• Title/Summary/Keyword: 유동해석

Search Result 6,471, Processing Time 0.028 seconds

An Examination on the Dispersion Characteristics of Boil-off Gas in Vent Mast Exit of Membrane Type LNG Carriers (멤브레인형 LNG선박 화물탱크 벤트 마스트 출구에서의 BOG 확산 특성에 관한 연구)

  • Kang, Ho-Keun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.2
    • /
    • pp.225-231
    • /
    • 2013
  • Liquefied gas carriers generally transport cargoes of flammable or toxic nature. Since these cargoes may cause an explosion, fire or human casualty, the accommodation spaces, service spaces and control stations of liquefied gas carriers should be so located as to avoid ingress of gas. For this reason, the paragraph 8.2.9 of IGC Code in IMO requires that the height of vent exits should be not less than B/3 or 6 m whichever is greater, above the weather deck and 6 m above the working area and the fore and aft gangway to prevent any concentration of cargo vapor or gas at such spaces. Besides as known, the LNG market has been growing continually, which has led to LNG carriers becoming larger in size. Under this trend, the height of a vent will have to be raised considerably since the height of a vent pipe is generally decided by a breadth of a corresponding vessel. Accordingly, we have initiated an examination to find an alternative method which can be used to determine the safe height of vent masts, instead of the current rule requirement. This paper describes the dispersion characteristics of boil-off gas spouted from a vent mast under cargo tank cool-down conditions in the membrane type LNG carriers.

Method for Improvement of Reduction Reactivity at High Temperature in a Chemical-Looping Combustor (매체순환식 가스연소기에서 고온 환원반응성 증대 방법)

  • Ryu, Ho-Jung;Park, Sang-Soo;Lee, Dong-Ho;Choi, Won-Kil;Rhee, Young-Woo
    • Korean Chemical Engineering Research
    • /
    • v.50 no.5
    • /
    • pp.843-849
    • /
    • 2012
  • When we use NiO based particle as an oxygen carrier in a chemical looping combustion system, the fuel conversion and the $CO_2$ selectivity decreased with increasing reaction temperature within high temperature range (> $900^{\circ}C$) due to the increment of exhaust CO concentration from reduction reactor. To improve reduction reactivity at high temperature, the applicable metal oxide component was selected by calculation of the equilibrium CO concentration of metal oxide components. After that, feasibility of reduction reactivity improvement at high temperature was checked by using solid mixture of the selected metal oxide particle and NiO based oxygen carrier. The reactivity was measured and investigated using batch type fluidized bed. The solid mixture of $Co_3O_4/CoAl_2O_4$(10%) and OCN706-1100(90%) showed higher fuel conversion, higher $CO_2$ selectivity and lower CO concentration than OCN706-1100(100%) cases. Consequently, we could conclude that improvement of reduction reactivity at high temperature range by adding some $Co_3O_4$ based oxygen carrier was feasible.

Development of Algorithms for the Construction of Hydrogeologic Thematic Maps using AvenueTM Language in ArcView GIS (ArcView GIS의 AvenueTM Language를 활용한 수문지질도 작성 알고리즘 개발 및 적용 사례 연구)

  • Kim, Gyoo-Bum;Son, Young-Chul;Kim, Jong-Wook;Lee, Jang-Yong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.8 no.3
    • /
    • pp.107-120
    • /
    • 2005
  • In Korea, MOCT and KOWACO published a standard for lineament map drawings, "The Handbook for the Drawing and Management of Hydrogeologic Map" in 2003. According to this guideline, hydrogeologic and related thematic maps should include characteristics of groundwater quality and quantity. These maps are generally drawn with ArcView GIS 3.x software. The activities of well notation on groundwater level map and Stiff diagram drawings on groundwater quality map require a great deal of efforts because hundreds or thousands of well data, water level data and hydrogeochemical data are produced through many kinds of investigations. As well, lineament density map is very important to survey and explore groundwater in a deep aquifer. In this study we developed some modules for well notation, Stiff diagram drawings, and lineament density value calculation with Avenue$^{TM}$ script and it was revealed that they can be very useful and easy for drawing groundwater thematic maps.

  • PDF

Analytical and Experimental Study on a Thermal Liquid Mass Flow Meter (가열식 액체용 질량유량계측기에 관한 이론 및 실험적 연구)

  • Kim, Taig Young;Kang, Chang Hoon;Shin, Yoon Sub;Kim, Tae Su;Choi, Seon Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.4
    • /
    • pp.309-316
    • /
    • 2015
  • Numerical analysis and experimental verification of a thermal liquid mass flow meter (LMFM) were performed. The configuration of the LMFM was the same as a gas mass flow meter (GMFM), but the opposite results in temperature difference between upstream and downstream thermistors occurred. In the case of the gas, the convection depending on the flow of thermal mass was small and comparable to the conduction through the sensor tube wall. The temperature difference was proportional to the mass flow rate due to their interaction. For the liquid flow, the convection overwhelmed the wall conduction because of the large flow of thermal mass caused by high density. The temperature difference in this case was inversely proportional to the mass flow rate. The tube diameter and heater wiring width are important design parameters, and the optimized sensor can be used to measure and control the infinitesimal liquid flow rate.

Design and Verification of Ceramic Heating Element-based Tankless Instant Electric Water Heater (세라믹 발열체기반 비저장식 순간 전기 온수기 개발 및 검증)

  • Ahn, Sung-Su;Kim, Woo-Hyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.151-159
    • /
    • 2016
  • This paper proposes a ceramic heating element-based tankless instant electric water heater for hand/face washing that does not require a lot of hot water. The heating module, which heats the input water and outputs hot water, operates the ceramic heating element detecting input water using a flow sensor. Inside of the heating module is designed to form one flow path in order to get almost $15^{\circ}C$ increased heated water compared to the input water temperature within 2 second after 1.5 liter per minute water supply. The design validity is verified using a heat flow analysis of the water flow and temperature variations inside of the heating module also. Based on the design data, the heating module is constructed including a single rod-type ceramic heating element. After that, a prototype system having temperature setting function by three steps were constructed. The prototype system is connected to a 1.5 liter per minute water supply line, and the water output temperature and time measurement experiments confirmed that the proposed system output the heated water increased by $18.3^{\circ}C$ in case of third step setting within 2 second after water supply. And standby power is under 1 W and peak power does not exceed the permissible range for the general house usage. Several performance results verify that the proposed tankless instant electric water heater is applicable for the washstand of the house, highway rest area and factory so on as winter-time hand/face washing.

The Effect of Skewness of Nonlinear Waves on the Transmission Rate through a Porous Wave Breaker (파형의 왜도가 투과성 방파제 투과율에 미치는 영향)

  • Cho, Yong Jun;Kang, Yoon Koo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.29 no.6
    • /
    • pp.369-381
    • /
    • 2017
  • It has been presumed that highly nonlinear skewed waves frequently observed in a surf zone could significantly influence the transmission behaviour via a porous wave breaker due to its larger inertia force than its nonlinear counterparts of zero skewness [Cnoidal waves]. In this study, in order to confirm this perception, a numerical simulation has been implemented for 6 waves the skewness of that range from 1.02 to 1.032. A numerical simulation are based on the Tool Box called as the ihFoam that has its roots on the OpenFoam. Skewed waves are guided by the shoal of 1:30 slope, and the flow in the porous media are analyzed by adding the additional damping term into the RANS (Reynolds Averaged Navier-Stokes equation). Numerical results show that the highly nonlinear skewed waves are of higher transmitted ratio than its counterparts due to its stronger inertia force. In this study, in order to see whether or not the damping at the porous structure has an effect on the wave celerity, we also derived the dispersive relationships of Nonlinear Shallow Water Eq. [NSW] with damping at the porous structure being accounted. The newly derived dispersive relationships shows that the phase lag between the damping friction and the free surface elevation due to waves significantly influence the wave celerity.

Numerical Analysis of Deformation Behaviour of Underground Opening in a Discontinuous Rock Mass Using a Continuum Joint Model (연속체 절리모델을 이용한 불연속성암반 내 지하공동의 변형거동에 관한 수치해석)

  • Kang Sang Soo;Lee Jong-Kil;Baek Hwanjo
    • The Journal of Engineering Geology
    • /
    • v.15 no.3
    • /
    • pp.257-268
    • /
    • 2005
  • In situ rock mass is generally heterogeneous and discontinuous, with varying degrees of strength along the planes of weakness. The planes of weakness such as joints, faults, cracks and bedding planes, control the strength and deformation characteristics of the rock mass. Subsequently, the stability of underground opening depends upon the spatial distribution of discontinuities and their mechanical properties in relation with geometrical shape of openins as well as the mechanical properties of intact rock materials. Understanding the behaviour of a discontinuous rock mass remains a key issue for improving excavation design in hiかy stressed environments. Although recent advances in rock mechanics have provided guidelines for the design of underground opening in isotropic rock mass, prediction and control of deformation in discontinuous rock masses are still unclear. In this study, parametric study was performed to investigate the plastic zone size, stress distribution and deformation behavior around underground opening in a discontinuous rock mass using a continuum joint model. The solutions were obtained by an elasto-plastic finite difference analysis, employing the Mohr-Coulomb failure criteria. Non-associated flow rule and perfectly plastic material behavior are also assumed.

Interpretation of Groundwater System and Contamination by Water-Quality Monitoring in the Daejung Watershed, Jeju Island (지하수 수질 관측에 의한 제주도 대정수역의 지하수계 및 오염특성 분석)

  • 우남칠;김형돈;이광식;박원배;고기원;문영석
    • Economic and Environmental Geology
    • /
    • v.34 no.5
    • /
    • pp.485-498
    • /
    • 2001
  • This study was objected to identify the temporal and spatial variations oi groundwater quality and contamination using monthly groundwater monitoring data collected from 30 wells in Daejung watershed, Jeju Island. Water samples were analyzed for major cations. anions, and environmental isotopes including $^{18}0-H_2$O,$^{2}H-H_2$O and$^{15}$ N-NO$_3$The groundwater represented mostly Na(Mg)-HCO$_3$ type, with local change toward Ca-HCO$_3$ type and Na-Cl type. Groundwater quality depends upon various factors such as the local groundwater flowpaths, input of surface contaminants with recharge events, and sea-water intrusion along the coastal area. Nitrate contamination changed temporally according to recharge events and spatially. $\delta$$^{18}$ O-$\delta$$_2$H data for monthly sampled groundwaters showed distinctive clusters, implying that groundwater was originated from independent precipitation, and subsequently recharged very fash. Using$\delta$$^{15}$ N-NO$_3$ data, major sources of nitrate and its areas of influence could be identified. The areas under influence of livestock farms showed relatively high NO$_3$-N concentrations and$\delta$$^{15}$ N values higher than 5$\textperthousand$. The agricultural areas in southeastern part showed very high concentrations of NO$_3$-N with the $\delta$$^{15}$ N values of lower than 5$\textperthousand$.

  • PDF

Preparation and Characterization of Bentonite Rheology Modifiers (벤토나이트 유동성 개질제의 제조 및 특성)

  • Lee, Suk-Kee;Koo, Kwang-Mo;Yang, Kyung-Su;Park, Sung-Woo;Lee, Byung-Kyo
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.11
    • /
    • pp.1090-1096
    • /
    • 2002
  • Six different composition of water-swellable bentonite rheology modifiers(WSB-1~WSB-6) were prepared by the compounding of peptizers and anionic surfactants as an additives with Bentonite(BEN) of montmorillonite group. Average particle size, particle morphology and water-swellability of WSB and the viscosity with additives were measured, respectively. And the rheological behavior of WSB were investigated using the rheometer. The viscosity of WSB-1 increased with decreasing both pH and average particle size of BEN, WSB-2 treated $Na_2CO_3$ as a peptizer showed the maximum viscosity. These results can be interpretated cause for rearrangment as the edge-to-face structure of BEN particles containing WSB. Also, WSB-4∼WSB-6 containing both peptizer and anionic surfactant was sol phase that their viscosity was not nearly with the shear rate, however, WSB-3 containing Tetrasodium Pyrophosphate(TSPP) as an anionic surfactant showed the thixotropy by the viscosity difference of 1000 times with the shear rate. From this result, the anions of TSPP can be explained to arrange in edge of BEN particles containing WSB-3.

Channel Structure and Header Design of Printed Circuit Heat Exchanger by Applying Internal Fluid Pressure (유체 내압을 고려한 인쇄기판형 열교환기의 채널구조 및 헤더 설계)

  • Kim, Jungchul;Shin, Jeong Heon;Kim, Dong Ho;Choi, Jun Seok;Yoon, Seok Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.11
    • /
    • pp.767-773
    • /
    • 2017
  • Printed Circuit Heat Exchanger (PCHE) has an advantage for exchanging thermal energy between high-pressure and high-temperature fluids because its core is made by diffusion bonding method of accumulated metal thin-plates which are engraved of flow channel. Moreover, because it is possible that the flow channel can be micro-size hydraulic diameter, the heat transfer area per unit volume can be made larger than traditional heat exchanger. Therefore, PCHE can have higher efficiency of heat transfer. The smaller channel size can make the larger heat transfer area per unit volume. But if high pressure fluid flows inside the channel, the channel wall can be deformed, the structure and shape of flow channel and header have to be designed appropriately. In this study, the design methodology of PCHE channel in high pressure environment based on pressure vessel codes was investigated. And this methodology was validated by computational analysis.