• Title/Summary/Keyword: 원형 튜브

Search Result 73, Processing Time 0.022 seconds

Experimental Study on the Air-Side Heat Transfer Characteristics of a Spirally-Coiled Circular Fin-Tube Heat Exchanger According to Geometric Parameters (형상변수에 따른 나선형 원형핀-튜브 열교환기의 공기측 열전달 특성에 관한 실험적 연구)

  • Kang, Tae-Hyung;Lee, Moo-Yeon;Kim, Yong-Chan;Yun, Sung-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.5
    • /
    • pp.515-522
    • /
    • 2010
  • The objective of this study is to investigate the air-side heat transfer characteristics of a spirally-coiled circular fin-tube heat exchanger for various geometric parameters under non-frosting conditions. The heat transfer characteristics of the heat exchanger were analyzed with respect to heat exchanger geometries, and then, the characteristics were compared with those of rectangular-plate fin-tube heat exchangers with discrete fins. The heat transfer coefficient increased with a decrease in the number of tube rows and an increase in the fin pitch. The optimum length of the L-foot was 2.7 mm. In addition, the heat transfer rate increased with a decrease in the tube pitch and the tube thickness. The heat transfer coefficient of the spirally-coiled circular fin-tube heat exchanger was 24.3% higher than that of the rectangular-plate fin-tube heat exchanger.

비축대칭 소재에서 내부가 원형인 튜브의후방압출 해석

  • 양동열;배원병;김동권
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.04a
    • /
    • pp.74-78
    • /
    • 1992
  • 외부가 비축대칭인 튜브의 수방압출은 자동차와 항공기등의 복잡한 부품을 만드는데 많이 사용된다. 이런 후방압출 제품의 변형 상태는 저자들의 논문에서 이미 밝힌 바와 같이 복잡하다. 그래서, 외부가 비출대칭인 튜브형상의 후방압출은 근래에 와서 연구되었다. 본 연구에서는 저자들의 논문 에서 제시된 동적가용속도장을 수정하여 비축대칭인 소재에서 내부가 원형인 튜브의 후방압출의 최종 단계를 해석하 고자 한다. 해석의 적용예로서는 정다각형 소재와 모서리가 둥근 직사각형(rounded rectangle)소재를 택하였다 제시된 속도장으로부터 단면 감소율과 형상비(aspect ratio)에 대하여 압출 하중과 압출된 소재의 평균 높이가 결정된다. 이론적인 결과와 비교하기 위하여 퓰림처리된 AIST-2024 알루미늄 소재로 실험하였다.

원형실린더의 벽면효과에 관한 연구

  • Bae, Bong-Gap;O, U-Jun;Choe, Min-Seon;Jo, Dae-Hwan;Lee, -GyeongU
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2009.10a
    • /
    • pp.134-135
    • /
    • 2009
  • 선박에서 주로 채택되는 열교환기는 쉘튜브형과 판형열교환기로 분류된다. 이 연구에서는 소형쉘튜브형 열교환기의 설계에서 중요한 요소인 냉각튜브와 벽면과의 간격에 따른 유동특성을 입자영상유속계를 이용하여 계측하였다. 연구 결과 벽면과의 거리변화에 따른 임계간격비는 0.25전후로 추정되었으며 벽면효과에 따른 정량적 데이터를 확보하였다.

  • PDF

A Study on the energy absorption characteristics of GFRP circular tubes fabricated by the filament winding method (필라멘트 와인딩 공법 GFRP 원형 튜브의 에너지 흡수특성에 관한 연구)

  • Kim, Geo-Young;Koo, Jeong-Seo
    • Composites Research
    • /
    • v.22 no.4
    • /
    • pp.1-12
    • /
    • 2009
  • In this paper, quasi-static crushing tests of composite circular tubes under axial compression load are conducted to investigate the energy absorption characteristics. Circular tubes used for this experiment are glass/epoxy (GFRP) composite tubes which are fabricated by the filament winding method. One edge of the composite tube is chamfered to reduce the initial peak load and to prevent catastrophic failure during crushing process. Energy absorption characteristics vary significantly according to the constituent materials, fabrication conditions, tube geometry and test condition. In tube geometry, according as inner diameter increase, unstable crush mode is caused by local buckling of delamination, but control of the fiber orientation should help composite tubes get stable crush mode.

Capacity Evaluation of Compressive Member Confined by Carbon Sheet Tube (카본시트튜브로 구속된 압축재의 성능평가)

  • Lee, Kyoung-Hun;Kim, Hee-Cheul;Hong, Won-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.3
    • /
    • pp.152-159
    • /
    • 2006
  • An experimental research has been performed to investigate capacity of CFCST(Concrete Filled Carbon Sheet Tube) columns because column member is one of the most important structural members. Generally, two shapes of column sections, rectangular and circular shapes, are designed but the circular shape which has constant curvature was chosen for this study. Total 17 column specimens confined by carbon sheet tube were tested using 10,000kN universal test machine(UTM).

Analytical Study on the Heat Transfer Characteristics of a Spirally Coiled Circular Fin-Tube Evaporator Operated Under Non-Frosting Conditions (무착상 조건에서 나선형 원형핀-튜브 증발기의 열전달 성능에 관한 해석적 연구)

  • Lee, Moo-Yeon;Kang, Tae-Hyung;Kim, Yong-Chan;Park, Jae-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.105-112
    • /
    • 2011
  • The objective of this study is to predict the heat-transfer performance of a spirally coiled circular fin-tube evaporator in which either R134a or R600a was used; this heat-transfer performance was predicted by varying the mass flow rate, inlet air temperature, air flow rate, and tube thickness. Mean deviation for the analytical model from the measured data was ${\pm}8.3%$. Simulation results revealed that at a given mass flow rate, the heat-transfer rate of the evaporator using R600a was higher than that usingR134a because the enthalpy of the former is higher than that of the latter at the given conditions. The heat-transfer rate of both refrigerants increased with an increase in the air flow rate and inlet air temperature but decreased with an increase in the tube thickness.

Effects of Reinforced Fibers on Energy Absorption Characteristics under Quasi-static Compressive Loading of Composite Circular Tubes (강화섬유에 따른 준정적 하중하에서 복합소재 원형튜브의 에너지 흡수특성 평가 연구)

  • Kim, Jung-Seok;Yoon, Huk-Jin;Lee, Ho-Sun;Choi, Kyung-Hoon
    • Composites Research
    • /
    • v.22 no.6
    • /
    • pp.32-38
    • /
    • 2009
  • In this study, the energy absorption capabilities and failure modes of four different kinds of circular tubes made of carbon, Kevlar and carbon-Kevlar hybrid composites with epoxy resin have been evaluated. In order to achieve these goals, these tubes were fabricated with unidirectional prepregs and compressive tests were conducted for the tubes under 10mm/min loading speed. From the test results, carbon/epoxy tubes were collapsed by brittle fracturing mode and showed the best energy absorption capabilities, while Kevlar/epoxy tubes were crushed by local buckling mode and worst. The hybrid [$90_C/0_K$] tubes were failed in a local bucking mode and showed good post crushing integrity, whereas [$90_K/0_C$] tubes were failed in a lamina bending mode and bad post crushing integrity.

Flexural Capacity and Non-Linear Characteristic Evaluation of Circular Column Confined by Carbon Sheet Tube (카본시트튜브로 구속된 원형기둥의 휨내력 및 비선형 특성에 대한 연구)

  • Lee, Kyoung Hun;Yoo, Youn Jong;Kim, Hee Cheul;Hong, Won Kee;Lee, Young Hak
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.143-150
    • /
    • 2007
  • Six full scale column specimens have been tested under the constant axial and cyclic lateral load. An equivalent stress block parameter was used to estimate flexural capacity of columns confined by carbon sheet tube. Through the non-linear regression analysis, behaviors of CFCST(Concrete Filled Carbon Sheet Tube) columns under the cyclic lateral load were estimated and compared with test results.

A Study on the Burst Pressure of Circular Tubes (원형튜브의 파열압력에 관한 연구)

  • 이영신;강문중;조원만
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.6
    • /
    • pp.1056-1063
    • /
    • 1992
  • Burst pressure of right circular tube is predicted using analytic method, and asymptotic instability pressure of circular tube with roundness defect is found using FEM. Burst tests of nearly right circular tube specimens are carried out and predictions are compared with burst pressures and their accuracy is discussed. It is confirmed that FEM is useful for prediction of burst pressure.

A study on heat transfer and pressure drop characteristics of plain fin-tube heat exchanger using CFD analysis (CFD 해석을 통한 Plain형 핀-튜브 열교환기의 열전달 및 압력강하 특성에 관한 연구)

  • Liu, Zhao;Yoon, Jun-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.615-624
    • /
    • 2014
  • The fin-tube heat exchanger being used for industrial boiler, radiator, refrigerator has been conducted in various studies to improve it's performance. In this study, the characteristics of heat transfer and pressure drop was theoretically analyzed according to longitudinal pitch, location of vortex generator, bump phase and number of the tube surface about the plain fin-tube heat exchanger. The boundary condition for the CFD (Computational Fluid Dynamics) analysis applied with the SST (Shear Stress Transport) turbulence model assumed as the tube surface temperature of 333 K, the inlet air temperature of 423-438 K and the inlet air velocity of 1.5~2.1 m/s. The analysis results indicated that the heat transfer coefficient is not affected highly by the longitudinal pitch, and the heat transfer characteristics was more favorable when the vortex generator was located in front of the tube. Also the bump phase of the tube surface indicated that circle type was more appropriate than serrated type and triangle type in the characteristics of heat transfer and pressure drop, and the sixteen's bump phase of circle type was most favorable.