• Title/Summary/Keyword: 유발전위검사

Search Result 58, Processing Time 0.023 seconds

The Diagnosis and Ancillary Tests of Brain Death (뇌사의 진단과 진단을 위한 보조적 검사)

  • Kim, Cheon-Sik
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.1
    • /
    • pp.64-68
    • /
    • 2004
  • Brain death is defined as the irreversible cessation of all brain function. The diagnosis of brain death is primarily based on a careful neurological examination demonstrating unresponsiveness, absent of brain stem reflexes, and no respiratory activity. Several conditions which may mimic brain death must be excluded. In some cases investigations such as electroencephalography, angiography, transcranial doppler or evoked potentials can contribute to the diagnosis. The brief review will introduce medical technologist and clinician to the key issues in the definition and management of brain death.

  • PDF

Comparison of P300 between Schizophrenia and Bipolar Disorder (정신분열병과 양극성 장애의 P300 비교)

  • Park, In-Joon;Jeong, Hee-Yeon;Kwon, Young-Joon
    • Korean Journal of Biological Psychiatry
    • /
    • v.8 no.1
    • /
    • pp.123-130
    • /
    • 2001
  • Objective : Asymmetries in evoked potential P300 topography of schizophrenia and bipolar disorder are still controversial. The purpose of this study was to examine the difference in P300 topography between schizophrenia and bipolar disorder. Method : P300 was recorded from 16 schizophrenic, 15 bipolar manic, and 16 control subjects. All were right-handed. Subjects silently counted target stimuli(2.0kHz) among trains of standard stimuli(1.0kHz). Averages were constructed from brain responses to target stimuli. Results : 1) Schizophrenics displayed significantly smaller peak amplitude of P300 over Cz, Pz, T3 than controls. 2) Schizophrenics displayed significantly smaller peak amplitude of P300 over T3 than bipolar manics. 3) Schizophrenics displayed significantly smaller peak amplitude of P300 over T3 than their T4. 4) Schizophrenics displayed significantly delayed latency of P300 over T3 than bipolar manics. 5) Schizophrenics displayed significantly delayed latency of P300 over T3 than their T4. Conclusions : Left-sided P300 abnormality, especially left superior temporal gyrus, in schizophrenics relative to bipolar manics and controls suggests that psychophysiological cause of schizophrenia and bipolar disorder is different and P300 asymmetry is specific to the psychophysiological cause of schizophrenia.

  • PDF

The usefulness of diagnostic tests in children with language delay (언어 발달지연 환아에서 진단적 검사의 유용성)

  • Oh, Seung Taek;Lee, Eun Sil;Moon, Han Ku
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.3
    • /
    • pp.289-294
    • /
    • 2009
  • Purpose : To assess the usefulness of magnetic resonance imaging (MRI), karyotyping, brainstem auditory evoked potential (BAEP), electroencephalogram (EEG), tandem mass screening test, and newborn metabolic screening test in children with language delay for diagnosing underlying diseases. Methods : From January 2000 to June 2007, a retrospective chart review was performed for 122 children with language delay who visited the Child Neurology Clinic at Yeungnam University Hospital and who underwent neuropsychologic tests and other diagnostic evaluations for underlying diseases. They were grouped into phenomenological diagnostic categories, and test results were analyzed according to the underlying diseases. Results : Of 122 patients, 47 (38.5%) had mental retardation, 40 (32.8%) had developmental language disorders, 23 (18.9 %) had borderline IQ, and 12 (9.8%) had autism spectrum disorder. In 26 (21.3%) cases, the causes or relevant clinical findings to explain language delay were found. Eight (10.4%) of 77 MRIs, 6 (8.0%) of 75 EEGs, and 4 (5%) of 80 BAEPs showed abnormal results. Results directly attributed to diagnosing underlying diseases were 2 hearing defects in BAEPs and 1 bilateral perisylvian cortical dysplasia in MRIs. No abnormal results were found in karyotyping, tandem mass screening tests, and new-born screening tests. Conclusion : Commonly used tests to diagnose the cause of language delay are not very effective and should only be used selectively, according to patient characteristics. However, despite the low diagnostic yields from these tests, because many patients show abnormal results, these tests are useful when conducted in complete evaluation.

The Changes of VEP Values According to the Luminance Conditions and Refractive Errors in Normal Persons (정상인에서 조도와 굴절이상도에 따른 시유발전위 검사 값의 변화)

  • Leem, Hyun Sung;Lee, Koon Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.111-117
    • /
    • 2007
  • The visual evoke potential(VEP) is the effective method to diagnose and treat the amblyopia or to check the infants visual ability. In order to evaluate the changes of P100 latencies and amplitudes of VEP by intensity of illumination and refractive errors, we measured latencies and amplitudes of 41 normal adults (20/20 VA) who have no ocular diseases and neurologic diseases. The results were as follows: In the scotopic condition, the latencies were N75$75.83{\pm}3.69$ msec, P100$103.48{\pm}5.34$ msec, the P100 amplitude was $14.86{\pm}2.43$ msec, and in the photopic condition, the latencies were N75$76.71{\pm}3.11$ msec, P100$107.26{\pm}5.54$ msec and the P100 amplitude was $10.35{\pm}1.75$ msec. The latencies and amplitudes of P100 in the photopic condition had higher values than those in the scotopic condition and the measures were significantly different between the scotopic and photopic condition (p<0.01). The P100 latencies were delayed both in the scotopic and photopic condition with the refractive errors and those measures were delayed more than in the photopic condition. The P100 amplitudes in the induced myopic and hyperopic conditionsreduced than in the emmetopes in both illumination conditions. The P100 latencies and amplitudes in emmetropes showed a correlation with the induced myopic conditions in the scotopic condition. Those results showed that P100 latencies and amplitudes are dependent on the illumination conditions and refractive errors. And we suggest that those results would be useful to determine and evaluate the normal range for the person considering patients' refractive errors and illumination of the test room.

  • PDF

An Effective Transcranial Electric Motor-Evoked Potentials Method in Spinal Dural Arteriovenous Fistula Ligation Surgery (척수경막동정맥루 결찰술에서의 효과적인 경두개운동유발전위 검사방법)

  • Jang, Min Hwan;Lee, In Seok;Lim, Sung Hyuk
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.2
    • /
    • pp.193-198
    • /
    • 2021
  • The purpose of spinal dural arteriovenous fistula (SDAVF) ligation is to prevent neurological injury and the poor blood supply through ligation of arteriovenous fistula. Therefore, intraoperative neurophysiological monitoring (INM) is required via multimodal neurological examination for minimizing the side effects after surgery based on the patient's symptoms. Transcranial electric motor-evoked potentials (TceMEP) help to check the condition of the corticospinal tract. Whenever ligation is performed, TceMEP should be performed every minute to check for abnormalities. However, an examiner's lack of knowledge about the operation procedure and examination and also poor communication between the examiner and surgeon can cause incorrect timing of the stimulation of TceMEP that interferes with the procedure and causes side effects such as paralysis and motor weakness. As a result of this SDAVF ligation survey, it is believed that for proper INM, case reports will be needed along with further research and the examiner will also have to work closely with the surgeon to minimize neurological damage to patients.

The auditory evoked potential in premature small for gestational age infants (미숙아로 태어난 부당 경량아의 청각유발전위검사)

  • Moon, Il Hong;Ha, Kee Soo;Kim, Gui Sang;Choi, Byung Min;Eun, Baik-Lin;Yoo, Kee Hwan;Hong, Young Sook;Lee, Joo Won
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.12
    • /
    • pp.1308-1314
    • /
    • 2006
  • Purpose : This study aimed to evaluate the usefulness of auditory evoked potential (AEP) in clarifying neuronal development in premature small for gestational age (SGA), and appropriate for gestational age (AGA) infants. Methods : A total of 183 premature infants who were born from August 2002 to July 2005, were examined with AEP. They were divided into three groups; AGA, symmetric-SGA and asymmetric-SGA group. Results : Statistically significant differences in the head circumference were observed in three groups. Among the risk factors, prevalence of hypoglycemia and hypoalbuminemia between AGA and asymmetric SGA infants were significantly different. V absolute peak latency (APL) in the right side of AGA infants was delayed were than that of asymmetric SGA infants. III-V interpeak latency (IPL) of asymmetric SGA infants was delayed more than that of symmetric SGA infants. Moreover, I-V IPL on both sides of symmetric SGA infants was shortened more than that of AGA infants. However, all the results of AEP were within the reference range, according to gestational age. Birth weight of, only asymmetric SGA, was related to the III APL on both sides and the III-V IPL on right side. Conclusion : This study shows that the values of APL and IPL of premature SGA infants are different than that of premature AGA infants. These data could be an indicator in evaluating the neurologic functions of small for gestational age infants.

Review of Somato Sensory Evoke Potential Test (체성감각유발전위검사에 대한 고찰)

  • Kim Myung-Chul;Kim Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.4
    • /
    • pp.64-74
    • /
    • 2002
  • The SSEP(SomatoSensory Evoke Potentials) test is a valid and repeatable technique which correlates with clinically assessed joint position & vibration sense, skin touch & pressure sense. Also SSEP study is a simple and quantitative test, and has been used to evaluate the sensoty system along the somatosensory pathway from peripheral sensory receptor to the cortex. The ascending pathway of SSEP has been know to be posterior column-lemniscal pathway, but not without controversy. There are two kind of test mathods : one of test is median nerve SSEP and other test is posterior tibial nerve SSEP. Recently, SSEP used to performed to evaluate the usefulness of dermatomal SSEP(D-SSEP) and segmental SSEP(5-SSEP) for the diagnosis of lumbasacral radiculopathy, and it can be measure of ingual ahd palatine evoked potentials & indicator of medullary function useful for the diagnosis of brain death.

  • PDF

Clinical Somatosensory Evoked Potential (임상 체성감각 유발전위 검사)

  • Ryoo, Jae-Kwan;Kim, Jong-Soon
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.1
    • /
    • pp.907-918
    • /
    • 1996
  • Evoked potentials(EP) are defined as electric responses of the nerves system to sensory stimulation. EPs are used mainly to test conduction in the visual, auditory, and somatosensory systems, especially in the central parts of these systems. Somatosensory evoked potentials (SEP) are the potentials elicited by stimulation of peripheral nerves and recorded at various sites along the sensory pathway. SEPs types consist mainly of SEPs to electric stimulation of arm or leg nerves. SEPs to arm stimulation are usually recorded simultaneously from clavicular, cervical, and scalp electrodes; SEPs to leg stimulation are recorded from lumbar, low thoracic, and scalp electrodes. Subject variables that have practical impotance are age, limb length, body height, and temperature. General clinical interpretation of abnormal SEPs wave decreases of peripheral conduction time, and abolition of SEPs recorded from different levels to identify lesions of peripheral nerves, plexus, nerve root, spinal cord, cauda equina, hemispheric brainstem, and cerebral parts of the somatosensory pathway.

  • PDF

The Effect of Differences in Age and Sex on Vestibular Evoked Myogenic Potentials (연령과 성별의 차이가 전정 유발근전위에 미치는 영향)

  • Moon, Sung-Sik;Kim, Kyoung-Mi;Kim, Young-Ji;Kim, Young-Hwal
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.2
    • /
    • pp.136-140
    • /
    • 2007
  • The aim of this study was to examine the effect of differences in age and sex on vestibular evoked myogenic potentials (VEMP), particularly in normal participants. Briefly, the VEMP is a response elicited by loud clicks or tone bursts recorded from the tonically contracted sternocleidomastoid muscle. A total of 72 participants were divided into 6 groups according to their age and sex (20~30/F, 20~30/M, 40~50/F, 40~50/M, ${\geq}60/F$, ${\geq}60/M$). We got the data of latency, amplitude, and asymmetry index of the amplitude(ASI) from them. As a result of this study, there are variations in VEMP amplitudes and ASI depending on the muscle tension and the intensity of stimuli. In contrast, the latency of the response is usually less varied and does not differ significantly.

  • PDF

Motor Evoked Potential Study with Magnetic Stimulation in Ischemic Stroke Patients (허혈성 뇌졸중 환자에서 Magnetic Stimulation에 의한 운동유발전위 반응)

  • Kim, Seong-Min;Suh, Sang-Dug;Lee, Jun;Hah, Jung-Sang
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.2
    • /
    • pp.248-261
    • /
    • 1994
  • This study was undertaken to evaluate the clinical usefulness of magnetic motor evoked potential (MEP) in the diagnosis of stroke and predicting the motor improvement following stroke. The cortical, cervical and lumbar stimulations were performed in the case of 24 healthy controls and 24 ischemic stroke patients. The central motor conduction time (CMCT) was represented by the difference of latency to a target muscle between after transcranial stimulation and after cervical or lumbar stimulation. There was no case showing no response in controls. But in 11 out of 24 ischemic patients, we could not get cortical MEP. Mean CMCT of abductor pollicis brevis muscle was not significantly different in controls and stroke patients in whom MEPs were recorded. There were significant differences between mean CMCT of normal controls and that of stroke patients showing MEPs in AH Muscle. MEP Results from testing the stroke patients were correlated with site of lesion, degree of motor weakness and motor improvement after 1 to 2 months. These results suggest that magnetic MEP is easy and useful in electrophysiological test of central motor pathway and is useful indicator for representing the motor weakness and predicting the motor outcome in acute ischemic stroke patients.

  • PDF