• Title/Summary/Keyword: 웨어러블기기

Search Result 236, Processing Time 0.025 seconds

Design of a Low Noise 6-Axis Inertial Sensor IC for Mobile Devices (모바일용 저잡음 6축 관성센서 IC의 설계)

  • Kim, Chang Hyun;Chung, Jong-Moon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.2
    • /
    • pp.397-407
    • /
    • 2015
  • In this paper, we designed 1 chip IC for 3-axis gyroscope and 3-axis accelerometer used for various IoT/M2M mobile devices such as smartphone, wearable device and etc. We especially focused on analysis of gyroscope noise and proposed new architecture for removing various noise generated by gyroscope MEMS and IC. Gyroscope, accelerometer and geo-magnetic sensors are usually used to detect user motion or to estimate moving distance, direction and relative position. It is very important element to designing a low noise IC because very small amount of noise may be accumulated and affect the estimated position or direction. We made a mathematical model of a gyroscope sensor, analyzed the frequency characteristics of MEMS and circuit, designed a low noise, compact and low power 1 chip 6-axis inertial sensor IC including 3-axis gyroscope and 3-axis accelerometer. As a result, designed IC has 0.01dps/${\sqrt{Hz}}$ of gyroscope sensor noise density.

Reduced Graphene Oxide / Polyaniline Composite Material for Supercapacitor Electrode (환원된 그래핀 옥사이드/폴리아닐린 복합재료 기반의 슈퍼커패시터용 전극 제조)

  • Jeong, Hyeon Taek;Kim, Se Hyun;Ahn, Won Jun;Choi, Jae Yong;Park, Hyeon Young;Kim, Chang Hyun;Kim, Yong Ryeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.1088-1095
    • /
    • 2018
  • In this study, reduced graphene oxide/polyaniline composite was fabricated tomaximize their advantages with electrochemical performances and use as a electrodematerial for supercapcaitor. Polyaniline as an electrode material was synthesized bychemical polymerization of aniline monomer and reduced graphene oxide wasintroduced to prepare composite with polyaniline without any pre-treatment. Thereduced graphene oxide, polyaniline and their composite electrodes were fabricatedon gold coated PET(polyethylene terephthalate) substrate through spray coatingmethod which can also apply to industrial scale. we have also prepared reducedgraphene oxide and polyaniline single material electrode to compare theirelectrochemical properties with reduced graphene oxide/polyaniline composite electrode. We have analyzed and compared electrochemical properties of eachelectrodes by using cyclic voltammetry(CV), galvanostaticcharge-discharge(GCD) and electrochemical impedancespectroscopy(EIS) at same condition. As a result, reduced graphene oxide /polyaniline composite electrode showed higher capacitance value more thanpolyaniline and reduced graphene oxide electrode, respectively. Internal resistanceof reduce graphene oxide/polyaniline composite electrode was 24% and 58% lessthan polaniline and reduced graphene oxide electrode respectively. These resultsconsidered that reduced graphene oxide/polyaniline composite electrode has potential ability and enable to apply flexible energy storage and wearable devices.

Factors Affecting Consumers' Experience of Using Smart Healthcare Focusing on Health Literacy and Personal Characteristics (건강정보이해능력과 개인의 특성이 스마트 헬스케어 이용 경험에 미치는 요인 분석)

  • Kim, Ga Eun;Park, Hyun Jun
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.4
    • /
    • pp.41-53
    • /
    • 2019
  • As the paradigm of healthcare shifts from the center of treatment to the center of prevention, products and services related to disease prevention are emerging at domestic and abroad. The government considers the smart healthcare industry as a solution to healthcare problems such as an increase in the number of chronic illnesses and an increase in the burden of medical expenses. The purpose of this study is to explore the factors affecting the use of smart healthcare products and services focusing on Health Literacy and health related personal characteristics and to provide policy implications. The subjects of the questionnaire are 1,027 adults over 20 in the nation, and conducted an online survey. In addition, the factors were analyzed by decision tree method. As a result, most of the respondents(76.9%) did not have experience using Smart Healthcare products and services. However, in the Health Literacy question, there was a difference in use experience depending on the degree of difficulty in using the mass media information. Other factors were the degree of intention to use new technology, the understanding of counseling about family members and friends, and health checkups. In order to enable self-healthcare through smart healthcare products and services, the ability of consumers to explore and utilize health information from the mass media should be improved. In addition, government and enterprise efforts are needed to achieve this.

Laser Transmission Welding of Flexible Substrates and Evaluation of the Mechanical Properties (플렉서블 기판의 레이저 투과 용접 및 기계적 특성 평가)

  • Ko, Myeong-Jun;Sohn, Minjeong;Kim, Min-Su;Na, Jeehoo;Ju, Byeong-Kwon;Park, Young-Bae;Lee, Tae-Ik
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.2
    • /
    • pp.113-119
    • /
    • 2022
  • In order to improve the mechanical reliability of next-generation electronic devices including flexible, wearable devices, a high level of mechanical reliability is required at various flexible joints. Organic adhesive materials such as epoxy for bonding existing polymer substrates inevitably have an increase in the thickness of the joint and involve problems of thermodynamic damage due to repeated deformation and high temperature hardening. Therefore, it is required to develop a low-temperature bonding process to minimize the thickness of the joint and prevent thermal damage for flexible bonding. This study developed flexible laser transmission welding (f-LTW) that allows bonding of flexible substrates with flexibility, robustness, and low thermal damage. Carbon nanotube (CNT) is thin-film coated on a flexible substrate to reduce the thickness of the joint, and a local melt bonding process on the surface of a polymer substrate by heating a CNT dispersion beam laser has been developed. The laser process conditions were constructed to minimize the thermal damage of the substrate and the mechanism of forming a CNT junction with the polymer substrate. In addition, lap shear adhesion test, peel test, and repeated bending experiment were conducted to evaluate the strength and flexibility of the flexible bonding joint.

Study on Structural Changes and Electromagnetic Interference Shielding Properties of Ti-based MXene Materials by Heat Treatment (열처리에 의한 Ti 기반 MXene 소재의 구조 변화와 전자파 간섭 차폐 특성에 관한 연구)

  • Han Xue;Ji Soo Kyoung;Yun Sung Woo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.3
    • /
    • pp.111-118
    • /
    • 2023
  • MXene, a two-dimensional transition metal carbide or nitride, has recently attracted much attention as a lightweight and flexible electromagnetic shielding material due to its high electrical conductivity, good mechanical strength and thermal stability. In particular, the Ti-based MXene, Ti3C2Tx and Ti2CTx are reported to have the best electrical conductivity and electromagnetic shielding properties in the vast MXene family. Therefore, in this study, Ti3C2Tx and Ti2CTx films were prepared by vacuum filtration using Ti3C2Tx and Ti2CTx dispersions synthesized by interlayer metal etching and centrifugation of Ti3AlC2 and Ti2AlC. The electrical conductivity and electromagnetic shielding efficiency of the films were measured after heat treatment at high temperature. Then, X-ray diffraction and photoelectron spectroscopy were performed to analyze the structural changes of Ti3C2Tx and Ti2CTx films after heat treatment and their effects on electromagnetic shielding. Based on the results of this study, we propose an optimal structure for an ultra-thin, lightweight, and high performance MXene-based electromagnetic shielding film for future applications in small and wearable electronics.

Development of Electret to Improve Output and Stability of Triboelectric Nanogenerator (마찰대전 나노발전기의 출력 및 안정성 향상을 위한 일렉트렛 개발)

  • Kam, Dongik;Jang, Sunmin;Yun, Yeongcheol;Bae, Hongeun;Lee, Youngjin;Ra, Yoonsang;Cho, Sumin;Seo, Kyoung Duck;Cha, Kyoung Je;Choi, Dongwhi
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.93-99
    • /
    • 2022
  • With the rapid development of ultra-small and wearable device technology, continuous electricity supply without spatiotemporal limitations for driving electronic devices is required. Accordingly, Triboelectric nanogenerator (TENG), which utilizes static electricity generated by the contact and separation of two different materials, is being used as a means of effectively harvesting various types of energy dispersed without complex processes and designs due to its simple principle. However, to apply the TENG to real life, it is necessary to increase the electrical output. In addition, stable generation of electrical output, as well as increase in electrical output, is a task to be solved for the commercialization of TENG. In this study, we proposed a method to not only improve the output of TENG but also to stably represent the improved output. This was solved by using the contact layer, which is one of the components of TENG, as an electret for improved output and stability. The utilized electret was manufactured by sequentially performing corona charging-thermal annealing-corona charging on the Fluorinated ethylene propylene (FEP) film. Electric charges artificially injected due to corona charging enter a deep trap through the thermal annealing, so an electret that minimizes charge escape was fabricated and used in TENG. The output performance of the manufactured electret was verified by measuring the voltage output of the TENG in vertical contact separation mode, and the electret treated to the corona charging showed an output voltage 12 times higher than that of the pristine FEP film. The time and humidity stability of the electret was confirmed by measuring the output voltage of the TENG after exposing the electret to a general external environment and extreme humidity environment. In addition, it was shown that it can be applied to real-life by operating the LED by applying an electret to the clap-TENG with the motif of clap.