• Title/Summary/Keyword: 유도 전위

Search Result 292, Processing Time 0.028 seconds

A Study on the Response Propogation of Biological Action Potential (생체의 활동전위 전도에 관한 연구)

  • Che, Gyu-Shik;Moon, Myung-Ho;Chang, Won-Seok
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.4
    • /
    • pp.562-570
    • /
    • 2010
  • The transmission phenomenon of neuron action potential due to exterior stimulation is somewhat identical to electrical reaction configuration. Therefore, I tried to analyze the transmission status of membrane excitation, by introducing electrical concept to this issue in this paper. First of all, I researched the complex electrical status of axon, and then simplified the electrical circuit into pure resistance circuit under the assumption that it was reasonable in practice. And I derived the transmission status of exciting action potential through the simplified circuits using electical theory and mathematical concept. I calculated overshoot potential of a certain portion and then confirmed that it excited neighbor portion and made it to be transmitted using the proposed data which was typical in point of biological and electrical view to verify this result.

Electrohydrodynamic Treatment of the Shape and Stability of Liquid Metal Ion Sources (액체금속 이온 소오스의 모양과 안정도에 대한 전자유체역학적 연구)

Characteristic Analysis of Cyclic Voltammetry on a Self-Assembled Mono-layer Electrode (자가조립 단층 전극에 대한 순환전위법의 특성해석)

  • Cho, Hana;Yoon, Do-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.16 no.4
    • /
    • pp.217-224
    • /
    • 2013
  • In this paper, we have investigated the characteristics of cyclic voltammetry of a self-assembled mono-layer(SAM) electrode which was modified by 3-Mercaptopropionic acid (3-MPA) on gold nanoparticle(AuNP)-deposited electrode. Also, the transport phenomena of electrons and ions around the electrode have been analyzed. The governing equation and its boundary conditions by adopting the semi-infinite diffusion model were formulated for the mass-transfer dominant system. In order to obtain the numerical solutions of cyclic voltammetry(CV) on SAM electrodes, MATLAB program was implemented by applying the explicit finite difference method. Resulting CV program for the SAM-modified electrode was verified in good agreements with the experimental CV results for the 3-MPA on AuNP electrode.

The computation of the torso surface potentials using the boundary element method (경계요소법을 이용한 트로소 표면전위의 계산)

  • 이경중;이세진
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.8
    • /
    • pp.22-29
    • /
    • 1996
  • This study describes a method to find the torso surface potential based on the boundary element method. In order to find the torso surface potential, the governing equation was developed based on the green's second theorem. The boundary element method (BEM) which has a good computing capability in case of homogeneous and isotropic medium was applied to solve the equation. to validate the BEM, we considered a homogeneous sphere model which has an electrric dopole source inside. The results showed the good agreement between the analytic solution and the computed solution. In normal heart, the simulated torso surface isopotential maps are good agreement with that obtained form the ventricular excitation.

  • PDF

The Significance of Electroencephalography in the Hypothermic Circulatory Arrest in Human (인체에서 저체온 완전 순환 정지 시 뇌파검사의 의의)

  • 전양빈;이창하;나찬영;강정호
    • Journal of Chest Surgery
    • /
    • v.34 no.6
    • /
    • pp.465-471
    • /
    • 2001
  • Background: Hypothermia protects the brain by suppressing the cerebral metabolism and it is performed well enough before the total circulatory arrest(TCA) in the operation of aortic disease. Generally, TCA has been performed depending on the rectal or nasopharyngeal temperatures; however, there is no definite range of optimal temperature for TCA or an objective indicator determining the temperature for safe TCA. In this study, we tried to determine the optimal range of temperature for safe hypothermic circulatory arrest by using the intraoperative electroencephalogram(EEG), and studied the role of EEG as an indicator of optimal hypothermia. Material and Method: Between March, 1999 and August 31, 2000, 27 patients underwent graft replacement of the part of thoracic aorta using hypothermia and TCA with intraoperative EEG. The rectal and nasopharyngeal temperatures were monitored continuously from the time of anesthetic induction and the EEG was recorded with a ten-channel portable electroencephalography from the time of anesthetic induction to electrocerebral silence(ECS). Result: On ECS, the rectal and nasopharyngeal temperatures were not consistent but variable(rectal 11$^{\circ}C$ -$25^{\circ}C$, nasopharynx 7.7$^{\circ}C$ -23$^{\circ}C$). The correlation between two temperatures was not significant(p=0.171). The cooling time from the start of cardiopulmonary bypass to ECS was also variable(25-127min), but correlated with the body surface area(p=0.027). Conclusion: We have found that ECS appeared at various body temperatures, and thus, the use of rectal or nasopharyngeal temperature were not useful in identifying ECS. Conclusively, we can not fully assure cerebral protection during hypothermic circulatory arrest in regards to the body temperatures, and therefore, the intraoperative EEG is one of the necessary methods for determining the range of optimal hypothermia for safe circulatory arrest. :

  • PDF

Electrokinetically Flow-Induced Streaming Potential Across the Charged Membrane Micropores: for the Case of Nonlinear Poisson-Boltzmann Electric Field (하전된 멤브레인 미세기공에서의 계면동전기적 유동에 의한 흐름전위: 비선형 Poisson-Boltzmann 전기장을 갖는 경우)

  • Myung-Suk Chun
    • Membrane Journal
    • /
    • v.13 no.1
    • /
    • pp.37-46
    • /
    • 2003
  • The electrokinetic effect can be found in cases of the fluid flowing across the charged membrane micropores. The externally applied body force originated from the electrostatic interaction between the nonlinear Poisson-Boltzmann field and the flow-induced electrical field is taken into the equation of motion. The electrostatic potential profile is computed a priori by applying the finite difference scheme, and an analytical solution to the Navier-Stokes equation of motion for slit-like pore is obtained via the Green's function. An explicit analytical expression for the flow-induced streaming potential is derived as functions of relevant physicochemical parameters. The influences of the electric double layer, the surface potential of the wall, and the charge condition of the pore wall upon the velocity profile as well as the streaming potential are examined. With increasing of either the electric double layer thickness or the surface potential, the average fluid velocity is entirely reduced, while the streaming potential increases.

450 mm Wafer 가공을 위한 자화유도결합플라즈마 시뮬레이션 연구

  • Lee, Ho-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.411-411
    • /
    • 2010
  • Cavity mode Whistler wave를 사용하는 자화유도결합플라즈마 (Magnetized Inductively Coupled Plasma, MICP)의 제반 특성을 비등방성 수송계수를 가지는 Drift-Diffusion 근사, 에너지 보존 방정식 및 유도전자계를 self-consistent 하게 고려하여 계산하였다. 이러한 접근법은 비충돌성 전자가열현상을 고려하지 못하는 단점에도 불구하고, 반도체 장비설계에 필수적인 전자온도, 밀도, 플라즈마 전위, 시스템의 임피던스 특성에 대한 경향성 파악에 매우 유용하다. 뿐만 아니라 전자밀도분포가 공간내에 형성되는 R-wave mode에 미치는 영향을 분석할 수 있다. 직경 320 mm를 가지는 작은 반응기에서 시뮬레이션과 실험결과를 비교하여 본 모델링 방법의 타당성을 검증한 후, 450 mm wafer가공에 적합한 대면적 플라즈마 반응기에서 플라즈마 특성을 연구하였다. 수 mTorr의 공정압력에서 약 10 Gauss전후의 약한 자장이 인가됨으로서 반경방향의 전자밀도 균일성이 대폭 향상되었다. 플라즈마 및 안테나의 대면적화에 수반되는 높은 Q값이 자장의 인가로 큰 폭으로 감소함으로서 임피던스메칭의 안정성이 비약적으로 개선되었고 전력전달 효율 또한 크게 증가함을 알 수 있었다. 본 연구 결과는 차세대 450 mm 반도체 공정장비의 개발에 있어 자화유도결합플라즈마가 매우 유용하게 사용될 수 있음을 보여준다.

  • PDF

Affordance Feature based on EEG for the Implementation of Mirror Neuron System (거울신경체계 구현을 위한 EEG 데이터 기반 행동 유도성 특징 분석)

  • Jun-Ho Choi;Seungmin Park
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2023.07a
    • /
    • pp.357-358
    • /
    • 2023
  • 본 연구는 실제 행동과 운동 심상으로 팔과 다리 동작 인식을 위한 BCI 패러다임을 제안하고 유도성 분석을 한다. 이 페러다임은 각 팔과 양다리의 특정 움직임을 인식하기 위해 ERP를 기반 페러다임을 구성한다. BCI 페러다임은 왼팔, 오른팔, 양다리를 움직이는 영상 자극을 주며 이를 기반으로 왼팔, 오른팔, 양다리 움직임에 대한 인식을 한다. 거울뉴런은 실제 행동과 실제 행동을 보았을때와 운동심상을 통한 자극을 받았을 때 같은 뉴런이 활성화된다는 성질을 가지고 있다. 이러한 성질을 이용하여 운동심상만과 실제 행동을 동시에 학습할 경우를 유도성 분석을 진행한다. 또한 유도성 특징 분석을 통해 나타난 결과를 바탕으로 BCI 패러다임을 제안한다.

  • PDF

23KV Y배전방식 연구 1

  • 민정근
    • 전기의세계
    • /
    • v.15 no.3
    • /
    • pp.15-24
    • /
    • 1966
  • 본 연구실험은 특고배전방식에 대한 제문제중 특히 아래 세 문제에 중점을 두어 기초적자료를 구하는데 연구의 목적을 두었다. 1. 고저압선의 혼촉사고시 중성선의 대지전위상승에 대하여 2. 고압선의 1선지락고장시(특히 고저항접지) 지락저학의 변화와 접지사고검출방법에 대하여 3. 연접한 통신선의 유도장해에 대하여 연구한다.

  • PDF