• Title/Summary/Keyword: 유량변화정도 분석

Search Result 220, Processing Time 0.035 seconds

An Assessment of the Best Estimate Thermal-Hydraulic Analysis Code CATHARE on CREARE Downcomer Experiment (CREARE Downcomer실험에 대한 최적열수력 분석용 전산코드 CATHARE의 검증)

  • Chang, Won-Pyo;Lee, Jae-Hoon;Kim, Dong-Su;Chae, Sung-Ki
    • Nuclear Engineering and Technology
    • /
    • v.24 no.3
    • /
    • pp.274-284
    • /
    • 1992
  • A 1/15-scale CREARE experiment, which simulates the thermal-hydraulic behavior in the reactor pressure vessel of a PWR during a hypothetical Loss Of Coolant Accident, has been analyzed using CATHARE code for the associated model assessment to represent the phenomenon. The key parameters examined in the CREARE experiment were known as ECC water injection rate. ECC water subcooling, system pressure, and steam flow rate coming out from the core bottom. The present CATHARE simulation, however, has been mainly focused on qualitative analysis of a countercurrent flow in the downcomer. The discrepancy of the simulation results with the experimental data is considered arising primarily from an inadequate numerical representation as well as an interfacial friction model. Accordingly it is suggested from the sensitivity studies that either multidimensional approach or further examination of momentum equations at a junction near a volume element in CATHARE be necessary in order to represent the phenomenon more realistically.

  • PDF

A numerical study on the aerodynamic characteristics of a variable geometry throttle valve(VGTV) system controlling air-flow rate (유량 제어장치인 가변스로틀밸브의 기하학적 형상변화에 따른 공기역학 특성분석 연구)

  • Cho, Hyun-Sung;Kim, Chul-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.378-383
    • /
    • 2013
  • A butterfly throttle valve has been used to control the brake power of an SI engine by controlling the mass flow-rate of intake air in the induction system. However, the valve has a serious effect on the volumetric efficiency of the engine due to the pressure resistance in the induction system. In this study, a new intake air controlling valve named "Variable Geometry Throttle Valve(VGTV)" is proposed to minimize the pressure resistance in the intake system of an SI engine. The design concept of VGTV is on the application of a venturi nozzle in the air flow path. Instead of change of the butterfly valve angle in the airflow field, the throat width of the VGTV valve is varied with the operating condition of an SI engine. In this numerical study, CFD(computational fluid dynamics) simulation technique was incorporated to have an aerodynamics performance analysis of the two air flow controlling systems; butterfly valve and VGTV and compared the results to know which system has lower pressure resistance in the air intake system. From the result, it was found that VGTV has lower pressure resistance than the butterfly valve. Especially VGTV is effective on the low and medium load operating condition of an SI engine. The averaged pressure resistance of VGTV is about 49.0% lower than the value of the conventional butterfly throttle valve.

Development of a Solar Powered Water Pump by Using Low Temperature Phase Change Material ­ System Construction and Operation Analysis ­ (저온 상변화 물질 특성을 이용한 태양열 물펌프 실용화 연구개발(II) ­시스템 구성 및 작동분석)

  • 김영복;이양근;이승규;김성태;나우정;민영봉
    • Journal of Animal Environmental Science
    • /
    • v.9 no.2
    • /
    • pp.69-78
    • /
    • 2003
  • In this study, the energy conversion equipment from the radiation energy to mechanical energy by using n­pentane as the operating fluid was constructed and the performance to pump the water was tested for the utilization of solar powered water pump. The equipment was designed optimally, after the theoretical analyses of the water pumping head and water quantity per cycle were done. The pentane vapour temperature in the condenser and the temperature of the outlet water from the condenser became lowered and the heat transfer rate became higher with decreasing the water inlet level to the condenser. The temperature difference between the condenser and the water tank was significant. Therefore, the distance between the water tank and condenser was recommended to be shorten and the diameter of their connecting pipe was recommended to be narrow in order to reduce the resistance of the fluid passage and improve the heat transfer rate. The amount of water pumped was 1.6­2.4 liters. Mass flow rate of the cooling water became lowered when the cooling water pipe was prolonged from the condenser to improve the heat transfer rate.

  • PDF

Characteristics of Transformation Process of Wastewater in Sewer (하수관거내 오염물질 성상변화 특성)

  • Lee, Doo-Jin;Kim, Moon-Il
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.9
    • /
    • pp.911-916
    • /
    • 2005
  • In this study, variations of water quality, sediment size and contaminant substances are analyzed at upstream and downstream in sewer systems in order to evaluate the characteristics of wastewater transformation by physico-chemical and biological reactions. The differences of DOC concentration between up and down stream showed the range of $-5.8{\sim}18.6$ from the result of continuous measurement at up and down stream. About 8.4% of DOC concentration was reduced and reduction rate was 2.3 mg/L/km. SS reduction rate was measured by 5.5 mg/L/km, 0.22 mg/L/min from upstream to downstream, which was twice than DOC reduction rate. When pollution load reduction was evaluated considering infiltration/inflow effect, DOC load was eliminated from 1,230 ka/d to 1,167 kg/d by physi-chemical and biological reaction in a sewer and 7.8% of the SS in upstream station was reduced under dry weather condition. The results showed that the characteristics of transformation process of wastewater in sewer should be considered for design and operation of wastewater treatment plant.

Hospice and Palliative Care for the Terminal Patients with Colorectal Cancer (말기 대장직장암 환자의 호스피스 완화의료)

  • Hong, Young-Hwa;Lee, Choon-Sub;Lee, Ju-Ri;Lee, Jung-Ho;Kim, You-Jin;Lee, Tae-Kgyu;Moon, Do-Ho
    • Journal of Hospice and Palliative Care
    • /
    • v.10 no.1
    • /
    • pp.35-42
    • /
    • 2007
  • Purpose: Colorectal ranter is the 4th leading cause of cancer death in Korea and the prevalence is increasing continuously. This study was aimed to figure out the problems through the clinical consideration about terminal colorectal ranter patients who had died in hospice unit. Methods: We retrospectively reviewed the medical records in 78 patients with colorectal ranter who had admitted, received palliative care, and died in a hospice unit between April 2003 and November 2006. Results: The median age of patients was 59.6 years with 45 men (58%) and 24 women (42%). The median survival in hospice and palliative care was 36 days. The median hospitalization was 22 days. The most prevalent reason for admission was pain (38 patients, 49%), and the most common symptom was also pain (70 patients, 90%). Forty eight patients (62%) took analgesics before hospice referral. Twenty seven patients (65%) of 45 patients with intestinal obstruction have been performed palliative procedures. Median survival of patients with palliative procedure was higher than that of no palliative procedure group (47 days vs 19 days, P-value=0.005). Conclusion: The duration of hospice and palliative care was not enough to care the terminal colorectal cancer. Therefore, we suggest that proper education and information should be provided to physician, patients and their family members for effective hospice and palliative care.

  • PDF

Characteristic of PECVD-$WN_x$ Thin Films Deposited on $Si_3N_4$ Substrate ($Si_3N_4$ 기판 위에 PECVD 법으로 형성한 Tungsten Nitride 박막의 특성)

  • Bae, Seong-Chan;Park, Byung-Nam;Son, Seung-Hyun;Lee, Jong-Hyun;Choi, Sie-Young
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.7
    • /
    • pp.17-25
    • /
    • 1999
  • Tungsten nitride($WN_x$) films were deposited by PECVD method on silicon nitride($WSi_3N_4$) substrate. The characteristics of $WN_x$ film were investigated with changing various processing parameters ; substrate temperature, gas flow rate, rf power, and different nitrogen sources. The nitrogen composition in $WN_x$ film varied from 0 to 45% according to the $NH_3$ and $N_2$ flow rate. The highest deposition rate of 160 nm/min was obtained for the $NH_3$ gas and relatively low deposition rate of $WN_x$ films were formed by $N_2$ gas. $WN_x$ films deposited on $WSi_3N_4$ substrate had higher deposition rate than that of TiN and Si substrates. The purity of $WN_x$ film were analyzed by AES and higher purity $WN_x$ films were deposited using $NH_3$ gas. The XRD analysis indicates a phase transition from polycrystalline tungsten(W) to amorphous tungsten nitride($WN_x$), showing improved etching profile of $WN_x$ films Thick $WN_x$ films were deposited on various substrates such as Tin, NiCr and Al and maximum thickness of $1.6 {\mu}m$ was obtained on the Al adhesion layer.

  • PDF

The Time Responses of Spirometric Values in Response to Single Doses of Inhaled Salbutamol (기관지확장제 사용 후 시간에 따른 폐활량 측정치의 변화)

  • Park, Sun Hyo;Choi, Won-Il;Lee, Sang Won;Park, Hun Pyo;Seo, Yong Woo;Ku, Duk Hee;Lee, Mi Young;Lee, Choong Won;Jeon, Young June
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.2
    • /
    • pp.144-150
    • /
    • 2004
  • Background : An assessment of the presence and the degree of reversibility of airflow obstruction is clinically important in patients with asthma or chronic obstructive pulmonary disease. However, the time responses of spirometric parameters in response to bronchodilator have not been well investigated. Methods: We studied 15 patients with asthma. Spirometric and mini-Wright peak expiratory flow measurements were performed at 15, 30, 45, and 60 minutes after using single dose($200{\mu}g$) of inhaled bronchodilator, salbutamol. Results : The mean values of forced expiratory volume in one second($FEV_1$) and forced vital capicaty(FVC) were significantly increased at 60 minutes after using bronchodilator in comparison to 15 minutes. And peak expiratory flow rate measured by either mass flow sensor or mini-Wright peak flow meter were significantly increased at 45 minutes after using bronchodilator in comparison to 15 minutes. Conclusions : To appropriate evaluation of the bronchodilator response in patients with reversible airflow limitation, it would be useful measuring either $FEV_1$ or PEF at the later time point 60 or 45 minutes in comparison to 15 minutes after using bronchodilator.

A Study on Characteristics of Precipitated Calcium Carbonate Prepared by the Nozzle Spouting Method (분사법으로 제조된 침강성 탄산칼슘 특성에 관한 연구)

  • Park, Joo-Won;Kim, Joon-Seok;Ahn, Ji-Whan;Han, Choon
    • Applied Chemistry for Engineering
    • /
    • v.17 no.1
    • /
    • pp.67-72
    • /
    • 2006
  • Precipitated calcium carbonate (PCC) was prepared in a cylindrical reactor by the nozzle spouting method. The reactor was filled with $CO_2$ and $Ca(OH)_2$ suspensions were circulated through a nozzle to prepare PCC. This method has several advantages such as provision of large contact area between suspension and $CO_2$ and production of large number of nuclei in short time. By changing suspension concentrations, suspension temperature, flow rates of $CO_2$ and nozzle sizes, PCC from homogeneously dispersed $0.1{\mu}m$ to heterogeneous $0.3{\mu}m$ can be obtained. According to XRD analyses, most PCC formed was calcite with small amount of aragonite depending on the reaction conditions. Usually, the reaction proceeded at high pH and electric conductivities initially. Then, pH and electric conductivities decreased rapidly to the saturation condition. Results indicated that the specific conditions (temperature: $25^{\circ}C$, suspension concentration: 0.5 wt%, $CO_2$ flow rate: 1 L/min, nozzle size: 0.4 mm) were required to prepare uniform particle size (particle diameter: $0.1{\mu}m$) of PCC.

난방운전의 최적제어방안 중심 공동주택의 열성능 향상 방안

  • 이승언;안태경;강재식
    • 월간 기계설비
    • /
    • s.46
    • /
    • pp.74-89
    • /
    • 1994
  • 현재 범국가적 차원에서 지속적인 국가 경제 발전과 국제수지 개선을 위하여 추진되고 있는 정부의 에너지 절약사업에서 건물부문이 차지하는 에너지절약 효과는 막중하다. 특히 전체주택에서 공동주택이 차지하는 비율은 1990년에 32.1$\%$, 서울시의 경우 51.3$\%$로 전체 주택의 과반수를 넘어섰으며, 수도권의 대단위 아파트단지의 개발과 함께 공동주택의 증가추세는 당분간 지속될 전망이다. 본 연구는 공동주택의 최적난방 운전기법 개발을 위한 1차년도의 연구로서 현행 공동주택의 난방운전 실태를 조사, 분석하고 각 난방법에 따른 문제점 및 최적제어 알고리즘의 개발을 위한 자료 도출을 주 목적으로 진행되었다. 1차년도에 수행된 연구의 주요 내용을 살펴보면 다음과 같다. 공동주택의 난방에너지 소비현상은 단지에 따라 최대 3배이상의 열사용량에 차이가 있는 것으로 나타났다. 열사용량의 차이는 건축의 기본 열성능, 설비시설의 수준 및 노후화정도에 영향을 받으나 동일 연대의 단지들에서도 최대 80$\%$이상의 열사용량이 차이를 보이고 있었으며 이는 기계실 및 각 세대의 난방운전방법 및 제어수준에 따른 것으로 평가되었다. 세대의 층별, 위치별 열사용량 분석에 의하면 층별 열사용량차이가 큰 것으로 분석되었으며, 특히 최상층부와 최하층부의 열사용량이 뚜렷이 많이 나타나 단열성능의 강화가 요구되는 것으로 나타났다. 한편 샘플단지에 대한 측정 데이터를 통해 적정 열량공급시간대의 설정과 외기온의 변화에 따른 적정 온수공급온도의 설정조건 및 유량제어 효과등에 대한 분석 및 검토를 하였으며, 이를 통해 2차년도의 개발목표인 최적운전제어 방안의 제시를 위한 자료를 구축하였다. 또한 각 세대의 기밀성능이 공동주택의 열성능에 미치는 영향을 도출하기 위하여 샘플단지에 대해 트레스가스 측정법과 Blower Door법에 의하여 환기 및 기밀상태를 평가 하였으며 측정주호에 대한 환기를 예측할 수 있는 환기예측평가식을 제시하였다.

  • PDF

Continuity Simulation and Trend Analysis of Water Qualities in Incoming Flows to Lake Paldang by Log Linear Models (로그선형모델을 이용한 팔당호 유입지류 수질의 연속성 시뮬레이션과 경향 분석)

  • Na, Eun-Hye;Park, Seok-Soon
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.3 s.104
    • /
    • pp.336-343
    • /
    • 2003
  • Two types of statistical models, simple and multivariate log linear models, were studied for continuity simulation and trend analysis of water qualities in incoming flows to Lake Paldang. Water quality is a function of one independent variable (flow) in the simple log linear model, and of three different variables (flow, time, and seasonal cycle) in multivariate model. The independent variables act as surrogate variables of water quality in both models. The model coefficients were determined by the monthly data. The water qualities included 5-day Biochemical Oxygen Demand ($BOD_5$), Total Nitrogen (TN), and Total Phosphorus (TP) measured from 1995 to 2000 in the South and the North branches of Han River and the Kyoungan Stream. The results indicated that the multivariate model provided better agreements with field measurements than the simple one in a31 attempted cases. Flow dependency, seasonality, and temporal trends of water quality were tested on the determined coefficients of the multivariate model. The test of flow dependency indicated that BOD concentrations decreased as the water flow increased. In TN and TP concentrations, however, there were no discernible flow effects. From the temporal trend analyses, the following results were obtained: 1) no trends on BOD at all three upstreams, 2) increase on TN at the South Branch and the Kyoungan Stream, 3)decrease on TN at the North Branch,4) no trends on TP at the North and the South Branches and 5) increase on TP at the Kyoungan Stream by 3 to 8% per years. The seasonality test showed that there were significant seasonal variations in all three water qualities at three incoming flows.