• Title/Summary/Keyword: 유속 감소율

Search Result 154, Processing Time 0.029 seconds

An Experimental Study of Film Cooling Characteristics at Supersonic Free Stream Conditions (초음속 주유동 환경에서의 막냉각 특성 시험 연구)

  • Kim, Manshik;Lee, Dong Min
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.4
    • /
    • pp.342-348
    • /
    • 2017
  • In this paper, film cooling characteristics at supersonic free stream conditions were examined experimentally by applying an IR-thermography. Film cooling experiments were carried out in a free-jet facility at Mach number of 3.0 and with unit Reynolds number of $42.53{\times}10^6$ and $69.35{\times}10^6$ using wedge shaped film cooling model which has a converging film cooling nozzle. Film cooling efficiency was calculated by measuring the surface temperature of PEEK(Polyether Ether Ketone) and the effects of angle of attack and blowing ratios on the film cooling efficiency were examined. The measured wall temperature was significantly reduced by the film cooling flow compared with the results without the film cooling flow. The usefulness of film cooling was also confirmed by the surface heat flux calculated using the surface temperature history of PEEK. As the blowing ratio increases the protected area of PEEK was also expanded along the direction of free stream and film cooling flow.

Firing Test for Hybrid Rocket Motor with 650 kgf Thrust Level (추력 650 kgf 급 하이브리드 로켓 모터의 연소시험)

  • Lee, Jung-Pyo;Kim, Soo-Jong;Kim, Gi-Hun;Cho, Jung-Tae;Kim, Hak-Chul;Woo, Kyong-Jin;Do, Gyu-Sung;So, Jung-Soo;Oh, Jung-Soo;Cho, Min-Gyung;Moon, Hee-Jang;Sung, Hong-Gye;Kim, Jin-Kon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.503-506
    • /
    • 2009
  • In this study, we presented the results of static firing tests on the PE/LN2O hybrid rocket motor, which has a thrust of 650 kgf level. Through the early tests, we found that the combustion chamber pressure and the thrust were lower than design values because an actual oxidizer flow rate was less than that expected. In order to complement this result, the methods of decrease of nozzle throat and the increase of oxidizer mass flow rate were conducted in the next experiment, and we studied the combustion phenomena with the experimental results. Also we compared and analyzed a difference of combustion characteristics on scale effect. It show that a sub-scale motor regression rate was a little less than that of a lab-scale motor with the same oxidizer mass flux. Results of this study might be used as a basic data for development of hybrid sounding rocket.

  • PDF

Case Study on Construction of Small Washland (천변 아지늪 조성 사례 연구)

  • Kim, Ki-Heung;Lee, Hyeong-Rae;Shin, Yeoung-Cheol;Kim, Young-Taek;Jung, Hae-Ryen
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1003-1007
    • /
    • 2007
  • 최근 기상이변, 불투수층의 증가와 배수체계개선 등의 요인으로 인한 홍수량의 증대로 하도방어 위주의 현재 홍수방어체제는 지속적인 치수사업의 시행에도 불구하고 오히려 하류에서의 홍수가 격심해지는 등 상당한 어려움에 직면하고 있다. 따라서 최근의 유역종합치수계획에서는 천변저류지 등에 의한 면적 개념의 2차원적 홍수량 분담을 통한 피해의 잠재성을 경감시키고자 하는 방안들이 제시되고 있다. 이러한 기술적 수요의 증가에 따라 낙동강유역종합치수계획, 삽교천유역종 합치수계획 등에서는 중규모 이상의 천변저류지가 검토되었지만 이러한 예는 대하천유역이므로 홍수피해가 빈발하는 농촌지역의 중소규모 하천에서는 계획된 적이 없다. 지금까지 지속적인 하천개수사업으로 2004년말 현재 하천연장 기준으로 전국의 하천 개수율은 78%에 이르고 있다. 이 중 국가하천과 지방1급하천은 약 15%로서 개수율이 약 90%이상으로 높고, 지방2급하천은 약 85%를 차지하나 대부분은 농촌지역에 위치하여 약 70% 미만의 낮은 개수율을 나타내고 있으므로 향후 중소규모유역의 지방2급하천에서 하천개수가 지속적으로 추진될 것이다. 현재 하천정비기본계획이 미수립된 하천구간에 대하여 하도계획시 제방축제에 의한 경제성이 미미한 일부 구간에 무제부의 소규모 아지늪을 조성하고, 홍수파의 전파속도를 저감하여 하류의 홍수집중을 경감시키고 유수 에너지를 감소시키며 아울러 본천의 유수환경과는 다른 습지로서의 정수환경을 창출하여 하천생태계의 다양성을 확보하는 방안도 있을 것이다. 본 연구에서는 경남 하동군에 위치하는 지방2급하천인 주교천에 약 $4000m^2$의 소형 습지(아지늪)를 2004년 3월에 조성하고 2006년 11월에 습지의 어류 및 수생식물에 대한 모니터링을 실시하여 아지늪의 하천생태의 다양성의 달성도를 평가하였다. 또한 주교천에서 홍수량의 증가에 따른 홍수류의 유속 변동과 그에 따른 에너지의 변화를 고찰하기 위하여 HEC-RAS를 적용하고 주교천 아지늪 주변의 수리학적 거동을 고찰하였다.

  • PDF

Analysis of Inundation Pattern of Excavation Site Using Hydrodynamic Model (동수역학 모델을 이용한 굴착공사 현장 침수 양상 해석)

  • Yoo, Dong Hyun;Lee, Ka Young;Sim, Ye Jin;Song, Chang Geun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.300-300
    • /
    • 2020
  • 최근 전체 산업재해율은 계속적으로 감소 추세를 보이는 반면, 건설업의 재해율은 증가하는 추세를 내타내고 있다. 이러한 건설업 공종별 재해유형은 임시구조물과 관련된 가설공, 굴착공, 철근콘크리트공의 재해율이 타 공종에 비해 높게 나타난다. 이는 공종 진행에 따라 변화되는 건설현장의 위험요소를 사전에 인지하여 제어·관리할 수 있는 사고예측 기술 및 대응 기술의 부재로 안전사고가 높게 발생한 것으로 판단된다. 이러한 상황 속에서 건설현장에서 빈번하게 발생하는 다양한 재해 상황에 대하여 공사별, 규모별, 공정별 대응 체계를 마련하고, 굴착공사 중 침수 발생 시 피해를 최소화할 수 있는 실용적인 긴급대응 방안을 확보함으로써 경제적인 손실뿐만 아니라 인명피해를 최소화하는 방안 마련이 필요하다. 공사 현장 재해 상황 중 침수는 태풍 또는 집중호우 시 공사구간이 침수되어 근로자 수몰 등의 피해가 발생하고, 절토면이 붕괴되는 등 2차적인 피해로 이어진다. 이러한 침수의 원인은 공사 현장의 저지대 위치, 집중호우 시 최대 강우량에 대한 대비 소홀, 양수기 부족 및 고장, 인접 배수로 배수기능 불량 등의 복합적인 원인들로 인하여 발생한다. 또한 굴착공사 현장의 침수는 공사기간 동안 개별 공종에 따라 침수발생 양상이 달라질 수 있다. 따라서 각 공종별 발생 가능한 침수 양상에 대한 예방/대응 기술이 필요하다. 본 연구에서 사용되는 HDM-2D 수리 동역학 모델은 2차원 흐름해석 프로그램으로 복잡한 하천지형이나 공사현장과 같은 불연속면에서 유속 및 수심 등을 계산한다. 또한 마름/젖음 현상 등 복잡한 수리현상에 대한 정교한 모의 기능 및 침수해석 등 어떠한 계산영역이나 흐름조건에서도 정확하고 안정적인 모의를 할 수 있다. 본 연구에서는 공사현장과 같은 불연속면에서 각 공종에 따라 발생할 수 있는 침수양상에 대한 모의를 진행하고 각 공종별 침수양상을 비교분석 하였다. 이를 통해서 굴착공사 현장 침수피해 예측 모델을 개발하여 개발된 기술을 사용하여 기후변화에 따른 강우량 증가와 이에 따른 수재해로 인한 건설현장 침수 발생 및 인명, 재산피해를 최소화하고자 한다.

  • PDF

Numerical study on flow characteristics at dividing open-channel with changing bifurcation angle using TELEMAC-2D (TELEMAC-2D모형을 이용한 분류각 변화에 따른 개수로 흐름특성변화 수치모의 연구)

  • Jung, Daejin;Jang, Chang-Lae;Jung, Kwansue
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.8
    • /
    • pp.617-626
    • /
    • 2020
  • This study investigates changes of bifurcation discharge ratio, flow velocity distributions and characteristics of separation zone due to variation of bifurcation angle by using TELEMAC-2D model. When the bifurcation angle is reduced from 90° to 45° without changing the boundary conditions, the bifurcation discharge ratio increased by 1.5 times from 0.523 to 0.785 because of increasing the radius of curvatures, the inertia force of the downstream flow, and the pressure gradient by the downstream boundary conditions. The bifurcation discharge ratio increases non-linearly whenever the bifurcation angle decreases by 15° intervals from 90° to 45° in flow with the upstream Froude number of 0.45 to 0.74. In flow with a maximum Froude number of 0.74, the rate of increase for bifurcation discharge ratio is 31.1% and the minimum value. When the Froude number is 0.58, the bifurcation discharge ratio is 0.7 or less, and the maximum rate of increase for that ratio is 53.5%. As the upstream Froude number decreases less than 0.58, the bifurcation discharge ratio exceeds 0.7, and the rate of increase decreases. When the upstream Froude number is 0.4 higher, the dimensionless width and length changing ratio of the separation zone are about 2.56 and 5.5 times higher than in 0.4 or less.

Effect On the Air Permeability of Composting Bulking Agent (퇴비화 첨가제의 공기투과성에 대한 분석)

  • Kim, Byung Tae
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.3
    • /
    • pp.71-82
    • /
    • 2012
  • Common bulking agents in composting system include woody materials such as sawdust and woodchips. These bulking agents are mainly used for the purpose of the proper control of C/N ratio and moisture content in the composting. The topic for the effect on air permeability of bulking agents has far received relatively little attention in the composting field. This study investigated the effect of bulk density, moisture content, air-filled porosity, particle size and air flow rate on air permeability of several mixture ratios of sawdust and woodchip bulking agent. Increasing the moisture contents, the air-filled porosity was decreased and the particle size was increased for all kinds of bulking agent mixtures. Especially, with the increasing of mixing ratio of woodchip, these effects were sharply magnified. The air permeability respond to air-filled porosity was very similar to that for moisture content which was anticipated the linear relationship between air-filled porosity and moisture content. Above the region of moisture content 0.25 or 0.43(d.b.)(20 or 30% w.b.), the pressure drop decreased even though air-filled pore spaces were filling with water. Especially, to the particle size of 5 mm the pressure drop was decreased exponentially, so the air permeability was dramatically improved. By the water had the role of binding of the small particles, the macropores less resistances to air flow were created in the matrix. The effect of particle size on air permeability was much stronger than that of air-filled porosity or moisture content. And it is needed the preparing of initial particle size above 5 mm for efficient composting.

Extraction of Glabridin from Licorice Using Supercritical Carbon Dioxide (초임계 이산화탄소를 이용한 감초 중의 glabridin 추출)

  • Cho Yun-Kyoung;Kim Hyun-Seok;Kim Ju-Won;Lee Sang-Yun;Kim Woo-Sik;Ryu Jong-Hoon;Lim Gio-Bin
    • KSBB Journal
    • /
    • v.19 no.6 s.89
    • /
    • pp.427-432
    • /
    • 2004
  • The purpose of this study is to investigate the feasibility of a cosolvent-modified supercritical $CO_2\;(scCO_2)$ extraction technique for the production of licorice extracts with high levels of glabridin. The effects of various parameters such as the type and amount of modifiers, extraction temperature ($40{\sim}80^{\circ}C$) and pressure ($10{\sim}50.0\;MPa$) on the extraction efficiency were examined at a fixed flow rate of 1 mL/min. The organic solvent extraction with pure methanol was also conducted for a quantitative comparison with the $scCO_2$ extraction. The recovery of glabridin from licorice was found to be extremely small for pure $scCO_2$. However, the addition of modifiers such as ethanol and acetone to $scCO_2$ resulted in a significant improvement in the recovery of glabridin. The recovery of glabridin was observed to increase with pressure at a constant temperature. Furthermore, the purity of the glabridin obtained from the $scCO_2$ extraction was higher compared with the organic solvent extraction.

Establishment of the Detention Model for the Prevention of Unban Innundation (도시침수방지를 위한 저류지 모형 확립)

  • Park, Jae-Hong;Han, Kun-Yeun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1656-1660
    • /
    • 2006
  • 도시 주변의 급격한 택지개발, 도시 인구의 집중, 대규모 계획단지의 개발은 유역의 유출특성에 큰 영향을 주게 되고, 도시화가 진행됨에 따라 불투수 표면이 증가되고 침투율이 감소됨으로써 유출계수의 증가요인이 되고 있다. 이에 따라 유역의 자연 저류지 기능이 저하되고, 우수가 하천으로 유입되는 시간이 단축됨으로써 첨두홍수량 뿐만 아니라 유출총량의 증대를 초래하여 도시 주변의 중소하천 유역에서는 막대한 재산 및 인명 피해가 발생하고 있다. 이러한 도시화로 인해 증가된 유출량을 저감시키는 구조적 방안으로 대부분 강우 유출수를 일시 저류하여 유출량을 조절하는 우수유출 억제시설이 권장되고 있으나, 이들 시설에 대한 수리학적 침수방어능력이 명확히 규명되지 못한 실정이다. 본 연구의 목적은 도시지역 침수방지 대책 수립에 필요한 On/Off-Line 저류지의 평가 및 설계에 기존 부정류 모형들의 모의가능성을 평가 비교하고, 가상하도와 실제하도에 적용하여 모형을 검보정 함으로서 저류지 해석의 실용화 모형을 확립함에 있다. 본 연구 결과는 도시지역에 적용할 수 있는 도시홍수방어시스템의 일환으로 구축함으로써, 도시지역에서 저류지 홍수저감효과를 평가하는 등 침수재해와 연계된 구조적 대책 수립에 필요한 기초자료로 활용하고자 한다. 본 연구에서 연구된 저류지 모형을 이용하여 On-Line 및 Off-Line 저류지에 적용한 결과 두 종류의 저류지 모두 홍수방어를 위해 이용될 수 있었다. On/Off-Line 저류지 모두 첨두유량이 발생할 경우 어느정도의 첨두값의 감쇠를 발생시킬 수 있는 것으로 판단된다. 그러나 저류지 상류단의 수위감소는 저류지로 유출로 인해 저류지 상류 하도부에서 유속의 증가를 발생시켰고 이로 인해 수위는 저류지가 존재하지 않는 경우보다 낮게 나타나고 있다. On-Line 저류지의 경우 Off-Line 의 경우에 비해 수위, 유량이 저류지의 상류단에서 크게 나타났다. On-Line 저류지의 경우 Off-Line 의 경우에 비해 같은 값의 첨두홍수량을 저류하기 위해서 상대적으로 넓은 저류면적이 필요한 것으로 나타난다. 대등한 수위감소값의 홍수저감효과를 발휘하기 위해서 본 연구에서는 On-Line 저류지 면적은 Off-Line 저류지에 비 두배 이상이 필요한 것으로 보여졌다.

  • PDF

A New Circulation Method for Electrokinetic Remediation of Soil Contaminated with Lead (새로운 순환방식을 적용한 동전기 정화기술에 의한 오염토양내의 납제거)

  • 이현호;백기태;양지원
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.1
    • /
    • pp.9-16
    • /
    • 2003
  • A new method has been proposed and developed that solves the problem of decreasing electroosmotic flow rate by excess $H^{+}$ and precipitation of heavy metal by $OH^{-}$. An electrolytic solution was circulated between the anode and cathode compartments that enabled the pH at the anode and cathode to be controlled. The change of the soil pH by circulation systems affects the operation time, by lowering the rate of increase of the electric potential gradient, and the removal efficiency of heavy metals, by affecting the soil pH. Since there was no effluent from the cathode compartment in circulation system, there was no need to treat the wastewater after the experiment, which resulted in the reduction of influent electrolyte volume.

Application of CFD model for the design of settling basin inlet structure (침전지 유입부 설계를 위한 CFD모형의 적용)

  • Yu Chang Hwan;Lee Jong Hyun;Kim Dae Geun;Kim Nam Il
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1083-1087
    • /
    • 2005
  • 하수처리장의 침전지는 고형물(SS)을 침전, 제거하여 하수를 정화하는 시설로서 생물학적처리에 의해 발생하는 슬러지와 처리수를 분리하는 것을 주목적으로 한다. 장방형침전지의 경우, 유입된 하수가 침전지의 전 단면에 걸쳐 균일하게 도달하게 하기 위하여 $6\~20\%$ 정도의 유공율을 가진 유공정류벽을 설치하며 유효 침전구역에서의 유속은 0.08 m/sec 이하가 되도록 설계되어야 한다. 지금까지 침전지 유입부의 설계시에는 상기 설계기준만을 참조하여 설계가 진행되고 있는 실정으로 보다 나은 대안을 도출하기 위한 분석은 미흡한 실정이다. 본 연구에서는 3차원 수치모형인 FLOW-3D를 이용하여 침전지의 유입부 설계를 위한 설계인자를 도출하였다. 특히 유공정류벽의 크기, 위치 유공율에 따라서 유입하수의 수리적인 특성을 3차원적으로 분석하였다. 저류벽의 위치에 따른 유량의 분배효과를 검토하기 위하여 저류벽의 폭, W를 2.4 m로 고정하고 유입부에서 저류벽까지의 거리, L을 1.5 m, 2.0 m, 2.5 m로 변화시키며 수치모의를 수행하였다. 그리고 저류벽의 폭에 따른 유량의 분배효과를 검토하기 위하여 L을 고정하고 W를 변화시키며 수치모의를 수행하였다. 유공정류벽의 유공율에 따른 유량의 연직 분배효과를 검토하기 위하여 유공율을 변화시키며 연직위치별 통과유량을 산정하였다 각 모의조건에 대한 통과유량 산정결과, 유공율이 $7\%$일때 통과유량의 표준편차가 가장 작게 발생하며, 유공율이 $7\%$보다 감소하거나 증가하면 표준편차가 증가하고 있음을 알 수 있다. 본 연구에서는 상용 CFD모형인 FLOW-3D를 계획 중인 하수처리장의 침전지 유입부 설계에 적용하였으며 저류벽의 위치와 폭, 유공정류벽의 유공율에 따른 유입하수의 분배효과를 분석하였다. 실험을 수행하여 보다 정밀한 공식으로 개선할 수 있었다.$10,924m^3/s$ 및 $10,075m^3/s$로서 실험 I의 $2,757m^3/s$에 비해 통수능이 많이 개선되었음을 알 수 있다.함을 알 수 있다. 상수관로 설계 기준에서는 관로내 수압을 $1.5\~4.0kg/cm^2$으로 나타내고 있는데 $6kg/cm^2$보다 과수압을 나타내는 경우가 $100\%$로 밸브를 개방하였을 때보다 $60\%,\;80\%$ 개방하였을 때가 더 빈번히 발생하고 있으므로 대상지역의 밸브 개폐는 $100\%$ 개방하는 것이 선계기준에 적합한 것으로 나타났다. 밸브 개폐에 따른 수압 변화를 모의한 결과 밸브 개폐도를 적절히 유지하여 필요수량의 확보 및 누수방지대책에 활용할 수 있을 것으로 판단된다.8R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는 경사도가 증가할수록 증가하였으며 $10\% 경사일 때를 기준으로 $Ro(mm)=Ro_{10}{\times}0.797{\times}e^{-0.021s(\%)}$로 나타났다.천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주었다.특히 교사들이 중요하게 인식하는 해방적 행동에 대한 목표를 강조

  • PDF