• Title/Summary/Keyword: 위변조

Search Result 475, Processing Time 0.024 seconds

Independent Verification Program for High-Dose-Rate Brachytherapy Treatment Plans (고선량률 근접치료계획의 정도보증 프로그램)

  • Han Youngyih;Chu Sung Sil;Huh Seung Jae;Suh Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.3
    • /
    • pp.238-244
    • /
    • 2003
  • Purpose: The Planning of High-Dose-Rate (HDR) brachytherapy treatments are becoming individualized and more dependent on the treatment planning system. Therefore, computer software has been developed to perform independent point dose calculations with the integration of an isodose distribution curve display into the patient anatomy images. Meterials and Methods: As primary input data, the program takes patients'planning data including the source dwell positions, dwell times and the doses at reference points, computed by an HDR treatment planning system (TPS). Dosimetric calculations were peformed in a $10\times12\times10\;Cm^3$ grid space using the Interstitial Collaborative Working Group (ICWG) formalism and an anisotropy table for the HDR Iridium-192 source. The computed doses at the reference points were automatically compared with the relevant results of the TPS. The MR and simulation film images were then imported and the isodose distributions on the axial, sagittal and coronal planes intersecting the point selected by a user were superimposed on the imported images and then displayed. The accuracy of the software was tested in three benchmark plans peformed by Gamma-Med 12i TPS (MDS Nordion, Germany). Nine patients'plans generated by Plato (Nucletron Corporation, The Netherlands) were verified by the developed software. Results: The absolute doses computed by the developed software agreed with the commercial TPS results within an accuracy of $2.8\%$ in the benchmark plans. The isodose distribution plots showed excellent agreements with the exception of the tip legion of the source's longitudinal axis where a slight deviation was observed. In clinical plans, the secondary dose calculations had, on average, about a $3.4\%$ deviation from the TPS plans. Conclusion: The accurate validation of complicate treatment plans is possible with the developed software and the qualify of the HDR treatment plan can be improved with the isodose display integrated into the patient anatomy information.

Effects of Nodus Nelumbinis Rhizomatis Extracts on Sociopsychological Stress in Mice (연근(蓮根) 추출물이 생쥐의 사회.심리적 스트레스에 미치는 영향)

  • Kim, Su-Yeon;Kim, Eun-Jeong;Lee, Dong-Won;Won, Ho-Young
    • Journal of Oriental Neuropsychiatry
    • /
    • v.15 no.2
    • /
    • pp.149-158
    • /
    • 2004
  • 만성적이거나 반복적인 스트레스는 우울중이나 심신병 등의 발병 기전과 밀접한 관련이 있다. 전기적 자극(electric foot shock), 한랭 자극, 속박(immobilization), 투쟁(fighting), 에테르 노출 등과 같은 심한 스트레스 자극이 뇌 조직의 시상 및 시상하부, 편도체 등에서의 노르아드레날린(noradrenalin) 방출을 유의 하게 감소시키는 동시에 혈청 corticosterone을 증가시키는 것으로 알려져 있다. 한의학에서는 스트레스 인자에 대한 신체반응을 기(氣)의 변화로 인식하고 있고, 이러한 자극요인들은 신체에 대하여 병적 요인을 제공하여 제반 질환을 야기한다. 또한 질병 발생에 대한 근거로 정기(正氣)와 사기(邪氣)의 상호 관계 위주로 인식하는데, 내부의 기(氣)의 변조(變調)는 질병의 발생을 야기하는 기초가 된다. 실험에 사용된 연근(蓮根)은 연꽃과에 속한 수생초본인 연꽃의 뿌리부분으로 우(藕) 또는 우절(藕節)이라는 명칭으로 불리기도 한다. 성미(性味)는 감(甘) 삽(澁) 평(平) 무독(無毒)하고 폐(肺) 위(胃) 간경(肝經)으로 들어가며 수렴지혈(收斂止血) 화어(化瘀)의 효능이 있어 토혈(吐血) 객혈(喀血) 뇨혈(尿血) 편혈(便血) 등의 각종 출혈 증상에 사용되어져 왔다. 최근 연꽃의 부위별 추출물이 흰쥐의 지질 과산화 생성을 효과적으로 억제하는 것으로 보고되고 있어 연근(蓮根)에 대한 다양한 약리 효능의 검색이 필요할 것으로 생각되며 연꽃의 씨앗인 연자육(蓮子肉)이 양심안신(養心安神)의 효능이 있어 스트레스성 질환에 많이 응용되고 있는 것에 착안하여 본 연구를 착수하였다. 실험 동물은 ICR계 마우스를 이용하였으며, 사회 심리적 스트레스는 옆쪽 cage에서 다른 마우스의 신체에 가해지는 전기 충격을 하루 1시간 동안 지켜보게 하는 것으로 유발하였으며 이 상태에서 약물을 투여한 그룹을 실험군, 그렇지 않은 그룹을 대조군으로 하였다. 정상군은 아무런 자극 없이 하루 1시간 동안 일정 공간에 가두어 두는 것으로 하였다. 실험 결과 사회 심리적 스트레스를 받은 경우에 아무런 처치를 하지 않은 대조군에 비해 연근 추출물을 100mg/kg/day 용량으로 5 일간 투여한 실험군에서 혈청 중 corticosterone 함량이 유의하게 감소하였으므로 매우 효과적으로 스트레스를 해소하였음을 알 수 있다. 뇌세포 중에서 신경전달물질로 분비되는 노르아드레날린의 분비량은 전반적으로 증가되는 경향을 나타내었으나 유의성은 없었다. 신체적 또는 사회 심리적 스트레스가 간 조직 내 지질의 과산화를 유발하는 것으로 나타났으며 연근 추출물이 이 결과에는 영향을 주지 못하였다. 사회 심리적 스트레스로 인하여 간 조직 내 지질과산화 정도가 증가하였으므로 혈청 내 ALT 함량도 따라 증가할 것으로 추정되었으며 이에 대한 연근 추출물 경구 투여가 간 조직을 보호할 수 있는지를 확인하기 위해 분리한 혈청으로부터 ALT 함량을 측정한 결과 대조군에 비하여 유의한 감소를 나타내었다. 또한 연근 추출물이 혈청 내 지질 과산화물의 생성을 억제할 수 있다면 질병의 예방과 치료에 효과적일 것으로 추정할 수 있으므로 그 생성량을 측정하여 보았으나 대조군과의 차이가 나타나지 않았다. 이상의 결과들을 종합하여 보면 스트레스가 부하된 5일 동안 연근(蓮根) 추출물을 함께 투여한 결과 혈청 corticosterone 함량을 유의하게 감소시켰고 뇌 조직내 noradrenaline 함량을 증가시키는 경향을 나타내어 스트레스 해소에 도움이 될 수 있음을 시사하였다. 또한 혈청 내 ALT 함량을 유의하게 감소시켜 스트레스로 인해 발생하는 간 기능의 손상도 어느 정도 억제시키는 것을 확인할 수 있었는데 앞으로 연근(蓮根)의 이러한 작용에 대한 보다 자세한 연구들이 필요한 것으로 생각된다.

  • PDF

Small Bowel Sparing Effect of Small Bowel Displacement System in 3D-CRT and IMRT for Cervix Cancer (자궁경부암의 3D-CRT와 IMRT시 소장전위장치의 소장 선량에 대한 영향)

  • Kang, Min-Kyu;Huh, Seung-Jae;Han, Young-Yih;Park, Won;Ju, Sang-Gyu;Kim, Kyoung-Ju;Lee, Jeung-Eun;Park, Young-Je;Nam, Hee-Rim;Lim, Do-Hoon;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.22 no.2
    • /
    • pp.130-137
    • /
    • 2004
  • Purpose : In radiotherapy for cervix cancer, both 3-dimensioal radiotherapy (3D-CRT) and intensity-modulated radiation therapy (IMRT) could reduce the dose to the small bowel (SB), while the small bowel displacement system (SBDS) could reduce the SB volume in the pelvic cavity. To evaluate the effect of the SBDS on the dose to the SB in 3D-CRT and IMRT plans, 3D-CRT and IMRT plans, with or without SBDS, were compared. Materials and Methods : Ten consecutive uterine cervix cancer patients, receiving curative radiotherapy, were accrued. Ten pairs of computerized tomography (CT) scans were obtained in the prone position, with or without SBDS, which consisted of a Styrofoam compression device and an individualized custom-made abdominal immobilization device. Both 3D-CRT, using the 4-field box technique, and IMRT plans, with 7 portals of 15 MV X-ray, were generated for each CT image, and proscribed 50 Gy (25 fractions) to the isocenter. For the SB, the volume change due to the SBDS and the DVHs of the four different plans were analyzed using palled t-tests. Results : The SBDS significantly reduced the mean SB volume from 522 to 262 cm$^{3}$ (49.8$\%$ reduction). The SB volumes that received a dose of 10$\~$50 Gy were significantly reduced in 3D-CRT (65$\~$80$\%$ reduction) and IMRT plans (54$\~$67$\%$ reduction) using the SBDS. When the SB volumes that received 20$\~$50 Gy were compared between the 3D-CRT and IMRT plans, those of the IMRT without the SBDS were significantly less, by 6$\~$7$\%$, than those for the 3D-CRT without the SBDS, but the volume difference was less than 1$\%$ when using the SBDS. Conclusion : The SBDS reduced the radiation dose to the SB in both the 3D-CRT and IMRT plans, so could reduce the radiation injury of the SB.

Evaluating efficiency of Vertical MLC VMAT plan for naso-pharyngeal carcinoma (비인두암 Vertical MLC VMAT plan 유용성 평가)

  • Chae, Seung Hoon;Son, Sang Jun;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.127-135
    • /
    • 2021
  • Purpose : The purpose of the study is to evaluate the efficiency of Vertical MLC VMAT plan(VMV plan) Using 273° and 350° collimator angle compare to Complemental MLC VMAT plan(CMV plan) using 20° and 340° collimator angle for nasopharyngeal carcinoma. Materials & Methods : Thirty patients treated for nasopharyngeal carcinoma with the VMAT technique were retrospectively selected. Those cases were planned by Eclipse, PO and AcurosXB Algorithm with two 6MV 360° arcs and Each arc has 273° and 350° of collimator angle. The Complemental MLC VMAT plans are based on existing treatment plans. Those plans have the same parameters of existing treatment plans but collimator angle. For dosimetric evaluation, the dose-volumetric(DV) parameters of the planning target volume (PTV) and organs at risk (OARs) were calculated for all VMAT plans. MCSv(Modulation complexity score of VMAT), MU and treatment time were also compared. In addition, Pearson's correlation analysis was performed to confirm whether there was a correlation between the difference in the MCSv and the difference in each evaluation index of the two treatment plans. Result : In the case of PTV evaluation index, the CI of PTV_67.5 was improved by 3.76% in the VMV Plan, then for OAR, the dose reduction effect of the spinal cord (-14.05%) and brain stem (-9.34%) was remarkable. In addition, the parotid glands (left parotid : -5.38%, right : -5.97%) and visual organs (left optic nerve: -4.88%, right optic nerve: -5.80%, optic chiasm : -6.12%, left lens: -6.12%, right lens: -5.26%), auditory organs (left: -11.74%, right: -12.31%) and thyroid gland (-2.02%) were also confirmed. The difference in MCSv of the two treatment plans showed a significant negative (-) correlation with the difference in CI (r=-0.55) of PTV_54 and the difference in CI (r=-0.43) of PTV_48. Spinal cord (r=0.40), brain stem (r=0.34), and both salivary glands (left: r=0.36, right: r=0.37) showed a positive (+) correlation. (For all the values, p<.05) Conclusion : Compared to the CMV plan, the VMV plan is considered to be helpful in improving the quality of the treatment plan by allowing the MLC to be modulated more efficiently

Development of Adjustable Head holder Couch in H&N Cancer Radiation Therapy (두경부암 방사선 치료 시 Set-Up 조정 Head Holder 장치의 개발)

  • Shim, JaeGoo;Song, KiWon;Kim, JinMan;Park, MyoungHwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.43-50
    • /
    • 2014
  • In case of all patients who receive radiation therapy, a treatment plan is established and all steps of treatment are planned in the same geometrical condition. In case of head and neck cancer patients who undergo simulated treatment through computed tomography (CT), patients are fixed onto a table for planning, but laid on the top of the treatment table in the radiation therapy room. This study excogitated and fabricated an adjustable holder for head and neck cancer patients to fix patient's position and geometrical discrepancies when performing radiation therapy on head and neck cancer patients, and compared the error before and after adjusting the position of patients due to difference in weight to evaluate the correlation between patients' weight and range of error. Computed tomography system(High Advantage, GE, USA) is used for phantom to maintain the supine position to acquire the images of the therapy site for IMRT. IMRT 4MV X-rays was used by applying the LINAC(21EX, Varian, U.S.A). Treatment planning system (Pinnacle, ver. 9.1h, Philips, Madison, USA) was used. The setup accuracy was compared with each measurement was repeated five times for each weight (0, 15, and 30Kg) and CBCT was performed 30 times to find the mean and standard deviation of errors before and after the adjustment of each weight. SPSS ver.19.0(SPSS Inc., Chicago, IL,USA) statistics program was used to perform the Wilcoxon Rank test for significance evaluation and the Spearman analysis was used as the tool to analyze the significance evaluation of the correlation of weight. As a result of measuring the error values from CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.4{\pm}0.8mm$, $0.8{\pm}0.4mm$, 0 for 0Kg before the adjustment. In 15Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.2{\pm}0.8mm$, $1.2{\pm}0.4mm$, $2.0{\pm}0.4mm$. After adjusting position was X,Y,Z axis was $0.2{\pm}0.4mm$, $0.4{\pm}0.5mm$, $0.4{\pm}0.5mm$. In 30Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.8{\pm}0.4mm$, $2.4{\pm}0.5mm$, $4.4{\pm}0.8mm$. After adjusting position was X,Y,Z axis was $0.6{\pm}0.5mm$, $1.0{\pm}0mm$, $0.6{\pm}0.5mm$. When the holder for the head and neck cancer was used to adjust the ab.0ove error value, the error values from CBCT were $0.2{\pm}0.8mm$ for the X axis, $0.40{\pm}0.54mm$ for Y axis, and 0 for Z axis. As a result of statistically analyzing each value before and after the adjustment the value was significant with p<0.034 at the Z axis with 15Kg of weight and with p<0.038 and p<0.041 at the Y and Z axes respectively with 30Kg of weight. There was a significant difference with p<0.008 when the analysis was performed through Kruscal-Wallis in terms of the difference in the adjusted values of the three weight groups. As it could reduce the errors, patients' reproduction could be improved for more precise and accurate radiation therapy. Development of an adjustable device for head and neck cancer patients is significant because it improves the reproduction of existing equipment by reducing the errors in patients' position.