• Title/Summary/Keyword: 유량공급장치

Search Result 153, Processing Time 0.024 seconds

Fuel cell system for SUAV using chemical hydride - I. Lightweight hydrogen generation and control system (화학수소화합물을 이용한 소형 무인항공기용 연료전지 시스템 연구 - I. 경량 수소 발생 및 제어 장치)

  • Hong, Ji-Seok;Jung, Won-Chul;Kim, Hyeon-Jin;Lee, Min-Jae;Jeong, Dae-Seong;Jeon, Chang-Soo;Sung, Hong-Gye;Shin, Seock-Jae;Nam, Suk-Woo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.3
    • /
    • pp.226-232
    • /
    • 2013
  • A compact hydrogen generation device of fuel cell system using chemical hydride storage technique was designed to fit the propulsion device requirement of a small unmanned aerial vehicle(SUAV). For high efficient, compact, and lightweight hydrogen generation control device, the Co-B catalyst hydrogen conversion rate by $NaBH_4$ aqueous solution flux is measured so that the proper amount of Co-B catalyst for maximum hydrogen generation of 100W stack was proposed. A compact hydrogen generation device is controlled by pump's on/off using its own internal pressure and consumes fuel in high efficiency through a dead-end type fuel cell. The fuel cell system has stable operation for a planed flight profile. The system operates up to maximum 7 hours and at least 4 hours for tough flight profiles.

Core Technology Development of Low Temperature Fluidity Test System with Composited Fuel Filter (통합연료필터의 저온유동성 시험장치 핵심기술개발)

  • Yun, Suck-Chang;Zhao, Xiang;Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.18 no.3
    • /
    • pp.420-426
    • /
    • 2014
  • In this paper, we have implemented the low temperature fluidity test system with the composited fuel filter and heater, which has tested the low temperature fluidity of gasoline, an engine start time, the consumption of electricity and power to evaluate the system performance. The test condition have used the diesel fuel, the normal temperature, the diesel fuel supply pressure $3.4kgf/cm^2$ at $-20{\sim}-30^{\circ}C$, the fuel supply quantization 60 l/H, the setting current 30 A and the voltage $13V_{dc}$. In order to simulate the operation of diesel fuel filter, we will establish the composited fuel filter into test jig, and be filled with chamber tank and filter by a constant flow quantization and pressure. After these, it shall be cold for setting time. And then we have measured the consumption current and power of heater, an operating time and pressure of filter.

A Basic Study on Physical Method for Preventing Recombination of Gas Product from the Decomposition of Ammonium Carbamate (암모니움 카바메이트 분해 시 생성된 가스의 재결합 방지를 위한 물리적 방법의 기초연구)

  • Chun, Minwoo;Yoon, Cheon Seog;Kim, Hongsuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.10
    • /
    • pp.639-647
    • /
    • 2017
  • This basic study is focused on the physically removal method of carbon dioxide from the decomposition of ammonium carbarmate to prevent the recombination of ammonium salts. A basic visual experimental set-up was designed and constructed to observe the recombination phenomena from the proper composition of ammonia gas, carbon dioxide gas, and compressed air dilution gas. To quantify the recombination phenomena, a simple device was designed to measure the weight change under severe cases for three different tube sizes. The temperature and pressure in the visual tube and the volumetric flow rates of the nitrogen dilution gas were studied and the conditions to avoid recombination were analyzed according to mean free path theory. Diffusivity values based on the Chapman-Enskog theory were calculated from the experimental data. These value may serve as an index for the prevention of recombination.

Operational Characteristics of Methanol Reformer for the Phosphoric Acid Fuel Cell System (인산형 연료전지용 메탄올 연료개질기의 운전 특성)

  • 정두환;신동열;임희천
    • Journal of Energy Engineering
    • /
    • v.2 no.2
    • /
    • pp.200-207
    • /
    • 1993
  • A methanol reformer was designed and fabricated using a CuO-ZnO low temperature shift catalyst, and its operation characteristics have been studied for the phosphoric acid fuel cell (PAFC) power generation system. The type of reactor was annular Methanol was consumed both for heating and for reforming fuel. Contents of carbon monoxide produced from the reformer increased as the reaction temperatures increased, but decreased as the mole ratios of water to methanol(H$_2$O/CH$_3$OH) increased. At steady state operating conditional, temperature profile of the catalytic reactor of the reformer was well coincide with the model equation, and it took 50 minutes from start to the rated condition of the reformer. When the system was operated at 4/4 and 1/4 of load, thermal efficiencies of the system were 72.3% and 77%, respectively. When the PAFC system was operated with reformed gas in the range of 62 V-37.6 V and 0-147 A, the trend of I-V curve showed a typical fuel tell characteristic. At steady state condition, the flow rates of reforming and combustion methanol were 88.1 mol/h and 50.1 mol/h, respectively.

  • PDF

Experimental Study to Estimate the Required Flow of Fire Extinguishing System for Flame Spread Prevention on Composite Panel (복합패널 화재확산 방지를 위한 소화시스템의 소요유량 산정을 위한 실험적 연구)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Hwi-Seong;Kim, Yang-Kyun
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.33-39
    • /
    • 2017
  • Composite panel refers to the particular plywood produced in a way of stacking the different kinds of material in sandwich form and adhering them using adhesives and is widely used as building material for its constructability and cost efficiency. But as the surface is finished with steel plate, fire extinguishing agent cannot reach to the core material because of such steel plate on surface which causes the difficulties in suppressing the fire as well as in fire-fighting activities due to collapse. This study, to deal with such problem, is intended to set the fire pipe in core material to prevent the fire from spreading and in a bid to achieve this using minimized fire water, water supply test device was fabricated to estimate the required water flow of fire extinguisher and consequently, optimal water flow (0.5 L/min) was determined through a full-scale fire test.

Experimental Investigation of Water Discharge Capability According to Shape of Sluice for Tidal Power Generation - I. Physical Experiment (조력발전용 수문 형상에 따른 통수성능에 관한 실험적 연구 - I. 수리모형실험)

  • Lee, Dal-Soo;Oh, Sang-Ho;Yi, Jin-Hak;Park, Woo-Sun;Cho, Hyu-Sang;Kim, Duk-Gu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.1
    • /
    • pp.73-80
    • /
    • 2008
  • An hydraulic experiment was carried out in an open channel flume in order to improve the technique of designing shape of the sluice used for tidal power generation, which greatly affects the economical efficiency of the construction of a tidal power plant. To predict the influence of change in the major design parameters relating to the sluice shape on the water discharge capability of the sluice, it was necessary to perform a precise experiment that is discriminated to previous feasibility studies or design projects. For this purpose, by installing various flow straighteners and rectifying structures inside the water supply system and the rectifying tank, the flow in the flume was stabilized as tranquil as possible. In addition, the measuring instruments and the location of installing them were carefully determined so as to minimize the errors intervened during the measurement of water discharge and water level. The method of estimating head difference between upstream and downstream of the sluice was also developed by taking account of the head loss due to the friction at the bottom and side walls in the flume.

Microstructural Realization of SD400 Rebar by Developing Tempcore Simulation Apparatus (템프코어 냉각모사 장치 개발을 통한 SD400 철근 미세조직 구현)

  • Park, Chun Su;Yi, Hyang Jun;Bae, Seh Wook;Kim, Gil-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.5
    • /
    • pp.543-547
    • /
    • 2015
  • The cooling process referred to as Tempcore has been applied to produce a high-strength rebar. Excellent rebar with strength and weldability can be manufactured from mild steel without the addition of alloying elements by using the Tempcore process. However, there are limitations to evaluating the effect of various chemical compositions and cooling conditions within a site facility. In this study, we developed an apparatus to simulate the Tempcore process and obtained microstructures with a hardened surface layer, an intermediate region and a soft inner core. The experimental apparatus has been equipped with a cooler set that is the same as the site facility and consists of a pump line that supplies pressure of 12-13 bar and flow rate of up to $50m^3/h$. In accordance with the simulation result of steel grade SD400 that requires more than 400 MPa of yield strength, both the hardened area ratio and the hardness with respect to each cooling depth were found to agree well with the product.

Differences of Blood Oxygen Saturation between 20s and 60s due to Amount of Highly Concentrated Oxygen Administration (고농도 산소 공급량에 따른 20대와 60대의 혈중 산소 포화도의 차이)

  • Choi, Mi-Hyun;Kim, Ji-Hye;Lee, Su-Jeong;Yang, Jae-Woong;Yi, Jeong-Han;Jun, Jae-Hoon;Kim, Hyun-Jun;Lee, Tae-Soo;Chung, Soon-Cheol
    • Science of Emotion and Sensibility
    • /
    • v.13 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • The purpose of this study was to examine differences between 20s and 60s in blood oxygen saturation due to 93% oxygen administration of the three levels(1L/min, 3L/min, 5L/min). Ten 20s male($25.0{\pm}1.8$ years), ten 20s female($23.7{\pm}1.9$ years), ten 60s male($68.0{\pm}2.6$ years), and ten 60s female($65.5{\pm}3.1$ years) were selected as the subjects for this study. The oxygen supply equipment(OXUS Co.) provided oxygen by supply rate(i.e., 1L/min, 3L/min, and 5L/min) at a constant rate of 93% oxygen. The experiment consisted of three phases, i.e., Prehyperoxia(5min), Hyperoxia(10min), and Post-hyperoxia(5min). Blood oxygen saturation were measured throughoutthe three phases. By increasing the amount of highly concentrated oxygen administration, blood oxygen saturation was increased. Blood oxygen saturation of 20s was higher than 60s. Blood oxygen saturation was greater during Hyperoxia than during Pre- and Post-hyperoxia. However, rising rate of blood oxygen saturation of 60s by oxygen administration was higher than 20s.

  • PDF

Thermal Performance of PV Cells Exposed to Irradiation by a Parabolic Trough Concentrator (PTC형 태양열 집열기로 조사되는 PV cell의 열적 성능)

  • Hwang, Seon Yeob;Kang, Tae Gon;Boo, Joon Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.68-68
    • /
    • 2011
  • 본 연구에서는 PV cell이 직달 일사에 노출되는 경우와 집광된 태양광에 조사되는 경우의 성능을 비교하는 한편 집광기의 형태에 따른 열적 성능을 검토하고자 하였다. PV cell은 본질적으로 반도체의 특성을 가지므로 작동온도의 상승에 따라 성능이 저하된다는 사실이 알려져 있으며, 태양조사의 강도 및 밀도 등 특성에 따라서도 성능의 변화를 예상할 수 있다. 그러나 이러한 성능변화에 관련된 인자들과 그 영향의 크기에 대한 정량적인 기술자료가 부족하므로 설치와 이용에 한계가 있는 것이 현실이다. 인공태양 장치(solar simulator)를 이용하여 0.7에서 1.2 sun 범위의 태양 조사 환경에서 결정질 실리콘계 PV cell과 집광형 PV cell의 성능을 검토하였다. 집광에 사용한 PTC는 집광면적의 폭이 500 mm이며, 집광 조사면적이 최소 10 mm인 경우 이론적 최대 집광비가 50이었다. PTC의 축방향으로는 균일한 태양조사가 있게된다는 것을 가정하여 모델의 길이는 간편한 실험을 위해 150에서 500 mm의 범위에서 제작하였다. 수평으로 놓인 PTC의 상부 초점 위치로부터 집광면이 아래 쪽에 위치할수록 집광 조사 면적이 증가하므로 PV cell의 크기에 따라 PTC 초점의 위치로부터 거리를 결정하였다. 한편, PTC 자체의 성능도 촛점거리와 집광면 폭의 비에 따라 달라질 수 있다는 가정 하에, 포물면의 최저 위치로부터 촛점거리는 각각 300, 400 및 500 mm가 되도록 세가지 형태를 제작하여 사용하였다. 동일한 형태의 PTC에서 PV cell의 동일한 설치 위치에서도 최고 $110^{\circ}C$ 범위의 PV cell의 작동 (표면) 온도에 따른 성능의 차이를 관찰하기 위해 셀의 후면을 냉각시키는 경우와 그렇지 않은 경우를 비교하였다. PV cell의 표면 온도 측정을 위해서, 후면의 온도와 같이 광선 차단 효과의 우려가 없는 경우에는 열전대를 설치하였으며, 셀의 전면 온도 측정을 위해서는 비접촉식 적외선 온도계를 사용하였다. 냉각 방법으로는 공기를 이용한 자연대류와 액체를 사용하는 강제대류의 경우를 고려하였으며, 필요에 따라 적절히 설계된 히트싱크를 설치하여 비교 실험을 진행하였다. 강제대류 냉각의 경우는 항온조를 사용하여 순환하는 냉각수의 유량과 공급온도를 변화시킴으로써 PV cell의 작동온도를 조절하고, 이에 따른 발전 성능의 변화를 관찰하였다. 본 연구에서 도출한 실험 및 분석 결과는 PV cell의 설치 환경과 작동온도의 변화에 따라 그 성능 변화를 예측할 수 있는 기술적 자료를 제공함으로써 에너지 이용의 합리화를 도모하는데 기여할 수 있을 것이다.

  • PDF

USN-based Water Treatment Plant Facilities Data Management Techniques and Reliability (USN 기반 수직형 정수처리시설 데이터 최적관리 및 신뢰성 검증연구)

  • Jang, Sang-Bok;Shin, Gang-Wook;Hong, Sung-Taek;Lee, An-Kyu;Park, Hye-Mi;Chun, Myung-Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.11
    • /
    • pp.2736-2744
    • /
    • 2013
  • In this paper, we present a Smart Water Treatment Plant using Zigbee USN devices and a real-time monitoring system in K-water Flow Meter Calibration Center Building. For verification, the data of vertical type WTP such as flow rate, pressure, water level and water temperature are obtained by the Zigbee USN devices, operating in 2.45 GHz band, and be wirelessly surveilled by the real-time monitoring system. The received data from the sensor is transmitted to the data processing device, and then the processed data can be monitored on a smart phone. Consequently, the pilot plant based on the low-cost and high-efficiency USN has been developed with the performance analysis for the communication network and remote monitoring system on mobile devices.