• Title/Summary/Keyword: 유효부착길이

Search Result 33, Processing Time 0.022 seconds

Investigation of Maximum Strength and Effective Bonding Length at the Interface Between Structure and GFRP Material Under Freeze-thaw Cycles and Applied Different Bonding Materials (동결융해 및 부착재료 변화에 따른 GFRP-구조물 경계면의 최대 부착강도 및 유효부착길이 평가)

  • Choi, Hyun Kyu;Jung, Woo Young;Ahn, Mi Kyoung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.2
    • /
    • pp.107-115
    • /
    • 2011
  • This research studies the behavior of the FRP-concrete interface subjected to two environmental substances. Frist is to investigate the behavior by the application of different bonding materials at the interface between FRP and concrete, second is to understand a long-term performance at the interface by Freeze-thaw actions. The parameters considered in this research are the maximum bonding strength and the effective bonding length at the FRP-concrete interface. In the first experimental phase, three types of specimens are fabricated and tested considering the number of applied bonding materials and the Freeze-thaw tests are performed to evaluate the behavior of the interface in the cycle range of 0 to 300 cycles. Finally, it is known that there is a 5~7% difference of the effective bonding length between applied bonding materials and the values for the maximum stress and the effective length under Freeze-thaw action are varied randomly as the freeze-thaw cycle is increased even though initial reduction of their capacities are occurred.

Inverstigation of Maximum Strength and Effective Bonding Length at the Interface between Concrete and FRP Materials under Freeze-thaw Cycles and Applied Different Bonding Materials (동결융해 및 부착재료 변화에 따른 FRP-Concrete 경계면의 최대 부착강도 및 유효부착길이 평가)

  • Kim, Sung-Hoon;Jung, Woo-Young;Choi, Hyun-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.435-436
    • /
    • 2010
  • This research presents two important factors; first, the advanced design equation of effective bonding length at the interface between concrete and FRP materials is proposed when different bonding materials are applied and secondly maximum bonding strength between concrete-FRP bonding surface is evaluated under Freeze-thaw cycles.

  • PDF

The Prediction of Debonding Strength on the Reinforced Concrete Beams Strengthened with fiber Reinforced Polymer (섬유복합체로 휨보강된 RC보의 박리하중 예측에 관한 연구)

  • Hong Geon-Ho;Shin Yeong-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.903-910
    • /
    • 2005
  • In recent years, fiber reinforced polymer(FRP) plates have shown a great promise as an alternative to steel plates for reinforced concrete beam rehabilitation. Reinforced concrete beams strengthened with externally bonded FRP sheets to the tension face can exhibit ultimate flexural strengths several times greater than their original strength if their bond strength is enough. Debonding failure, however, may occur before the strengthened beam can achieve its enhanced flexural strength. The purpose of this paper is to investigate the debonding failure strength of FRP-strengthened reinforced concrete beams. An analytical procedure for calculating debonding load between concrete and strengthening FRP is presented. Based on the local bond stress-slip relationship in the previous studies, uniform bond stress is assumed on the effective bond length. The analytical expressions are developed from linear elastic theory and statistical analyses of experimantal results reported in the literature. The proposed method is verified by comparisons with experimental results reported in the previous researches.

Experimental Study on Bond Strength between Carbon Fiber Sheet and Concrete (탄소섬유쉬트와 콘크리트의 부착강도 실험연구)

  • 유영찬;최기선;최근도;이한승;김긍환
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.2
    • /
    • pp.168-174
    • /
    • 2001
  • Carbon fiber sheet(CFS) has been widely used for strengthening of the concrete building structures due to its excellent physical properties such as high strength, light weight and high durability. Bond strength or behavior, on the other hands, between carbon fiber sheet and concrete is very important in strengthening the concrete member using CFS. Therefore the bond failure mechanism between CFS and concrete should be fully verified and understood. This study is to investigate the bond strength of CFS to the concrete by the direct pull-out test and the tensile-shear test. In the direct pull-out tests, the bond strength under the various environmental conditions such as curing temperature, surface condition on concrete and water content of concrete are evaluated. Also, the effective bond length, lu and the average bond stress, $\tau$y are examined in the tensile-shear tests. Based on the test results, it is concluded that the curing temperature is the most critical element for the bond strength between CFS and concrete. And, the proper value of lu and $\tau$y is recommended with 15 cm and 9.78∼ 11.88 kgf/$\textrm{cm}^2$ respectively.

Bonding Characteristics of Basalt Fiber Sheet as Strengthening Material for Railway Concrete Structures (Basalt 섬유쉬트의 철도시설 콘크리트구조물 보강재로서의 부착거동 연구)

  • Park, Cheol-Woo;Sim, Jong-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.5
    • /
    • pp.641-648
    • /
    • 2009
  • Concrete structures become more common in railway systems with an advancement of high speed train technologies. As the service life of concrete structures increases, structural strengthening for concrete structures may be necessary. There are several typical strengthening techniques using steel plate and fiber reinforced polymer (FRP) materials, which have their own inherent shortcomings. In order to enhance greater durability and resistance to fire and other environmental attacks, basalt fiber material attracts engineer's attention due to its characteristics. This study investigates bonding performance of basalt fiber sheet as a structural strengthening material. Experimental variables include bond width, length and number of layer. From the bonding tests, there were three different types of bonding failure modes: debonding, rupture and rip-off. Among the variables, bond width indicated more significant effect on bonding characteristics. In addition the bond length did not contribute to bond strength in proportion to the bond length. Hence this study evaluated effective bond length and effective bond strength. The effective bond strength was compared to those suggested by other researches which used different types of FRP strengthening materials such as carbon FRP.

Verification of Parameters Influencing Bond Strength between Fiber-Reinforced Polymer Laminates and Concrete (연속섬유(FRP)시트와 콘크리트의 부착강도 영향 요인 검증)

  • Ko, Hune-Bum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.414-423
    • /
    • 2020
  • Fiber-reinforced polymer (FRP) laminate sheets, which are lightweight with high strength, are commonly used to reinforce concrete structures. The bonding strength is vital in structural design. Therefore, experiments and analytical studies with differing variables (concrete compressive strength and tensile strength, the elastic modulus of concrete and FRP, thickness of concrete and FRP, width of concrete and FRP, bond length, effective bond length, fracture energy, maximum bond stress, maximum slip) have been conducted to obtain an accurate numerical model of the bond strength between an FRP sheet and concrete. Although many models have been proposed, no validated model has emerged that could be used easily in practice. Therefore, this study analyzed the parameters that influence the bond strength that were used in 23 of the proposed models (Khalifa model, Iso model, Maeda model, Chen model, etc.) and compared them to the test results of 188 specimens via the numerical results of each model. As a result, an easy-to-use practical model with a simple and high degree of expression was proposed based on the Iso model combined with the effective bond length model that was proposed by Holzenkӓmpfer.

Splice Strengths of Noncontact Lap Splices Using Strut-and-Tie Model (스트럿-타이 모델을 이용한 비접촉 겹침 이음의 이음 강도 산정)

  • Hong, Sung-Gul;Chun, Sung-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.2
    • /
    • pp.199-207
    • /
    • 2007
  • Strut-and-tie models for noncontact lap splices are presented and parameters affecting the effective lap length $(l_p)$ and the splice strength are discussed in this paper. The effective lap length along which bond stress is developed is shorter than the whole lap length. The effective lap length depends on the transverse reinforcement ratio $({\Phi})$ and the ratio of spacing to lap length $({\alpha})$. As the splice-bar spacing becomes wider, the effective lap length decreases and, therefore, the splice strength decreases. The influence of the ratio ${\alpha}$ on the effective lap length becomes more effective when the transverse reinforcement ratio is low. Because the slope of the strut developed between splice-bars becomes steeper as the ratio ${\Phi}$ becomes lower, the splice-bar spacing significantly affects the effective lap length. The proposed strut-and-tie models for noncontact lap splices are capable of considering material and geometric properties and, hence, providing the optimal design for detailing of reinforcements. The proposed strut-and-tie model can explain the experimental results including cracking patterns and the influence of transverse reinforcements on the splice strength reported in the literature. From the comparison with the test results of 25 specimens, the model can predict the splice strengths with 11.1% of coefficient of variation.

Bond Capacity of Pseudo-Ductile FRP Hybrid Sheet to Strengthen RC Members (철근콘크리트 부재 보강용 유사연성 FRP 하이브리드 시트의 부착 특성)

  • Yoon, Hye-Sun;Lee, Jung-Mi;Lee, Chin-Yong;Choi, Dong-Uk;Kim, Kil-Hee
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.1
    • /
    • pp.47-53
    • /
    • 2009
  • 12 concrete blocks, on which hybrid fibrous sheets (carbon fiber and glass fiber) had been bonded, were subjected to tensile load in order to estimate properties of the bonded interface. the sheet length was varied by 100mm, 200mm and 400mm. It was found that more than 150mm bond length is required to achieve the maximum bearing capacity of the interface. In this study, maximum bond stress $\tau_{F,max}$, ultimate slip $S_{FU}$ of the interface were estimated $\tau_{F,max}$=3.0MPa and $S_{FU}$= 0.175mm, respectively.

Evaluation of Ultimate Stress of Unbonded Tendon in Prestressed Concrete Members (II) -Proposed Design Equation using Strain Compatibility (프리트레스트 콘크리트 부재에서 비 부착 긴장재의 극한응력 평가에 관한 연구(II))

  • 임재형;문정호;음성우;이리형
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.5
    • /
    • pp.105-114
    • /
    • 1997
  • 본 연구는 비부착 긴장재를 갖는 부재에 대한 일련의 연구중 두 번째에 해당한다. 첫 번째 연구(1)에서는 기존연구의 제안식과 현행의 ACI 규준의 문제점을 고찰하고 기존의 총 167개 실험결과와 비교·분석하였다. 본 연구에서는 소성힌지 길이 개념과 변형도 적합조건에 의해서 비부착 긴장재의 응력을 평가할 수 있는 방법에 대한 검토를 통하여, 새로운 설계식을 제안하였다. 이는 이론적인 분석에 의한 변수설정과 기존 실험결과를 이용한 중회귀분석법을 사용하였다. 그리고 제안된 설계식을 기존의 식들과 비교하여 좋은 결과를 얻었으며, 제안된 설계식의 특성을 다음과 같이 설명하였다. (1)비부착 긴장재의 응력산정시 유효프리스트레스, 일반철근의 양, 작용하중의 형태 등은 중요한 변수로 작용할 수 있으므로 설계식에 고려하는 것이 바람직하다. (2)비부착 긴장재의 응력산정식은 현행 ACI 규준식과는 다르게 fc'/ p항의 제곱근과 비례하는 함수관계에 있다. (3)스팬-춤비가 비부착 긴장재의 응력에 미치는 영향은 소성힌지 길이의 개념에 의해서 역학적으로 타당하게 설명할 수 ldT다.

The Analysis for Reinforced Concrete Beams Strengthened with Externally Unbonded Prestressed CFRP Plates (비부착 탄소섬유판 긴장재로 외부 긴장 보강된 철근콘크리트 보의 해석)

  • Park, Jong Sup;Jung, Woo Tai;Park, Young Hwan;Kim, Chul Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.439-445
    • /
    • 2008
  • This paper suggests a modified bond reduction coefficient considering the average CFRP (Carbon Fiber Reinforced Polymer) strain concept for the unbonded prestressed CFRP plate strengthening system. The strengthened length and the pure bending length were seen to influence the variation of the strain of unbonded CFRP plate. Therefore, a new bond reduction coefficient considering such effect was suggested. Comparison with the experimental data revealed that the analytic results obtained by considering the proposed bond reduction coefficient were effective in estimating the strain of the unbonded CFRP plate in the CFRP plate prestressing system.