• Title/Summary/Keyword: 위치모수

Search Result 134, Processing Time 0.024 seconds

The Present State of Food Serviee by the Covered Wagon Bars (포장마차 영업실태조사(營業實態調査))

  • Yoon, Eun-Young;Choi, Kyung-Suk;Park, Young-Sook;Mo, Su-Mi
    • Journal of the Korean Society of Food Culture
    • /
    • v.3 no.2
    • /
    • pp.187-195
    • /
    • 1988
  • In accordance with the rapidly growing number of street food service without a registration, a study was undertaken to determine the present state of food service by the covered wagon bar, through an investigation in Jamwondong, around the south gate market and Kangnam subway station, in Seoul, between July 25th and August 25th of 1987. The survey was comprised of three parts: 1) foodservice operation in covered wagon, 2) personal and food handling hygiene, 3) food behaviors of customers. A total of 54 covered wagon bars, consisting of 51.8% mobile bars and 48.2% non-mobile bars, operating in the above three locations, were investigated. Survey results show non-mobile covered wagon bars to be more popular among persons in their thrities and fourties than among teens or the elderly; also among males than females; among company employees and college students than others. Seventy five percent of the mobile covered wagon bars served snack type foods and others served wine and foods for wine, in contrast to hundred percent of the non-mobile covered wagon bars served wine and foods for wine. The survey found many problems of hygiene, in method of food purchasing, menu planning, food preparation, dish washing treatment of leftovers and water supply, as well as personal hygiene. However, customers prefer the casual and popular atmosphere at the counter of the covered wagon bar. Finally, the study emphasizes a need for better operation of covered wagon bar, improvement of food stuff handling and the way of food services and personal hygiene. A change of the registration system from the illegal operation are urgently needed for better quality food services of covered wagon bars.

  • PDF

Characteristics of Sr0.92Y0.08Ti1-xVxO3-δ (x = 0.01, 0.04, 0.07, 0.12) Anode for Using H2S Containing Fuel in Solid Oxide Fuel Cells (H2S를 포함하는 연료를 사용하기 위한 고체산화물 연료전지용 Sr0.92Y0.08Ti1-xVxO3-δ 연료극 특성)

  • Jang, Geun Young;Kim, Jun Ho;Mo, Su In;Park, Gwang Seon;Yun, Jeong Woo
    • Korean Chemical Engineering Research
    • /
    • v.59 no.4
    • /
    • pp.557-564
    • /
    • 2021
  • Sr0.92Y0.08Ti1-xVxO3-δ (SYTV) with perovskite structure was investigated as an alternative anode to utilize H2S containing fuels in solid oxide fuel cells. To improve the electrochemical performance of Sr0.92Y0.08TiO3-δ (SYT), vanadium(V) was substituted to titanium(Ti) at the B-site of the SYT perovskites. The SYTV synthesized by the Pechini method was chemically compatible with the YSZ electrolyte without additional by-products formation under the cell fabricating conditions. As increasing V substitution amounts, the oxygen vacancies increased, resulting to increasing ionic conductivity of the anode. The cell performance in pure H2 at 850 ℃ is 19.30 mW/cm2 and 34.87 mW/cm2 for a 1 mol.% and 7 mol.% of V substituted anodes, respectively. The cell performance using H2 fuel containing 1000 ppm of H2S at 850 ℃ was 23.37 mW/cm2 and 73.11 mW/cm2 for a 1 mol.% and 7 mol.% of V substituted anodes, respectively.

A Preliminary Study of Ecological Aspects of Food on a Kind of Gom-Tang(Beef Soup made with Internal Organs and Bone) Intake (식생태학적(食生態學的) 관점(觀點)에서 본 곰탕류(類) 섭취(攝取)에 관한 예비적연구(豫備的硏究))

  • Kwon, Sun-Ja;Adachi, Miyuki;Mo, Su-Mi;Choi, Kyung-Suk;Kim, Ju-Hye;Koh, Hee-Jung
    • Journal of the Korean Society of Food Culture
    • /
    • v.6 no.4
    • /
    • pp.421-432
    • /
    • 1991
  • This study was conducted to investigate the intake of a kind of Gom-Tang (Beef soup made with internal organs and bone), which is the Korean traditional food, and factors affecting the eating behavior of customers. Two hundred male customers of a H Korean Restaurant specialized in Gom-Tang, which is a well-known restaurant in Seoul, were surveyed from June 26 to 29, 1990. The results were shown as follows. (1) ${\ulcorner}$Frequency of intake${\lrcorner}$ and ${\ulcorner}$preference${\lrcorner}$ were very high. Those who took a kind of Gom-Tang ${\ulcorner}$more than once a week${\lrcorner}$ were 66.5% of the subjects. Those who evaluated ${\ulcorner}$good${\lrcorner}$ for the taste and flavor were 86.5% and 59.0% of the subjects, respectively. (2) The reasons why they chose a kind of Gom-Tang from among many Korean traditional foods were ${\ulcorner}$preference${\lrcorner}$ and ${\ulcorner}$phygiological condition${\lrcorner}$ in ${\ulcorner}$high frequency of intake${\lrcorner}$ group. ${\ulcorner}$Phygiological condition${\lrcorner}$ was more critical factor than ${\ulcorner}$preference${\lrcorner}$ in ${\ulcorner}$low frequency of intake${\lrcorner}$ group. (3) The effect of the intake of a kind of Gom-Tang on health was evaluated as ${\ulcorner}$healthy${\lrcorner}$ (80.5%). ${\ulcorner}$No effect${\lrcorner}$ and ${\ulcorner}$harmful${\lrcorner}$ were 30.5% and 6.5%, respectively. (4) ${\ulcorner}$High frequency of intake${\lrcorner}$ group, mainly more than 50 years of age, had a high ${\ulcorner}$preference${\lrcorner}$ and ${\ulcorner}$food knowledge${\lrcorner}$ as well as positive ${\ulcorner}$eating behavior${\lrcorner}$ and ${\ulcorner}$healthy state${\lrcorner}$, ${\ulcorner}$Middle frequency of intake${\lrcorner}$ group, mainly the forties, had a high ${\ulcorner}$preference${\lrcorner}$, but had less positive ${\ulcorner}$eating behavior${\lrcorner}$ than ${\ulcorner}$high frequency of intake${\lrcorner}$ group. ${\ulcorner}$Low frequency of intake${\lrcorner}$ group, mainly the twenties and thirties, had a medial ${\ulcorner}$preference${\lrcorner}$. They took a kind of Gom-Tang for reasons of ${\ulcorner}$on the recommendation of friends${\lrcorner}$ better than ${\ulcorner}$preference${\lrcorner}$. Foregoing results showed that ${\ulcorner}$a kind of Gom-Tang${\lrcorner}$ was a typical food recognized as ${\ulcorner}$healthy${\lrcorner}$ as well as ${\ulcorner}$delicious${\lrcorner}$. This may suggest that ${\ulcorner}$a kind of Gom-Tang${\lrcorner}$ is a candidate for the effective food on nutritional education.

  • PDF

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF