• Title/Summary/Keyword: 유방폭

Search Result 14, Processing Time 0.019 seconds

Radiologic Findings of Uncommon Breast Cancer (드문(Uncommon) 유방암의 방사선학적 소견)

  • Kim, Jae-Woon;An, Jae-Hong;Hwang, Mi-Soo;Lee, Jae-Kyo;Byun, Woo-Mok
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.1
    • /
    • pp.114-124
    • /
    • 1998
  • We analyzed the mammographic (n=21) findings (location, margin, shape, cluster microcalcifications, size, multiplicity) and ultrasonographic (n=12) findings (shape, border, internal echo, boundary echo, posterior echo, lateral echo, width/depth ratio) to evaluate specific radiologic findings of histopathologically proved uncommon breast cancer. The mammographic findings (n=21) are as follow; 1) single; 16, multiple; 5 2) margin (smooth; 13, irregular; 4, spiculated; 4) 3) shape (round and ovoid; 9, lobulated; 8, irregular; 4) 4) cluster micro calcifications (abscent; 20, present; 1) 5) size (1-3cm; 18, 3-5cm; 2, 5cm> ; 1) 6) location (UOQ; 13, UIQ; 4, LIQ; 3, LOQ; 1). The ultrasonographic findings (n=12) are as follow; 1) shape (round to oval; 5, lobulated; 5, irregular; 2) 2) border (smooth even; 9, rough uneven; 3) 3) internal echo (fine homogeneous; 5, coarse heterogeneous; 7) 4) boundary echo (regular fine; 4, irregular thick; 8) 5) posterior echo (enhanced; 11, no change; 1) 6) lateral echo (marked; 7, nonexistent; 5) 7) width/depth ratio (1.5> ; 1, 1.0-1.5; 7, 1.0< ; 4). Uncommon breast cancer show benign nature on mammogram, but malignant nature on ultrasonogram (especially boundary echo, internal echo, width/depth ratio).

  • PDF

Classification of Size System of Brassiere According to the breast types for Improvement of the Wearing Comfort (착용 기능성 개선을 위한 유방 형태별 브래지어 치수체계 설정)

  • 임지영
    • Journal of the Korean Home Economics Association
    • /
    • v.41 no.6
    • /
    • pp.119-129
    • /
    • 2003
  • This study was peformed to establish the standard size system to be required for the production of brassiere. The subject were 155 Korean twenties-aged women and were directly measured anthropometrically. From 27 measurements, 5 factors were extracted through factor analysis. The accumulative contribution ratio is 76.92%. Factor 1 indicates the degree of obesity around the chest, factor 2 is the drooping degree of breast, factor 3 is the contours and prominence, factor 4 is the breast breadth and breadth of bust point, factors 5 is the volume of breast. The subject were classified into 3 cluster as their breast types through cluster analysis. Type 1 is the closest to the ideal breast shape and not too droopy. This group belonged to 75A. Type 2 has small breast and belonged to 70AA group. Type 3 is the obesest and has the biggest and droopy breast. This group belonged to 75B. The distribution of size of brassiere had 3 sections from 70 to 80 showing a rate of 81.94% and the sin of the cup had 4 sections from AAA cup to B cup showing a rate of 89.70%. The production ratio of each brassiere size, it was found that the brassiere size of highest production ratio was 75A(16.39%) in type 1,70AA(16.27%) in type 2, and 75B(13.72%) in type 3. This suggests that it is necessary to adjust for the production rate of brassieres.

A Study on Wearing Tests of Mastectomy Brassieres with Prostheses (유방절제환자를 위한 보정용 브래지어와 부속물 착장실험연구(III))

  • Hei-Sun Choi;Kyung Mi Lee
    • Journal of the Korean Home Economics Association
    • /
    • v.40 no.8
    • /
    • pp.13-21
    • /
    • 2002
  • 본 연구의 목적은 유방절제수술을 받은 여성들을 위해 개발한 다섯 종류의 브래지어와 두 종류의 보정물 유형에 따른 착용감과 쾌적성을 검토하기 위한 것이다. 피험자로는 유방절제시술기간이 3년 이상이며 브래지어 사이즈 85에 컵사이즈 A컵인 여성 세 명을 선정하였다. 실험방법은 보정물을 삽입한 브래지어를 하루에 최소 15시간 이상 연속착용하도록 하고 실험복을 착용한 상태에서 피험자들의 일상과 그에 소요된 시간을 기록하도록 하였으며 이 때 착용한 브래지어와 보정물에 대한 느낌을 5점 척도로 표시하게 하였다. 실험기간은 다섯 종류의 브래지어를 하루에 한 가지씩 정해진 순서대로, 처음 5일은 옥보정물과 함께 착용하도록 하고 그 후 5일은 스펀지 보정물과 함께 착용하도록 하였으며 이러한 순서를 두 번 반복하게 하여 총 20일이 소요되었다. 각각의 피험자들에 대해서는 실험이 진행되는 동안 반복적인 면접을 통하여 진행상황을 기록하였으며 아울러 실험복에 대한 제언을 수렴하여 보다 나은 제품개발을 위한 기본 자료화하였다. 실험결과는 다음과 같다. 1. 브래지어에 있어서는 세 명의 피험자가 일치된 결과를 나타내어 일반적인 브래지어 형태와 가장 유사하면서 어깨 끈과 하변밴드 폭만 약간 넓혀준 실험복이 착용감에서 가장 높은 점수를 받았다. 착용자의 편의를 고려하여 앞트임으로 제작한 실험복의 경우에는 앞으로 구부렸을 때 밴드부분이 꺾이는 현상이 생겼으며 피험자들이 모두 뒤트임에 익숙하여 앞트임 브래지어 착용에 불편함을 나타내었다. 브래지어 착장평가에 있어서는 피험자들의 일상적인 행동이나 보정물의 종류가 영향을 미치지 않는 것으로 나타났다 2. 보정물 평가에 있어서는 모든 피험자가 옥가루 재질의 보정물만으로는 수술부위를 자극하는 느낌이 든다고 하였으나 3mm 두께의 스펀지와 함께 삽입했을 때는 아무런 문제가 없는 것으로 나타났다. 또한 보정물의 무게 조절이 가능하므로 실리콘재질의 보정물에서 쉽게 찾아볼 수 있는 무게에 대한 문제를 제기한 피험자는 없었다. 그러나 스펀지로 제작된 보정물에 대해서는 무게가 너무 가벼워 모든 피험자들이 양 쪽 가슴의 균형이 잘 맞지 않는다고 답하였으며 특히, 운동을 즐기고 활동이 많은 피험자의 경우 스펀지로 제작된 보정물에 대해 큰불만을 표시하였다.

Bolus Effect to Reduce Skin Dose of the Contralateral Breast During Breast Cancer Radiation Therapy (유방암 방사선치료 시 반대편 유방의 피부선량 감소를 위한 볼루스 효과)

  • Won, Young Jin;Kim, Jong Won;Kim, Jung Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.289-295
    • /
    • 2017
  • The aim of this study was to evaluate the dose comparison using Radon phantom with 5 mm and 10 mm tissue equivalent materials, FIF, Wedge(15, 30 angle) and IMRT, to reduce the skin dose of the contralateral breast during breast cancer radiation therapy(Total dose: 50.4Gy). The dose was measured for each treatment plan by attaching to the 8 point of the contralateral breast of the treated region using a optical-stimulated luminance dosimeter(OSLD) as a comparative dose evaluation method. Of the OSLD used in the study, 10 were used with reproducibility within 3%. As a result, the average reduction rates of 5 mm and 10 mm in the FIF treatment plan were 37.23 cGy and 41.77 cGy, respectively, and the average reduction rates in the treatment plan using Wedge $15^{\circ}$ were 70.69 cGy and 87.57 cGy, respectively. The IMRT showed a reduction of 67.37 cGy and 83.17 cGy, respectively. The results of using bolus showed that as the thickness of the bolus increased in all treatments, the dose reduction increased. We concluded that mastectomy as well as general radiotherapy for breast cancer would be very effective for patients who are more likely to be exposed to scattered radiation due to a more demanding or complex treatment plan.

Changes in Spatial Resolution at Position of the Detector in Digital Mammography System (디지털 엑스선유방촬영장치에서 검출기 위치에 따른 공간분해능의 변화)

  • Kim, Hye-Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.215-222
    • /
    • 2016
  • X-ray mammography is the most effective method for the diagnosis of calcified lesions of various breast diseases. To reduce patient dose and to obtain optimal image required for diagnosis, the performance of the mammography system should be maintained continuously. Because the target (anode) angle of the X-ray tube is measured from the central X-ray, the effective angle can be slightly different in view of the position on the detector, which can result in degrading spatial resolution of the imaging within the field of view. In this study, we measured the MTF to examine spatial resolution for positions on the detector in the digital mammography system. For a tungsten wire of $50{\mu}m$ diameter, the highest spatial frequency was obtained. It meant that a wire diameter for measuring MTF through LSF should be small compared to the pixel size of the detector used in the mammography system. The spatial resolution showed slightly different performance according to positions on the detector. The center position gave the best spatial resolution and positions away from the center showed the degraded performance although the difference of the spatial resolution was small. The effective focal spot size of the full width at half maximum also showed similar result. It concluded that the slightly increase of the effective focal spot size gave the degradation of the spatial resolution for positions on the detector.

Effects on the Risk of Cardiovascular Disease in Breast Cancer Patients Received Postoperative Adjuvant Anticancer Therapy (유방암 환자의 수술 후 보조적 항암 치료가 심혈관질환 위험에 미치는 영향)

  • Yu, Mi-Seon;Lee, Tae-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2971-2980
    • /
    • 2014
  • To find the risk of cardiovascular disease for breast cancer patients received postoperative adjuvant anticancer therapy, this study was investigated the change of serum lipid profile (total cholesterol and trigyiceride) and the 10 year risk score of ischemic heart disease. Medical data of 432 breast cancer patients diagnosed at the breast cancer center in an university hospital from January, 2003 to December, 2006 were collected and analysed. The results showed that the levels of total cholesterol and triglyceride were increased at the points of 2 and 5 years after operation. The margin of increase of total cholesterol was higher in the patients without endocrine therapy compared to them with endocrine therapy, however there were no changes in the level of triglyceride regardless of endocrine therapy. There were also no significant changes in total cholesterol and triglyceride levels between chemotherapy, radiotherapy and endocrine therapy. 10 year-risk score of ischemic heart disease was increased by 0.44%p in the final observation compared to that of a baseline.

Investigation of Correlations of Double Inversion Recovery and MR Spectroscopy on Breast MR Imaging (유방 자기공명영상에의 이중반전회복기법과 자기공명분광영상법의 상관관계 연구)

  • Ryu, Jung Kyu;Rhee, Sun Jung;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.34-42
    • /
    • 2014
  • Purpose : To evaluate the correlation of lesion-to-normal ratio (LNR) of signal intensity from double inversion recovery MR imaging and total choline-containing compound (tCho) resonance from single voxel MR spectroscopy in breast cancers. Materials and Methods: Between August 2008 and December 2009, 28 patients who were diagnosed as breast cancer and had undergone both double inversion recovery (DIR) MR imaging and MR spectroscopy (MRS) were included in this study. The signal intensities of the lesion (L) and ipsilateral normal breast tissue (N) were measured in region of interest of each breast cancer in DIR and contrast enhance MR image (CE-T1WI) to calculate the LNR value for each technique. MRS was performed using single-voxel MR spectroscopy. The height, width and area of tCho resonance were compared with each LNR of DIR and CE-T1WI. We used Pearson's correlation coefficient(r) for correlation analysis and the significance level was p=0.05. Results: There was no statistically significant correlation between LNR of CE-T1WI and height (r=-0.322, p=0.094), width (r=-0.233, p=0.232) and area (r=-0.309, p=0.109) of MRS tCho. There was no statistically significant correlation between LNR of DIR and height (r=0.067, p=0.735), width (r=-0.287, p=0.139) and area (r=0.012, p=0.953) of MRS tCho, either. The Pearson's correlation coefficient was 0.186 between LNRs of CET1WI and DIR (p=0.344). Conclusion: There was no statistically significant correlation between LNR of DIR and relative amount of tCho resonance of MRS.

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

The Irradiated Lung Volume in Tangential Fields for the Treatment of a Breast (유방암의 접선 조사시 피폭 폐용적)

  • Oh Young Taek;Kim Juree;Kang Haejin;Sohn Jeong Hye;Kang Seung Hee;Chun Mison
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.137-143
    • /
    • 1997
  • Purpose : Radiation pneumonitis is one of the complications caused by radiation therapy that includes a Portion of the lung tissue. The severity of radiation induced pulmonary dysfunction depends on the irradiated lung volume, total dose, dose rate and underlying Pulmonary function. It also depends on whether chemotherapy is done or not. The irradiated lung volume is the most important factor to predict the pulmonary dysfunction in breast cancer Patients following radiation therapy. There are some data that show the irradiated lung volume measured from CT scans as a part of treatment Planning with the tangential beams. But such data have not been reported in Korea. We planned to evaluate the irradiated lung volume quantitatively using CT scans for the breast tangential field and search for useful factors that could Predict the irradiated lung volume Materials and Methods : The lung volume was measured for 25 patients with breast cancer irradiated with tangential field from Jan.1995 to Aug.1996. Parameters that can predict the irradiated lung volume included; (1) the peruendicular distance from the Posterior tangential edge to the posterior part of the anterior chest wall at the center of the field (CLD) ; (2) the maximum perpendicular distance from the posterior tangential field edge to the posterior Part of the anterior chest wall (MLD) ; (3) the greatest perpendicular distance from the Posterior tangential edge to the posterior part of anterior chest wall on CT image at the center of the longitudinal field (GPD) ; (4) the length of the longitudinal field (L). The irradiated lung volume(RV), the entire both lung volume(EV) and the ipsilateral lung volume(IV) were measured using dose volume histogram. The relationship between the irradiated lung volume and predictors was evaluated by regression analysis. Results :The RV is 61-279cc (mean 170cc), the RV/EV is $2.9-13.0\%\;(mean\;5.8\%)$ and the RV/IV is $4.9-29.0\%\;(mean\;12.2\%)$. The CLD, the MLD and the GPD ave 1.9-3.3cm, 1.9-3.3cm and 1.4-3.1cm respectively. The significant relations between the irradiated lung volume such as RV. RV/EV, RV/IV and parameters such as CLD, MLD, GPO, L. $CLD\timesL,\;MLD\timesL\;and\;GPD\timesL$ are not found with little variances in parameters. The RV/IV of the left breast irradiation is significantly larger than that of the right but the RV/EVS do not show the differences. There is no symptomatic radiation pneumonitis at least during 6 months follow up. Conclusion : The significant relationship between the irradiated lung volume and predictors is not found with little variation on parameters. The irradiated lung volume in the tangential held is liss than $10\%$ of entire lung volume when CLO is less than 3cm. The RV/IV of the left tangential field is larger than that of the right but there was no significant differences in RV/EVS. Symptomatic radiation pneumonitis has not occurred during minimum 6 months follow up.

  • PDF

Acquisition of Monochromatic X-ray using Graded Multilayer Mirror (Graded 다층박막거울을 이용한 단색 엑스선 획득)

  • Ryu, Cheolwoo;Choi, Byoungjung;Son, Hyunhwa;Kwon, Youngman;Kim, Byoungwook;Kim, Youngju;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.205-211
    • /
    • 2015
  • At a recent medical imaging technology, the major issue of X-ray diagnosis in breast cancer is the early detection of breast cancer and low patient's exposure dose. As one of studies to acquire a monochromatic X-ray, Technologies using multilayer mirror had been preceded. However, a uniform multilayer mirror that consists of uniform thin-film thickness can acquire a monochromatic X-ray only in the partial area corresponds to angle of incidence of white X-ray, so there are limits for X-ray imaging technology applications. In this study, we designed laterally graded multilayer mirror(below GML) that reflects same monochromatic X-ray over the entire area of thin-film mirror, which have the the thickness of the linear gradient that correspond to angle of incidence of white X-ray. By using ion-beam sputtering system added the mask control system we fabricated a GML which has size of $100{\times}100mm^2$. The GML is designed to achieve the monochromatic X-ray of 17.5kev energy and has thin-film thickness change from 4.62nm to 6.57nm(3.87nm at center). It reflects the monochromatic X-ray with reflectivity of more than 60 percent, FWHM of below 2.6keV and X-ray beam width of about 3mm. The monochromatic X-ray corresponded to 17.5keV using GML would have wide application in development of mammography system with high contrast and low dose.