Study on the scheme to reinforce military security system based on location information (위치정보를 이용한 군 보안체계 강화 방안)

  • Kim, Yun Young;Namkung, Seung Pil
    • Convergence Security Journal
    • /
    • v.15 no.3_1
    • /
    • pp.83-90
    • /
    • 2015
  • Current PKI system will confront more dangerous elements in the wireless network. Accordingly, this study suggests a plan to strengthen authentication system plan with using access control and encryption to the location. Locational information collecting devices such as GPS and sensor are utilized to create a new key for authentication and collect locational information. Such a key encodes data and creates an authentication code for are access control. By using the method suggested by this study, it is possible to control access of a military secret from unauthorized place and to protect unauthorized user with unproposed technique. In addition, this technique enables access control by stage with utilizing the existing PKI system more wisely.

Tightness of specimen sealing box in 20 L test chamber to evaluate building materials emitting pollutants (건축자재에서 방출되는 오염물질 평가 시 사용되는 20 L 시험챔버 시편홀더의 기밀성 개선)

  • Shin, Woo Jin;Lee, Chul Won;Kim, Man Goo
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.261-267
    • /
    • 2007
  • The 20 L small chamber test method is to evaluate pollutants such as TVOC, formaldehyde emitted from building materials. This method was only designed to evaluate the surface emission of sample exposed in the chamber. In this method, building materials cut with a fixed standard size are fixed in a sample sealing box. The sample sealing box is put into the 20 L test chamber. This chamber is ventilated at a standard air change rate with purified air for 7 days then the sample from the chamber is collected and analyzed to measure the emission rate of TVOC and formaldehyde. In this method, however, if the sealing box does not guarantee airtightness, accurate evaluation for the building materials can not be achieved due to the pollutants emitted from edge of the sample so called, edge effect. This edge effect can be much greater when evaluating panels such as plywood, flooring due to their surface treatment. In this study, flooring was tested to check airtightness of the sample sealing box with analytic results between 1L and 20 L test chamber. Furniture materials like LPM coated one side surface treatment and MDF coated both sides surface treatment with LPM were tested to identify whether the improvement of the sample sealing box airtightness is possible with the comparison between existing and improved test method that low VOC emission tape was used to seal the sample edge. After 7 days, MDF TVOC emission rate was different according to the existence and nonexistence of tape. The emission rate of the existing test method was $0.009mg/m^2h$ and that of improved test method was $0.003mg/m^2h$. Relative standard deviation for the existing test method was $0.004mg/m^2h$ and relative standard deviation for the improved test method was $0.002mg/m^2h$ when the same sample was analyzed three times. The improved test method in this study using low VOC emission tape was effective and able to reduce the heterogeneous effect of the edge from the sample sealing box.

난방운전의 최적제어방안 중심 공동주택의 열성능 향상 방안

  • 이승언;안태경;강재식
    • 월간 기계설비
    • /
    • s.46
    • /
    • pp.74-89
    • /
    • 1994
  • 현재 범국가적 차원에서 지속적인 국가 경제 발전과 국제수지 개선을 위하여 추진되고 있는 정부의 에너지 절약사업에서 건물부문이 차지하는 에너지절약 효과는 막중하다. 특히 전체주택에서 공동주택이 차지하는 비율은 1990년에 32.1$\%$, 서울시의 경우 51.3$\%$로 전체 주택의 과반수를 넘어섰으며, 수도권의 대단위 아파트단지의 개발과 함께 공동주택의 증가추세는 당분간 지속될 전망이다. 본 연구는 공동주택의 최적난방 운전기법 개발을 위한 1차년도의 연구로서 현행 공동주택의 난방운전 실태를 조사, 분석하고 각 난방법에 따른 문제점 및 최적제어 알고리즘의 개발을 위한 자료 도출을 주 목적으로 진행되었다. 1차년도에 수행된 연구의 주요 내용을 살펴보면 다음과 같다. 공동주택의 난방에너지 소비현상은 단지에 따라 최대 3배이상의 열사용량에 차이가 있는 것으로 나타났다. 열사용량의 차이는 건축의 기본 열성능, 설비시설의 수준 및 노후화정도에 영향을 받으나 동일 연대의 단지들에서도 최대 80$\%$이상의 열사용량이 차이를 보이고 있었으며 이는 기계실 및 각 세대의 난방운전방법 및 제어수준에 따른 것으로 평가되었다. 세대의 층별, 위치별 열사용량 분석에 의하면 층별 열사용량차이가 큰 것으로 분석되었으며, 특히 최상층부와 최하층부의 열사용량이 뚜렷이 많이 나타나 단열성능의 강화가 요구되는 것으로 나타났다. 한편 샘플단지에 대한 측정 데이터를 통해 적정 열량공급시간대의 설정과 외기온의 변화에 따른 적정 온수공급온도의 설정조건 및 유량제어 효과등에 대한 분석 및 검토를 하였으며, 이를 통해 2차년도의 개발목표인 최적운전제어 방안의 제시를 위한 자료를 구축하였다. 또한 각 세대의 기밀성능이 공동주택의 열성능에 미치는 영향을 도출하기 위하여 샘플단지에 대해 트레스가스 측정법과 Blower Door법에 의하여 환기 및 기밀상태를 평가 하였으며 측정주호에 대한 환기를 예측할 수 있는 환기예측평가식을 제시하였다.

  • PDF

A Study on Safe Authentication Method for Security Communication in RFID Environment (RFID 환경에서 보안 통신을 위한 안전한 인증 방안에 관한 연구)

  • Ko, Hoon;Kim, Bae-Hyun;Kwon, Moon-Taek
    • Convergence Security Journal
    • /
    • v.5 no.3
    • /
    • pp.59-65
    • /
    • 2005
  • Ubiquitous computing environment has a lot of different things as for applying existing security technical. It needs authentication method which is different kinks of confidence level or which satisfies for privacy of user's position. Using range localizes appoint workstation or it uses assumption which is satify environment of client in Kerberos authentication method which is representation of existing authentication method but it needs new security mechanism because it is difficult to offer the condition in ubiquitous computing environment. This paper want to prove the result which is authentication method for user authentication and offering security which are using wireless certificate from experiment in ubiquitous environment. Then I propose method which is offering security and authentication in ubiquitous environment.

  • PDF

An Anonymous Authentication Scheme for Health Information Push Service Based on Indoor Location in Hospital (병원 실내 위치기반 의료정보 푸쉬 서비스를 위한 익명 인증 스킴)

  • Ahn, Hae-Soon;Yoon, Eun-Jun;Nam, In-Gil
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.5C
    • /
    • pp.410-419
    • /
    • 2012
  • This paper proposes a secure and efficient anonymous authentication scheme for health information push service based on indoor location in hospital. The proposed scheme has the following benefits: (1)It is just based on a secure one-way hash function for avoiding complex computations for both health care operations users and health care centers. (2)It does not require sensitive verification table which may cause health care centers to become an attractive target for numerous attacks(e.g., insertion attacks and stolen-verifier attacks), (3)It provides higher security level (e.g., secure mutual authentication and key establishment, confidential communication, user's privacy, simple key management, and session key independence). As result, the proposed scheme is very suitable for various location-based medical information service environments using lightweight-device(e.g., smartphone) because of very low computation overload on the part of both health care operations users and health care centers.

Anti-Theft Boot Loader System on Low Level Kernel (커널 하위 계층에서의 도난 방지 부트로더 시스템)

  • Kim, Byeoung-Wook;Yu, Joo-hyun;Jung, Dong-Hwan;Lee, Hyun-Ar
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.04a
    • /
    • pp.28-30
    • /
    • 2016
  • 정보화 시대에서 노트북을 도난당하는 것은 금전적인 손해 뿐만 아니라 작업 내용, 기밀 정보와 같은 금전적으로 환산할 수 없는 중요 정보들을 잃어버리는 점에서 그 피해와 손실이 크다. 본 논문에서는 노트북 도난에 의한 피해와 손실을 최소화 할 수 있는 도난 방지 부트로더 시스템을 제시한다. 시스템은 사용자 노트북의 부트로더 레벨에서 사용자 인증과 전방 사진 및 위치 정보를 수집하고 전송하여, 노트북 내 정보가 유출되는 것을 방지하는 동시에 범인 검거 및 노트북 회수를 위한 정보를 사용자에게 제공한다.

A Scheme on Secure and Fast Handoff Using Location Information with AAA (AAA상에서 위치정보를 이용한 안전하고 빠른 Handoff 기법 설계)

  • Lee, Deok-Gyu;Lee, Im-Yeong
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07a
    • /
    • pp.175-177
    • /
    • 2005
  • 여러 네트워크에서 사용자의 이동이나 인증 결과 처리를 최소하기 위한 서비스가 발전하고 있다 그러나 인증, 권한 검증, 과금을 지원하는 AAA 기반의 망에서는 매 등록이 발생할 때 마다 새로운 세션 키가 필요하며 이를 위해 홈 망까지 등록 절차가 수행되어야 한다. 이것은 이동 노드 재인증 절차와 방문 홈에서 홈 망까지의 통신으로 인한 지연이 발생할 수 있다. 이같은 지연을 방지하기 위해 본 논문에서는 홈망의 AAA 서버와 상관없이 이전의 할당된 세션 키를 이용하여 빠른 핸드오프 기법을 제안한다. 본 제안 방식은이전 방문 에이전트와 새로운 방문 에이전트간에 제 3자로 하여금 키를 공유하고 홈망까지의 통신이 필요없고 세션키의 기밀성과 무결성이 보장되도록 수행할 수 있다.

  • PDF

Data protection for mobile devices via location restriction (장소 한정을 통한 모바일 기기 데이터 보호 기법)

  • Jung, Ji Jung;Park, Ji-Min;Lee, JongHyup
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.04a
    • /
    • pp.322-324
    • /
    • 2014
  • 모바일 환경이 발달함에 따라서 사용자의 개인 모바일 기기에 저장되었던 민감한 개인정보 및 기업의 비밀과 같이 기밀성을 필요로 하는 데이터의 누출 사고가 빈번히 발생하고 있다. 본 논문에서는 모바일 기기의 데이터를 지정된 장소에서만 안전히 사용할 수 있도록 하는 기법을 제안한다. 제안된 기법은 공개키 암호화 시스템을 바탕으로 지정된 장소에서만 발행되는 키를 통해서만 모바일 기기의 접근이 가능하게 함으로써 데이터 사용 위치를 강제하고, 의도하지 않은 데이터 누출을 방지한다.

A Secret Sharing Mechanism for Multi-Hop Sensor Nodes Environment Using the Third Node (제 3의 노드를 이용한 다중 홉 환경의 센서 노드를 위한 안전한 비밀값 공유 기법)

  • Cho, Eung Jun;Hong, Choong Seon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.11a
    • /
    • pp.1297-1299
    • /
    • 2010
  • 무선 통신에서는 무선 통신의 브로드캐스트한 특성으로 데이터의 기밀성 유지를 위한 암호화가 매우 중요하다. 특히 무선 센서 네트워크(WSN - Wireless Sensor Network)의 경우 일반적인 PC와는 다르게 다양한 환경에 위치할 수 있어 공격자에게 더 쉽게 노출 될 수 있는 문제점을 가지고 있다. 이런 환경에서 미리 저장된 해쉬 함수나 비밀 값에 의존한 키 분배를 할 경우 저장된 값이 노출될 경우 심각한 문제를 초래하게 된다. 그리고 D-H 키 분배 알고리즘의 경우 키 값을 안전하게 도출을 할 수 있지만 키를 도출한 대상에 대한 인증의 부재와 멀티 홉 환경에서 중간자 공격에 취약한 문제점을 드러내고 있다. 본 논문에서는 이런 문제를 해결하기위해 기존 연구를 응용하여 멀티 홉 환경에서 무선 통신의 특성을 이용한 비밀값 공유와 제 3의 노드를 이용한 간단한 인증이 가능한 기법을 제안한다.

원지점 차넣기 모타 적용 잠입노즐 기초 기술 개발

  • 노태호;황종선;조인현
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.32-32
    • /
    • 2000
  • 잠입노즐은 로케트 추진기관의 길이 및 중량을 감소시켜 체계설계의 관점에서 볼 때 많은 이점을 제공한다. 본 연구에서는 3단형 과학로케트 원지점 차넣기 모타(apogee kick motor)에 적용하기위한 잠입노즐의 기초기술 개발에 주안점을 두었다. 고고도에서 저속으로 회전하며 비행하는 원지점 차넣기 모타를 제작하기위해서 체계 요구성능에 의해 예상된 실물형의 50% 크기에 해당하는 축소형 잠입노즐을 제작하였다. 잠입노즐은 잠입부의 내외부가 고온의 추진제 연소가스에 노출된 상태에서 노즐 내부 압력 외에 연소실압에 의한 외부압력이 작용하므로 이를 고려한 열 및 구조설계가 중요하다. 본 연구에서는 노즐 수렴부와 목부에 일체형 그라파이트 소재를 적용하고 확장부 내열재 및 잠입부 배면내열재에 탄소/페놀 복합재를 노즐 내열재로 사용하였다. 그리고 이들의 구조적 지지를 위해 스틸구조물을 적용하였다. 적용된 스틸구조물에는 K형 열전쌍을 이용해 내열재와 구조물 온도를 측정할 수 있는 관통구멍 및 나사부를 구조물 외변에 가공하였다. 열전쌍은 노즐 목직경의 2, 4배 되는 확장부 내열재 단면위치의 2mm와 4mm 깊이와 구조물 내면 및 외면의 4개소에 열전쌍을 부착하여 지상연소시험시 노즐 내열재와 구조물의 온도분포를 관찰한다. 그리고 노즐 조립시 확장부 내열재와 구조물에 각 각 반원형 홈을 내어 여분의 접착제가 원형 홈에 밀려들어가 경화되어 노즐 기밀유지와 체결력을 향상시킬 수 있는 원형공간 접착제 충전 공법을 적용하여 실제모타에 대한 적용가능성을 지상연소시험을 통해 확인한다.

  • PDF