• Title/Summary/Keyword: 유방조직검사

Search Result 111, Processing Time 0.023 seconds

Usefulness of X-ray Guided Biopsy and Ultrasound Guided Biopsy in Breast Microcalcification Biopsy (유방 미세석회화 조직검사에서 X선 유도 하 조직검사와 초음파 유도 하 조직검사의 유용성)

  • Choi, Miseon;Song, Jongnam
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.201-206
    • /
    • 2016
  • Social interest in breast cancer has increased. The most basic exams for diagnosis include breast X-ray and breast ultrasound. In particular, breast microcalcification requires histological diagnosis, and breast microcalcification biopsy is commonly performed. Therefore, this study aimed to analyze and assess X-ray guided biopsy (needle localized open biopsy) and ultrasound guided biopsy (sono guided core needle biopsy), which are basics in diagnosis of microcalcification. Targeting 241 cases in which magnification mammography was performed for patients who visited the hospital due to breast microcalcification, age distribution and the location of lesions were analyzed in X-ray guided biopsy and ultrasound guided biopsy. By classifying exams performed after magnification mammography, the frequencies of X-ray guided biopsy and ultrasound guided biopsy were analyzed, and malignant and benign results were confirmed. The results showed that 64 cases(26.6%) were X-ray guided biopsy, which was 5.4 times higher than 12 cases(4.9%) of ultrasound guided biopsy. Due to development of ultrasound equipments, stereotactic vacuum-assisted biopsy, etc. the methods of histological diagnosis of microcalcification have become diverse, but when considering characteristics and limitations of each exam, X-ray guided biopsy is thought to be most accurate and useful.

Observation with Calcifications of Breast Tissue Phantoms Using Acoustic Resonance (공명현상을 이용한 유방조직 팬텀의 석회화 관찰)

  • Ha, Myeung-Jin;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.61-69
    • /
    • 2008
  • Diagnosis of breast ultrasound is better than mammography in the early detection of breast cancer, but, it is difficult to detect microcalcification. We studied on detection for calcification of breast tissue using acoustic resonance and power doppler with 7.5 MHz linear probe in breast ultrasound. We first constructed breast tissue phantom made of gelatin and saw breast, and then observed calcification by the change of external vibration. Calcification injected breast tissue phantom visualized the difference for brightness and region of color in ROI regions of power doppler. Acoustic resonance almost never visualized in low frequency regions, plateau constituted in about 300-400 Hz and colors vanished according to the increase of frequency.

  • PDF

Factor analysis using S-detect Method in Breast Ultrasound (유방 초음파 검사 시 S-detect 방법을 활용한 인자 분석)

  • Chun, Hye Ri;Jang, Hyon Chol;Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2019
  • This study aimed to investigate the performance of the S-detect method in breast ultrasonography and to determine how to reduce unnecessary biopsy by comparing the results of the S-detect method and biopsy. Thirty patients who had undergone breast ultrasonography between August and October 2018 and were scheduled to undergo biopsy because of the presence of breast nodules were retrospectively analyzed. The McNemar test was performed to determine whether detection of a malignant breast mass significantly differed between the S-detect method and biopsy. The following results were obtained from the analysis of the S-detect method: sensitivity, 90.9%; specificity, 84.21%; validity, 86.66%; positive predictive value, 76.92%; and negative predictive value, 94.11%. Analysis of the degree of agreement between the S-detect method and biopsy revealed a kappa value as high as 0.724 (p < 0.05), exhibiting good agreement between the two methods. The S-detect method in breast ultrasonography is diagnostically valuable in terms of distinguishing between malignant and benign breast masses, and if used properly before breast biopsy, unnecessary biopsy can be reduced.

The Study of Incidence Disease Categories on Breast Medical Examination in Some Area (일부지역 유방검사의 질환별 발생 빈도에 관한 연구)

  • Kwak, Byung-Joon;Im, In-Chul;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.357-363
    • /
    • 2007
  • The breast cancer occurrence have been increase yearly. Consequently the effort for early discovery or prevention is necessary. The study investigated the age distribution rate and a disease distribution occurrence rate in the breast medical examination of Ulsan city area. Breast medical examination distribution ratio it preferred the breast ultrasound with mamography 38.8% breast-ultrasonogrphy 61.2% to be investigated. The disease categories distribution was various from breast-ultrasound medical examination and it was investigated with becomes ramification. The reading find was many most infiltrating duct carcinoma from 40 age stage. The ductal carcinoma in situ was many from 50 age stage. The most many disease was investigated HP(Heterogenous dense nodule or mass parenchyma pattern) with 29.2%. Also the breast abscess or mastitis disease is confirmed only the breast-ultrasonography examination, even from the outside disease it was investigated with the fact that the breast-ultrasound raises the discrimination.

  • PDF

Evaluation of artifacts around the breast expander according to magnetic field strength (자장의 세기에 따른 유방 확장기 주위의 인공물 평가)

  • Jung, Dong- Il;Kim, Jae-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1144-1149
    • /
    • 2020
  • The magnetic valve of the breast tissue expander generates imaging artifacts during MRI examination, so MRI examination is limited. To evaluate the effect of imaging artifacts on the diagnosis area for patients with breast tissue expander who need MRI examination. Imaging artifacts were measured using self-made phantoms and actual clinical conditions. Imaging artifacts were measured differently depending on the environment of 1.5 Tesla and 3.0 Tesla, and the effects of imaging artifacts were less in the C-spine and L-spine tests. If MRI due to breast cancer metastasis is absolutely necessary, head & neck examination and L-spine can be examined mainly at 1.5 Tesla, but some sequences may cause distortion due to image artifacts. In terms of safety, MRI scans of patients with breast tissue expanders can be performed conditionally at 1.5T, avoiding 3.0T.

Diagnosis of Micro-Calcified Lesions of Breast Tissue Phantoms Using Acoustic Resonance Coupled with Power Doppler (공명현상과 파워도플러를 이용한 유방조직 팬텀의 미세 석회화 병변 진단)

  • Kim, Jeong-Koo;Ha, Myeung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.80-86
    • /
    • 2008
  • Breast ultrasound has many advantages over mammography but suffers from a shortcoming of being not suitable in detecting microcalcification. We studied on a method based on acoustic resonance and power Doppler to detect calcification of breast tissue using a typical 7.5 MHz linear probe used in breast ultrasound examination. We first constructed a breast tissue phantom made of gelatin and then observed calcified legions as external vibrations varied. Calcification injected to the breast tissue phantom being resonated different from the surrounding medium, and its acoustic resonance driven by external vibrations was visualized by differences for color brightness and area in ROI of power doppler. In low frequency regions, the acoustic resonance almost not appeared and showed a plateau in $300{\sim}600\;Hz$ and the color vanished as the frequency further increased.

A Study on the Quality of a Frozen Section of Breast Resection Margin during Breast-Conserving Surgery (유방 보존술 중 절제면 동결절편검사의 질 향상에 관한 연구)

  • Choi, Byung-Il;Chin, Su-Sie
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.3
    • /
    • pp.233-240
    • /
    • 2021
  • Evaluation of the resected margins of the frozen section during breast-conserving surgery can determine the presence of cancer cells in a short time and have a significant impact on the scope of surgery and the prognosis of the patient. However, breast tissue is composed of adipose tissue, which affects the accuracy of the test. In this study, a new method was applied to the resected surface of the frozen section in which wiping the surface of the frozen section block with alcohol was expected to expose the parenchyma to the surface as the adipose tissue would melt momentarily. Indeed, of the total of 98 cases, 37 cases showed a better exposure ratio of the parenchyma in the improved frozen section test than in the previous frozen section test. Of the 37 cases with increased visibility of parenchymal sections obtained by this method, two cases of ductal carcinoma in situ (DCIS) were detected. Although there are limitations such as turnaround time (TAT), the diagnostic accuracy of histopathologic examination of the frozen section may improve through this method and may have a direct impact on patient safety, and should therefore be researched further.

Digital Breast Tomosynthesis as a Breast Cancer Screening Tool for Women with Gynecologic Cancer (부인암을 가진 여성에서 유방암의 선별검사로서의 디지털 유방단층 촬영술)

  • Da-hoon Kim;Jin Chung;Eun-Suk Cha;Jee Eun Lee;Jeoung Hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.4
    • /
    • pp.886-898
    • /
    • 2020
  • Purpose The purpose of our study was to evaluate digital breast tomosynthesis as a breast cancer screening modality for women with gynecologic cancer. Materials and Methods This retrospective study included patients with underlying gynecologic malignancies who underwent screening digital breast tomosynthesis for breast cancer. The cancer detection rate, recall rate, sensitivity, specificity, and positive predictive value (PPV) were calculated. PPV1 was defined as the percentage of all positive screening exams that have a tissue diagnosis of cancer within a year. PPV2 was defined as the percentage of all diagnostic exams (and Breast Imaging Reporting and Data System category 4, 5 from screening setting) with a recommendation for tissue diagnosis that have cancer within a year. PPV3 was defined as the percentage of all known biopsies actually performed that resulted in a tissue diagnosis of cancer within the year. For each case of screen-detected cancer, we analyzed the age, type of underlying gynecologic malignancy, breast density, imaging features, final Breast Imaging Reporting and Data System assessment, histologic type, T and N stages, molecular subtype, and Ki-67 index. Results Among 508 patients, 7 with breast cancer were identified after a positive result. The cancer detection rate was 13.8 per 1000 screening exams, and the recall rate was 17.9%. The sensitivity was 100%, and the specificity was 83.2%. The false negative rate was 0 per 1000 exams. The PPV1, PPV2, and PPV3 were 7.7, 31.8, and 31.8, respectively. Conclusion Digital breast tomosynthesis may be a promising breast cancer screening modality for women with gynecologic cancer, based on the high cancer detection rate, high sensitivity, high PPV, and high detection rate of early-stage cancer observed in our study.

Comparison of Shear Wave Elastography and Pathologic Results Using BI - RADS Category for Breast Mass (유방종괴에 대한 BI-RADS범주를 이용한 횡탄성 초음파와 병리결과 비교분석)

  • An, Hyun;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.217-223
    • /
    • 2018
  • This study to search the diagnostic performance of shear wave elastography(SWE) in breast mass and to compare the biopsy result and stiffness obtained from shear wave elastography. Diagnostic breast ultrasonography and SWE were targeted for 157 patients who had breast ultrasonography was diagnosed mass from June 2017 to September 2017. Pathology results of 157 patients showed a benign 92 patients(Age, $44.54{\pm}11.84$) and a malignancy 65 patients(Age, $51.55{\pm}10.54$). Final evaluation, biopsy result, and quantitative SWE result were obtained and compared with each other according to Breast Imaging Reporting and Data System(BI-RADS) of diagnostic breast ultrasonography. Quantitative SWE value and pathologic result showed the highest diagnostic specificity of 83.70% in Emean and sensitivity of 89.23% in Emin. Quantitative SWE result and biopsy result is statistically significant.(p=0.000). The optimal cut-off value for malignant lesions was 66.3 kPa and 63.7 kPa, respectively, for the sensitivity, specificity, high maximum mean elasticity value(Emax) and mean elasticity value(Emean) and this showed the highest diagnostic area under the ROC curve(Az) value compared to other SWE measurement(p=0.000). The addition of SWE to conventional US in breast mass make a increase diagnostic specificity and reduce unnecessary biopsy. Therefore, it is expected that it will be helpful to analyze the breast mass using the above analysis and apparatus.

Interpretation of Image-Guided Biopsy Results and Assessment (영상유도하 조직검사의 해석과 판정)

  • Su Min Ha;Jung Min Chang
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.361-371
    • /
    • 2023
  • The success of image-guided breast biopsy depends on the biopsy method, needle selection, and appropriate technique based on the accurate judgment by the radiologist at biopsy. However, insufficient or inappropriate sampling of specimens may result in false-negative results or pathologic underestimation. Therefore, image-pathology concordance assessments after biopsy are essential for appropriate patient management. Particularly, the assessment of image-pathology concordance can avoid false-negative reports of breast cancer as a benign pathology. Therefore, this study aimed to discuss factors that impact the accurate interpretation of image-guided breast biopsy along with the appropriate assessments.