• Title/Summary/Keyword: 유도초음파 검사

Search Result 139, Processing Time 0.031 seconds

Breast Cancer Screening with MRI (유방암 스크리닝 자기공명영상)

  • Cho, Nariya;Moon, Woo-Kyung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.1-5
    • /
    • 2012
  • Breast MRI is the most accurate adjunctive to the mammography for the screening of breast cancer. Despite lack of randomized controlled trials on the effectiveness of MRI screening, it is now recommended for the women at high risk for breast cancer by the American Cancer Society and the National Comprehensive Cancer Network based on several prospective observational studies. In Korea, a retrospective study reported that preoperative MRI screening of the contralateral breast in women with unilateral breast cancer was associated with reduced metachronous cancer incidence. To introduce breast MRI as a supplemental modality to screening mammography in Korea, standardization and education of interpretation, establishment of MR-guided biopsy and adequate indication, and evaluation of cost-effectiveness and should be preceded.

The Role of Ultrasound Guided Core Needle Biopsy in Thyroid Nodule (갑상선 결절에서 초음파 유도하 중심생검의 역할)

  • Ryu, Yoon-Jong;Ahn, Soon-Hyun
    • Korean Journal of Head & Neck Oncology
    • /
    • v.31 no.1
    • /
    • pp.1-4
    • /
    • 2015
  • Fine needle aspiration cytology(FNAC) holds a main role in assessing thyroid nodules. But nonnegligible rate of thyroid cytology is reported as uncertain, indeterminate or inadequate for diagnosis. Recently, the microhistologic evaluation by core needle biopsy(CNB) under ultrasound sonographical guidance has been reported to show high accuracy for the diagnose of thyroid nodules. Aim of this review was to furnish the state of the art of this topic by summarizing previous published data about indication, diagnostic performance, and complication of CNB in thyroid lesions compared with FNAC

  • PDF

A Study on MsS Guided Wave Scattering from Defects (MsS Guided Wave를 이용한 결함 신호의 분석에 관한 연구)

  • Choi, Boo-Il;Cho, Youn-Ho;Lee, Joon-Hyun;Shin, Dong-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.442-449
    • /
    • 2009
  • An investigation has been made on the relationship between characteristics of torsional mode signal in MsS and SH mode signal in BEM modeling for the defect of stainless steel pipe. In order to compare torsional mode signal with SH mode signal of defect in stainless steel pipe, specimens were made by changing size of depth and width along to circumferential direction 360 degrees. All the defects was detected by torsional mode signal of MsS, especially according to the change of depth size, amplitude of signal was changed. But width change for the circumferential defects has no certain tendency. SH mode signal of BEM modeling shows similar results with torsional mode, with change makes amplitude variation of signal. In this paper, the characteristics of torsional mode and SH mode signals were found. It is possible to predict the circumferential defects for the pipe by SH mode modeling.

Impact and Damage Detection Method Utilizing L-Shaped Piezoelectric Sensor Array (L-형상 압전체 센서 배열을 이용한 충격 및 손상 탐지 기법 개발)

  • Jung, Hwee-Kwon;Lee, Myung-Jun;Park, Gyuhae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.5
    • /
    • pp.369-376
    • /
    • 2014
  • This paper presents a method that integrates passive and active-sensing techniques for the structural health monitoring of plate-like structures. Three piezoelectric transducers are deployed in a L-shape to detect and locate an impact event by measuring and processing the acoustic emission data. The same sensor arrays are used to estimate the subsequent structural damage using guided waves. Because this method does not require a prior knowledge of the structural parameters, such as the wave velocity profile in various directions, accurate results could be achieved even on anisotropic or curved plates. A series of experiments was performed on plates, including a spar-wing structure, to demonstrate the capability of the proposed method. The performance was also compared to that of traditional approaches and the superior capability of the proposed method was experimentally demonstrated.

Reproductive Monitoring and Estrus Induction Using Ultrasonography and Hormone Assay in Dairy Cows III. Estrus Induction Using $PGF_2{\alpha}$ (초음파검사 및 호르몬검사에 의한 젖소 번식검진과 발정유도 III. $PGF_2{\alpha}$ 제제에 의한 발정유도)

  • 오기석;박상국;김방실;고진성;신종봉;백종환;홍기강;문광식;임원호
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.384-388
    • /
    • 2003
  • To establish the method of estrus induction using the injection of PGF$_2$$\alpha$ㆍ the 60 dairy cows treated by PGF$_2$$\alpha$ㆍ at 6, 8, 10, 12, 14, and 16 day of estrous cycle, recpectively. The plasma progesterone concentrations at day of injection of PGF$_2$$\alpha$ㆍ were $1.5\pm$1.3 (mean$\pm$SD) ng/ml at 6 days of estrous cycle, 3.7$\pm$1.4 ng/ml at 8 days, 6.5$\pm$1.8 ng/ml at 10 days, 7.9$\pm$2.0 ng/ml at 12 days, 6.5$\pm$2.5 ng/ml at 14 days, and 2.5$\pm$1.2 ng/m] at 16 days, respectively. The percentages of induction of estrus after PGF$_2$$\alpha$ㆍ treatment were 52.8% at 3th day after treatment, 21.7% at 4th day, 8.3% within 2th day, and ] 7.2% after 5th day, respectively. The percentages of cows conceived at first service after induction of estrus were 73.3% on 16 days of estrous cycle at treatment, 66.7% on 10 and 14 days, 63.3% on 8 and 12 days, and 53.3% on 6 day, respectively. The percentages of cows conceived on first service were 70.5% at 3th day after induction, 66.7% at 4th day and 65% at 5th day, respectively. These results suggest that the PGF$_2$$\alpha$ㆍ treatment at regressing stage of corpus luteum showed high induction of estrus and pregnancy rate, and there were high induction of estrus and pregnancy rate at 3th and 4th day after PGF$_2$$\alpha$ㆍ treatment.

Diagnostic Performance of Blood Culture Bottles for Abscess Culture in Patient with Abdominal Soft Tissue Abscess (복부 연조직 농양 환자에서 농양 배양을 혈액배양병으로 했을 때의 성과 1예)

  • Jo, Kyo Jin;Chang, Chulhun L.;Hwang, Jae-Yeon;Park, Su Eun
    • Pediatric Infection and Vaccine
    • /
    • v.28 no.2
    • /
    • pp.118-123
    • /
    • 2021
  • Culture tests are very important in choosing the appropriate antibiotics for bacterial infections. In some cases, bacteria that could not be identified in standard culture bottles could be detected using blood culture bottles. A previously healthy 13-year-old boy visited our emergency room. He experienced pain, redness, and hardness of periumbilical skin and a fever for five days. There was no history of abdominal surgery and penetrating trauma. Computed tomography showed abscess with cellulitis at the periumbilical soft tissue with no congenital anomaly. Ultrasonography-guided aspiration was performed, and about 8.5 mL of the purulent abscess was aspirated. The abscess was cultured using blood culture bottle. The pus grew Actinomyces radingae and Clostridium ramosum. When performing the pus culture, using blood culture bottles can be more effective and rapid than the standard culture method for the detection of bacterial pathogens.

Pipeline Structural Damage Detection Using Self-Sensing Technology and PNN-Based Pattern Recognition (자율 감지 및 확률론적 신경망 기반 패턴 인식을 이용한 배관 구조물 손상 진단 기법)

  • Lee, Chang-Gil;Park, Woong-Ki;Park, Seung-Hee
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.4
    • /
    • pp.351-359
    • /
    • 2011
  • In a structure, damage can occur at several scales from micro-cracking to corrosion or loose bolts. This makes the identification of damage difficult with one mode of sensing. Hence, a multi-mode actuated sensing system is proposed based on a self-sensing circuit using a piezoelectric sensor. In the self sensing-based multi-mode actuated sensing, one mode provides a wide frequency-band structural response from the self-sensed impedance measurement and the other mode provides a specific frequency-induced structural wavelet response from the self-sensed guided wave measurement. In this study, an experimental study on the pipeline system is carried out to verify the effectiveness and the robustness of the proposed structural health monitoring approach. Different types of structural damage are artificially inflicted on the pipeline system. To classify the multiple types of structural damage, a supervised learning-based statistical pattern recognition is implemented by composing a two-dimensional space using the damage indices extracted from the impedance and guided wave features. For more systematic damage classification, several control parameters to determine an optimal decision boundary for the supervised learning-based pattern recognition are optimized. Finally, further research issues will be discussed for real-world implementation of the proposed approach.

The Effectiveness of Ultrasound-guide Steroid Injection According to Morton's Neuroma Size (모톤씨 신경종 크기에 따른 초음파 유도하 스테로이드 주사 효과의 비교분석)

  • Kim, Hak Jun;Hur, Chang Ryong;Kim, Jae Kyun;Jang, Kyu Seon
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.2
    • /
    • pp.61-65
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the effectiveness of ultrasound-guide steroid injection according to Morton's neuroma size. Materials and Methods: From October 2008 to September 2011, 17 patients (23 cases) diagnosed with Morton's neuroma were investigated. All cases were female and mean age was 52.6 years old. Neuroma were measured by the horizontal and longitudinal length of the mass and underwent ultrasound-guided steroid (5 mg dexamethasone) injection. The efficacy of the injection was determined by Visual Analogue Scale pain score and patient satisfaction(subdivided 4 group-much improved, improved, not improved, aggrevation) Results: 7 of 23(30.4%) cases showed much improved and improved satisfaction and mean longitudinal and horizontal length were $0.71{\pm}0.39cm$ and $0.47{\pm}0.24cm$, respectively. 16 of 23(69.6%) cases showed not improved and aggrevation satisfaction and mean longitudinal and horizontal length were $0.83{\pm}0.42cm$ and $0.54{\pm}0.14cm$, repectively. There was a significant difference in VAS and patient satisfaction in case longitudinal and horizontal length were smaller than 0.5 cm and 0.4 cm. (p<0.05) Conclusion: The ultrasonography is a important modality in diagnosis and treatment of morton's neuroma. Ultrasound-guide steroid injection is effective in case longitudinal and horizontal length were smaller than 0.5 cm and 0.4 cm, respectively.

  • PDF

Finite Element Simulation of Laser-Generated Ultrasound and Interaction with Surface Breaking Cracks (유한요소법을 이용한 레이저 유도 초음파와 표면 균열과의 상호작용 모델링)

  • Jeong, Hyun-Jo;Park, Moon-Cheol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • A finite element method is used to simulate interaction of laser-based ultrasounds with surface breaking tracks in elastic media. The laser line source focused on the surface of semi-infinite medium is modeled as a shear dipole in 2-D plane strain finite elements. The shear dipole-finite clement model is found to give correct directivity patterns for generated longitudinal and shear waves. The interaction of surface waves with surface breaking cracks (2-D machined slot) is considered in two ways. Both the source and receiver are fixed with respect to the cracks in the first case, while the source is moving in another case. It is shown that the crack depth tested in the range of 0.3-5.0mm $({\lambda}_R/d=0.21{\sim}3.45)$ can be measured using the corner reflected waves produced by the fixed laser source. The moving laser source is found to cause a large amplitude change of reflected waves near crack, and the crack whose depth is one order lower than the wavelength ran be detected from this change.

Cryptococcosis with Mediastinal Lymph Node and Lung Involvement in an Immunocompetent Adolescent: A Case Report (정상 면역체계를 가진 청소년에서 발생한 종격동 림프절과 폐 크립토코쿠스증 1예)

  • Lee, Jiyeon;Cho, Chang-Min;Cho, Hyun-Hae;Park, Heae Surng;Kim, Kyung-Hyo
    • Pediatric Infection and Vaccine
    • /
    • v.28 no.2
    • /
    • pp.124-131
    • /
    • 2021
  • Cryptococcus neoformans is a fungus that primarily causes opportunistic infections in immunocompromised hosts. It can also cause various infections in immunocompetent patients. Pulmonary cryptococcosis involving the lymph node is relatively rare in immunocompetent patients. In this report, a previously healthy 17-year-old girl presented with high-grade fever and persistent cough. Chest X-ray and computed tomography (CT) scan revealed an anterior mediastinal conglomerate mass that expanded to the right supraclavicular area. Ultrasound-guided gun biopsy revealed histological evidence of cryptococcosis. Immunological screening tests did not identify immunodeficiency. She recovered completely with a combination therapy of amphotericin B and flucytosine for 2 weeks, followed by fluconazole for 8 months. The characteristics of cryptococcosis involving the mediastinal lymph node and the lung should be understood, and the possibility of cryptococcosis even in immunocompetent hosts should be considered.