• Title/Summary/Keyword: 음의 자화값

Search Result 7, Processing Time 0.01 seconds

Magnetic Properties of Bismuth Substituted Terbium Iron Garnet (Tb3-xBixFe5O12(x=0.5, 0.75, 1.0, 1.25)의 자기적 특성 연구)

  • Park, Il-Jin;Kim, Chul-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.5
    • /
    • pp.245-248
    • /
    • 2006
  • [ $Tb_{3-x}Bi_xFe_5O_{12}$ ] has been studied by x-ray diffraction (XRD), vibrating sample magnetometer, $M\"{o}ssbauer$ spectroscopy. The crystal structures were found to be a cubic garnet structure with space group Ia3d. The lattice constants increase linearly with increasing bismuth concentration. With increase of bismuth substitution, the $N\'{e}el$ temperature increases but the compensation temperature decreases. We have observed the negative magnetization in Bi-TbIG system which has not been reported in garnet systems. $M\"{o}ssbauer$ spectra were measured at various temperatures from 4.2 K to $N\'{e}el$ temperature. The isomer shifts at room temperature are ${\sim}0.26mm/s$ which is consistent with ferric state.

Analysis of Giant Magnetoresistance Behavior of NiFeCo/Cu/NiFeCo/FeMn Valves (NiFeCo/Cu/NiFeCo/FeMn 스핀밸브 구조의 자기저항 거동 해석)

  • 배성태;김진영;민경익;신경호
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.2
    • /
    • pp.112-116
    • /
    • 1996
  • 스퍼터링법으로 제조한 NiFeCo/Cu/NiFeCo/FeMn 스핀밸브 자성 다층막의 자기적 성질과 자기저항에 대해 연구하였다. Cu 사잇층 두께가 15 .angs. 인 경우 약 6%의 자기저항을 얻을 수 있었다. NiFeCo/FeMn에서 교환이방성 자계는 약 20 Oe 정도였는데, 이는 NiFe/FeMn 계 스핀밸브 구조에서 보고된 값(100 Oe 이상) 보다 현저히 작은 것이다. 3 mTorr에서 제조한 NiFeCo 박막은 약 10 Oe 정도의 큰 보자력을 보임으로써 비슷한 조건에서 제조한 NiFe 박막의 경우(약 2 Oe)보다 상당히 큰 값을 갖는 것으로 관찰되었다. 작은 교환이방성 자계와 큰 보자력으로 인해 음 .rarw. 양 방향과 양 .rarw. 음 방향의 자화거동에 있어서 비대칭적인 자기저항 이력곡선 거동을 보이는 것으로 나타났다.

  • PDF

The Effect of Magnetic Field Annealing on the Structural and Electromagnetic Properties of Bising $Co_{82}Zr_6Mo_{12}$ Thin Films for Magnetoresistance Elements (자기저항소자의 바이어스용 $Co_{82}Zr_6Mo_{12}$ 박막의 구조 및 전자기적 특성에 미치는 자장 중 열처리의 영향)

  • 김용성;노재철;이경섭;서수정;김기출;송용진
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.2
    • /
    • pp.111-120
    • /
    • 1999
  • The effects of annealing in rotating magnetic field after deposition on electromagnetic properties of $Co_{82}Zr_6Mo_{12}$ thin (200~1200 $\AA$) films prepared by RF-magnetron sputtering were investigated in terms of microstructure and surface morphology. The coercivity decreases, but $4{\pi}M_5$ does not change with increasing the film thickness. The coercivity of the films was decreased below 300 $^{\circ}C$ due to stress relief and decreasing the surface roughness, while increased at 400 $^{\circ}C$ due to partial grain growth. And then, $4{\rho}M_5$ was almost independent of annealing temperatures below 200 $^{\circ}C$, but increased from 7.4 kG to 8.0 kG at 300 $^{\circ}C$ and at 400 $^{\circ}C$, which was caused by precipitation and growth of fine Co particles in the films. The electrical resistivity of films was decreased with increasing annealing temperatures and the magnetoresistance was a negative value of nearly 0 $\mu$$\Omega$cm. After annealing at 300 $^{\circ}C$, maximum effective permeability was 1200 to the hard axis of the thin films according to high frequency change. Considering the practical application of biasing layers of the films for magnetoresistive heads, optimal annealing conditions was obtained after one hour annealing at 300 $^{\circ}C$ in 400 Oe rotating magnetic field.

  • PDF

Magnetic Properties of CrO2 Thin Films Deposited by Thermal Deposition (열분해법으로 형성된 산화크롬 박막의 자기적 특성)

  • Choi, Hyun-Ju;Lim, Dae-Soon;Lee, Jeon-Kook
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.9
    • /
    • pp.653-656
    • /
    • 2004
  • We report the magnetic properties, microstructures, and crystal orientations of the CrO$_2$ thin films on TiO$_2$ single crystals. CrO$_2$ thin films were deposited by thermal decompositions with CrO$_3$ source materials. The microstructure of (110) oriented CrO$_2$ thin films deposited on (110) TiO$_2$ single crystals were uniform. As the oxygen flow rates increased, the resistivity, coercive field, and remnant magnetization of the CrO$_2$ thin films on TiO$_2$ single crystals decreased.

A Study on Fuzziness Parameter Selection in Fuzzy Vector Quantization for High Quality Speech Synthesis (고음질의 음성합성을 위한 퍼지벡터양자화의 퍼지니스 파라메타선정에 관한 연구)

  • 이진이
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.8 no.2
    • /
    • pp.60-69
    • /
    • 1998
  • This paper proposes a speech synthesis method using Fuzzy VQ, and then study how to make choice of fuzziness value which optimizes (controls) the performance of FVQ in order to obtain the synthesized speech which is closer to the original speech. When FVQ is used to synthesize a speech, analysis stage generates membership function values which represents the degree to which an input speech pattern matches each speech patterns in codebook, and synthesis stage reproduces a synthesized speech, using membership function values which is obtained in analysis stage, fuzziness value, and fuzzy-c-means operation. By comparsion of the performance of the FVQ and VQ synthesizer with simmulation, we show that, although the FVQ codebook size is half of a VQ codebook size, the performance of FVQ is almost equal to that of VQ. This results imply that, when Fuzzy VQ is used to obtain the same performance with that of VQ in speech synthesis, we can reduce by half of memory size at a codebook storage. And then we have found that, for the optimized FVQ with maximum SQNR in synthesized speech, the fuzziness value should be small when the variance of analysis frame is relatively large, while fuzziness value should be large, when it is small. As a results of comparsion of the speeches synthesized by VQ and FVQ in their spectrogram of frequency domain, we have found that spectrum bands(formant frequency and pitch frequency) of FVQ synthesized speech are closer to the original speech than those using VQ.

  • PDF

Interpretation of the Magnetic Logs for a Finite Line of Magnetic Dipoles Model (유한 선형 자기쌍극자 모델에 대한 검층자료의 해석)

  • Kim, Jin Hu
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.2
    • /
    • pp.135-142
    • /
    • 1999
  • Interpretations of 3-component magnetic logging data obtained for a reinforced bar as a model of the line of the magnetic dipoles are conducted using a least squared inversion technique. The length of the bar is 1.12 m, sampling interval is 0.05 m, the distance between the bar and the borehole is 0.3 m, and the top of the bar is fixed at 0 m of depth. The bar is set to be approximately vertical. Magnetic anomalies smoothed with FFT are used as input data for the inversion. For the interpretation of magnetic logging data the depth to the top, the length, the magnetic moment per unit length, the direction of the magnetization (declination and inclination), and the bearing and plunge of the line of magnetic dipoles are left as unknown parameters. The comparison of the results obtained from the individual inversion of the horizontal component or the vertical component of the magnetic anomalies, and those from the simultaneous inversion of horizontal and vertical component of the magnetic anomalies shows that there exist some disagreements between each inversion result. The depth to the bottom of the bar, which is actually 1.12 m, is estimated as 1.18 m, and the inclination of the magnetization is estimated as -76°by simultaneous inversion. The negative value of the inclination indicates that the strength of the remnant magnetization is much greater than that of the induced magnetization, so that the direction of the resultant magnetization points to the top of the bar.

  • PDF

Investigation of the Correlation between Seoul Neuropsychological Screening Battery Scores and the Gray Matter Volume after Correction of Covariates of the Age, Gender, and Genotypes in Patients with AD and MCI (알츠하이머 치매 및 경도인지기능장애 환자에서 나이, 성별, 유전자형을 고려한 뇌 회백질 부피와 표준신경심리검사와의 상관관계 연구)

  • Lee, Seung-Yeon;Yoon, Soo-Young;Kim, Min-Ji;Rhee, Hak Young;Ryu, Chang-Woo;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.294-307
    • /
    • 2013
  • Purpose : To investigate the correlations between Seoul Neuropsychological Screening Battery (SNSB) scores and the gray matter volumes (GMV) in patients with Alzheimer's disease (AD) and mild cognitive impairment (MCI) and cognitively normal (CN) elderly subjects with correcting the genotypes. Materials and Methods: Total 75 subjects were enrolled with 25 subjects for each group. The apolipoprotein E (APOE) epsilon genotypes, SNSB scores, and the 3D T1-weighted images were obtained from all subjects. Correlations between SNSB scores and GMV were investigated with the multiple regression method for each subject group using both voxel-based and region-of-interest-based analyses with covariates of age, gender, and the genotype. Results: In the AD group, Rey Complex Figure Test (RCFT) delayed recall scores were positively correlated with GMV. In the MCI group, Seoul Verbal Learning Test (SVLT) scores were positively correlated with GMV. In the CN group, GMV negatively correlated with Boston Naming Test (K-BNT) scores and Mini-Mental State Examimation (K-MMSE) scores, but positively correlated with RCFT scores. Conclusion: When we used covariates of age, gender, and the genotype, we found statistically significant correlations between some SNSB scores and GMV at some brain regions. It may be necessary to further investigate a longitudinal study to understand the correlation.