• Title/Summary/Keyword: 유류소비비용

Search Result 8, Processing Time 0.031 seconds

Evaluation of Effect on CFS Location (CFS 입지에 따른 경제적 효과 평가)

  • Song, Yong-Seok;Nam, Ki-Chan;Kwak, Kyu-Seok
    • Journal of Navigation and Port Research
    • /
    • v.28 no.1
    • /
    • pp.69-74
    • /
    • 2004
  • Container Freight Station(CFS), which would be located inside terminal or outside, plays the role of consolidating less than container load(LCL) cargo gathered from multi shippers and deconsolidating full container load cargo into individual consignment. When CFS is allocated inside terminal it muses several problem such as traffic gam around terminal, high social and logistics cost and deterioration of terminal condition. This study, therefore, tries to evaluate the location of CFS, inside and outside of terminal, with respect to the social and logistics costs.

Rockets and Feathers Across Multi-Gasoline Products: Evidence from Error Correction Model (수송용 유류제품의 제품별 비대칭성에 관한 연구: 오차수정모형을 통한 접근)

  • Chang, Yenjae;Kim, Dae-Wook
    • Environmental and Resource Economics Review
    • /
    • v.25 no.4
    • /
    • pp.495-516
    • /
    • 2016
  • This study empirically examines how asymmetric price adjustment of the retail gas price happens differently for various oil products, such as high-grade gasoline, regular gasoline, and diesel, by employing asymmetric error correction model within weekly data set from 2010~2015. Our estimation results show that the price adjustment, across the all oil types, predicated on shifting crude oil and wholesale oil prices is asymmetric. In addition, the duration of asymmetry was shorter in high-grade gasoline case than in other oil types. This took place by rapid price adjustment of high-grade gasoline price when faced with both cost increases and decreases, in comparison with regular gasoline and diesel cases. There results were attributed by characteristics of the consumer group and a high retail-wholesale margin of high-grade gasoline.

A Study on the Optimal Tax of Gasoline in Korea (외부성을 고려한 최적 휘발유세에 대한 연구)

  • Choi, Bongseok;Jung, Yong Hun
    • Environmental and Resource Economics Review
    • /
    • v.23 no.2
    • /
    • pp.225-248
    • /
    • 2014
  • The purpose of this study is to estimate the optimal tax rate for gasoline in Korea, by utilizing both the parameters for the estimation of the optimal fuel taxes and the theoretical model considering externalities proposed by Parry and Small (2005). The result of simulation shows that the optimum fuel taxes in Korea is calculated in 382 korean won per liter, which is lower than fuel tax rate(529 korean won per liter) currently being imposed. The fuel tax is composed of two types of tax. First is Pigouvian tax caused by negative externality such as traffic congestion and accidents etc. And second is Ramsey tax for optimal commodity sales taxes. We find that Pigouvian tax in Korea is higher than one of U.S. and U.K and Ramsey tax is very small due to the inelastic labor supply comparing to consumption elasticity of fuel. When adjusting the elasticity of labor supply to the UK level, the optimal fuel tax in Korea is very close to the current level of 480 korean won per liter. This paper contributes to suggest the reasonable estimation and discussion in the social optimum fuel tax rates by utilizing the theory and simulation and improve the possibility of the derivation of optimum fuel taxes through both securing the exact parameters and modifying the theoretical model suitable for Korea.

Economic analysis on the applications of shipboard LED luminaires (선박용 LED 등기구의 적용에 따른 경제성 분석)

  • Park, Seo-Jun;Byeon, Sung-Hwan;Kim, Sun-Jae;Park, Kyoung-Soo;Kil, Gyung-Suk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.342-347
    • /
    • 2016
  • This paper dealt with the economic analysis on the application of shipboard LED (Light Emitting Diode) luminaires to replace incandescent and fluorescent lamps, which account for over 80 % of light source on a training or naval vessel. The rates of savings achieved in the power consumption, initial investment, maintenance cost, and fuel cost were analyzed. The break-even points and the $CO_2$ emissions were also calculated. For the training vessel, the initial investment was increased by 3.8 times, while the maintenance cost over five years was reduced by 51 %. When 40 %, 50 %, and 60 % of luminaires were turned on, the calculated break-even points were 11 months, 9 months, and 7 months, respectively. On the other hand, the initial investment was increased by 3.5 times while the maintenance cost over five years was saved by 55 % for the naval vessel. The break-even points were calculated as 15 months, 12 months, and 10 months, respectively. Moreover, the $CO_2$ emissions of the training and the naval vessels were reduced by 69 % and 65 %, respectively. From the results, it was revealed that the maintenance cost can be reduced by more than 50 %, and that the power consumption, fuel cost, and $CO_2$ emissions can be reduced by more than 60 % if LED luminaires are used on two types of vessels.

Internalizing Environmental Cost using TDM Alternatives (교통수요관리 기법을 활용한 환경오염비용의 내부화 방안연구)

  • 김운수;엄진기;황기연;장지희
    • Journal of Korean Society of Transportation
    • /
    • v.17 no.4
    • /
    • pp.99-110
    • /
    • 1999
  • With a growing awareness, transportation is the maior source of urban air pollution. Planners and policy-makers are strongly urged to care the impacts of transportation management strategies on environment. Since transport-related air Pollution can be regarded as negative externalities of transport, it is indispensable to evaluate chanties in air quality which seems to occur when proposed transport measures are implemented. In addition, transport measures should be integrated in a set of combined Paradigm regarding transport and environment. Based on the integrated Paradigm between transportation demand management(TDM) and environmental planning, the main focus is given to apply environment cost internalizing measures to the short-term congestion management Program(SCMP) in Seoul, that has been developed in 1998 by Seoul Development Institute. Three modules are analyzed: without and/or with ₩500, ₩1000 emission plus gas tax, respectively. From the empirical applications on Seoul city, one of the most exemplary findings in SCMP program is that, emission plus gas tax can be a very useful measure to reduce vehicular emissions by targeting major Pollutants differently, rather than by dealing with pollutants collectively. Further research that provides (1)showing the spatial variation of pollution levels along the intersections, (2)more developing combined Paradigm between transport, land use, and environment, (3)using environmental road capacity rather than Physical-aspects of road capacity, and (4)continuing R&D on air quality constrained TDM, can contribute significantly to applications of the real and efficient environment-constrained transportation planning.

  • PDF

CO2 emission Reduction and Load factor improvement of Power Systems, using Geothermal Source Heat Pump (지열히트펌프 활용을 통한 전력계통 부하율 향상 및 CO2 감축)

  • Lee, Geon-Woo;Lee, Sang-Joong;Yang, Seong-Deog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.349-354
    • /
    • 2008
  • August 2008, Our country was announced the Energy Vision 2030 for strengthening response capability climate change by the greenhouse effect, 'Stable supply of energy' and 'Efficient systems'. According to the report, Our country is the world's top 10 is a country that consumes a lot of energy. and more than 97% of the energy because it is dependent on foreign imports, The importance of NRE(New and Renewable Energy) is rising significantly, This paper was applied geothermal heat pump it one kind of the renewable energy equipment, in General buildings, and analyzed the effect of the installation. Thus, to improve the load factor of the Electric power system was proposed, and As a result, can be expected the energy cost savings and the reduction of greenhouse gases, through Economic electric power supply.

  • PDF

Reforming Environmentally-Harmful Subsidies in the Energy and Electricity Sectors in Korea (우리나라 에너지·전력 부문 보조금의 환경친화적 개편 효과 분석 : 연산일반균형분석을 중심으로)

  • Kim, Seung-Rae;Kang, Man-Ok
    • Environmental and Resource Economics Review
    • /
    • v.20 no.4
    • /
    • pp.827-858
    • /
    • 2011
  • In Korea, various environmentally harmful subsidies are granted in agriculture, fishery, energy, electricity, transportation, steel and shipbuilding industry. Examples include tax-exempt fuel for agriculture & fishery, VAT- exemption for briquette & anthracite, temporary subsidy for fuel, production stabilizing subsidy for coal mining, subsidy for briquette. Korea's yearly total subsidy in energy area is about 5,291 billion won, among them is 4,870 billion won. To reduce air pollutants and to mitigate climate change, Korea has to review the phase-out of environmentally harmful subsidies and the phase-in of environment-friendly subsidy. The reduction or removal of environmentally harmful subsidies will enhance economic efficiency and bring about environmental benefits. Economic efficiency means less use of inputs, which reduces environmental cost and improves social benefits. This paper applies the Shoven and Whalley's model to the Korean economy and analyzes the general equilibrium incidence effects of reforming environmentally harmful subsidies in the energy and electricity in Korea. We consider several counterfactual scenarios in which current environmentally harmful subsidies are reduced or abolished, compare them with the reference case in the economy, and evaluated the change in efficiency costs and distributional incidence of tax reforms related to subsidies.

  • PDF

Comparison of Heating Characteristics of Electric Heating Element Heater and Oil Hot Air Heater in Single Span Greenhouses (전기발열체 난방기 및 유류온풍 난방기의 단동온실 난방 특성 비교)

  • Kwon, Jin Kyung;Kim, Seung Hee;Shin, Young An;Lee, Jae Han;Park, Kyeong Sub;Kang, Youn Koo
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.324-332
    • /
    • 2017
  • The comparative experiments were conducted for single span greenhouses where cucumbers were cultivated to analyze the effect of heating between a carbon fiber electric heating element heater and an oil hot air heater in terms of the inside climate, energy consumption and plant growth. In order to analyze the effect of heating capacity, 6, 9, and 16 kW of electric powers were supplied to the electric heating element for same setting temperature of 15?. As a result, as the heating capacity increased, the number of ON-OFF cycles of the electric heating element and the temperature inside the greenhouse increased proportionally. In the comparison of two heaters, it was shown that the temperature and relative humidity distributions of the electric heating element installed greenhouse was much uniform than those of the oil hot air heater installed greenhouse. The heating energy consumptions during the heating period of 79 days were 867L for the oil hot air heater and 8,959 kWh for the electric heating element heater, and the heating costs were 607 and 403 thousand won respectively. In the electric heating element installed greenhouse, the cucumber growth was slightly better and the yield was 4.3% higher than those of the oil hot air heater installed greenhouse, but there were no statically significant difference in the cucumber growth and yield between greenhouses.