• Title/Summary/Keyword: 유해가스

Search Result 639, Processing Time 0.031 seconds

Modeling of Damage Effects Caused by Ammonia Leakage Accidents in Combined Cycle Power Plant (복합화력발전소 내 암모니아 누출 사고에 의한 피해영향 모델링)

  • Eun-Seong Go;Kyeong-Sik Park;Dong-Min Kim;Young-Tai Noh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.3
    • /
    • pp.1-15
    • /
    • 2023
  • This study focuses on modeling the impact of ammonia leakage from the storage tank in a combined cycle power plant's flue gas denitrification facility. It employs accident impact assessments and diffusion models to determine the optimal scenarios for ammonia storage tank leakage accidents. The study considers the operating conditions of variables as standard conditions for predicting the extent of damage. The Taean combined cycle power plant is chosen as the target area, taking into account seasonal factors such as temperature, humidity, wind speed, atmospheric stability, and wind direction. By utilizing a Gaussian diffusion model, the concentration of ammonia gas at various locations is estimated to assess the potential extent of external damage resulting from a leak. The study reveals that in conditions of high temperature and stable atmosphere within the specified range, lower wind speeds contribute to increased damage to the human body due to ammonia diffusion.

Status of Health and Safety Management in Occupational Hygiene Laboratories in Korea

  • Yang, Hyukseung;Choi, Jaewook;Yoon, Seokjoon;FARR, Terry
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.1
    • /
    • pp.53-62
    • /
    • 2007
  • 목적: 1990년대 초반부터 시작된 우리나라의 산업 보건에 대한 사회적 관심의 증대와 시장의 요구에 따라 산업위생기관의 양적인 팽창이 이루어지긴 하였으나 실험실 관련 안전보건규정이 미비한 상태에서 추진되어 산업위생 실험실에서 다양한 유해 위험성 인자를 취급함에도 불구하고 사용되는 량이 소규모로 인해 안전보건과 관련된 사항은 대부분 간과하고 있으며, 산업위생 실험실의 안전보건관리 실태는 선진외국에 비해 상당히 낙후되어 있는 실정이다. 따라서 본 연구는 우리나라 산업위생 실험실과 관련한 안전보건관리 실태를 평가함으로써 향후 실험실의 안전보건관리 수준을 향상 시키는데 효과적인 자료로 활용하는데 기여하고자 한다. 방법: 산업위생실험실의 안전보건 실태를 파악하기 위해 설문조사를 수행하였으며, 설문은 실험실의 전반적인 안전보건, 화학물질 저장 및 용기, 가연성 및 인화성 화학물질, 가스 실린더, 의사전달, 응급처치 및 비상사태 장비, 정리정돈, 소방안전, 전기안전, 개인보호구, 흄후드 및 환기, 및 이황화탄소 취급 사례로서 12개 영역으로 구성되었다. 연구대상은 2001년 한국산업안전공단 정도관리프로그램에 참여한 기관으로서 총 대상은 119개 기관이었다. 연구기간은 2002년 7월 01일부터 8월 30일까지 약 60일 이었다. 설문은 반송봉투에 넣어 설문완성 후 연구자에게 보낼 수 있도록 배려하였으며, 1차 설문을 보낸 후 2주 후에 설문 참여를 독려하기 위해 엽서를 발송하였고, 다시 2주 후에 각 산업위생기관에 개별 전화 연락을 취하였다. 그 결과 63% (75개 기관)의 완성된 설문을 얻을 수 있었다. 설문의 총 조사항목은 79문항으로 구성되어 있으며, 산업위생실험실의 안전보건 수준을 정량적으로 평가하기 위해 안전보건 매뉴얼, 교육훈련프로그램 및 한국산업안전공단 실험실 지침서를 보유한 기관과 그렇지 않은 기관간의 차이는 선별된 67문항에 대해 각 문항에 합당하거나 적절할 경우 1점을 부여하는 방식으로 점수화하였다. 이들의 관련성을 파악하기 위하여 Microsoft-Excel 2000 프로그램을 이용하여 two-tailed t-test 분석을 실시하였다. 결과 1. 산업위생실험실 운영과 관련한 67개 항목(항목별로 각 1점 부여)에 대한 안전보건 성과지수화 (100점으로 점수 환산) 결과 안전보건 매뉴얼을 보유한 기관은 $42.98{\pm}13.36$(p<0.001)점, 교육훈련프로그램을 보유한 기관은 $50.75{\pm}14.12$(p<0.01)점, 한국산업안전공단 실험실 지침서를 보유한 기관은 $43.58{\pm}11.92$(p<0.01)점으로 그렇지 않은 기관에 비해 통계적으로 유의하게 높은 점수분포를 보였다. 2. 화학물질 보관 캐비닛이 있는 기관 중 64.8%의 기관은 화학물질을 알파벳 순으로, 27.8%는 분류 기준에 따라, 그리고 7.4%는 무작위로 보관하고 있었다. 3. 단지 8.0% (6개)의 기관만이 실험실내에 눈세정 분수(2 개), 샤워기(3개) 및 눈세정물병(3개, 2개 중복 응답 기관)과 같은 응급처치 장치 및 물품을 갖추고 있었다. 4. 89.0%의 기관이 흄후드내에 화학물질을 보관하고 있었다. 5. 물질안전보건자료, 흄후드 기록지, 비상사태 절차서 및 한국산업안전공단 실험실 지침서와 같은 문서관리는 부적절하게 관리 및 기록되고 있었다. 6. 대부분의 산업위생 실험실은 응급처치 장비, 화학물질 또는 가스용기 보관실과 같은 실험실 안전설비가 부족할 뿐만 아니라 정리정돈, 화학물질 저장 캐비닛, 안전보호구 및 흄후드와 같은 관리가 미비하였다. 결론: 이상의 결과에 근거하여 기관장은 실험실의 안전보건관리를 위하여 문서관리체계를 제공하고, 모든 실험실 종사자가 적절한 개인보호구를 착용할 수 있도록 하며, 비상 장비를 설치하고, 실험실과 관련한 적절한 규정을 제정하며, 교육훈련 프로그램을 제공하여야 한다. 또한 실험실 종사자는 실험 중 적절한 개인보호구의 착용하고, 비상장비 이용에 대한 교육훈련에 참여하며, 적절한 실험실 운영관리에 대한 책임감을 가져야 한다. 위의 권고사항 이행을 위해서 KOSHA는 KQCP 프로그램에 실험실 안전보건관리 항목을 삽입하여 주기적인 평가를 수행할 필요가 있다. 우리나라 실험실의 특성을 고려할 때 본 연구결과는 일반 실험실에도 적용될 수 있을 것으로 생각된다.

Method of Nitrate Nitrogen Determination for Plant, Soil and Water Analysis by E. coil Cells (E. coli 세포(細胞)를 이용한 식물(植物), 토양(土壤) 및 수질(水質)의 질산태(窒酸態) 질소(窒素) 분석방법(分析方法))

  • Sohn, Sang Mok;Kucke, Martin;Lee, Yoon Gun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.30 no.4
    • /
    • pp.361-369
    • /
    • 1997
  • A microbiological nitrate determination method by E. coli is modified in Korea, using K12 wildtype, KCTC 1116, for the quantitative reduction of $NO_3{^-}$ to $NO_2{^-}$. The nitrate in plant, soil or water sample is determined spectrophotometrically after being diazotized with sulfaniamide and N-(1-naphthl)-ethlenediamine. The modified E. coli cell method and principle for nitrate determination using Korean wildtype E. coli strain is described, and cell culture and preparation of stock suspension for E. coli as well. This modified E. coli cell method can be managed simply and fast, it is suitable for the investigation of the large serials, it can be also automated and has a high degree of sensitivity up to 0.01ppm $NO_3{^-}-N$ in the sample solution. The applicability of the modified E. coli cell method has been tested for plant, soil and water analysis on a wide range of different samples. Recovery rates of added nitrate have been determined and comparisons with other standard nitrate analytical procedures have been carried out. The results with the modified E. coli cell method show high correlation ($r^2=0.98$) with those gained by the standard analytical procedures. The advantages and disadvantages of the method are also discussed to other nitrate determination methods.

  • PDF

Establishment of Analytical Method for Dichlorprop Residues, a Plant Growth Regulator in Agricultural Commodities Using GC/ECD (GC/ECD를 이용한 농산물 중 생장조정제 dichlorprop 잔류 분석법 확립)

  • Lee, Sang-Mok;Kim, Jae-Young;Kim, Tae-Hoon;Lee, Han-Jin;Chang, Moon-Ik;Kim, Hee-Jeong;Cho, Yoon-Jae;Choi, Si-Won;Kim, Myung-Ae;Kim, MeeKyung;Rhee, Gyu-Seek;Lee, Sang-Jae
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.3
    • /
    • pp.214-223
    • /
    • 2013
  • BACKGROUND: This study focused on the development of an analytical method about dichlorprop (DCPP; 2-(2,4-dichlorophenoxy)propionic acid) which is a plant growth regulator, a synthetic auxin for agricultural commodities. DCPP prevents falling of fruits during their growth periods. However, the overdose of DCPP caused the unwanted maturing time and reduce the safe storage period. If we take fruits with exceeding maximum residue limits, it could be harmful. Therefore, this study presented the analytical method of DCPP in agricultural commodities for the nation-wide pesticide residues monitoring program of the Ministry of Food and Drug Safety. METHODS AND RESULTS: We adopted the analytical method for DCPP in agricultural commodities by gas chromatograph in cooperated with Electron Capture Detector(ECD). Sample extraction and purification by ion-associated partition method were applied, then quantitation was done by GC/ECD with DB-17, a moderate polarity column under the temperature-rising condition with nitrogen as a carrier gas and split-less mode. Standard calibration curve presented linearity with the correlation coefficient ($r^2$) > 0.9998, analysed from 0.1 to 2.0 mg/L concentration. Limit of quantitation in agricultural commodities represents 0.05 mg/kg, and average recoveries ranged from 78.8 to 102.2%. The repeatability of measurements expressed as coefficient of variation (CV %) was less than 9.5% in 0.05, 0.10, and 0.50 mg/kg. CONCLUSION(S): Our newly improved analytical method for DCPP residues in agricultural commodities was applicable to the nation-wide pesticide residues monitoring program with the acceptable level of sensitivity, repeatability and reproducibility.

A Study on Chemical Composition of Fine Particles in the Sungdong Area, Seoul, Korea (서울 성동구 지역 미세먼지의 화학적 조성에 관한 연구)

  • 조용성;이홍석;김윤신;이종태;박진수
    • Journal of Environmental Science International
    • /
    • v.12 no.6
    • /
    • pp.665-676
    • /
    • 2003
  • To investigate the chemical characteristics of PM$\_$2.5/ in Seoul, Korea, atmospheric particulate matters were collected using a PM$\_$10/ dichotomous sampler including PM$\_$10/ and PM$\_$2.5/ inlet during the period of October 2000 to September 2001. The Inductively Coupled Plasma-Mass Spectromety (ICP-MS), ion Chromatography (IC) methods were used to determine the concentration of both metal and ionic species. A statistical analysis was performed for the heavy metals data set using a principal component analysis (PCA) to derived important factors inherent in the interactions among the variables. The mean concentrations of ambient PM$\_$2.5/ and PM/sub10/ were 24.47 and 45.27 $\mu\textrm{g}$/㎥, respectively. PM$\_$2.5/ masses also showed temporal variations both yearly and seasonally. The ratios of PM$\_$2.5/PM$\_$10/ was 0.54, which similar to the value of 0.60 in North America. Soil-related chemical components (such as Al, Ca, Fe, Si, and Mn) were abundant in PM$\_$10/, while anthropogenic components (such as As, Cd, Cr, V, Zn and Pb) were abundant in PM2s. Total water soluble ions constituted 30∼50 % of PM$\_$2.5/ mass, and sulfate, nitrate and ammonium were main components in water soluble ions. Reactive farms of NH$_4$$\^$+/were considered as NH$_4$NO$_3$ and (NH$_4$)$_2$SO$_4$ during the sampling periods. In the results of PCA for PM$\_$2.5/, we identified three principal components. Major contribution to PM$\_$2.5/ seemed to be soil, oil combustion, unidentified source. Further study, the detailed interpretation of these data will need efforts in order to identify emission sources.

Trace Element Analysis and Source Assessment of Household Dust in Daegu, Korea (대구지역 일반주택의 축적먼지 중 미량원소성분 분석과 오염원 평가)

  • Do, Hwa-Seok;Song, Hee-Bong;Jung, Yeoun-Wook;Yoon, Ho-Suk;Kwak, Jin-Hee;Han, Jeong-Uk;Kang, Hye-Jung;Phee, Young-Gyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.1
    • /
    • pp.69-78
    • /
    • 2010
  • In order to investigate the degree of household dust contamination, 48 samples of household dust (24 from urban area and 24 from rural area) in Daegu city were collected in vacuum cleaner during January to February 2009. Samples were sieved below 100 ${\mu}m$, and 14 elements (Al, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, V, Zn) were analyzed using ICP after acid extraction. Results obtained from the source assessment of trace elements using enrichment factor showed that Ca, Fe, K, Mg, Mn, Na, and V were influenced by natural sources such as weathered rock and resuspended soil, while Cd, Cr, Cu, Ni, Pb and Zn were influenced by anthropogenic sources such as fuel combustion and waste incineration. Concentrations were remarkably higher in components from natural sources than in components from urban anthropogenic sources. Household dust in urban area was more affected by anthropogenic sources compared with that of rural area. Pollution index of heavy metals revealed that urban area was 1.8 times more contaminated with heavy metal components than rural area. The correlation analysis among trace elements indicated that components were correlated with natural sources-natural sources (Al-Mg, Al-Mn, Fe-Mn) and natural sources-anthropogenic sources (Al-V, Fe-Cr, V-Mn) in both urban area and rural area. Trace element components of rural area were more correlated than those of urban area. Houses that use oil for heating fuel had relatively higher contents of heavy metals rather than those using gas or electricity for heating fuel. Houses with children also had higher contents of heavy metals. In addition, the age of houses was found to influence the heavy metal levels in household dusts, with older houses (>10years) having higher concentrations than newer houses (<10years) and houses located near the major road (<10 m) were found to have relatively higher heavy metal levels in household dust.

Effect of Reaction Factors on the Properties of Complex Oxide Powder Produced by Spray Roasting Process (분무배소법에 의해 생성되는 복합산화물 분말들의 특성에 미치는 반응인자들의 영향)

  • 유재근;이성수;박희범;안주삼;남용현;손진군
    • Resources Recycling
    • /
    • v.9 no.4
    • /
    • pp.16-27
    • /
    • 2000
  • In order to produce raw material powder of advanced magnetic material by spray roasting process, newly modified spray roasting system was developed in this work. In this spray roasting system, raw material solution was effectively atomized and sprayed into the reaction furnace. Also, uniform temperature distribution inside reaction furnace made thermal decomposition process fully completed, and produced powder was effectively collected in cyclone and bag filter. This system equipped with apparatus which can purify hazard produced gas. In this study complex acid solution was prepared by dissolution of mill scale and ferro-Mn into the acid solution, and the pH of this complex acid solution was controlled about to 4. It was conformed that mill scale and ferro-Mn containing a lot of impurities such as $SiO_2$, P and Al could be used as raw material by reducing the impurities content of complex acid solution below 20 ppm. Complex oxide powder of Fe-Mn system was produced by spraying purified complex acid solution into the spray roaster through nozzle, and the variations of produced powder characters were studied by changing he reaction conditions such as reaction temperature, the injection velocity of solution and air, nozzle tip size and concentration of solution. The morphology of produced powder had spherical shape under the most experimental conditions, and concentration of solution. The morphology of produced powder has spherical shape under the most experimental conditions, and the composition and the particle size distribution were almost uniform, which tells the excellence of this spray roasting system. The grain size of most produced powder was below 100 nm. From the above results, it will be possible to produce ultra fine oxide powder from the chloride of Fe, Mn, Ni, Cu and rare earth by using this spray roasting system, and also to produce ultra fine pure metal powder by changing reaction atmosphere.

  • PDF

Evaluation on Heating Effects of Geothermal Heat Pump System in Farrowing House (지열 난방시스템을 이용한 분만돈사의 난방효과 분석)

  • Choi, H.C.;Park, Jae-Hong;Song, J.I.;Na, J.C.;Kim, M.J.;Bang, H.T.;Kang, H.G.;Park, S.B.;Chae, H.S.;Suh, O.S.;Yoo, Y.S.;Kim, T.W.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.205-215
    • /
    • 2010
  • Geothermal heat pump system (GHPS) is an energy-efficient technology that use the relatively constant and renewable energy stored in the earth to provide heating and cooling. With the aim of using GHPS as a heating source, it's possibilities of application in farrowing house were examined by measuring environmental assessment and sow's performance. A total of 96 sows were assigned to 2 pig housings (GHPS and conventional housing) with 48 for four weeks in winter season. During the experimental period, indoor maximum temperature in GHPS-housing was measured up to $26.7^{\circ}C$, average temperature could maintain $21.2^{\circ}C$. The mean value of dust levels and $CO_2$, $NH_3$ and $H_2S$ gas emissions were decreased in GHPS-housing compare with those of conventional housing. Litter size, birth weight, parity and weaning weight did not differ between housings. However, feed intake of sow in GHPS-housing was lower than that of conventional housing. In energy consumption for heating, electric power consumption increased in GHPS-housing than the conventional housing, a 2,250 kwh increase, whereas there is no fuel usage for heater in GHPS-housing. Amount of ground water circulated for heating in cold weather for earth heat exchanger was 8.4-12.9 ton per day. In conclusion, GHPS may have environmental benefits and effectiveness of heating in farrowing housing and affect the performance in sows.

A study on the fire characteristics according to the installation type of large smoke exhaust port in a small cross sectional tunnel fire (소단면 대심도 터널 화재시 대배기구의 설치형태에 따른 화재특성 연구)

  • Choi, Pan-Gyu;Baek, Doo-San;Yoo, Ji-Oh;Kim, Chang-Yong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.201-210
    • /
    • 2019
  • Recently, due to the efforts to mitigate traffic congestion and expansion of space efficiency, the construction of underground roads has been increased in big-scale cities. Since tunnels in the city have a higher chance for a fire leading to a great tragedy during a severe traffic jam than mountain tunnels, it is highly likely that it will be constructed as a tunnel, having a small cross section, for small vehicles. However, if they are constructed as such small-vehicle tunnels, it would be possible to reduce the design fire intensity while the concentration of harmful gases would increase due to a reduction in the small cross sectional area, led by a decrease in the tunnel height. In this study, behaviors of fire smoke by the installation interval and format of large-scale exhaust-gas ports were examined and compared in the analysis of temperatures and CO concentrations of a tunnel and its results were as the following. Although there were no significant differences in the smoke spreading distance between installation intervals, but in this study, 100 m was found to be the most effective installation interval. The smoke exhaustion performance was found to be excellent in the order of $4m{\times}3m$, $6m{\times}2m$, and $3m{\times}2m$ (2 lane) of the smoke spreading distance. Although there was no significant difference in the smoke spreading distance between formats of large-scale exhaust-gas ports, it was found that the smoke spreading distance was larger than other cases when it was $3m{\times}2m$ in the fire growing process. The analysis of smoke spreading distances by the aspect ratio showed that a smoke spreading distance was shorted when its the smoke spreading distance was found to be shorter when its traverse distance was relatively longer than its longitudinal distance.