• 제목/요약/키워드: 유동 기인 진동

검색결과 172건 처리시간 0.024초

FIV 시험루프의 유동기인 진동 신호분석 (Flow-Induced Vibration Signal Analysis of the FIV Test Loop)

  • 이강희;강흥석;윤경호;송기남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.601-606
    • /
    • 2004
  • Vibration spectrums of the test loop according to flow conditions were analyzed in order to identify the sources of vibration at peak frequencies. While a flow condition of the sweep test was changed by varying pump rotational speed from 450 rpm to 1500 rpm by the step 150 rpm, midspan acceleration of the test section in width-direction and dynamic pressure perturbation in the test section were measured. Other sources of vibration due to the flow structure interactions, such as acoustic resonance, blade pulsing frequency and bellows wrinkles, were investigated. Pressure perturbation in the section and acoustic resonance due to branch pipe give major effects to the vibration of the test section in high frequency range of 1.5 kHz to 2.8 kHz.

  • PDF

횡류팬을 적용한 진공청소기 흡입노즐내 유동 소음 저감에 관한 연구 (Reduction of Flow-Induced Noise in Suction Nozzle of a Vacuum Cleaner by Adopting a Cross-Flow Fan)

  • 박이선;손채훈;이성철;오장근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.935-938
    • /
    • 2007
  • In suction nozzle of a vacuum cleaner, where flow-induced noise is generated mainly by flow resistance, several ideas to reduce noise are investigated. To increase fan performance, blade number is optimized and a centrifugal fan is replaced by a cross-flow fan, In addition, gear ratio of fan to drum brush is changed. It is found that fan performance is increased by adopting these methods. Next, the blade height of the fan is decreased to reduce sound pressure level, which causes inevitably decrease in fan performance. Eventually, flow-induced noise is reduced by 6.3 dBA in its overall level with the fan performance maintained.

  • PDF

자기점성유체 댐퍼의 자기장 및 유동 해석에 따른 성능비교 (Comparison of Performances refer to Magnetic and Fluid Analysis of Magneto-Rheological Flow Damper)

  • 송준한;손성완;이규섭;전종균
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.98-102
    • /
    • 2009
  • The magneto-rheological fluid expresses different cohesiveness according to the strength of the external electric current. To manufacture the magneto-rheological fluid damper that uses such characteristics of the fluid, a flow analysis of the inner damper was conducted to forecast the damper's capacity. In addition, using the finite element method software, analysis on the characteristics of electromagnetic field around the coil operation unit inside the damper. Based on the result of the analysis, a single core damper and a double core damper were built and tested for their dynamic function. Based on the result of the experiment, the propriety of the flow analysis was demonstrated, and the proposed model was verified.

  • PDF

왕복압축기용 머플러의 유동-음향 성능 특성에 대한 수치적 고찰 (Numerical investigation into the characteristics of flow and acoustic performances of mufflers for a reciprocating compressor)

  • 김상현;정철웅;김해승;이효재
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.673-678
    • /
    • 2014
  • In a compressor, highly impulsive pressure fluctuations induced by a reciprocating piston and valves cause noise and vibration to be so critical issues that low noise requirement always challenges engineers developing it. A muffler is frequently used for reducing these impulsive noise components, but has adverse effects on compressor's performance due to additional pressure drop and heat transfer of refrigerant when it pass through the muffler. In this study, compressible full 3-dimensional CFD simulations are performed to investigate both of flow and acoustic performances of a muffler in use for compressors. On a basis of the analysis results, a parametric study using design factors introduced to improve flow and acoustic performances of the existing muffler is carried out. Finally, improved designs are suggested to confirm the current results.

  • PDF

다공판 시스템의 흡음성능에 관통유동이 미치는 효과 (Effect of the through-flow on the absorption performance of a perforated plate system)

  • 허성욱;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.163-167
    • /
    • 2003
  • This paper is to experimentally investigate the effect of the through-flow on the absorption performance of a perforated plate system. The experiment is performed through the systematic change of the through-flow velocity, incident sound pressure level, and the geometrical parameters such as the porosity and hole diameter. From the experimental results, it is found that fur the nonlinear relationship between the acoustic resistance and incident sound pressure level there is no influence of the through-flow on the absorption performance, but for the linear relationship between them there is a strong dependence of the absorption performance on the through-flow velocity. It is also shown that the absorption performance is controllable by changing the porosity and hole-diameter in size.

  • PDF

말토 덱스트린 첨가 알루미나 슬러리의 유동특성에 미치는 초음파 처리 강도와 진동 시간의 영향 검토 (Effects of ultrasonication intensity and shaking time on the rheological behavior of alumina slurries with maltodextrin)

  • 김종철;오근호
    • 한국결정성장학회지
    • /
    • 제10권1호
    • /
    • pp.80-85
    • /
    • 2000
  • 말토 덱스트린이 첨가된 알루미나 슬러리의 공정조건 변화에 따른 유동특성 변화를 실험계획법과 통계적 방법을 사용하여 분석하였다. 공정조건으로는 말토 덱스트린 첨가 여부, 말토 덱스트린 첨가 전.후에 슬러리에 대한 초음파 처리, 슬러리의 진동기 유지시간 등이 검토되었다. 대부분의 경우 슬러리의 점도는 전단 희석 특성을 나타내었으며 Ostwald-de-Weale 모델에 적합한 것으로 나타났다. 알루미나 슬러리의 점도는 말토 덱스트린이 첨가됨에 따라 감소하였으나 초음파 처리 강도가 증대됨에 따라 증가되었으며, 초음파 처리 전.후에 말토 덱스트린을 첨가하는 것은 슬러리의 점도에 별다른 영향을 미치지는 않았다.

  • PDF

APR1400 종합진동평가를 위한 배관시스템의 유동유발진동 간이평가 (Screening Method for Flow-induced Vibration of Piping Systems for APR1400 Comprehensive Vibration Assessment Program)

  • 고도영;김동학
    • 한국소음진동공학회논문집
    • /
    • 제25권9호
    • /
    • pp.599-605
    • /
    • 2015
  • U.S. Nuclear Regulatory Commission(NRC), Regulatory Guide(RG) 1.20(Rev.3, 2007년)은 원자로 냉각재계통, 주증기, 주급수 및 복수시스템의 주요 배관 및 기기에 대하여 압력변동 및 진동에 의한 잠재적 유해효과에 대한 평가를 요구한다. 그러나 증기발생기와 연결된 주증기, 주급수 및 복수시스템의 주요 배관 전체에 대하여 상세 해석하는 것은 매우 복잡하여 한계가 있다. 이 논문은 APR1400 원전의 종합진동평가(comprehensive vibration assessment program, CVAP)를 수행하기 위하여 증기발생기에 연결된 2차측 주요 배관의 음향공진과 펌프유발진동을 위한 간이평가 방법에 관한 것이다. 이 논문에서는 이러한 배관시스템의 잠재적 진동 원인이 무엇인지, 음향공진과 펌프유발진동의 가능성을 예방하기 위한 간이평가 방법은 무엇인지를 고찰하고자 한다. 이 논문은 APR1400 원전 증기발생기와 연결된 주증기 및 주급수 배관의 유동유발진동 간이평가를 위해 사용될 것으로 판단된다.

Lock-in 영역에서 원형실린더의 와류유기진동 전산해석 (Numerical Analysis of Vortex Induced Vibration of Circular Cylinder in Lock-in Regime)

  • 이승수;황규관;손현아;정동호
    • 한국전산구조공학회논문집
    • /
    • 제29권1호
    • /
    • pp.9-18
    • /
    • 2016
  • 고층빌딩이나 해양 라이저와 같은 세장 구조물은 구조시스템의 동적 불안정의 주요 원인인 와류유기진동(vortex-induced vibration, VIV)에 의한 동하중에 매우 취약하다. 와류유기진동이 라이저의 고유진동수 영역에서 발생하는 경우 Lock-in현상으로 피로파괴의 우려가 있다. 본 논문에서는 Lock-in 영역에서 구조물과 유동의 동적거동에 대한 수치해석을 다루었으며, 유동조건 변화에도 불구하고 공진 주파수가 유지되는 현상에 대해 분석하였으며, 유입유동에 대해 수직방향으로 자유진동하는 1자유도의 2차원 원형실린더 단면에 대한 비정상 층류를 가정하였다. 각 시간 단계에서 물체의 움직임을 고려하여 유동장 격자를 재생성하며 비정상 유동과 물체의 운동에 대한 지배방정식을 순차적으로 수치해석하여 유체-구조 연성해석을 수행하였다. 결과는 선행연구와 잘 일치함을 보여주었고, Lock-in 현상에 대한 특성을 잘 나타내었다. Lock-in 영역에서는 양력뿐만 아니라 항력도 크게 증가함을 보여주었으며, 실린더의 수직변위는 직경의 20%까지 이름을 나타내었다. 양력과 수직변위의 상관분석을 통해 실린더가 Lock-in 영역에서 양력과 수직변위의 위상차가 동기로부터 반동기로 천이함을 확인하였으며, 이러한 변화가 Lock-in 영역에서 나타나는 공진거동의 원인이 되는 것으로 판된되었다.