• Title/Summary/Keyword: 유순도

Search Result 393, Processing Time 0.027 seconds

Effects of Environmental Factors on Phytoplankton Succession and Community Structure in Lake Chuncheon, South Korea (환경요인이 춘천호의 식물플랑크톤 천이 및 군집구조에 미치는 영향)

  • Baek, Jun-Soo;Youn, Seok-Jea;Kim, Hun-Nyun;Sim, Youn-Bo;Yoo, Soon-Ju;Im, Jong-Kwon
    • Korean Journal of Ecology and Environment
    • /
    • v.52 no.2
    • /
    • pp.71-80
    • /
    • 2019
  • Effects of environmental factors on phytoplankton succession and community structure were studied in Lake Chuncheon located in Bukhan River, South Korea. The data were sampled at three sites such as CC1 (lower side), CC2 (middle side), and CC3 (upper side of Lake Chuncheon) from 2014 to 2017. The annual average precipitation in Lake Chuncheon was 992 mm during the study period (2014~2017), and the annual precipitation was lower than 800 mm in 2014 and 2015. The annual average water temperature, total phosphorus (TP), and total nitrogen (TN) ranged from 17.0 to $21.1^{\circ}C$, 0.012 to $0.019mg\;L^{-1}$, and 1.272 to $1.922mg\;L^{-1}$, respectively. The TN concentration was relatively high in 2015 compared with the other study years, as a drought continued from 2014 to 2015. When comparing the correlation between precipitation and environmental factors, water temperature (p<0.01) and TP(p<0.05) showed positive correlations with rainfall. The average numbers of phytoplankton cells by branch were 2,094, 2,182, and $3,108cells\;mL^{-1}$ in CC1, CC2, and CC3, respectively. CC3 is considered advantageous for phytoplankton growth, even in small pollution sources due to low water depth. As a result of analyzing the relationship between precipitation and phytoplankton, the correlation between the two was shown to be high for 2016 (p<0.01) and 2017 (p<0.05), which is when precipitation was high. However, the correlation was not clear to 2014 and 2015. The relationship between water temperature and phytoplankton indicated a negative correlation with diatoms (p<0.01), yet positive correlations with green algae (p<0.01) and cyanobacteria (p<0.01). Diatoms increased in spring and autumn, which are characterized by low water temperature, and green algae and cyanobacteria increased in summer, when the water temperature is high. Our findings provide a scientific basis for characteristics of phytoplankton and water quality and management at the Lake Chuncheon.

A Study on Superficial Dose of 6MV-FFF in HalcyonTM LINAC: Phantom Study (HalcyonTM 선형가속기 6MV-FFF 에너지의 표재 선량에 대한 고찰: Phantom Study)

  • Choi, Seong Hoon;Um, Ki Cheon;Yoo, Soon Mi;Park, Je Wan;Song, Heung Kwon;Yoon, In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.31-39
    • /
    • 2020
  • Purpose: The aims of this study were to compare the superficial dose with Optically Stimulated Luminescence Dosimeter(OSLD) measurement and Treatment Planning System(TPS) calculation for 6MV-Flattening Filter Free(FFF) energy using HalcyonTM and TrueBeamTM. Materials and methods: Phantom study was performed using the CT images of human phantom. In the treatment planning system, the Planning Target Volume(PTV) was contoured which is similar to Glottic cancer. Furthermore, Point(M), Point(R), and Point(L) were contoured at the iso-center of head and neck region and 5mm bolus was applied to the body contour. Each treatment plans using 6MV-FFF energy from HalcyonTM and TrueBeamTM with static Intensity Modulated Radiation Therapy(IMRT) and Volumetric Modulated Arc Therapy(VMAT) were established with eclipse. To reproduce the same position as the TPS, OSLDs were placed at the iso-center point and 5mm bolus was applied to compare the error rate after the dose delivery. Result: The results of the study using human phantom are as follows. In case of HalcyonTM, the mean absolute error rates of the point dose using the treatment planning system and the dose measured by OSLD were 1.7%±1.2% for VMAT and 4.0±2.8% for IMRT. Also TrueBeamTM was identified as 2.4±0.4% and 8.6±1.8% respectively for VMAT and IMRT. Conclusion: Through the results of this study, TrueBeamTM confirmed that the average error rate was 2.4 times higher for VMAT and 3.6 times higher for IMRT than HalcyonTM. Therefore, based on the results of this study, If we need a more accurate dose assessment for the superficial dose, It is expected that using HalcyonTM would be better than TrueBeamTM.

A study on the impact and activation plan of unmanned aerial vehicle service (무인항공기 서비스 영향성과 활성화 방안 연구)

  • Yoo, Soonduck
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.2
    • /
    • pp.1-7
    • /
    • 2022
  • The purpose of this study is to discuss the impact of unmanned aerial vehicle service and how to activate it. The discussion on the impact of the introduction of the unmanned aerial vehicle service was examined in terms of economic, environmental, and social acceptance, and a plan to revitalize the industry was presented. In terms of economic impact, if transportation services are increased using unmanned aerial vehicles in the future, road-based transportation cargo may decrease and road movement speed may increase due to reduced road congestion. This can have a positive effect on the increase in the value of land or real estate assets, and it also provides an impact on smart city design. In terms of environmental impact, unmanned aerial vehicles (UAVs) generally move through electricity, so they emit less exhaust gas compared to other existing devices, such as vehicles and railroads, and thus have less environmental impact. However, noise can have a negative impact on the habitat in the presence of wild animals along their migration routes. In terms of social acceptability of unmanned aerial vehicles (UAV) technology, areas that are declining due to the emergence of new services may appear, and at the same time, organizations that create profits may appear, causing conflicts between industries. Therefore, it is essential to form a social consensus on the acceptance of emerging industries. The government should come up with various countermeasures to minimize the negative impact that reflects the characteristics of the unmanned aerial vehicle use service. Just as various systems such as road signs were introduced so that vehicles can be operated on the ground to secure air routes in the mid- to long-term for revitalization of unmanned-based industries, development and establishment of services that should be introduced and applied prior to constructing air routes I need this. In addition, the design and implementation of information collection and operation plans for unmanned air traffic management in Korea and a plan to secure a control system for each region should also be made. This study can contribute to providing ideas for mid- to long-term research on new areas with the development of the unmanned aerial vehicle industry.

Evaluation of the usefulness of the method according to changes in patient breathing during chest 4D CT imaging (흉부 4D CT에서 호흡 변화에 대한 일시 중지 및 재개 방법의 유용성 평가)

  • Heo, Sol;Shin, Chung Hun;Jeong, Hyun Sook;Yoo, Soon Mi;Kim, Jeong Mi;Yun, In Ha;Hong, Seung Mo;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.47-54
    • /
    • 2021
  • Purpose : In order to evaluate the usefulness of clinical application of the Pause & Resume methods by comparing and analyzing the data stability and dose reduction effect when repeat scan assuming irregular breathing and using the Pause & Resume method during chest 4D CT using QuasarTM Phantom. Materials and Methods : Using the QuasarTM Phantom, set the breathing rate per minute to 15 BPM and 7.5 BPM, and set the S15 point as an irregular breathing section, and then placed OSLD to this point and use the Pause & Resume method to measure the dose of S15. CTDIvol, DLP, and ALARA-CT were used for comparative analysis of radiation dose between Pause & Resume method and Repeat-scan. In order to evaluate the stability and usability of the data applying the Pause & Resume method, the captured images were sorted by Advanced Workstation Volume Share7 and then sent to EclipseTM, the diameter and volume were analyzed by forming a contour on the iron ball in the QuasarTM Phantom Results : When using Pause & Resume, the dose of OSLD measurement increased by 1.97 times in the section of S15. As a result of image evaluation, the average value of all volumes measured with and without the Pause & Resume method at 15 BPM and 7.5 BPM was 15.2 cm3±0.5%.Allthemeasuredvaluesfor the radius of iron ball were 3.1 cm regardless of whether Pause & Resume method was used or not. In the case of using Pause & Resume, 33% decreased from the lowest DLP value and 38% decreased from the highest DLP value of repeat scan, and the effective dose also decreased 32.1% from the minimum value and 37.6% from the maximum value. Conclusion: Irradiation dose was increased by Pause & Resume method because of the repeat scan on the S15 site where assuming irregular breathing occurred, However Pause & Resume method led to a significant reduction in dose on overall scan range. It also proved the usefulness of clinical application of the Pause & Resume method as a result of similar diameters and volumes of iron ball measurement.

Status and Implications of Hydrogeochemical Characterization of Deep Groundwater for Deep Geological Disposal of High-Level Radioactive Wastes in Developed Countries (고준위 방사성 폐기물 지질처분을 위한 해외 선진국의 심부 지하수 환경 연구동향 분석 및 시사점 도출)

  • Jaehoon Choi;Soonyoung Yu;SunJu Park;Junghoon Park;Seong-Taek Yun
    • Economic and Environmental Geology
    • /
    • v.55 no.6
    • /
    • pp.737-760
    • /
    • 2022
  • For the geological disposal of high-level radioactive wastes (HLW), an understanding of deep subsurface environment is essential through geological, hydrogeological, geochemical, and geotechnical investigations. Although South Korea plans the geological disposal of HLW, only a few studies have been conducted for characterizing the geochemistry of deep subsurface environment. To guide the hydrogeochemical research for selecting suitable repository sites, this study overviewed the status and trends in hydrogeochemical characterization of deep groundwater for the deep geological disposal of HLW in developed countries. As a result of examining the selection process of geological disposal sites in 8 countries including USA, Canada, Finland, Sweden, France, Japan, Germany, and Switzerland, the following geochemical parameters were needed for the geochemical characterization of deep subsurface environment: major and minor elements and isotopes (e.g., 34S and 18O of SO42-, 13C and 14C of DIC, 2H and 18O of water) of both groundwater and pore water (in aquitard), fracture-filling minerals, organic materials, colloids, and oxidation-reduction indicators (e.g., Eh, Fe2+/Fe3+, H2S/SO42-, NH4+/NO3-). A suitable repository was selected based on the integrated interpretation of these geochemical data from deep subsurface. In South Korea, hydrochemical types and evolutionary patterns of deep groundwater were identified using artificial neural networks (e.g., Self-Organizing Map), and the impact of shallow groundwater mixing was evaluated based on multivariate statistics (e.g., M3 modeling). The relationship between fracture-filling minerals and groundwater chemistry also has been investigated through a reaction-path modeling. However, these previous studies in South Korea had been conducted without some important geochemical data including isotopes, oxidationreduction indicators and DOC, mainly due to the lack of available data. Therefore, a detailed geochemical investigation is required over the country to collect these hydrochemical data to select a geological disposal site based on scientific evidence.

Research on the Digital Twin Policy for the Utilization of Administrative Services (행정서비스 활용을 위한 디지털 트윈 정책 연구)

  • Jina Ok;Soonduck Yoo;Hyojin Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.3
    • /
    • pp.35-43
    • /
    • 2023
  • The purpose of this study is to research digital twin policies for the use of administrative services. The study was conducted through a mobile survey of 1,000 participants, and the results are as follows. First, in order to utilize digital twin technology, it is necessary to first identify appropriate services that can be applied from the perspective of Gyeonggi Province. Efforts to identify digital twin services that are suitable for Gyeonggi Province's field work should be prioritized, and this should lead to increased efficiency in the work. Second, Gyeonggi Province's digital twin administrative services should prevent duplication with central government projects and establish a model that can be connected and utilized. It should be driven around current issues in Gyeonggi Province and the demands of citizens for administrative services. Third, to develop Gyeonggi Province's digital twin administrative services, a standard model development plan through participation in pilot projects should be considered. Gyeonggi Province should lead the project as the main agency and promote it through a collaborative project agreement. It is suggested that a support system for the overall project be established through the Gyeonggi Province Digital Twin Advisory Committee. Fourth, relevant regulations and systems for the construction, operation, and management of dedicated departments and administrative services should be established. To achieve the realization of digital twins in Gyeonggi Province, a dedicated organization that can perform various roles in project promotion and operation, as well as legal and institutional improvements, is necessary. To designate a dedicated organization, it is necessary to consider expanding and reorganizing existing departments and evaluating the operation of newly established departments. The limitation of this study is that it only surveyed participants from Gyeonggi Province, and it is recommended that future research be conducted nationwide. The expected effect of this study is that it can serve as a foundational resource for applying digital twin services to public work.

Estimation of Structural Deterioration of Sewer using Markov Chain Model (마르코프 연쇄 모델을 이용한 하수관로의 구조적 노후도 추정)

  • Kang, Byong Jun;Yoo, Soon Yu;Zhang, Chuanli;Park, Kyoo Hong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.421-431
    • /
    • 2023
  • Sewer deterioration models can offer important information on prediction of future condition of the asset to decision makers in their implementing sewer pipe networks management program. In this study, Markov chain model was used to estimate sewer deterioration trend based on the historical structural condition assessment data obtained by CCTV inspection. The data used in this study were limited to Hume pipe with diameter of 450 mm and 600 mm in three sub-catchment areas in city A, which were collected by CCTV inspection projects performed in 1998-1999 and 2010-2011. As a result, it was found that sewers in sub-catchment area EM have deteriorated faster than those in other two sub-catchments. Various main defects were to generate in 29% of 450 mm sewers and 38% of 600 mm in 35 years after the installation, while serious failure in 62% of 450 mm sewers and 74% of 600 mm in 100 years after the installation in sub-catchment area EM. In sub-catchment area SN, main defects were to generate in 26% of 450 mm sewers and 35% of 600 mm in 35 years after the installation, while in sub-catchment area HK main defects were to generate in 27% of 450 mm sewers and 37% of 600 mm in 35 years after the installation. Larger sewer pipes of 600 mm were found to deteriorate faster than smaller sewer pipes of 450 mm by about 12 years. Assuming that the percentage of main defects generation could be set as 40% to estimate the life expectancy of the sewers, it was estimated as 60 years in sub-catchment area SN, 42 years in sub-catchment area EM, 59 years in sub-catchment area HK for 450 mm sewer pipes, respectively. For 600 mm sewer pipes, on the other hand, it was estimated as 43 years, 34 years, 39 years in sub-catchment areas SN, EM, and HK, respectively.

Image quality and usefulness evaluaton of 3D-CBCT and Gated-CBCT according to baseline changes for SBRT of Lung Cancer (폐암 환자의 정위체부방사선치료 시 기준선 변화에 따른 3D-CBCT(Cone Beam Computed-Tomography)와 Gated-CBCT의 영상 품질 및 유용성 평가)

  • Han Kuk Hee;Shin Chung Hun;Lee Chung Hwan;Yoo Soon Mi;Park Ja Ram;Kim Jin Su;Yun In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.41-51
    • /
    • 2023
  • Purpose: This study compares and analyzes the image quality of 3D-CBCT(Cone Beam Computed-Tomography) and Gated CBCT according to baseline changes during SBRT(Stereotactic Body RadioTherapy) in lung cancer patients to find a useful CBCT method for correcting movement due to breathing Materials and methods : Insert a solid tumor material with a diameter of 3 cm into the QUASARTM phantom. 4-Dimentional Computed-Tomography(4DCT) images were taken with a speed of the phantom at period 3 sec and a maximum amplitude of 20 mm. Using the contouring menu of the computerized treatment planning system EclipseTM Gross Tumor Volume was outlined on solid tumor material. Set-up the same as when acquiring a 4DCT image using Truebeam STxTM, breathing patterns with baseline changes of 1 mm, 3 mm, and 5 mm were input into the phantom to obtain 3D-CBCT (Spotlight, Full) and Gated-CBCT (Spotlight, Full) images five times repeatedly. The acquired images were compared with the Signal-to-Noise Ratio(SNR), Contrast-to-Noise Ratio(CNR), Tumor Volume Length, and Motion Blurring Ratio(MBR) based on the 4DCT image. Results: The average Signal-to-Noise Ratio, Contrast-to-Noise Ratio, Tumor Volume Length and Motion Blurring Ratio of Spotlight Gated CBCT images were 13.30±0.10%, 7.78±0.16%, 3.55±0.17%, 1.18±0.06%. As a result, Spotlight Gated-CBCT images according to baseline change showed better values than Spotligtht 3D-CBCT images. Also, the average Signal-to-Noise Ratio, Contrast-to-Noise Ratio, Tumor Volume Length and Motion Blurring Ratio of Full Gated CBCT images were 12.80±0.11%, 7.60±0.11%, 3.54±0.16%, 1.18±0.05%. As a result Full GatedCBCT images according to baseline change showed better values than Full 3D-CBCT images. Conclusion : Compared to 3D-CBCT images, Gated-CBCT images had better image quality according to the baseline change, and the effect of Motion Blurring Artifacts caused by breathing was small. Therefore, it is considered useful to image guided using Gated-CBCT when a baseline change occurs due to difficulty in regular breathing during SBRT that exposes high doses in a short period of time

  • PDF

Utilization of Phosphorus and Nitrogen Fertilizers by Paddy Rice -A six years internationally coordinated study using isotopes- (수도(水稻)에 대(對)한 인산(燐酸) 및 질소질비료(窒素質肥料)의 효용에 관(關)한 연구(硏究) -동위원소(同位元素)를 이용(利用)한 6 개년간(個年間)의 국제적(國際的) 공동시험결과(共同試驗結果)-)

  • Kim, H.S.;Cho, B.H.;Lee, C.Y.;Lee, E.W.;Shim, S.C.;Yoo, S.H.;Kwon, Y.W.;Jo, J.S.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.1 no.1
    • /
    • pp.13-26
    • /
    • 1968
  • To establish the most efficient method of nitrogen and phosphorus fertilization in paddy rice a series of internationally coordinated research using $N^{15}\;P^{32}$ isotopes were carried out from the year 1962 through 1967, supervised by the Joint FAO/IAEA Division of Atomic Energy in Agriculture under the auspicies of FAO, UN. In Korea College of Agriculture, Seoul National University had been participated in the Coordinated Research Programme from the year 1963 through the last year, arid the results obtained through the six years' researches are summarized as follows: 1. In the application of superphosphate broadcasting or placement at the surface of paddy as basal dressing was most efficient. 2. Split or late application of superphosphate did not affect the grain yield of the rice, but its efficiency in the rice plant uptake was less than in the case of basal dressing of whole amounts. 3. The contents of available soil phoshorus of the experimental sites in Korea were above 60 ppm, and the efficiency of phosphorus utilization of the rice from the fertilizer was approximately 10 per cent. The grain yield response of the rice to phosphorus application in Korea was rather small comparing to those of other countries. 4. The nitrogen uptake of the rice plants from the fertilizer was most efficient when the fertilizer was applied at the time of ear prime growth. However, the most efficient utilization of nitrogen did not necessarily accompany the maximum yield of the rice and basic application of adequate amount of nitrogen was required to secure proper number of panicles. 5. In the application of nitrogenous fertilizer shallow placement at 5 cm depth was most efficient. The effect of split application of nitrogen was not so noticeable. It seemed due to the fact that total application amount of nitrogen, 60 kg N/ha, was smaller than that of usual dosage in Korea. 6. The efficiency of nitrogen utilization of the rice from the fertilizer was about 40 percent in Korea, and the yield reponse of the rice plant to nitrogen application was remarkable comparing to those of other countries, showing the marked differences in the fertilizer efficiency and grain yield according to the application method. 7. The nitrogen uptake of the rice plant was not likely affected by the time and the rate of phosphorus application whereas the efficiency of phosphorus utilization was affected to some degree by the method of nitrogen application.

  • PDF

Potassium Availability and Physical Properties of Upland Soils (밭토양(土壤)의 물리성(物理性)과 가리(加里))

  • Yoo, S.H.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.10 no.3
    • /
    • pp.189-201
    • /
    • 1977
  • Some of basic aspects of soil potassium with special reference to soil physical properties were discussed. Data in the Official Soil Series Description(Korea) was analyzed according to soil type, land form, and soil texture to find soil potassium status which may explain different response to potassium application. Exchangeable potassium contents decreased with soil depth irrespective of soil type, land form and soil texture. Change in degree of potassium saturation within soil profile was not so clear as exchangeable potassium but the degree of potassium saturation of A horizon was highest among soil horizon. Soils of terrace and mountain foot slope showed high values both in exchangeable potassium and degree of potassium sauration and only these two soils were classified as soils having exchangeable potassium higher than 0.3 meq per 100g of soil and degree of potassium saturation higher than 5.0%. Exchangeable potassium of fine loamy and fine clayey soils is higher than 0.3 meq per 100g of soil but degree of potassium saturation is lower than 4.0%. Degree of potassium saturation of sandy soils exceeds 5.0% but exchangeable potassium is very low. Soils of rolling, hilly, unmatured and alpine land soils have lower exchangeable potassium and show lower degree of potassium saturation. The highest distribution of exchangeable potassium content irrespective of soil horizons was shown in the range of 0.1-0.2 meq per 100g of soil. The highest distribution of degree of potassium saturation was in the range of 2.0-3.0% in A horizon and 1.0-2.0% in B and C horizons. Of the soil series concerned in this analysis, 27.3% in A horizon, 11.1% in B horizon and 4.0% in C horizon had exchangeable potassium higher than 0.3 meq per 100g of soil and 18.0% in A horizon, 6.3% in B horizon, and 4.1% in C horizon showed degree of potassium saturation higher than 5.0%. The low response of potassium application only to soils in terrace and mountain foot slope may be resulted from the high exchangeable potassium content and high degree of potassium saturation. It is concluded that a great response of potassium application to soils is expected especially in dry season.

  • PDF