• 제목/요약/키워드: 유효 면적

Search Result 574, Processing Time 0.032 seconds

The Effect of Impact Velocity on Droplet-wall Collision Heat Transfer Above the Leidenfrost Point Temperature (Leidenfrost 지점 온도 이상에서 액적-벽면 충돌 열전달에 대한 충돌 속도의 영향)

  • Park, Jun-seok;Kim, Hyungdae;Bae, Sung-won;Kim, Kyung Doo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.567-578
    • /
    • 2015
  • Single droplet-wall collision heat transfer characteristics on a heated plate above Leidenfrost temperature were experimentally investigated considering the effects of impact velocity. The collision characteristics of the droplet impinged on the heated wall and the changes in temperature distribution were simultaneously measured using synchronized high-speed video and infrared cameras. The surface heat flux distribution was obtained by solving the three-dimensional transient heat conduction equation for the heated substrate using the measured surface temperature data as the boundary condition for the collision surface. As the normal impact velocity increased, heat transfer effectiveness increased because of an increase in the maximum spreading diameter and a decrease in the vapor film thickness between the droplet and heated wall. For We < 30, droplets stably rebounded from a heated wall without breakup. However, the droplets broke up into small droplets for We > 30. The tendency of the heat transfer to increase with increasing impact velocity was degraded by the transition from the rebounding region to the breakup region; this was resulted from the reduction in the effective heat transfer area enlargement due to the breakup phenomenon.

An 1.2V 8-bit 800MSPS CMOS A/D Converter with an Odd Number of Folding Block (홀수개의 폴딩 블록으로 구현된 1.2V 8-bit 800MSPS CMOS A/D 변환기)

  • Lee, Dong-Heon;Moon, Jun-Ho;Song, Min-Kyu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.7
    • /
    • pp.61-69
    • /
    • 2010
  • In this paper, an 1.2V 8b 800MSPS A/D Converter(ADC) with an odd number of folding block to overcome the asymmetrical boundary-condition error is described. The architecture of the proposed ADC is based on a cascaded folding architecture using resistive interpolation technique for low power consumption and high input frequency. The ADC employs a novel odd folding block to improve the distortion of signal linearity and to reduce the offset errors. In the digital block, furthermore, we use a ROM encoder to convert a none-$2^n$-period code into the binary code. The chip has been fabricated with an $0.13{\mu}m$ 1P6M CMOS technology. The effective chip area is $870{\mu}m\times980{\mu}m$. SNDR is 44.84dB (ENOB 7.15bit) and SFDR is 52.17dBc, when the input frequency is 10MHz at sampling frequency of 800MHz.

Occlusion Effect of Dentinal Tubules of the Desensitizing Dentifrices Marketed in Korea (국내 시판중인 지각과민 완화 치약의 상아세관 폐쇄효과)

  • Lee, Su-Young
    • Journal of dental hygiene science
    • /
    • v.11 no.5
    • /
    • pp.431-436
    • /
    • 2011
  • The aim of this study was to compare the effects of the short-term use of the desensitizing dentifrices marketed in Korea in vitro. Fifty human dentine specimens were wet ground with silicone carbide paper and etched with 6% citric acid for 90 seconds to allow complete opening of the dentinal tubule. Ten specimens from each group were brushed for 50 and 150 strokes with a V8 Cross Brushing Machine(Sabri Co., U. S. A). All the specimens were evaluated by SEM(${\times}3000$). The degree of occlusion of the dentinal tubules was quantified using an image analyzer. The results were analyzed by one-way ANOVA and Tukey's multiple comparisons using Window SPSS. The dentifrices containing nano-carbonate apatite, potassium nitrate and hydroxyapatite showed significantly higher occlusion effects than the other dentifrices after toothbrushing for 50 strokes(p<0.05). The Sensodyne freshmint$^{(R)}$dentifrice showed 34% fewer open tubular areas compared with the Sensodyne original$^{(R)}$dentifrice for 50 strokes. According to the short-term use of desensitizing dentifrices, the dentifrices containing nano-carbonate apatite, potassium nitrate and hydroxyapatite were most effective in occluding the dentinal tubules.

Survey on the Farms in Main Producing Area of Job's Tears (율무 주산 지역 농가의 실태조사)

  • 강치훈;박기준;유창재;김두환
    • Korean Journal of Plant Resources
    • /
    • v.14 no.1
    • /
    • pp.77-83
    • /
    • 2001
  • This survey was carried out to collect the basic informations for the improvement of cultivation in job's tears (Coix lachryma-jobi L.) by investigating the general facts, farming practices, growth characteristics, grain yield, and chemical properties of soil in Yonchon-gun farms. The age of farmers were over 51 and the cultivated area was small. Most farmers were self-laboring and produced seeds on their land. Sowing method was usually drilling by hand, 64% of farms had the density of 2000-3500 plant per 10 a, amount of fertilizer application was diverse and the number of pest control was a few. The averages of plant height, number of main culm node, culm diameter, tiller number of plant, thousand grain weight, and grain yield were 184 cm, 10, 10 mm, 14, 108 g, and 341 kg/10a, respectively. The averages of pH, organic matter, $P_2O_5$, K, and EC of soil after harvest were 5.8, 1.1 g/kg, 385 mg/kg, 0.48 cmol+/kg, and 0.21 dS/m, respectively. Grain yield and hardness were negatively correlated -0.7442 at the level of P=0.01.

  • PDF

Occurrence of Jujube Witches' Broom Disease and Control Efficacy of Trunk Injection with Oxytetracycline in Boeun Area from 2018 to 2019 (2018-2019년 보은지역 대추나무 빗자루병 발생 및 옥시테트라사이클린 수간주사 방제 효과)

  • Kang, Hyo-Jung;Choe, Seonghui;Lee, Kyeong Hee;Park, Heesoon;Oh, Ha Kyung;Lee, Seongkyun;Shin, Hyunman
    • Research in Plant Disease
    • /
    • v.26 no.1
    • /
    • pp.19-28
    • /
    • 2020
  • Jujube witches' broom (JWB) disease is a high-risk plant disease that occurred on and devastated jujube orchards throughout South Korea in the 1950s. Recently, as the jujube cultivation area has been significantly increased nationwide, we investigated the disease in jujube orchards in the Boeun region to obtain basic information for proactively evaluating the risk of JWB outbreaks from 2017 to 2019. A field trial was conducted to evaluate the effect of the trunk injection of Sungbocycline (a. i. oxytetracycline calcium alkyl trimethyl ammonium 17%, OTC). The incidence of JWB disease was very low in Boeun, but it was gradually increased mainly in the area and on the farms where it had occurred previously. The trunk injection with OTC was most effective in the early stages of growth. However, even though the trees were treated with OTC, disease symptoms appeared in other healthy branches in severely affected trees. When the tree was first injected with OTC in June, the control efficacy of second injection was higher one month after the first injection than five months. These results suggest that early diagnosis based on various symptoms and early control based on them can be very effective in preventing JWB disease in advance and increasing control efficacy.

Redetermining the curve number of Korean forest according to hydrologic condition class (수문학적 조건 등급에 따른 우리나라 산림의 유출곡선지수 재산정)

  • Park, Dong-Hyeok;Yu, Ji Soo;Ahn, Jae-Hyun;Kim, Tae-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.10
    • /
    • pp.653-660
    • /
    • 2017
  • The SCS-CN (Soil Conservation Service-Curve Number) method has been practically applied for estimating the effective precipitation. The CN is used to be determined according to the land use condition based on the US standard. However, there are two distinctive differences between U.S. and Korean land use conditions: mountainous (forest) and rice paddy area that cover more than 70% of the Korean territory. The previous work proposed to use 79 for rice paddy area, regardless of the soil type. Because US SCS's goal was originally to increase crops, the SCS classification standard provides only for woods and there are no criteria to distinguish the wood and forest. To determine the CN for forest, alternatively the U.S. Forest Service criteria have been employed in practice considering hydrologic condition class. In this study, we investigated the change of the forest CN using the observed rainfall - runoff data within the target area. The results indicated that the CN for forest was suitable for HC=1, and the corresponding CNs were redetermined between 54 and 55.

Effects of Light Intensity on Photosynthesis and Growth in Seedling of Kalopanax pictus Nakai (광강도에 따른 음나무 유묘의 생장 및 광합성 특성)

  • Lee, Cheul-Ho;Shin, Chang-Ho;Kim, Kyu-Sick;Choi, Myung-Suk
    • Korean Journal of Medicinal Crop Science
    • /
    • v.14 no.4
    • /
    • pp.244-249
    • /
    • 2006
  • This study was carried out to determine leaf photosynthetic capacity and growth characteristics of Kalopanax picturs Nakai seedlings under the different light condition. The seedlings grown under low light condition showed larger leaf area and petiole, and higher relative growth rate than those grown under high light condition. Chlorophyll contents as chlorophyll a, chlorophyll b, and chlorophyll a + b were high in the seedlings grown under highlight condition compared to those grown in low light conditions. The mean absorption value of shade leaf within photosynthetically active radiation (400-700 nm) was slightly higher than that of sun leaf, Leaf photosynthetic capacity of seedling was variable under the different light conditions. Seedling grown under high light condition had the higher photosynthetic capacity. Leaf photosynthetic rates under forestry and nursery were 700 and $300\;{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, respectively. However, leaf photosynthetic rates under high and low light conditions were 500 and $300\;{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, respectively.

The Effectiveness of Overtopping Discharge Reduction for Restricted Water Level of Reservoir During Flood Period (홍수기중 저수지의 제한수위에 따른 월류량 저감효과)

  • Kim, Yong-Kuk;Kim, Young-Sung;Noh, Jae-Kyoung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.442-442
    • /
    • 2011
  • 우리나라는 홍수조절이나 통제를 목적으로 10개의 다목적댐을 통한 홍수방재시스템을 운영하고 있다. 다목적댐 또한 방류능력과 저류능력에 한계가 있기 때문에 안정적인 홍수조절을 위해서는 유입량과 유출량을 미리 예측할 수 있어야 한다. 하지만, 강수량은 그 변동이 심하여 정확한 예측이 어렵기 때문에 합리적인 하천 구조물의 설계와 홍수예측기술의 발전을 위해서는 강우-유출 해석뿐만 아니라 과거의 수문자료를 사용한 통계적인 분석이 요구된다. 최근 기후변화로 인해 과거에 겪지 않았던 이상 기후현상이 빈번하게 나타나고 있다. 기상청발표에 따르면 최근 10년간(1996~2005) 15개 지점의 평균 연강수량은 1,458.7 m로 약 10 �時貂� 하였고, 특히 여름철은 18 %로 증가폭이 가장 크며 호우일수는 30년 평균이 2일인데 비하여 2.8일로 0.8일 증가하였다. 이러한 강수량 및 호우일수 증가는 여름철 심각한 수해를 초래할 수 있다. 본 연구는 기후변화로 인한 수해를 대비하여 홍수기중 저수지 제한수위운영의 안정성을 검토하였다. 연구 대상 지역은 광교저수지로 수원천 상류부인 경기도 수원시 장안구 연무동에 위치한다. 유역면적은 10.98 km, 유효저수량은 250.0 만$m3$이며, 현재 예비취수원으로 사용되고 있다. 기후변화에 따른 하류지역의 예상치 못한 홍수피해를 사전에 예방하기 위해 광교저수지 유역의 설계 강수량과 설계 홍수량을 산정하였다. 제한수위의 시나리오는 현재 시행중인 제한수위와 만수위를 포함하여 5개로 설정하였다. 설계 홍수량이 광교저수지로 유입될 때 시나리오에 따른 월류량은 웨어공식을 이용하여 산정하였으며 결론은 다음과 같다. 1. 39년간의 최다 일 강수량 자료를 사용하여 100년 빈도의 설계 강수량을 Gumbel 분포법으로 산정한 결과 344.4 mm임을 알 수 있었다. 2. 광교저수지 유역의 설계 홍수량을 SCS 방법을 이용하여 산정한 결과 $216.2\;m^3/s$/s로 나타났으며, 총 유입량은 $301.0\;m^3$/day로 파악되었다. 3. 광교저수지로 설계홍수량이 유입될 때 제한수위 시나리오에 따른 최대 방류량은 EL. 87 m의 경우 $23.1\;m^3/s$, EL. 89 m의 경우$27.5\;m^3/s$ EL. 91.36 m의 경우 $79.6\;m^3/s$, EL. 93 m의 경우 $121.1\;m^3/s$ EL. 95.2 m의 경우 $137.`\;m^3/s$이다. 광교저수지 하류부분의 하천정비기본계획상의 설계 홍수량은 $114\;m^3/s$로 홍수기중 저수지의 제한수위는 EL. 91.36 m이하로 설정하는 것이 바람직한 것으로 판단된다.

  • PDF

Mass Flow Rate Measurement of Pulsating Flow in a Twin-Scroll Turbocharger (트윈스크롤 터보과급기에서 맥동유동의 질량유량 측정)

  • Chung, Jin-Eun;Jeon, Se-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.723-729
    • /
    • 2019
  • Turbochargers are an effective device to reduce the fuel consumption. In this study, the mass flow rate of pulsating flow in the twin-scroll turbocharger for the gasoline engine of passenger vehicles was measured. Pulsating flow was achieved using a pulse generator and the mass flow rate of the unsteady pulsating flow was analyzed by comparing it with those of the steady flow. The pulse generator consisted of a rotating upper plate and a fixed lower plate. To measure the mass flow rate of unsteady flow, the orifice flow meter equipped with the difference pressure transducer was used. To analyze the low speed performance of the turbocharger, the measurement was carried out in the speed of turbocharger from 60,000rpm to 100,000rpm. The mass flow parameters of the unsteady pulsating flow showed a large difference compared to those of the steady flow. Those of the unsteady flow showed the hysteresis loop surrounding the mass flow parameters of the steady flow and the maximum variation of the mass flow parameters were 5.0 times those of the steady flow. This phenomenon is the result of the filling and emptying the turbine volute space due to pulsating flow.

Determination of fucoxanthin in cosmeceutical products by HPLC-PDA (HPLC-PDA를 이용한 기능성 화장품 중 푸코잔틴의 정량)

  • Choi, Jongkeun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.755-761
    • /
    • 2017
  • This study was conducted to establish an analytical method using an HPLC system equipped with a photodiode array (PDA) detector for the quality control of raw materials and cosmeceuticals containing fucoxanthin as an active ingredient. The column was octadecyl-functionalized silica gel and the measurement wavelength of the PDA was set to 499 nm. To validate the analytical method, the linearity of the calibration curve, detection limit, reproducibility and recovery rate were investigated and good results were obtained. The correlation coefficient of the calibration curve was 1.000 and the linearity was good in the concentration range of 0.5 ~ 100 ppm. Moreover, the limit of detection (LOD) was 0.1 ppm and the limit of quantification (LOQ) was 0.5 ppm. The results of the peak reproducibility test used for evaluating the system suitability showed that the RSD (n = 5) of the peak area was 2.0% and that of the retention time was 0.09%. In the spiking test, the recovery rate was $101.6{\pm}0.77%$. The fucoxanthin contents of the two kinds of fucoxanthin-containing raw materials were $49.6{\pm}3.3%$ and $1.03{\pm}0.016%$, respectively. In addition, the fucoxanthin content in the test product, which was intended to be 150 ppm, was $156.7{\pm}4.7ppm$. From the above results, it was concluded that this method could be applied to the quantitative analysis of fucoxanthin in cosmeceuticals.