• Title/Summary/Keyword: 육안식별

Search Result 107, Processing Time 0.019 seconds

The Study of Influence on Reducing Exposure Dose According to the Applied Flat-panel CT in Extremity Bone SPECT/CT (상·하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: With the demand of SPECT/CT increasing, the interest in complex diagnostic information of CT is rising along with the expansion of various studies on potential performance value. But the study on reduction of exposure dose generated by CT is not being conducted enough. Therefore, in this study, the goal is to identify how much dose reduction exists when performing the extremity bone SPECT/CT using the flat-panel CT. Materials and Methods: The extremity bone SPECT/CT was performed with two equipments -BrightView XCT (Philips Healthcare, Cleveland, USA) and Brilliance 16 CT (Philips Healthcare, Cleveland, USA)-to identify the exposed dose and image quality resulted by changing scan parameter (mAs) applying for both equipment respectively. The noise value of image and spatial resolution were measured with AAPM CT phantom. Tube voltage (kVp) was fixed to 120 kVp, tube current (mAs) calculated at different mA (20, 30, 40, 50, 60, 70, 80) was applied to both equipments respectively. DLP (dose length product) were calculated at the same distance at respective mAs. Also, we acquired images and % contrast with NEMA IEC body phantom to confirm the effect on image. The output of statistics was analyzed by SPSS ver.18. Results: Regarding AAPM phantom, the noise decreased as the tube current (mAs) increased and flat-panel had less noise than Helical CT. This difference increased at lower dose exposure. As to the evaluation of spatial resolution, we can differentiate the space up to 0.75 mm with both equipments. With scan parameter (mA) growing, the value of DLP increased up to 54-216 mGy cm at flat-panel CT and up to 177-709 mGy cm at Helical CT. Regarding NEMA IEC body phantom, same sphere with varied parameter (mA) shows that similar results. Conclusion: There is no significant differences of image quality in both flat-panel and Helical CT when the scan parameter (mA) is changed respectively. Moreover, we can identify the reduction of exposure dose and confirm %contrast analysis value with maintaining image quality. Therefore, at the extremity bone SPECT/CT requiring high spital resolution without the wide ROI, the flat-panel CT is considered to be more useful and it expected to result in the similar image quality with lower exposure dose compared to Helical CT. Additionally, through this study, we expect to help the reduction of the unnecessary exposure dose.

  • PDF

Research on Changing of Renal Relative Uptake Depending on the Setting of Background ROI in Kidney MAG3 Study of Hydronephrosis Patients (Hydronephrosis 환자의 Kidney MAG3 검사 시 Background ROI 설정에 따른 신장 상대 섭취율 변화에 관한 연구)

  • Noh, Ik Sang;Ahn, Byung Ho;Kim, Soo Yung;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.25-30
    • /
    • 2013
  • Purpose: To evaluate kidney function, renal relative uptake is very important and is affected by kidney and the setting of background region of interest (ROI). In particular, in the case of patients with hydronephrosis to the naked eyes, such as size, position and shape etc. can be difficult to identify. So according to ROI to be set by user, the results are many differences. This study assumes the ROI of a constant kidney. According to the change of background ROI by analyzing renal relative uptake affect how the results are intended to study. Materials and Methods: From January 2012 to February 2013, we analyzed 27 patients with hydronephrosis who were examined MAG3 test in nuclear medicine department of Samsung medical center. After patients were received intravenous injection of $^{99m}Tc-MAG3$ 185 MBq (5 mCi) data were obtained. While we reconstructed images of patients, we've changed background ROI in the process of setting up ROI. First, in the process of renal processing, automatic ROI which set automatically and background ROI which needed to set manually were compared. Second, we set the ROI position separated by above, lateral and bottom of kidney. Third, background setting time were compared with 1-2 min and 2-3 min. Results: The relative uptake occurred in 3.7%p of the errors on average in Automatic & Manual ROI study. And comparison of background ROI position study, located in the lower position was more accurate results. Above, lateral, bottom each of the values 74.6%, 67.6% and 62.0% showed respectively. The standard value was 59.9%. finally, split function range test doesn't show significant difference. Conclusion: The study shows that relative uptake of kidney is affected in the background ROI. Therefore, it should be set by considering various dependent factors.

  • PDF

Usefulness of Flow Composite Image in Raynaud Scan ($^{201}Tl$) ($^{201}Tl$을 이용한 레이노 검사에서 동적 Composite 영상의 유용성)

  • Kim, Dae-Yeon;Shin, Gyoo-Seol;Oh, Eun-Jung;Kim, Gun-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.101-104
    • /
    • 2010
  • Purpose: Raynaud scan is divided to flow, blood pool and local-delay image. Usually, we evaluate comparison through blood pool and local-delay image. We will evaluate about usability when comparative observe blood image and local-delay image in Raynaud scan that used $^{201}Tl$ as making flow image to one sheet of images. Materials and Methods: We have selected 29 Raynaud phenomenon patients aged 14~68 years who visited department of vascular surgery between Feb. 2008 and Aug. 2009. An intravenous injection $^{201}Tl$ of 111 MBq (3 mCi) to opposite side diagonal line limbs above an internal auditing department. Equipment used Philips gamma camera forte A-Z, and collimator used LEHR. Matrix size set up to each $64{\times}64$, $128{\times}128$, $256{\times}256$ and zoom factor used to full field. Protocol of dynamic is 2 second to 155 frames. Blood pool and delay count to 300 second. We set up ROI by a foundation to data acquired in PEGASYS processing program. Each results were analyzed with the SPSS 12.0 statistical software. Results: Each averages of count ratio (Rt / Lt) to have been given at composite image, a blood pool image, delay images analyzed at Raynaud phenomenon patients is $1.25{\pm}0.39$, $1.20{\pm}0.33$, $1.11{\pm}0.17$. The sample analysis results of blood pool image and delay image contented itself with p<0.029. Also, there don't have been each difference, and blood pool image, delay image regarding composite image was able to know. Conclusion: We were able to give help for comparison to evaluate a blood pool image and a local delay image at the Raynaud scan which used $^{201}Tl$ while making a flow image to one sheet image. Identification to be visual too was possible. If you are proceeded a researcher that there was further depth, you are more appropriate for, and you may get useful information.

  • PDF

Static and dynamic elastic properties of the Iksan Jurassic Granite, Korea (익산 쥬라기 화강암의 정 및 동탄성학적 특성)

  • Kang, Dong-Hyo;Jung, Tae-Jong;Lee, Jung-Mo
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.2
    • /
    • pp.99-112
    • /
    • 2000
  • The Iksan Jurassic Granite shows relatively less fractures and homogeneous rock fabrics, and is one of the most popular stone materials for architectures and sculptures. Almost mutually perpendicular rift, grain, and halfway in the Iksan Jurassic Granite are well known to quarrymen based on its splitting directions, and therefore it should exhibit orthorhombic symmetry. Theoretically, there are 9 independent elastic stiffness coefficients $(C_{1111},\;C_{2222},\;C_{3333},\;C_{2323},\;C_{1313},\;C_{1212},\;C_{1122},\;C_{2233},\;and\;C_{1133})$ for orthorhombic anisotropy. In order to characterize the static and dynamic elastic properties of the Iksan Jurassic Granite, triaxial strains under uniaxial compressive stresses and ultrasonic velocities of elastic waves in three different polarizations are measured. Both experiments are carried out with six directional core samples from massive rock body. Using the results of experiments and the densities measured independently, the static and dynamic elastic coefficients are computed by simple mathematical manipulation derived from the governing equations for general anisotropic media. The static elastic coefficients increase ar uniaxial compressive stress rises. Among those, the static elastic coefficients at uniaxial compressive stress of a 24.5 MPa appear to be similar to the dynamic elastic coefficients under ambient condition. Although some deviations are observed, the preferred orientations of microcracks appear to be parallel or subparallel to the rift, the grain, and the hardway from microscopic observation of thin sections. This indicates that the preferred orientations of microcracks cause the elastic anisotropy of the Iksan Jurassic Granite. The results are to be applied to the effective use of the Iksan Jurassic Granite as stone materials, and can be used for the non-destructive safety test.

  • PDF

A Study on Rapid Color Difference Discrimination for Fabrics using Digital Imaging Device (디지털 화상 장치를 이용한 섬유제품류 간이 색차판별에 관한 연구)

  • Park, Jae Woo;Byun, Kisik;Cho, Sung-Yong;Kim, Byung-Soon;Oh, Jun-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.29-37
    • /
    • 2019
  • Textile quality management targets the physical properties of fabrics and the subjective discriminations of color and fitting. Color is the most representative quality factor that consumers can use to evaluate quality levels without any instruments. For this reason, quantification using a color discrimination device has been used for statistical quality management in the textile industry. However, small and medium-sized domestic textile manufacturers use only visual inspection for color discrimination. As a result, color discrimination is different based on the inspectors' individual tendencies and work procedures. In this research, we want to develop a textile industry-friendly quality management method, evaluating the possibility of rapid color discrimination using a digital imaging device, which is one of the office-automation instruments. The results show that an imaging process-based color discrimination method is highly correlated with conventional color discrimination instruments ($R^2=0.969$), and is also applicable to field discrimination of the manufacturing process, or for different lots. Moreover, it is possible to recognize quality management factors by analyzing color components, ${\Delta}L$, ${\Delta}a$, ${\Delta}b$. We hope that our rapid discrimination method will be a substitute technique for conventional color discrimination instruments via elaboration and optimization.

Improvement of Mid-Wave Infrared Image Visibility Using Edge Information of KOMPSAT-3A Panchromatic Image (KOMPSAT-3A 전정색 영상의 윤곽 정보를 이용한 중적외선 영상 시인성 개선)

  • Jinmin Lee;Taeheon Kim;Hanul Kim;Hongtak Lee;Youkyung Han
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1283-1297
    • /
    • 2023
  • Mid-wave infrared (MWIR) imagery, due to its ability to capture the temperature of land cover and objects, serves as a crucial data source in various fields including environmental monitoring and defense. The KOMPSAT-3A satellite acquires MWIR imagery with high spatial resolution compared to other satellites. However, the limited spatial resolution of MWIR imagery, in comparison to electro-optical (EO) imagery, constrains the optimal utilization of the KOMPSAT-3A data. This study aims to create a highly visible MWIR fusion image by leveraging the edge information from the KOMPSAT-3A panchromatic (PAN) image. Preprocessing is implemented to mitigate the relative geometric errors between the PAN and MWIR images. Subsequently, we employ a pre-trained pixel difference network (PiDiNet), a deep learning-based edge information extraction technique, to extract the boundaries of objects from the preprocessed PAN images. The MWIR fusion imagery is then generated by emphasizing the brightness value corresponding to the edge information of the PAN image. To evaluate the proposed method, the MWIR fusion images were generated in three different sites. As a result, the boundaries of terrain and objects in the MWIR fusion images were emphasized to provide detailed thermal information of the interest area. Especially, the MWIR fusion image provided the thermal information of objects such as airplanes and ships which are hard to detect in the original MWIR images. This study demonstrated that the proposed method could generate a single image that combines visible details from an EO image and thermal information from an MWIR image, which contributes to increasing the usage of MWIR imagery.

Evaluation of Applicability of Sea Ice Monitoring Using Random Forest Model Based on GOCI-II Images: A Study of Liaodong Bay 2021-2022 (GOCI-II 영상 기반 Random Forest 모델을 이용한 해빙 모니터링 적용 가능성 평가: 2021-2022년 랴오둥만을 대상으로)

  • Jinyeong Kim;Soyeong Jang;Jaeyeop Kwon;Tae-Ho Kim
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_2
    • /
    • pp.1651-1669
    • /
    • 2023
  • Sea ice currently covers approximately 7% of the world's ocean area, primarily concentrated in polar and high-altitude regions, subject to seasonal and annual variations. It is very important to analyze the area and type classification of sea ice through time series monitoring because sea ice is formed in various types on a large spatial scale, and oil and gas exploration and other marine activities are rapidly increasing. Currently, research on the type and area of sea ice is being conducted based on high-resolution satellite images and field measurement data, but there is a limit to sea ice monitoring by acquiring field measurement data. High-resolution optical satellite images can visually detect and identify types of sea ice in a wide range and can compensate for gaps in sea ice monitoring using Geostationary Ocean Color Imager-II (GOCI-II), an ocean satellite with short time resolution. This study tried to find out the possibility of utilizing sea ice monitoring by training a rule-based machine learning model based on learning data produced using high-resolution optical satellite images and performing detection on GOCI-II images. Learning materials were extracted from Liaodong Bay in the Bohai Sea from 2021 to 2022, and a Random Forest (RF) model using GOCI-II was constructed to compare qualitative and quantitative with sea ice areas obtained from existing normalized difference snow index (NDSI) based and high-resolution satellite images. Unlike NDSI index-based results, which underestimated the sea ice area, this study detected relatively detailed sea ice areas and confirmed that sea ice can be classified by type, enabling sea ice monitoring. If the accuracy of the detection model is improved through the construction of continuous learning materials and influencing factors on sea ice formation in the future, it is expected that it can be used in the field of sea ice monitoring in high-altitude ocean areas.