• Title/Summary/Keyword: 유한요소 해석

Search Result 9,816, Processing Time 0.045 seconds

A study on the acoustic performance of an absorptive silencer applying the optimal arrangement of absorbing materials (흡음재 최적 배치를 적용한 흡음형 소음기의 음향성능 연구)

  • Dongheon Kang;Haesang Yang;Woojae Seong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.261-269
    • /
    • 2024
  • In this paper, the acoustic performance of an absorptive silencer was enhanced by optimizing an arrangement of multi-layered absorbing materials. The acoustic performance of the silencer was evaluated through transmission loss, and finite element method-based numerical analysis program was employed to calculate the transmission loss. Polyurethane, a porous elastic material frequently used in absorptive silencers, was employed as the absorbing material. The Biot-Allard model was applied, assuming that air is filled inside the polyurethane. By setting the frequency range of interest up to the 2 kHz and the acoustic performance affecting properties of the absorbing materials were investigated when it was composed as a single layer. And the acoustic performance of the silencers with the single and multi-layered absorbing materials was compared with each other based on polyurethane material properties. Subsequently, the arrangement of the absorbing materials was optimized by applying the Nelder-Mead method. The results demonstrated that the average transmission loss improved compared to the single-layered absorptive silencer.

Estimation of Safety and Economical Efficiency of Large High Tension Bolted Joints (대직경 고장력볼트 이음부의 안전성 및 경제성 평가)

  • Sung, Ki-Tae;Kyung, Kab-Soo;Lee, Seung-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.6 s.58
    • /
    • pp.97-105
    • /
    • 2009
  • This study was conducted for the purpose of examinating the safety and economical efficiency of large high tension bolted joints. The specimen using F10T-M30 large high strength bolts has been selected and static tensile test has been conducted to evaluate the slip characteristics. In addition, finite element analysis has been carried out to estimate the number of required bolts. As a result, the average slip coefficient of M30 high strength bolts exceeded 0.4 - the standard in highway bridge design specification - and has satisfied the slip strength, which is the same as that of M22 high strength bolts. In addition, if F13T-M22 high strength bolts were applied, the number of required bolts decreased by 21%, and if F10T-M30 high strength bolts were applied, the number of required bolts decreased by 46%, that leads to the conclusion that the economical efficiency in accordance with diametering of high strength bolts was now verified.

A Study on the Structural Design of Permeable Asphalt Pavement (투수성 아스팔트포장 구조설계방법에 관한 연구)

  • Lee, Soo-Hyung;Yoo, In-Kyoon;Kim, Je-Won
    • International Journal of Highway Engineering
    • /
    • v.13 no.3
    • /
    • pp.39-49
    • /
    • 2011
  • The porous pavement system is widely considered very effective in urban street because of its various benefits on safety and environment, but the pavement thickness design system has not been established yet. In porous pavement system. rainwater penetrates to the subgrade through porous pavements layers. Porous pavements are expected to reduce or alleviate the problems caused by impermeable pavement layer such as flood damage due to heavy rain in the city, drainage load, disorder in ecosystem, and heat island. However, its structural design methods in traffic roads has not been made mainly because of not being able to consider adequately the effect of rainwater on subgrade strength. In this study, structural design method of porous pavements is suggested after considering the subgrade weakness due to rainwater and numerical mechanical analysis. It is noted that elastic modulus of subgrade is reduced by 20% as subgrade moisture content is increased by 2% at optimum moisture content in the literature review. As a result of both finite element analysis and strength loss of subgrade by the existing design method, it is necessary to increase subbase thickness about 30cm in porous pavements compared with the existing traffic road pavement system. It is similar to premium thickness of structural design of porous pavements in Japan.

Numerical Analysis of Flow Pattern by Outflow Gates with Manifold Channel (다기수로를 가진 수중 유출구에 의한 유동패턴에 관한 수치해석)

  • Kim, Nam-Hyeong;Lee, Chang-Lym;Ku, Bon-Soo;Song, Man-Soon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.1
    • /
    • pp.43-49
    • /
    • 2011
  • For the improvement of water quality in a harbor, several studies have been carried out on SEB (Seawater Exchange Breakwater) in recent years, but a problem has been shown whereby the water on the inside area far from the SEB cannot be easily exchanged. In order to solve the problem of the SEB, the Manifold channel, a new concept of the SEB, is introduced in this paper. By using the manifold channel, it is possible to exchange the water of the inside area for seawater from the outside. Here, to assess the outflow gates of the manifold channel governing flow behavior, a virtual manifold channel controlled the location, width and direction of outflow gates applied to the Jumunjin fishery port, where the SEB has been established. In addition, the desirable flow pattern of the port by utilizing the two layer current model is identified, and five general cases of the manifold channel are described in this paper. The model is verified by comparing with observation of the SEB model, and the results are in general agreement. From the results of the manifold channel, in the case of the Jumunjin fishery port, the small circulation of counter clockwise is necessary for the water exchange on the inside area, but it should be controlled by the outflow gates for other areas. Using the two layer current model, the desirable flow pattern of the port can be predicted, and the water exchange for the upper and lower layer can be examined. For the practical use of the manifold channel, further studies on the manifold channel will be necessary, and it may then be used broadly for the design of breakwater in the future.

Development of a Dynamic Deformable Rubber Membrane Parapet to Cope with the Long Term Sea Level Rise and the Abnormal Waves (장기해수면 상승 및 이상파랑에 대비한 동적 가변형 고무막체 파라펫 개발)

  • Kim, Sun-Sin;Chun, In-Sik;Lee, Young-Gun;Ko, Jang-Hee;Hong, Seung-Ik
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.1
    • /
    • pp.34-42
    • /
    • 2011
  • It's been reported that the global warming effect has invoked the ever increasing typhoon intensity and long-term sea level rise which jointly cause severe wave overtopping over breakwaters or shore dykes. A simple measure to cope with this undesirable change may be just to increase the crest height of the dykes and breakwaters. This is surely effective to prevent wave overtopping, but it also decreases the seaward visibility of coastal waterfront. In this paper, a dynamic deformable rubber membrane parapet which not only reduces wave overtopping in storm period but also secures seascapes in normal days is presented. Several optimal configurations of the parapet are proposed. Through numerical analyses using a nonlinear finite element model and hydraulic experiments, the air controlled expansion and contraction of the parapets, their behavior against wave overtopping and structural stability are investigated.

Joint Displacement Resistance Evaluation of Waterproofing Material in Railroad Bridge Deck (철도교량상판 방수재료 선정을 위한 균열거동저항 성능평가)

  • Bae, Young-Min;Oh, Dong-Cheon;Park, Yong-Gul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.683-692
    • /
    • 2020
  • A joint displacement resistance evaluation method for selecting waterproofing materials in railway bridge decks is proposed. The displacement range for an evaluation is determined by finite element method (FEM) analysis of a load case based on an existing high-speed PSC Girder Box railroad bridge structure. The FEM analysis results were used to calculate the minimum joint displacement range to be applied during testing (approximately 1.5 mm). For the evaluation, four commonly used waterproofing membrane types, cementitious slurry coating (CSC), polyurethane coating system (PCS), self-adhesive asphalt sheet (SAS), and composite asphalt sheet (CAS), were tested, with five specimens of each membrane type. The joint displacement width range conditions, including the minimum displacement range obtained from FEM analysis, were set to be the incrementing interval, from 1.5, 3.0, 4.5, and 6.0 mm. The proposal for the evaluation criteria and the specimen test results demonstrated how the evaluation method is important for the sustainability of high-speed railway bridges.

Development of a Short-term Failure Assessment of High Density Polyethylene Pipe Welds - Application of the Limit Load Analysis - (고밀도 폴리에틸렌 융착부에 대한 단기간 파손 평가법 개발 - 한계하중 적용 -)

  • Ryu, Ho-Wan;Han, Jae-Jun;Kim, Yun-Jae;Kim, Jong-Sung;Kim, Jeong-Hyeon;Jang, Chang-Heui
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.4
    • /
    • pp.405-413
    • /
    • 2015
  • In the US, the number of cases of subterranean water contamination from tritium leaking through a damaged buried nuclear power plant pipe continues to increase, and the degradation of the buried metal piping is emerging as a major issue. A pipe blocked from corrosion and/or degradation can lead to loss of cooling capacity in safety-related piping resulting in critical issues related to the safety and integrity of nuclear power plant operation. The ASME Boiler and Pressure Vessel Codes Committee (BPVC) has recently approved Code Case N-755 that describes the requirements for the use of polyethylene (PE) pipe for the construction of Section III, Division 1 Class 3 buried piping systems for service water applications in nuclear power plants. This paper contains tensile and slow crack growth (SCG) test results for high-density polyethylene (HDPE) pipe welds under the environmental conditions of a nuclear power plant. Based on these tests, the fracture surface of the PENT specimen was analyzed, and the fracture mechanisms of each fracture area were determined. Finally, by using 3D finite element analysis, limit loads of HDPE related to premature failure were verified.

Internal Confining Stress of Internally Confined Hollow Columns under Compressive Load (압축을 받는 내부 구속 중공 RC 기둥의 내부 구속력)

  • Won, Deok Hee;Han, Taek Hee;Kim, Seungjun;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.3
    • /
    • pp.243-254
    • /
    • 2013
  • Internally Confined Hollow RC(ICH RC) column consisted of concrete, transverse reinforcement, longitudinal reinforcement, and inner tube. It had good strength and ductility by core concrete was become triaxial confining state with transverse reinforcement and inner tube. There were two confining stress as external confining stress and internal confining stress in an ICH RC column. While external confining stress was researched by former researchers, internal confining stress has not researched. In this paper, confining stress of both Hollow RC column and ICH RC column was investigated using FEA program. Relation between theoretical confining stress and internal confining stress was drawn by analysis results. Modified failure condition equations of inner tube were suggested to base on failure condition equations of inner tube by former researcher. When thickness of inner tube was calculated by modified equations, it could be economic because thickness of inner tube was reduced 50% compared with former researcher equations in order to same confining stress.

Analysis of Compression Behavior on Intervertebral Disc L4-5 in Pedicle Screw System Instrumented Lumbar Spine under Follower Load (척추경 나사못을 이용한 척추 유합술에서 고정범위에 따른 인접 추간판의 압축 거동 분석)

  • Ahn, Myun-Whan;Ahn, Jong-Chul;Lee, Su-Ho;Chung, Il-Sub;Lee, Choon-Yeol;Lee, Jang-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.20 no.2
    • /
    • pp.160-168
    • /
    • 2003
  • Background: Confirm the stability of intervertebral disc sustaining each fused lumbar spine cases, comparing vertical compression, A-P shear force and rotational moment on intervertebral disc of instrumented lumbar spine with simple vertical compression load and follower load using finite element analysis. Materials and Methods: We analyze the stability of intervertebral disc L4-5 supporting fused lumbar spine segments. After performing finite element modelling about L1-L5 lumbar vertebral column and L1-L4 each fusion level pedicle screw system for fused lumbar spine fine element model. Intervertebral discs with complex structure and mechanical properties was modeled using spring element that compensate stiffness and tube-to-tube contact element was employed to give follower load. Performing geometrical non-linear analysis. Results: The differences of intervertebral disc L4-5 behavior under the follower compression load in comparision with vertical compression load are as follows. Conclusion: As a result of finite element interpretation of instrumented lumbar spine, the stability of L4-5 sustaining fused lumbar segment, the long level fused lumbar spine observed hing stability under follower load. This research method can be the basis tool of effects prediction for instrumentation, a invention of a more precious finite element interpretation model which consider the role of muscle around the spine is loaded.

  • PDF

A Study on the Improvement of Operation Performance of Wet Bell Diving System in the Salvage Ship (고장 사례 분석을 통한 수중함용 디젤엔진 건전성에 관한 연구)

  • Choi, Woo-Suk;Min, Tae-Kyu;Kim, Byeong-Ho;Chang, Ho-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.98-106
    • /
    • 2020
  • This study examined the integrity of diesel engines for underwater vessels through failure analysis, analyzed the causes of abnormal diesel engine stoppage during building and examined the integrity of secondary damages. The diesel engine stoppage was analyzed by checking the temperature change of the piston before and after the abnormality and checking the damage. In addition, in order to analyze the secondary damage caused by the explosion, the tensile and compressive stresses transmitted to the crankshaft, the core part of the diesel engine, were calculated, and the stress distribution was examined through finite element analysis, but the crankshaft was designed by safety. It was confirmed that there was no damage to the crankcase even when the diesel engine was taken out of the ship and closely inspected. The integrity of the crank shaft was verified in advance for the occurrence of diesel engine emergency shutdown accidents through this research result. Therefore, the inspection and restoration were carried out to the minimum extent, and the quality of diesel engines was secured. This study is expected to be used as a reference for ensuring soundness in any future review of diesel engine quality problems.