• Title/Summary/Keyword: 유도초음파

Search Result 412, Processing Time 0.027 seconds

Musculoskeletal Ultrasound Intervention: Principles & Cautions (초음파를 이용한 침습적 치료: 원칙과 주의점)

  • Oh, Gun-Myung;Lee, Kyung Jae;Min, Byung-Woo;Kim, Dong-Wan
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.38-44
    • /
    • 2013
  • The ultrasound can be used primarily to guide exact needle placement for aspirations of fluids, injections of steroid, and biopsies in musculoskeletal field. Recently, ultrasound-guided intervention is widely used because of several advantages such as real-time performance, relatively inexpensiveness, and getting multiple images without additional radiations. However, the modality is operator dependent and requires detailed knowledge of the relevant anatomy and there have been also reported serious complications related to the procedure. So, authors will discuss about the basic techniques, principles and cautions for the use of ultrasound-guided intervention in musculoskeletal field.

  • PDF

Rare Earth Element Analysis with Chromatography-Inductively Coupled Plasma Atomic Emission Spectrometry and the Comparison of Cross Flow and Ultrasonic Nebulizers (크로마토그래피-유도 결합 플라스마 원자방출 분광법을 이용한 희토류 원소들의 연속적 분석 및 직교형과 초음파분무기의 비교)

Detection of Cracks in feeder Pipes of Pressurized Heavy Water Reactor Using an EMAT Torsional Guided Wave (EMAT의 유도초음파 비틀림 모드를 이용한 가압중수로 피더관의 균열 검출)

  • Cheong, Yong-Moo;Kim, Sang-Soo;Lee, Dong-Hoon;Jung, Hyun-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.136-141
    • /
    • 2004
  • A torsional guided wave mode was applied to detect a crack in a pipe. An array of electromagnetic acoustic transduce. (EMAT that can generate and receive torsional guided ultrasound with the frequency of 200kHz was designed and fabricated for testing a pipe of 2.5 inch diameter Artificial notches with various depths were fabricated in a bent feeder pipe mock-up and the detectability was examined from the distance of 2m of the specimen. The axial notches with the depth of 5% of wall thickness were successfully detected by a torsional mode (T(0,1)) generated by the EMAT However, it was found that the depth of defects was not related to the signal amplitude.

Assessment of Pipe Wall Loss Using Guided Wave Testing (유도초음파기술을 이용한 배관 감육 평가)

  • Joo, Kyung-Mun;Jin, Seuk-Hong;Moon, Yong-Sig
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.295-301
    • /
    • 2010
  • Flow accelerated corrosion(FAC) of carbon steel pipes in nuclear power plants has been known as one of the major degradation mechanisms. It could have bad influence on the plant reliability and safety. Also detection of FAC is a significant cost to the nuclear power plant because of the need to remove and replace insulation. Recently, the interest of the guided wave testing(GWT) has grown because it allows long range inspection without removing insulation of the pipe except at the probe position. If GWT can be applied to detection of FAC damages, it will can significantly reduce the cost for the inspection of the pipes. The objective of this study was to determine the capability of GWT to identify location of FAC damages. In this paper, three kinds of techniques were used to measure the amplitude ratio between the first and the second welds at the elbow area of mock-ups that contain real FAC damages. As a result, optimal inspection technique and minimum detectability to detect FAC damages drew a conclusion.

Fungal Psoas Abscess Successfully Treated by Ultrasonographically Guided Percutaneous Aspiration - A Case Report - (진균성 요근 농양의 초음파 유도하 경피적 천자술을 통한 성공적 치료 - 증례보고 -)

  • Moon, Sang-Ho;Kim, Jin-Hak;Lee, Song;Ahn, Dong-Ki;Kim, Dae-Geun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.1
    • /
    • pp.36-40
    • /
    • 2012
  • Although surgical drainage has been performed in most reported cases of psoas abscess, ultrasonographically guided percutaneous drainage could be effective treatment for psoas abscess. However, utility of percutaneous drainge under ultrasound is less well established. We present a patient in whom fungal psoas abscess was managed by ultrasonographically guided percutaneous aspiration with literature review. Drainage was done by needle aspiration under ultrasound guidance and there was no procedural complication. After aspiration, Candida Albicans was found as a causing organism responsible for abscess and abscess could be successfully treated by repeated aspiration and appropriate antifungal therapy.

  • PDF

Ultrasound-Guided Injections in the Lumbar and Sacral Spine (요추 및 천추부에 대한 초음파 유도하 중재 시술)

  • Ko, Kwang Pyo;Song, Jae Hwang;Kim, Whoan Jeang;Kim, Sang Bum;Min, Young Ki
    • Journal of Korean Society of Spine Surgery
    • /
    • v.25 no.4
    • /
    • pp.185-195
    • /
    • 2018
  • Study Design: Literature review. Objective: Ultrasound-guided injections are a common clinical treatment for lower lumbosacral pain that are usually performed before surgical treatment if conservative treatment fails. The aim of this article was to review ultrasound-guided injections in the lumbar and sacral spine. Summary of Literature Review: Ultrasound-guided injections, unlike conventional interventions using computed tomography or C-arm fluoroscopy, can be performed under simultaneous observation of muscles, ligaments, vessels, and nerves. Additionally, they have no radiation exposure and do not require a large space for the installation of equipment, so they are increasingly selected as an alternative method. Materials and Methods: We searched for and reviewed studies related to the use of ultrasound-guided injections in the lumbar and sacral spine. Results: In order to perform accurate ultrasound-guided injections, it is necessary to understand the patient's posture during the intervention, the relevant anatomy, and normal and abnormal ultrasonographic findings. Facet joint intra-articular injections, medial branch block, epidural block, selective nerve root block, and sacroiliac joint injections can be effectively performed under ultrasound guidance. Conclusions: Ultrasound-guided injections in the lumbar and sacral spine are an efficient method for treating lumbosacral pain.

Comparison of the Clinical Outcomes of an Ultrasound-Guided and C-Arm Guided Cervical Nerve Root Block (초음파와 방사선 투시장치를 이용한 경추 신경근 차단술의 임상결과 비교)

  • Ha, Dae Ho;Shim, Dae Moo;Kim, Tae Kyun;Oh, Sung Kyun;Lee, Hyun Jun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.78-84
    • /
    • 2020
  • Purpose: This paper compares the clinical outcomes of patients who were treated with a cervical nerve block by ultrasound and C-arm and reports the complication. Materials and Methods: A total of 97 patients were treated with an ultrasound-guided nerve root block from May 1, 2015 to February 8, 2018. On the other hand, 94 patients were treated with a C-arm guided nerve root block. The consequences of the cervical pain and the radiating pain before and after the procedures were reviewed using the verbal numeric rating scale (VNRS). In addition, the complications related to the procedures from the daily notes from the chart were inspected. Results: Sixty-six cases out of 97 cases of ultrasound-guided nerve root block were enrolled in the study. The average age of the patients was 57 years, including 41 males and 25 females. Seventy seven out of 94 cases by a C-arm guided root block were included in the study. The average age of the patients was 55 years, including 40 males and 37 females. Before the nerve root block, the mean numeric rating pain scale (NRS) of the cervical pain in ultrasound-guided block decreased from 5.4 points to 2.7 points at three weeks and 1.4 points at six weeks (p=0.0023, p<0.001), and 3.1 points in the C-arm (p<0.001, p<0.001) at three weeks and 1.5 points at six weeks (p<0.001, p<0.001). In the case of radiating pain, the mean NRS in the ultrasound-guided nerve root block group improved from 6.3 points after the procedure to 2.8 points at three weeks and 1.5 points at six weeks (p<0.001, p<0.001). In the C-arm guided nerve root block group, the NRS improved from 7.4 points after the procedure to 3.3 points at three weeks and 1.9 points at six weeks. In the case of complications, Horner's syndrome and propriospinal myoclonus were observed in one case of C-arm guided block group. Conclusion: The clinical results of the patients who underwent ultrasound-guided cervical nerve root block were not significantly different from those who underwent a C-arm guided cervical nerve root block.

Defect ratio evaluation of the rock bolt grouting using the reflection method of guided ultrasonic waves (유도초음파의 반사법을 이용한 록볼트 그라우팅의 결함비율 평가)

  • Yu, Jung-Doung;Bae, Myeong-Ho;Han, Shin-In;Lee, In-Mo;Lee, Jong-Sub
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.10 no.3
    • /
    • pp.221-232
    • /
    • 2008
  • Rock bolts have been installed into rockmass as a main support system. In order to evaluate the rock bolt integrity using non-destructive technique, the transmission method of the guided ultrasonic wave has been successfully performed. For the transmission method, however, the source for the generation o# guided ultrasonic waves should be installed at the end of the steel bar during construction of the rock bolt in the field. The purpose of this study is to suggest a reflection method that the source and the receiver are installed on the head of the steel bar. The reflection method is compared with the transmission method using non-embedded rock bolts and rock bolts embedded in concrete block. In this experiment, the piezo disc element is used as the source and the AE sensor is used as the receiver. The wavelet transform is applied to determine the energy velocity. The experimental studies show that the reflection method produces almost identical value of the transmission method, and the energy velocity increases with the defect ratio. This study suggests that the reflection method of the guided ultrasonic wave may be a suitable method fur the rock bolt integrity evaluation in the field.

  • PDF

A Study on the Optimum Generation Condition of Ultrasonic Guided Waves for Insulation Pipelines (단열된 배관의 유도초음파 최적 발생조건 선정에 관한 연구)

  • Lee, Dong-Hoon;Cho, Hyun-Joon;Kang, To;Park, Dong-Jun;Kim, Byung-Duk;Huh, Yun-Sil;Lee, Yeon-Jae
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.50-57
    • /
    • 2016
  • Pipeline is one of the most abundant components in petrochemical plant. It plays a critical role in transporting fluids. Some pipelines are thermally insulated by wrapping them with insulating materials to prevent the loss of energy. However, when corrosion begins under insulation, it cannot be easily seen without unwrapping the cover, and thus corrossion should be detected using a non-destructive ways such as ultrasound guided wave. In this paper, the piping where the CUI (Corrosion Under Insulation) which occurs in the insulation parts guided waves effectively the optimum condition which is theoretical for selected guided waves phase velocity dispersion curve and wave-structure. The results of this study are expected to be directly utilized for onsite inspection of pipeline's CUI in many petrochemical plants.

Integrity evaluation of rock bolts in the field by using hammer-impact reflection method (해머 타격 반사법을 이용한 현장 록볼트 건전도 평가)

  • Yu, Jung-Doung;Bae, Myeong-Ho;Lee, Yong-Jun;Min, Bok-Ki;Lee, In-Mo;Lee, Jong-Sub
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.1
    • /
    • pp.47-56
    • /
    • 2009
  • Rock bolts and shotcrete play a crucial role as a main support system in the underground space. Thus, the safety of the underground space may be affected by the defect of rock bolts. In order to evaluate the rock bolt integrity by using non-destructive technique, the transmission method of the guided ultrasonic waves, which are generated by using the piezo disk elements has been successfully performed. The energy generated by the piezo disk elements, however, is not enough for the rock bolts in the field. In addition, the piezo disk elements should be installed at the end of the steel bar during construction of the rock bolts. The purpose of this study is the devolvement of the reflection method, which may generate enough energy, and the application in the field rock bolts. Both laboratory and field tests are carried out. The guided ultrasonic waves with high energy are generated by the hammer impact with the center punch, and the AE sensor is used to measure the reflected guided waves. The received guided waves are analyzed by the wavelet transform. The peak value of the wavelet transform produces the energy velocity, which is used for the evaluation of the rock bolt integrity. The energy velocity increases with an increase in the defect ratio in both laboratory and field rock bolts. This study demonstrates that the hammer-impact reflection method may be a suitable method for the evaluation of the rock bolt in the field.