• Title/Summary/Keyword: 유속센서

Search Result 123, Processing Time 0.028 seconds

Application of Image Technique and Optical Fiber Sensor for Air-water Mixture Flow (기포흐름 측정을 위한 영상기법 및 광섬유센서 적용)

  • Ryu, Yonguk;Jung, Tae-Hwa
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.7
    • /
    • pp.535-543
    • /
    • 2015
  • Measurements of multiphase flows containing bubbles have been limited because most existing methods target one phase flows. Especially, multiphase flows with a high void ratio have been rarely successful in measurements due to the sudden change of density and thick interfaces between air and water. This study introduces two methods that are capable of measuring flow fields regardless of bubble void ratio, named bubble image velocimetry and bundle fiber optic flow meter. The calculation of the depth of field is suggested to reduce and estimate errors by perspective image velocimetry. The bundle fiber optic flow meter is designed to increase a measurement rate using many optical fibers with a thin diameter. The two methods measured bubble plumes to test reliability and the velocity measurements show good agreement. In addition a hydraulic jump, one of the multiple flows in rivers was measured to test applicability of the methods.

Evaluation of Interactions Between Surface Water and Groundwater Based on Temperature, Flow Properties, and Geochemical Data (온도, 유동특성 및 지화학분석 자료를 이용한 지표수-지하수 연계특성 평가)

  • Jeon, Hang-Tak;Kim, Gyoo-Bum
    • The Journal of Engineering Geology
    • /
    • v.21 no.1
    • /
    • pp.45-55
    • /
    • 2011
  • We examined the interactions between surface and groundwater through (1) flowmeter logging, (2) measurements of seasonal and vertical changes in temperature within a well, and (3) geochemical analyses of water samples from nine groundwater-monitoring wells. At two wells adjacent to a stream, subsurface water was found to flow from the stream to a surrounding alluvial fan, and the seasonal change in groundwater temperature is similar to those of surface water and air. Geochemical analyses at two wells indicated hydro-geochemical features affected by streamwater inflow, showing seasonal variations. Accordingly, these two wells are located in an area with active interaction between surface water and groundwater. The Thermochron I-button used in the present study is useful for this type of study of groundwater?surface water interaction because of its low cost and small size.

Improvement of ISO 748 for Uncertainty Calculation Method in Discharge Measurement using Float (부자를 이용한 유량 측정 불확도 산정 방법에 대한 ISO 748 기준의 개선 연구)

  • Ahn, Myeong Hui;Kim, Seojun;Yoon, Byungman;Kim, Dongsu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.105-105
    • /
    • 2016
  • 최근 기후변화 위기에 따른 대책으로 하천 유량 모니터링이 제시될 정도로 유량자료의 중요성이 확대되고 있다. 하천의 유량자료는 수자원개발 및 하천 방재의 중요한 기초자료로 이용되기 때문에 유량 산정 결과에 대한 신뢰도 즉, 측정 불확도를 정량적으로 제시하기 위한 연구는 오래 전부터 많은 연구자들에 의해 수행되었다. 1963 ~ 1970년에 영국 및 미국의 다수 하천의 유량 측정자료를 활용하여 국제표준화기구(ISO)에서 제시한 ISO 748이 대표적인 지침서이다. 현재 국내 유량조사 업무에서도 ISO 748의 측정 불확도 평가 방식을 이용하여 유량 측정 결과의 신뢰도를 제시하고 있다. 하지만 하천 유량조사는 현장 상황과 측정 인력의 경험 등에 따라 차이가 크게 발생할 수 있으며, 최근 첨단 센서를 활용한 유량 측정 기법들이 다수 개발되어 사용 중일 뿐만 아니라 측정 불확도 평가 체계를 GUM(Guide to the Expression of Uncertainty in Measurement)으로 변화해가고 있는 추세 등을 고려하였을 때 기존의 ISO 748에서 제시한 유량 측정 불확도 평가 방법에 대한 재검토에 대한 요구가 증대되고 있다. 특히 국내에서 홍수 시 유량 조사 방법으로 가장 많이 사용하고 있는 부자법의 경우 ISO 748에서 제안한 방법으로 측정 불확도를 제시하고 있지만 실제적으로 현장 상황을 고려하지 못하고 있는 것이 사실이다. 예를 들어 육안으로 관측하기 어려워 부자의 유하거리를 직선으로 가정함에 따른 불확도를 포함하지 못하고 있고, 부자가 유하하는 동안 부자의 흘수가 일정하지 않음에 따른 불확도를 포함하지 못하고 있다. 특히 부자 투하 측선과 유량 측정 단면을 부자가 지나가는 측선이 다름에 따른 불확도는 반드시 포함되어야 하지만 고려할 방법이 없어 아직까지 반영되지 못하고 있는 실정이다. 이에 본 연구에서는 부자를 이용한 유속 측정 불확도 산정에 있어서 그동안 ISO 748에서 정량적으로 고려하지 못한 불확도 인자들에 대하여 영상기법을 활용한 실험적 검토를 통해 정량적인 평가 기준을 제시하고자 한다. 이를 위해 실제 하천 규모의 흐름을 재현할 수 있는 안동하천실험센터의 직선수로에서 다양한 수리조건에 대한 부자를 이용한 유속 측정을 실시하여 측정 불확도를 산정하고자 한다. 본 연구 결과는 향후 부자를 이용한 유량 측정 불확도 평가 방법을 개선할 수 있고, 더 나아가 부자를 이용한 유량 측정 방법의 문제점을 개선할 수 있기 때문에 정확도를 향상에 크게 기여할 수 있을 것으로 기대한다.

  • PDF

Development of Demonstration Technology for Flash Flood Forecasting using Rainfall Radar in Flood Vulnerable Area of Nakdong River Basin (강우레이더 자료를 활용한 낙동강유역 홍수예보 취약지역 돌발홍수예보 실증 기술 개발)

  • Hwang, Seok Hwan;Shin, Chang Ho;Kim, Keuk Soo;Choi, Kyu Hyun;Cho, Hyo Seob
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.320-320
    • /
    • 2021
  • 홍수피해가 빈발하는 도시 및 소규모 산지 유역에서와 같이 지체시간이 짧은 유역에서 국지적으로 발생하는 돌발홍수는 우량계와 기존 하천유역 예보시스템만으론 예보가 불가능하다. 동일한 강우에서도 지역에 따라 침수시간이나 침수심이 달라지기 때문에 정확한 돌발홍수예보를 위해서는 지역에 따른 침수특성과 유속특성을 달리 고려해야 한다. '골든타임 확보를 위한 유역 시공간 상세 홍수예보기술 개발(환경부)'에서 개발한 '국지 돌발홍수예측 시스템'은 지역별 검증된 침수특성과 유속특성의 관계식을 산정하여 돌발홍수예보 기준을 설정하였다. 그리고 도달시간이 짧은 도시 및 산지에서 홍수예보 선행시간을 확보하기 위해 강우레이더 기반 돌발홍수 예측 시스템을 구축하여 시범 운영 중이다. 그러나 도시·산지 중소하천유역 등 홍수예보 취약지역에 대한 돌발홍수예보 정확도를 제고하기 위해서는 기 설정된 돌발홍수위험 예보 기준을 정밀하게 평가·검증·개선 할 수 있는 실증 체계가 반드시 필요하다. 이러한 배경에서 본 연구에서는 2021년부터 3개년 동안 홍수예보 취약지역에 강우레이더와 경제적 IoT 관측센서 정보를 기반으로 돌발홍수예보 실증기술을 개발하여 전국 돌발홍수예보 실용화 기반 구축하고자 한다. 홍수피해 취약지역인 도심지, 산지·계곡, 해안지역에 실증 테스트베드를 선정하고 강우레이더-IoT 실증 관측망을 구축하여 돌발홍수예보 기술 실증과 돌발홍수 위험기준 설정 가이드라인을 마련하고자 한다. 더불어 도시 중소하천유역 홍수예보 활용을 위한 소형강우레이더 강우량 정확도 개선 기술 개발과 홍수기 강우레이더 기반 홍수예보 관-연 협업 시범 운영을 추진할 계획이며, 최종적으로는 강우레이더와 IoT 정보 기반 돌발홍수 실증 시스템을 구축 운영하고자 한다.

  • PDF

Fluvial mixing characteristics in large scale confluence between Nam and Nakdong River (남강-낙동강 합류부 대하천 규모 수리학적 혼합특성 연구)

  • Choi, Suin;Kim, Dongsu;Son, Geunsoo;Kim, Youngdo;Lyu, Siwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.264-264
    • /
    • 2022
  • 하천의 합류부는 두 개 이상의 하천이 하나로 합쳐지는 구간으로 서로 다른 특성으로 인해 급격한 흐름의 변화와 수리학적 지형변화가 발생하는 구간이다. 하천의 합류부에서는 유체의 물리화학적인 특성과 흐름 구조의 변화가 발생할 수 있다. 흐름 구조의 변화로 인한 유사 이송으로 세굴과 같은 지형적인 변화가 발생할 수 있다. 합류부의 혼합을 이해하기 위해서는 본류와 지류의 다양한 유입조건에 따른 공간적인 패턴을 분석하는 것이 중요하다. 그러나, 대부분의 합류부 연구들은 실측에 기반한 공간적인 패턴 분석의 어려움으로 인해 실내실험 또는 수치모형에 의존하여 연구가 수행되어, 실측자료에 기반한 공간적인 수체혼합의 분석은 매우 제한적이었다. 따라서, 본 연구에서는 하천 합류부의 혼합 현상을 규명하는 인자로 흐름 방향 유속, 2차류와 수심 등 기본적인 수리학적 인자들 외에 연직, 수평 방향으로 측정한 수질 자료와 드론 영상을 활용하여 합류부의 혼합 특성을 해석하고자 하였다. 수질 자료 중 하천의 혼합을 가장 잘 확인할 수 있는 인자로써 전기전도도와 온도를 활용하였다. SonTek ADCP를 이동식으로 횡단하여 측정해 흐름 방향 유속과 2차류, 수심을 확인하였다. ADCP를 운용함과 동시에 YSI의 수질센서를 활용하여 연직, 수평 방향으로의 전기전도도와 온도의 분포를 확인하였다. 또한, 합류부의 2차원 공간적인 분포를 확인하기 위해 드론 영상을 촬영하였다. ADCP, YSI, 드론의 계측자료는 한국의 낙동강과 남강 합류부에서 측정되었고, 분석 결과 계측장비 간의 경향성이 일치하였다. 또한, 이전에 진행된 해외의 합류부 연구 결과와 유사한 결과가 관측되었으나, 일부 부분에서는 다른 결과를 보였다.

  • PDF

Accuracy Analysis of ADCP Stationary Discharge Measurement for Unmeasured Regions (ADCP 정지법 측정 시 미계측 영역의 유량 산정 정확도 분석)

  • Kim, Jongmin;Kim, Seojun;Son, Geunsoo;Kim, Dongsu
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.7
    • /
    • pp.553-566
    • /
    • 2015
  • Acoustic Doppler Current Profilers(ADCPs) have capability to concurrently capitalize three-dimensional velocity vector and bathymetry with highly efficient and rapid manner, and thereby enabling ADCPs to document the hydrodynamic and morphologic data in very high spatial and temporal resolution better than other contemporary instruments. However, ADCPs are also limited in terms of the inevitable unmeasured regions near bottom, surface, and edges of a given cross-section. The velocity in those unmeasured regions are usually extrapolated or assumed for calculating flow discharge, which definitely affects the accuracy in the discharge assessment. This study aimed at scrutinizing a conventional extrapolation method(i.e., the 1/6 power law) for estimating the unmeasured regions to figure out the accuracy in ADCP discharge measurements. For the comparative analysis, we collected spatially dense velocity data using ADV as well as stationary ADCP in a real-scale straight river channel, and applied the 1/6 power law for testing its applicability in conjunction with the logarithmic law which is another representative velocity law. As results, the logarithmic law fitted better with actual velocity measurement than the 1/6 power law. In particular, the 1/6 power law showed a tendency to underestimate the velocity in the near surface region and overestimate in the near bottom region. This finding indicated that the 1/6 power law could be unsatisfactory to follow actual flow regime, thus that resulted discharge estimates in both unmeasured top and bottom region can give rise to discharge bias. Therefore, the logarithmic law should be considered as an alternative especially for the stationary ADCP discharge measurement. In addition, it was found that ADCP should be operated in at least more than 0.6 m of water depth in the left and right edges for better estimate edge discharges. In the future, similar comparative analysis might be required for the moving boat ADCP discharge measurement method, which has been more widely used in the field.

Vapor Recognition Using Image Matching of Micro-Array Sensor Response from Portable Electronic Nose (휴대용 전자 후각 장치에서 다채널 마이크로 센서 신호의 영상 정합을 이용한 가스 인식)

  • Yang, Yoon-Seok
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.2
    • /
    • pp.64-70
    • /
    • 2011
  • Portable artificial electronic nose (E-nose) system suffers from noisy fluctuation in surroundings such as temperature, vapor concentration, and gas flow, because its measuring condition is not controled precisely as in the laboratory. It is important to develop a simple and robust vapor recognition technique applicable to this uncontrolled measurement, especially for the portable measuring and diagnostic system which are expanding its area with the improvements in micro bio sensor technology. This study used a PDA-based portable E-nose to collect the uncontrolled vapor measurement signals, and applied the image matching algorithm developed in the previous study on the measured signal to verify its robustness and improved accuracy in portable vapor recognition. The results showed not only its consistent performance under noisy fluctuation in the portable measurement signal, but also an advanced recognition accuracy for 2 similar vapor species which have been hard to discriminate with the conventional maximum sensitivity feature extraction method. The proposed method can be easily applied to the data processing of the ubiquitous sensor network (USN) which are usually exposed to various operating conditions. Furthermore, it will greatly help to realize portable medical diagnostic and environment monitoring system with its robust performance and high accuracy.

GPR Survey for the Assessment of Scour Depth near Bridge Piers (세굴심 추정을 위한 교각 우물통 주변의 GPR 탐사)

  • Park, In-Chan;Cho, Won-Cheol;Lee, Chong-Guk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.996-1000
    • /
    • 2005
  • 본 연구에서는 마포대교 확장 공사의 인해 일부 교각의 우물통 기초 주변 하상변화와 세굴 현상을 파악하기 위한 심도추정 방법으로 현재 다양하게 토목분야에서 적용되고 있는 치하투과레이더 탐사기법을 사용하였다. 교각 우물통 주변의 안정적인 GPR 탐사를 수행하기 위한 보조장비를 고안하여 마포대교 P6의 우물통 주변을 2004년 6월(1차)과 2004년 10월(2차)에 걸쳐 탐사를 실시하였으며, 탐사 기간 중 약 12,000 cms의 유출량이 발생하여 국부세굴과 하상 변화 가능성을 충분히 검토 할 수 있을 것으로 판단되었다. 수집된 자료를 통해 양질의 자료 획득을 위해서 자료의 보정 과정을 마친 후 각각의 구간에 대해서 1, 2차 탐사된 두 개의 자료를 비교 분석하였다. 전구간의 반사파를 이용하여 기존의 연구결과에서 얻어진 반사파의 양상(Beres and Haeni, 1991)과 비교한 결과 하상 표면은 미사 혹은 실트로 구성되어 있고 주요한 하상 하부 매질은 전석(boulder), 호박돌 등으로 이루어져 있었다. 그리고 1차 및 2차 탐사 자료와 DATAPCS의 세굴센서가 설치된 측점을 기준으로 심도 및 위치 보정을 한 결과 큰 오차는 발생하지 않았으며, 400 MHz 안테나를 활용하여 최대수심 약 10 m 이상 하상을 탐사할 수 있었다. 수심이 깊은 구간은 하상과 가까운 위치에서 탐사를 실시하여 양질의 하상 변화 양상을 파악할 수 있어 하상 재료의 정성적인 평가를 높일 수 있도록 하였다. 마포대교의 탐사 대상 교각 우물통 주변은 계획홍수량의 1/3 수준으로 비교적 적은 홍수량이 발생한 2004년의 호우사상으로 인해 일부구간이 약 $10\~20\;cm$ 정도의 퇴적과 세굴 영향이 나타난 것을 제외하고는 유의할 만한 세굴과 하상 변화가 발생하지 않고 매우 안정적인 상태를 보이고 있으며 되메움이나 두드러진 퇴적층의 양상 또한 확인할 수 없었다. 대상구간에 설치한 유속계 최대유속이 2.0 m/s 이상 발생하였지만 우물통 주변의 자갈 및 호박돌 등과 같은 평균입경이 큰 유사의 이동에 절대적인 한계유속을 초과하지 못한 것으로 판단된다. GPR 탐사의 적용 한계성을 극복한 본 연구는 홍수 전$\cdot$후의 하상변화 및 최대세굴심, 되메움 깊이 및 범위 등의 세굴현상을 현장탐사를 바탕으로 현재 다양하게 적용하고 있는 세굴 실험식과 비교 분석함으로써 우물통 주변의 효율적인 세굴 보호 대책을 강구하는 목적으로 그 활용성을 증대할 수 있을 것이다.

  • PDF

The $CH_4$and $C_4$$H_{10}$ Sensitivity Measurement and Voltage Variation Using Catalytic Combustion Type Gas Sensor (접촉연소식 센서를 이용한 $CH_4$$C_4$$H_{10}$ 감도 측정 및 전압변화)

  • 윤헌주;신종열;홍진웅
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.44-48
    • /
    • 2001
  • In this study, we analyzed the $CH_4$and $C_4$$H_{10}$ sensitivity measurement and voltage variation using catalytic type gas sensor characteristics in catalytic combustion type gas detecter sensors. Gas detector shall operate as intended when exposed for 24 hours to air having a relative humidity of 65 percent at a temperature of $20^{\circ}c$ and humidity of 85 percent at a temperature of $40^{\circ}c$. The gas detecter sensors are to be subjected to operation for 210 days in an area that has been determined to be equivalent to a typical residential atmosphere with an air velocity of 50 cm/sec. The source of energy for a gas detector sensors employing a supplementary basic circuit is energized from a seperate source of supply direct applied voltage 2.1V, 2.2V, 2.3V. As a result, it was confirmed that the relative humidity and temperature by regression each analysis, compared to the isobutane characteristic graph and methane characteristic graph by a relative humidity of 65% and 85% at a temperature($20^{\circ}c$, $40^{\circ}c$) show a similar linear pattern on the whore.

  • PDF

A Study on the Characteristics of Mass Transfer in Hollow Fiber Membranes (중공사막에서의 물질전달 특성에 관한 연구)

  • 김기범;김종석;김종수;유일수;이왕로;김성종
    • Membrane Journal
    • /
    • v.14 no.2
    • /
    • pp.142-148
    • /
    • 2004
  • This paper presents the enhancement of oxygen transfer efficiency using vibrating intravascular lung assist device (VIVLAD) for patients having chronic respiratory problems. The flow rate was controlled by the pump and monitored by a built-in flow meter. The vibration apparatus was composed of a piezo-actuator, a function generator, and a power amplifier. Gas flow rates of up to 6 L/min through the 120-cm-long hollow fibers have been achieved by exciting a piezo-actuator. The output PVDF sensor and FRF (frequency response function) were investigated by various frequency in VIVLAD. As a result, the maximum oxygen transfer rate was found to occur with maximum amplitude and the transfer of vibration to the hollow fiber membranes. It was excited by the frequency band of 35 Hz at various distilled water flow rates, and various module types.