• Title/Summary/Keyword: 유효직경

Search Result 213, Processing Time 0.026 seconds

Characteristics of Vortex Shedding behind a Circular Cylinder with Serrated Fins (톱니형 핀이 부착된 튜브의 와유출특성 연구)

  • Bu, Jeong-Suk;Ryu, Byeong-Nam;Kim, Gyeong-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.8
    • /
    • pp.1077-1086
    • /
    • 2001
  • An experimental study is performed to investigate the characteristics of vortex shedding behind a circular cylinder with serrated fins using hot-wire anemometer. Strouhal numbers which are calculated using outer diameter of a circular cylinder with serrated fins are higher than that of a circular cylinder. Fin thickness and pitch are closely related with vortex shedding frequency and play increasing or decreasing vortex shedding after transient Reynolds number. Strouhal numbers using effective diameters which are proposed in this paper agree with that of a circular cylinder. After transient Reynolds number, a trend of Strouhal number can be estimated by checking the ratio of effective diameter to inner diameter.

A study on the compatibility of implant drivers (임플란트 드라이버의 호환성에 대한 연구)

  • Kim, Min-Soo;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.1
    • /
    • pp.34-41
    • /
    • 2014
  • Purpose: In this study, the diameter of each implant driver was measured and compared to find out the compatibility of implant drivers. Materials and methods: Drivers from 12 implant systems being used in Dankook University Dental Hospital were included in this study. The shapes of the implant drivers were segregated, and the effective length and the diameter of upper, middle, lower part of driver tips were measured (n=10). The measured data were mathematically analyzed for its compatibility. Results: A driver with the smallest diameter (1.17 mm) had the highest compatibility at the upper part of driver tip. This driver could be used for a bigger driver up to 1.35 mm in diameter. There were several driver groups which had the same diameter so as to be interchangeable each other. In the middle part, the smallest diameter measured was 1.2 mm and this was able to replace a driver up to 1.40 mm diameter. Since the diameter generally became thicker from upper part (the tip of driver) to the lower part (the shank of driver), some drivers with bigger diameter at the upper part so which was failed to show any compatibility became compatible with a driver which had smaller diameter at the upper part but wider in the middle part. The compatibility of torx shape drivers were affected by the inner diameter of the drivers not only by the outer diameter. Furthermore, the inner diameter of torx drivers decided the compatibility between torx and hex drivers. Conclusion: From the study it was found that compatibility in drivers existed among certain implant systems and to check its compatibility the diameter at a certain effective length should be measured. However, there has been not enough studies about long-term use of compatible drivers, so effects of using compatible drivers on drivers and implants are unknown. Therefore, usage in inevitable cases only is recommended and further study is needed.

Tensile Force Estimation of Externally Prestressed Tendon Using SI technique Based on Differential Evolutionary Algorithm (차분 진화 알고리즘 기반의 SI기법을 이용한 외부 긴장된 텐던의 장력추정)

  • Noh, Myung-Hyun;Jang, Han-Taek;Lee, Sang-Youl;Park, Taehyo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1A
    • /
    • pp.9-18
    • /
    • 2009
  • This paper introduces the application of DE (Differential Evolutionary) method for the estimation of tensile force of the externally prestressed tendon. The proposed technique, a SI (System Identification) method using the DE algorithm, can make global solution search possible as opposed to classical gradient-based optimization techniques. The numerical tests show that the proposed technique employing DE algorithm is a useful method which can detect the effective nominal diameters as well as estimate the exact tensile forces of the externally prestressed tendon with an estimation error less than 1% although there is no a priori information about the identification variables. In addition, the validity of the proposed technique is experimentally proved using a scale-down model test considering the serviceability state condition without and with the loss of the prestressed force. The test results prove that the technique is a feasible and effective method that can not only estimate the exact tensile forces and detect the effective nominal diameters but also inspect the damping properties of test model irrespective of the loss of the prestressed force. The 2% error of the estimated effective nominal diameter is due to the difference between the real tendon diameter with a wired section and the FE model diameter with a full-section. Finally, The accuracy and superiority of the proposed technique using the DE algorithm are verified through the comparative study with the existing theories.

A Study on Shear Capacity and Behavior of Large Sized Concrete Anchorage System (대형 콘크리트 앵커시스템의 전단성능 및 거동특성에 관한 연구)

  • Kim, Kang Sik;Shin, Sung Woo;Lee, Kwang Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.5
    • /
    • pp.82-91
    • /
    • 2011
  • In this study, 24 prototype specimens were tested to find out the shear behavior and strength of large anchorage system exceeding 50mm(2") in anchor bolt diameter($d_0$) and 635mm(25") in effective embedment depth($h_{ef}$) not addressed by ACI349-06 Appendix B. Test variables are anchor bolt diameter($d_0$ = 63.5, 76.2, 88.9mm), effective embedment depth($h_{ef}$=635, 762mm), and edge distance($c_1$=381, 508, 762mm). Concrete compressive strength is constant($f_{ck}$=38MPa). Test results ($V_{test}$) were overestimated by $V_{aci06}$(shear strength by ACI 349-06) and $V_{ccd}$(shear strength by CCD method). In large anchorage system exceeding 50mm(2") of anchor bolt diameter($d_0$) and 635mm(25") of anchor bolt effective embedment depth($h_{ef}$), the bolt diameter variation and effective embedment depth($h_{ef}$) has no influence on the shear strenth, But, according to the analysis results of the feature ratio on edge distance($c_1$) and anchor bolt diameter, the feature ratio become smaller, which means anchor bolt diameter is bigger, predicted ratio of test results and predicted equation is larger. It was found that anchor bolt diameter is immediate cause of deterioration in the shear capacity of large anchorage system. To improve and extend the validity of current design recommendations further theoretical and numerical work is needed.

Characteristics of Near Wake Behind a Circular Cylinder with Serrated Fins (II) - Comparison of Time Mean Flow Fields- - (톱니형 휜이 부착된 원주의 근접후류특성 연구 (II) - 시간평균 유동장 비교 -)

  • Ryu, Byeong-Nam;Kim, Gyeong-Cheon;Bu, Jeong-Suk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1191-1200
    • /
    • 2002
  • The measurements of velocity vectors are made in the near wake(X/d=5.0) of a circular cylinder with serrated fins. Velocity of fluid which flow through fins decreases as increasing fin height and freestream velocity and decreasing fin pitch. Therefore the velocity distribution at X/d=0.0 has lower gradient with increasing freestream velocity and fin height and decreasing fin pitch. The discontinuity of the streamwise velocity gradient is observed near the fin edge and causes significant changes in V-component velocity distribution in the near wake. This change attributes to the differences in Strouhal number and entraintment flow behavior. Increased turbulent intensity around a circular cylinder due to the serrated fins and entrainment flow are important factors for the recovery of velocity defect. The widths of velocity and turbulent intensity distribution of fin tubes are wider than those of a circular cylinder. The normalized velocity and turbulent intensity distributions with a hydraulic diameter which is proposed in this paper are in closer agreement with those of a circular cylinder.

An Experimental Study of Vortex Formation of a Circular Cylinder with Serrated Fins (Serrated Fin Tube 후류에 대한 유동가시화 적용 및 근접후류 특성에 관한 연구)

  • Boo Jung-Sook;Kim Kyung-Chun;Ryu Byong-Nam
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.27-30
    • /
    • 2002
  • An experimental study is performed to investigate the characteristics of near wake behind a circular cylinder with serrated fins using the constant temperature anemometer and through flow visualization. Previous report(Boo at al., 2001) shows that there are three different modes in vortex shedding behavior. This paper is focused on the identification of the physical reasons why the difference is occured in vortex shedding. The through flow velocity crossing fins decreases as increasing fin height and decreasing fin pitch mainly due to the flow resistence. Vortex shedding is affected strongly by velocity distribution around fin tube, especially by the velocity gradient. The velocity distribution at X/d=0.0 has lower gradient with increasing freestream velocity and fin height and decreasing fin pitch. Those differences in velocity gradients generate different vortex shedding mechanism.

  • PDF

Flame Length Scaling in a Non-premixed Turbulent Diluted Hydrogen Jet with Coaxial Air (희석된 동축공기 수소 난류확산화염의 화염 길이 스케일링)

  • Hwang, Jeong-Jae;Oh, Jeong-Seog;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.242-245
    • /
    • 2009
  • The effect of fuel composition on flame length was studied in a non-premixed turbulent diluted hydrogen jet with coaxial air. The observed flame length was expressed as a function of the ratio of coaxial air to fuel jet velocity and compared with a theoretical prediction based on the velocity ratio. Four cases of fuel mixed by volume were determined. In the present study, we derived a scaling correlation for predicting the flame length in a simple jet with coaxial air using the effective jet diameter in the near-field concept. The experimental results showed that visible flame length had a good relation with the theoretical prediction. The scaling analysis is also valid for diluted hydrogen jet flames with varied fuel composition.

  • PDF

KALIMER 우라늄금속핵연료노심의 평형주기 설계인자 변경 연구

  • 김상지;김영인;김영진;박창규
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.64-69
    • /
    • 1998
  • KALMER 우라늄 금속핵연료노심의 평형주기에 대하여 주기길이, 농측도, 중식비의 관점에서 설계인자 변경에 따른 변화를 분석하였다. 유효노심높이, 반경방향 블랑캣의 batch수, 개스팽창모듈(GEM)의 적용성, 노용기내핵 연료저장(IVS)의 사용. 핵연료핀의 직경 증가 둥에 대한 설계 변경이 고려되었다. 본 연구결과를 통하여, 평탄화된 출력분포 및 핵연료의 이용도 향상을 기하면서 설계변경이 타 분야에 미치는 영향을 최소화하고 본래 KALMER의 안전성을 유지하고자 핵연료핀의 직경을 증가시킨 fat pellet 설계방안을 채택하였다

  • PDF

Analysis of Hydrodynamic Similarity in Three-Phase Fluidized Bed Processes (삼상유동층 공정에서 수력학적 Similarity 해석)

  • Lim, Ho;Lim, Hyun-Oh;Jin, Hae-Ryoung;Lim, Dae-Ho;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.790-797
    • /
    • 2011
  • Hydrodynamic similarity was analyzed by employing scaling factor in three phase fluidized beds. The scaling factor was defined based on the holdups of gas, liquid and solid particles and effectivity volumetric flux of fluids between the two kinds of fluidized beds with different column diameter. The column diameter of one was 0.102 m and that of the other was 0.152 m. Filtered compressed air, tap water and glass bead of which density was 2,500 kg/$m^3$ were used as gas, liquid and solid phases, respectively. The individual phase holdups in three phase fluidized beds were determined by means of static pressure drop method. Effects of gas and liquid velocities and particle size on the scaling factors based on the holdups of each phase and effective volumetric flux of fluids were examined. The deviation of gas holdup between the two kinds of three phase fluidized beds decreased with increasing gas or liquid velocity but increased with increasing fluidized particle size. The deviation of liquid holdup between the two fluidized beds decreased with increasing gas or liquid velocity or size of fluidized solid particles. The deviation of solid holdup between the two fluidized beds increased with increasing gas velocity or particle size, however, decreased with increasing liquid velocity. The deviation of effective volumetric flux of fluids between the two fluidized beds decreased with increasing gas velocity or particle size, but increased with increasing liquid velocity. The scaling factor, which was defined in this study, could be effectively used to analyze the hydrodynamic similarity in three phase fluidized processes.