• Title/Summary/Keyword: 위생성

Search Result 4,772, Processing Time 0.045 seconds

A Study on Dosimetry for Small Fields of Photon Beam (광자선 소조사면의 선량 측정에 관한 연구)

  • 강위생;하성환;박찬일
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.57-68
    • /
    • 1994
  • Purpose : The purposes are to discuss the reason to measure dose distributions of circular small fields for stereotactic radiosurgery based on medical linear accelerator, finding of beam axis, and considering points on dosimetry using home-made small water phantom, and to report dosimetric results of 10MV X-ray of Clinac-18, like as TMR, OAR and field size factor required for treatment planning. Method and material : Dose-response linearity and dose-rate dependence of a p-type silicon (Si) diode, of which size and sensitivity are proper for small field dosimetry, are determined by means of measurement. Two water tanks being same in shape and size, with internal dimension, 30${\times}$30${\times}$30cm$^3$ were home-made with acrylic plates and connected by a hose. One of them a used as a water phantom and the other as a device to control depth of the Si detector in the phantom. Two orthogonal dose profiles at a specified depth were used to determine beam axis. TMR's of 4 circular cones, 10, 20, 30 and 40mm at 100cm SAD were measured, and OAR's of them were measured at 4 depths, d$\sub$max/, 6, 10, 15cm at 100cm SCD. Field size factor (FSF) defined by the ratio of D$\sub$max/ of a given cone at SAD to MU were also measured. Result : The dose-response linearity of the Si detector was almost perfect. Its sensitivity decreased with increasing dose rate but stable for high dose rate like as 100MU/min and higher even though dose out of field could be a little bit overestimated because of low dose rate. Method determining beam axis by two orthogonal profiles was simple and gave 0.05mm accuracy. Adjustment of depth of the detector in a water phantom by insertion and remove of some acryl pates under an auxiliary water tank was also simple and accurate. TMR, OAR and FSF measured by Si detector were sufficiently accurate for application to treatment planning of linac-based stereotactic radiosurgery. OAR in field was nearly independent of depth. Conclusion : The Si detector was appropriate for dosimetry of small circular fields for linac-based stereotactic radiosurgery. The beam axis could be determined by two orthogonal dose profiles. The adjustment of depth of the detector in water was possible by addition or removal of some acryl plates under the auxiliary water tank and simple. TMR, OAR and FSF were accurate enough to apply to stereotactic radiosurgery planning. OAR data at one depth are sufficient for radiosurgery planning.

  • PDF

A study on the noodle quality made from pea starch-wheat composite flour (완두 전분을 첨가한 국수의 품질특성)

  • 김은주;윤재영;김희섭
    • Korean journal of food and cookery science
    • /
    • v.18 no.6
    • /
    • pp.692-697
    • /
    • 2002
  • The purpose of this study is to investigate the characteristics of the doughs and noodles cooked with the pea starch-wheat composite flour which was substituted with 20% and 30% of pea starch for the flour by the mechanical and sensory evaluation. Wheat dough had the most cohesive property among various composite non.(p<0.05) There was no significant differences in weight gain after cooking among various noodles. The more the pea starch was subsituted, the lighter the color was shown by increasing L value. It was also noted that the b value was decreased significantly. While pea starch noodle were more transparent in appearance and less smooth in the texture, corn starch-wheat composite flour noodle was sorter in the texture significantly. There was no significant difference on the hardness between wheat and pea stach composite flour noodles. There were also no significant differences in stickiness, chewiness and overall acceptability among various noodles. Considering mechanical and sensory results, the composite flour with 20% substitution of pea starch for flour was more suitable for the production of the noodle than those of 30% substitution of pea starch.

Quality Change of Red Meat by Chlorine Dioxide Treatment during Storage (이산화염소 처리에 의한 적색육의 저장 중 품질변화)

  • Lee, Seung-Hwan;Shin, Hee-Young;Ku, Kyoung-Ju;Jin, You-Young;Jeon, So-Jeong;Chae, Hyeon-Seok;Song, Kyung-Bin
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.2
    • /
    • pp.222-227
    • /
    • 2007
  • The effects of chlorine dioxide ($ClO_2$) treatment on the quality changes of pork and beef were examined. Pork belly and beef tenderloin samples were treated with 30, 50, and 100 ppm of $ClO_2$ solution, respectively, and stored at $4{\pm}1^{\circ}C$. The $ClO_2$ treatment of pork and beef during storage decreased total aerobic bacteria, yeast, and mold counts with increasing concentration of $ClO_2$. The total aerobic bacterial counts for the pork belly treated at 100 ppm of $ClO_2$ increased from 1.48 log CFU/g immediately following treatment to 4.73 log CFU/g after 10 days, while the control increased from 2.19 log CFU/g to 6.22 log CFU/g. For the beef tenderloin, the total aerobic bacterial counts increased from 3.98 log CFU/g to 5.97 log CFU/g after 10 days, and a $ClO_2$ treatment at 100 ppm resulted in an increase from 3.13 log CFU/g to 4.73 log CFU/g. The pH and volatile basic nitrogen (VBN) values of the $ClO_2-treated$ pork and beef, as well as the control groups, increased during storage, and there were no significant changes among the treatments. The thiobarbituric acid reactive substance (TBARS) values of the $ClO_2-treated$ samples were slightly higher than those of the control. Sensory evaluation results showed that the pork and beef samples were not acceptable at day 8 and 6 of storage, respectively. These results indicate that $ClO_2$ treatment could be useful in improving microbial safety and quality of both pork and beef.

An Approach for Enhancing Current Korean e-Grocery Business Focusing on Delivery Service Alternatives (한국의 e-Grocery 배송서비스 대안에 관한 연구)

  • Koo, Jong-Soon;Lee, Jung-Sun;Jeon, Dong-Hwa
    • International Commerce and Information Review
    • /
    • v.13 no.3
    • /
    • pp.169-201
    • /
    • 2011
  • There was a new wave in grocery business with development of information and technology, thus a movement from traditional stores to online stores, In order to expand the scale of traditional supermarket and to satisfy the customers' needs, they provide offline and online services simultaneously. This paper is based on the previous studies which had been researched in developed countries from late 1990s to early 2000s and the purpose of this study is to introduce the idea and operation system of e-Grocery business. Moreover, we suggest the alternatives on delivery service methods in order to satisfy the customers' needs through analyzing the current condition of e-Grocers in Korea. According to the result of this study, Korean e-Grocers offer only attended home delivery services. In our opinion, Korean supermarkets have to take hybrid model which Tesco.com is using. There are some alternatives to increase the profits of Korean e-Grocers and to provide better services to their customers as follows: As an alternatives for delivery services, picking service is the easiest and cheapest way to apply for supermarkets. This is very useful for working women and also it is possible to order by smartphone recently. They can order the goods to the closest local supermarkets from working place, and then they pick them up on the way home from working off. In order to improve the quality of delivery services, to use the reception box will be the way to provide better services to the customers. The reception box is a way to protect the quality of goods such as fresh-cut product, which require the freshness through the temperature adjustment, and also to keep the safety of ordered goods through locking system Through this system, supermarkets are able to use attended or unattended services under the customers' satisfaction. However, using the reception box is expensive, so shared reception box will be an alternative. As an alternative for development of e-Grocery business, the advertisement for e-Grocery business has to be supported in order to attract potential customers in e-Grocery business. Furthermore, the main concerns of e-Grocery business such as the sanitation and safety of goods, and convenience must be guaranteed in order to keep the loyal customers and to attract new customers.

  • PDF

Physiological and Ecological Characteristics of Hemolytic Vibrios and Development of Sanitary Countermeasure of Raw Fisheries Foods 3. Growth Factor and Antibiotic Susceptibility of Vibrio cholerae non-O1 FM-3 Isolated from Sea Water (용혈독소를 생산하는 기수성 비브리오균의 생리${\cdot}$생태적 특성과 수산식품의 위생대책 3. 해수에서 분리된 Vibrio cholerae non-O1 FM-3의 생육인자와 항생제 감수성)

  • KIM Shin-Hee;PARK Mi-Yeon;PARK Uk-Yeon;KIM Young-Man;CHANG Dong-Suck
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.4
    • /
    • pp.550-555
    • /
    • 1997
  • Vibrio cholerae non-O1 (V. cholerae non-O1) was previously called nonagglutinable or noncholera vibrios, since it fails to react with polyvalent O1 antisera. This organism is biochemically and genetically indistinguishable from V. cholerae O1 except serological difference. V. cholerae non-O1 strains are often detected in the environment including bays, estuaries, and fresh water, and also found in food. Therefore it is designated food borne bacterium in Japan. However, research papers on V. cholerae non-O1 are very rare in Korea. In order to investigate bacteriological characteristics of V. cholerae non-O1, we isolated V. cholerae non-O1 from the environmental sea water. Among the isolated V. cholerae non-O1 strains, we selected the strain which had the most strong hemolytic activity, named as V. cholerae non-O1 FM-3. The optimum growth conditions of V. cholerae non-O1 FM-3 were $37^{\circ}C$ and pH 8.5 in BHI broth (containing $0.5\%$ sodium chloride), and it grew better than V. cholerae non-O1 ATCC 25872. But both were not able to grow in BHI broth added $5.0\%$ of sodium chloride or adjusted to pH 5.0. According to the experimental results on the susceptibility test against various antibiotics, there were no significant differences between the isolated strain and reference strain (V. cholerae non-O1 ATCC 25872). Most of the antibiotics examined had bacteriostatic action against V. cholerae non-O1 FM-3 while vancomycin, oxacillin, colistin, polymyxin B, and sulfadiazine had no bacteriostatic activity.

  • PDF

Monitoring of Feed-Nutritional Components, Toxic Heavy Metals and Pesticide Residues in Mushroom Substrates According to Bottle Type and Vinyl Bag Type Cultivation (버섯의 봉지재배 및 병재배 시 재배단계별 배지의 사료영양적 성분, 독성중금속 및 잔류농약 모니터링)

  • Kim, Y.I.;Bae, J.S.;Huh, J.W.;Kwak, W.S.
    • Journal of Animal Science and Technology
    • /
    • v.49 no.1
    • /
    • pp.67-78
    • /
    • 2007
  • This study was carried out to monitor feed-nutritional components, toxic heavy metals (Cd, Pb and As) and pesticide residues through three cultivation stages (1st initial culture stage, 2nd mycelial growth stage, and 3rd fruit body-harvested stage) of king oyster mushroom (Pleurotus eryngii) produced by bottle type cultivation and oyster mushroom (Pleurotus osteratus) produced by vinyl bag type cultivation. For both cultivation types, compared with the initial culture, the weight reduction rate in spent mushroom substrates (SMS) after fruit body harvest was 29% for total wet mass, 21~25% for dry and organic matters and 19 ~22% for neutral detergent fiber. Two thirds to 3/4 of organic matter degraded and utilized by mycelia and fruit bodies was originated from fiber, of which the primary source (50~70%) was hemicellulose. The effect of mycelial growth stage on chemical compositional change in culture was little (P>0.05) for bottle type cultivation of king oyster mushroom but considerable (P<0.05) for vinyl type cultivation of oyster mushroom. Culture nutrients uptake by fruit bodies was very active for the bottle type cultivation. Compared with SMS, harvested fruit bodies (mushrooms) contained higher (P<0.05) crude protein, non-fibrous carbohydrate, and crude ash and lower (P<0.05) neutral detergent fiber. Regardless of stages, no culture samples were contaminated with toxic heavy metals and pesticide residues. In conclusion, the increase of fiber (neutral and acid detergent fibers) and indigestible protein contents and the decrease of true protein content in SMS indicated that the feed-nutritional value of SMS was significantly reduced compared with that of the initial culture and they were safe from toxic heavy metals and pesticide residues.

Clninical Features of Rotaviral Gastroenteritis in Neonates (신생아에서 로타바이러스 위장관염의 임상양상에 대한 고찰)

  • Park, Shin-I;Kwon, Hae Oak;Lee, Jun Ho;Jung, Su Jin
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.10
    • /
    • pp.1121-1125
    • /
    • 2005
  • Purpose : Rotavirus is the main cause of infantile diarrheal disease worldwide, especially in patients 3-24 months of age. Infants younger than 3 months of age are relatively protected by transplacental antibody. So the purpose of this study is to evaluate the clinical features and severity of neonatal rotaviral gastroenteritis less than 1 month of age. Methods : A retrospective chart review was established of 62 neonates less than 1 month of age and with a diagnosis of rotaviral gastroenteritis who had been admitted to Pochon CHA University between June 2002 through July 2004. The rotavirus was examined by stool latex agglutination. Results : During 2 years, the total number of admitted patients for rotaviral gastroenteritis was 688 and among these, less than 1 month of age accounted for 9%(62). The occurrence was generally even distribution from January to July($7.14{\pm}1.0$) but since then decreased($2.4{\pm}1.8$). The most common chief complaint was mild fever(46%) when admitted which subsided within 1 hospital day in most patients. 4 patients had seizure and cyanosis with no typical symptoms of rotaviral gastroenteritis. During admission, all the patients had diarrhea. 17% of the patients had leukocytosis and positive C-reactive protein. In one patient, stool occult blood test was positive but there was no necrotizing gastroenteritis evidence. The mean period of hospital day was $5.8{\pm}2.5$ and breast-milk feeding was 62.9%. Conclusion : Neonatal rotaviral gastroenteritis is not a rare disease. Most patients have fever and diarrhea and improve through conservative therapy but a few patients may have severe complications so we must be more cautious about the hygiene for prevention.

In vivo and in vitro Confirmation of Dose Homogeneity in Total Body Irradiation with Thermoluminescent Dosimeter (인체 및 인형 팬톰에서 전신방사선조사시 열형광선량계(TLD)를 이용한 선량분포 균일성 확인)

  • Chie Eui Kyu;Park Suk Won;Kang Wee-Saing;Kim Il Han
    • Radiation Oncology Journal
    • /
    • v.17 no.4
    • /
    • pp.321-328
    • /
    • 1999
  • Purpose : Total body irradiation (TBI) or whole body irradiation is used to acquire immune suppression, to treat malignant lymphoma and leukemia, and as an conditioning regimen for bone marrow transplantation. For these purposes, many methods were developed to obtain homogenous dose distribution. The objective of this study was to analyze and confirm the accuracy and the homogeneity of the treatment setup, the parallel opposed lateral technique, currently used in Seoul National University Hospital. Materials and Metheods : Surface dose data, measured with a thermoluminescent dosimeter, of 8 patients among 10 patients, who were given total body irradiation with the parallel opposed lateral technique between September 1996 to August 1998, at Seoul National University Hospital were analyzed. Surface doses were measured at the head, neck, axilla, thigh, and ankle level. Surface and midline doses were measured with similar set-up and technique in the Humanoid phantom. Results : Measured surface doses relative to prescribed dose for the head, neck, axilla, thight, and ankle leve were $91.3{\pm}7.8,{\;}98.3{\pm}7.5,{\;}95.1{\pm}6.3,{\;}98.3{\pm}5.5$, and $95.3{\pm} 6.3\%$, respectively. The midline doses of the head, neck, axilla, thigh, and ankle level estimated from the surface-to-midline ratios in the Humanoid Phantom were $103.4{\pm}9.0,{\;}107.8{\pm}10.5,{\;}91.1{\pm}6.1,{\pm} 93.8{\pm}4.5,{\;}and{\;}104.5{\pm}9.3\%$, respectively. Measured surface doses and estimated midline doses ranged from $-8.9\%$ to $+7.8\%$. Midline doses at the neck and the axilia level deviated more than $5\%$ from the prescribed doses. The difference of the estimated midline doses at the neck and the axilla level and the actual doses were attributed to the thickness differences between the Humanoid phantom and the patients. Conclusion Distribution of the midline doses as well as the suface doses were measured to be within $-8.7\~{\pm}7.8\%$ range. Actual dose distribution in the patient is expected to be better than the measured dose range mainly attributed to thickness difference between the patient and the Humanoid phantom.

  • PDF

A Study on the Variation of Transmission Factors, Output Factors and Percent Depth Doses by Wedge Filters for 4~10 MV X-Ray Beams (4~10 MV X-선의 쐐기 (wedge) 필터의 투과율과 출력계수, 선축상 선량분포의 변화에 관한 연구)

  • 강위생
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.3-17
    • /
    • 1997
  • Because a wedged beam consists of attenuated primary photons and scattered radiations from wedge, the spectrum of the wedged beam does not coincide with that of an open beam with same geometry. The aims of current report are to get exact information about whether effects of 15-60$^{\circ}$ wedge for 4 -10 MV photon beams should be considered for dose calculation or not, and to suggest a reference condition for measurement of wedge transmission factor. Percent depth dose of both open and wedged fields with angles of 15, 30, 45, 60$^{\circ}$ for beams of 4 MV(Clinac 4/100, Varian), two 6 MV(Clinac 6/100 and Clinac 2100C, Varian), 10 MV(Clinac 2100C, Varian) X-rays were measured to 30cm deep in water using ionization chambers. Hardening factors of photon beams were calculated with measured PDDs. Both field size factors and transmission factors of wedge filters were measured at d$_{max}$ in water. Beam hardening factors of wedged fields of 4 and 6 MV X-ray were larger than 1 for all wedge angles, field sizes and depths deeper than d$_{max}$ Beam hardening factors for wedge angles 15, 30, 45, 60$^{\circ}$ for 10$\times$10cm were respectively 1.010, 1.014, 1.023 and 1.034 for 4MV X-ray, 1.005, 1.008, 1.019, and 1.024 for 6MV X-ray of Clinac 6/100, 1.011, 1.021, 1.032, 1.036 for 6MV X-ray of Clinac 2100C, and 1.008, 1.012, 1.012 and 1.012 for 10MV X-ray. Beam hardening factors of 10MV X-ray were 1 within 1.2% difference for all wedge angles, depths and field sizes. It was made clear that for 6MV X-rays, the beam hardening factor depends on treatment machine. The relationship of the factor and depth was linear. Field size factor at d$_{max}$ was independent of wedge angle except for the field of 15$\times$15cm. and maximum difference of the field size factors for the field size was 1.4% for 4MV X-ray. When the wedge factor is determined, dependence of the factor on field size is negligible at d$_{max}$ but should be considered at deeper depth. Calculating dose distribution or MU, the beam hardening factor should be applied for 4~6MV X-ray beams, but might not be considered for 10MV beam. When wedge transmission factor was determined at d$_{max}$ or in air, field size factors for open field are also applicable to wedged fields, but otherwise, field size factor for each wedge or wedge factor depending on field size should be applied.

  • PDF

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF