    • /
    • v.9 no.1
    • /
    • pp.69-75
    • /
    • 2005
  • Purpose : The most important management of congenital hydronephrosis consists of the early diagnosis and evaluation of the pathologic abnormalities of congenital hydronephrosis. This study was conducted to investigate the different causes of hydronephrosis and its clinical outcome. Methods : 54 live neonates who were hospitalized and diagnosed with congenital hydronephrosis at Chungnam National University Hospital from Aug. 1998 to Aug. 2003 were retrospectively analyzed. Results : Hydronephrosis(renal pelvic AP diameter $gt;5 mm) was postnatally detected in 54 cases(2.1%) among 2,539 neonates who were hospitalized from Aug. 1998 to Aug. 2003. There were three times more males than females. Additional imaging studies revealed that ureteropelvic junction obstruction was the most common postnatal diagnosis(48.7%), followed by multicystic dysplastic kidney, vesicoureteral reflux and duplication kidney with ureterocele. Spontaneous regression of hydronephrosis was revealed in 25 renal units(75.8% ) of mild hydronephrosis, 14 renal units of moderate hydronephrosis and 1 renal unit of severe hydronephrosis. Operative correction were carried out in 14 renal units(70%) of severe hydronephrosls. Conclusion : The most common established cause of congenital hydronephrosis in this study was ureteropelvic junction obstruction. There are many cases of spontaneous regression in mild to moderate congenital hydronephrosis. Urinary tract infections occur in many neonates with hydronephrosis. Therefore, early detection and evaluation of congenital hydronephrosis and continuous follow-up at regular intervals are necessary for conservation of renal function. (J Korean Soc Pediatr Nephrol 2005;9:69-75)

  • PDF

Physiological Activities using Root and Stem Extracts of Cymbidium (심비디움 뿌리 및 줄기 추출물의 생리 활성)

  • Kim, Hye-Ran;Park, Gyu-Nam;Jung, Bo-Kyoung;Shin, Yu-Su;Chang, Kyung-Soo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.4
    • /
    • pp.848-854
    • /
    • 2016
  • Cymbidium is one of perennial herbs belonging to the Orchidaceae and is known as a medicinal plant. However, its scientific data are insufficient. The purpose of this study is to extract from root and stem of Cymbidium, to investigate the biological effects of them. Cymbidium antibacterial effects of the extracts were performed by antibacterial test against Staphylococcus aureus (S. aureus), Staphylococcus saphrophyticus (S. saprophyticus), Proteus vulgaris (P. vulgaris) and Klebsiella pneumonia (K. pneumonia). Antioxidant effects of the extracts were carried out by DPPH radical scavenging. Total phenolic contents were also determined. Moreover, Cell viability of extracts against MTT assay was cell viability against HepG2 cell and also measures Cholesterol adsorptivity of extracts. In this study, the extracts inhibited the growth of bacteria. Particularly Cymbidium root extracts by only ethanol extraction showed highest antimicrobial effect against S. aureus. The Cymbidium stem extracts by both ethanol extraction and sonication for 1 hour had higher antioxidant activites as well as total phenolic contents. Cell cytotoxicity showed higher than $50{\mu}g/mL$. Cholesterol adsorptivity showed lower than 20%. These results suggest that the Cymbidium might be a source of anti-bacterials and anti-oxidants.