• Title/Summary/Keyword: 월성3호기

Search Result 56, Processing Time 0.019 seconds

Review of Emergency Procedures for CANDU Reactors (캔두형 원자력 발전소 비상절차서 검토)

  • Kim, S.R.;Kwon, J.S.;Cho, J.H.;Park, S.H.;Nam, S.K.
    • Nuclear Engineering and Technology
    • /
    • v.27 no.4
    • /
    • pp.571-581
    • /
    • 1995
  • The generation, verification and validation of Emergency Procedures for Nuclear Power Plant is a difficult and complex process. Atomic Energy Control Board(AECB) requires that emergency procedure and plan be produced before obtaining the Operating License, that is, detailed plans and procedures to handle emergency situations for both on-site actions and off-site actions be developed. In this report Emergency Operating Procedures Standard for Canadian Nuclear Utilities which makes reference to U. S. practices and the current direction of emergency procedures for CAN-DU reactors are reviewed and compared based on scope(events covered), methodology (event-oriented or symptom-oriented or hybrid) and format(method of presentation) preponderantly, and an attempt is made to integrate these procedures and as a result the recommended strategy for Wolsong unit 2, 3, & 4 is presented as event-specific procedures, generic procedures(when event is not diagnosed) and whose format is combination of logic diagram and text.

  • PDF

Assessment of the Internal Pressure Fragility of the CANDU Type Containment Buildings using Nonlinear Finite Element Analysis (비선형 유한요소해석을 이용한 CANDU형 격납건물의 내압취약도 평가)

  • Hahm, Dae-Gi;Choi, In-Kil;Lee, Hong-Pyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.4
    • /
    • pp.445-452
    • /
    • 2010
  • In this paper an assessment of the internal pressure fragility of the CANDU type containment buildings is performed. The uncertainties of the performance of the containment buildings, material properties and tendon characteristics are referred from the in-service reports of Wolsung Unit 1. The containment buildings are modeled as a three-dimensional finite elements with considering the major opening and penetrations. A new method to evaluate the probabilistic fragility of the massive structural system is developed. The fragility curves of the target containment building are presented with repect to the failure modes and reliability levels. The center of wall is reveled as the most weak structural component of the containment building in the sense of the rupture and catastrophic rupture failure modes.

Parametric Effects of Ambient Conditions on Thermal Safety of Wolsong (CANDU) Unit 1 Spent Fuel Dry Storage Canister (월성1호기 사용후 핵연료 건식저장 캐니스터의 열적 안전성에 미치는 대기 조건 인자의 영향)

  • Park, Jong-Woon;Chun, Moon-Hyun;Shon, Soon-Hwan;Song, Myung-Jae
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.166-177
    • /
    • 1993
  • A simplified thermal analysis method to evaluate the maximum temperature of the CANDU 37-element fuel bundle within a fuel basket in a given spent fuel dry storage canister has been presented along with the results of sample analyses performed to examine the parametric effects of the ambient conditions on the maximum fuel temperature within a canister. To solve the multi-dimensional heat transfer problem of the complex geometry of rod bundles within a canister where three modes of heat transfer are superimposed, the CANDU spent fuel bundles stored in the dry storage canister are first replaced by equivalent concentric fuel cylinders. The simplified axi-symmetric two-dimensional multi-mode heat transfer problem of the equivalent fuel cylinders is then analyzed with an existing computer code, HEATING5, using additional input data and heat transfer correlations. A comparison between the predicted temperature profile and the mock-up test results shows that the agreement is quite satisfactory.

  • PDF

An Assessment on the Contribution of $^3$He to the Tritium Generation in the CANDU PHWR (가압중수로에서 헬륨-3이 삼중수소의 생성에 미치는 영향평가)

  • Kwak, Sung-Woo;Chung, Bum-Jin
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.2
    • /
    • pp.119-125
    • /
    • 1997
  • PHWR achieves high neutron economy by adopting heavy water as its moderator and coolant. On the other hand it permits much tritium generation, compared to LWR, due to the neutron capture reaction of deuterium in heavy water. Meanwhile in the reactor core, $^3He formed as the result of-decay of tritium, captures a thermal neutron and transforms to tritium again. The existing calculation models on tritium generation in PHWR neglect the contribution of $^3He$ in both moderator and coolant due to its relatively low solubility. However the neutron capture cross-section of $^3He$ is almost $1.6{\times}10^7$ times as large as that of deuterium. That means that the dissolved amount of 0.03 ppm of $^3He$ in heavy water is enough to generate the same amount of tritium as that generated by the deuterium of total heavy water in the system. This study dealt with the contribution of $^3He$ to tritium generation. As a sample case, the contribution of $^3He$ to the tritium generation in Wolsong #1 was evaluated and compared to the measured values. According to the result of this study, it is concluded that $^3He$ in coolant contributes very much to the tritium generation but that in moderator shows negligible effects due to the low solubility and $^4He$ cover gas. At the beginning of the plant operation, the contribution of $^3He$ is slightly greater than the measured value but agrees well with the measured as the operating time increases.

  • PDF

Radiation Exposure on Radiation Workers of Nuclear Power Plants in Korea : 2009-2013 (국내 원전 종사자의 방사선량 : 2009-2013)

  • Lim, Young-khi
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.162-167
    • /
    • 2015
  • Although the perfomance indicators of the nuclear power plants in Korea show optimal, it requires detailed analysis and discussion centered on the radiation dose. As analysis methods, analysis on the radiation dose of nuclear power plants over the past five years was assessed by comparing the relevant radiation dose of radiation workers and per capita average annual radiation dose of the world's major nuclear power stations was also analyzed. The radiation workers over the annual radiation dose limit of 50 mSv were not. The contrast ratio of the radiation exposure according to the reactor type was the normal operation of PHWR was 6.2% higher than those of the PWR. This shows the radiation work of PHWR during normal driving operation is much more than those of PWR. According to the Performance Indicators of the World Association of Nuclear Operator, the annual radiation dose per unit in 2013 showed 527 man-mSv of Korea is the best country among the major nuclear power generating states, the world average was 725 man-mSv. The annual per capita radiation dose is about 80% less than 1 mSv of the public dose limit and also the average per capita dose showed a very low level as 0.82 mSv. Workers in related organizations showed 1.07 mSv, the non-destructive inspection agency workers showed 3.87 mSv. The remarkable results were due to radiation reduced program such as development of radiation shielding and radiation protection. In conclusion, the radiation exposured dose of nuclear power plants workers in Korea showed a trend which is ideally reduced. But more are expected to be difficul and the psychological insecurity against the operation of the nuclear power plants is existed to the residents near the nuclear power plants. So the radiation dose reduction policy and radiation dose follow up study of nuclear power plants will be continously excuted.

Development and Application of the Visual Test Instrument for Spent CANDU Fuel Bundle Serial Number Identification (CANDU형 사용후 핵연료 다발 일련번호 확인을 위한 육안검사 장치 개발 및 적용)

  • Na, Won-Woo;Lee, Young-Gil;Yoon, Wan-Ki;Kwack, Eun-Ho;Park, Seung-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.2
    • /
    • pp.93-99
    • /
    • 1999
  • SCAI(spent CANDU fuel bundle serial number identifier) was developed to read serial numbers of spent fuel bundles in the spent fuel storage. For the purpose of effectively identifying the serial number of fuel bundle. SCAI was composed of underwater camera & light part. guiding & supporting part and control & monitor part. So it is easy to assemble and disassemble, and operate. It was tested to read serial numbers of spent fuel bundles loaded in basket during the recent spent fuel transfer campaign at Wolsong Unit 1. And it was also applied to read serial numbers of spent fuel bundles discharging from the initial core at Wolsong Unit 3 by slight change of camera and light. Inspectors could easily operate SCAI after several practices in the storage pond, which was a user friendly. And SCAI provided clear and immediate picture for identification of serial numbers of spent fuel bundles. It was interally evaluated that SCAI greatly contributed to cut inspection efforts for national and international safeguards at Wolsong power plant.

  • PDF