• Title/Summary/Keyword: 원형 제작

Search Result 693, Processing Time 0.027 seconds

Evaluation of Structural Performance in CFT Truss Girder with the Arch-Shaped Lower Chord (아치형상의 하현재를 갖는 CFT 트러스 거더의 구조성능 평가)

  • Chung, Chul-Hun;Song, Na-Young;Ma, Hyang-Wook;Oh, Hyun-Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4A
    • /
    • pp.315-327
    • /
    • 2009
  • In this study, the static test of CFT truss girders for different f/L ratios was conducted to determine how the ultimate strength of the CFT truss girder was affected by different f/L ratios. A total of two CFT truss girders were constructed and tested under bending condition. The length of all specimens is 20,000 mm. The CFT truss girder is a tubular truss composed of chord members made of concrete-filled circular tubes. The main parameter analyzed in the experimental study was the f/L ratio. This factor was experimentally investigated to assess their influence on ultimate strength and stiffness. The test results show that CFT truss girder has good elastic-plastic property and ductility. The presence of the f/L ratios in CFT truss girders alters its ultimate strength because of the global stiffness of the CFT truss girders. The ultimate strength of CFT truss girders increases as the f/L ratio increases. If the f/L ratio of the CFT truss girders increases twofold, the ultimate strengths increase by 80%. The CFT truss girders showed that they retained large deformation capacity, even after reaching the ultimate strength. Results of this investigation demonstrated the potential for efficiently using a CFT truss as a bridge girder.

A Re-examination the study on the Gogureoy Geomungo (고구려 거문고 연구 재검토)

  • Choi, Heon
    • (The) Research of the performance art and culture
    • /
    • no.32
    • /
    • pp.701-738
    • /
    • 2016
  • The Geomungo(거문고) is a instrument of Gogureoy(高句麗). The instrument had covered a lot of Korea, so it have become a important musical instrument in Korea. Hayasi Genjo(林謙三), Japanese scholar, had maintained his opinion that the Geomungo of Gogureoy is the Wagonghu(臥??), and the Geomungo was formed later, the record of Kimbusik, wrighter of the History of Three Kingdom(三國史記), was incredible. Lee-Hyegu refuted his hypothesis because the introduction on the Wagonghu of Japan have been inaccurate. Since then, many scholars of Korea have studed on the Geomungo of Gogureoy. But their study of the Geomungo was inclined to the topic, relation of the Geomungo and the Wagonghu, or the Wagonghu, the origin of the Geomungo. And They have thought that the record of Kimbusik's was truth. Kimbusik had recorded that Wangsanak(王山岳) had made the Geomungo from the Chilheoyn-Geum(七絃琴, Seven stringed Zither. 古琴). But the Geomungo was different from Geum(琴), but similar to Wagonghu. Many ancient tomb have been unearthed in the old land of Gogureoy, and the were many tomb painting of Gogureoy Geomungo. They were many different style, the form, the size, the number of strings and the position of the musician. So I think that many various type of the Geomungo had been exsited in Gogureoy they had become a prestyle of the Geomungo. The Geomungo was originated from the Wagonghu, its form was similar to the Geomungo. The many scholars considered that it is truth, the Wagonghu was handed down from China, and was spreded to Japan. But there were the Wagonghu in the early Joseon(古朝鮮), The song of the early Joseon, Gongmudohaga(公無渡河歌). The song was accompanied by the Wagonghu. We can read off, at the Song, the Wagonghu had exsisted in the early Joseon. So I think cautiously on that point, the Wagonghu of the Early Joseon was old than that of China, and thd Geomungo of Gogureoy was originated from the Wagonghu of the Early Joseon.

Application of Science for Interpreting Archaeological Materials(III) Characterization of Some Western Asia Glass Vessels from South Mound of Hwangnamdaechong (고고자료의 자연과학 응용(III) 황남대총(남분)의 일부 서역계 유리제품에 대한 과학적 특성 분류)

  • Kang, Hyung Tae;Cho, Nam Chul
    • Korean Journal of Heritage: History & Science
    • /
    • v.41 no.1
    • /
    • pp.5-19
    • /
    • 2008
  • Thirty six samples of Western asia glass vessel shards which were excavated from South Mound of Hwangnamdaechong were each measured for thickness, pore size and specific gravity and analyzed for ten major compositions and thirteen trace elements. The glass samples with colorless, greenish blue and dark purple blue were well classified by principal component analysis(PCA). All glass shards of Hwangnamdaechong belonged to Soda glass system ($Na_2O-CaO-SiO_2$) which have the range of 14~17% $Na_2O$ and 5~6% CaO. The corelation coefficients of (MgO, $K_2O$) and (MnO, CuO) showed above 0.90. The concentrations of thirteen trace elements apparently differentiated from colorless, greenish blue and dark blue glasses. We found that thirteen trace elements were very important indices for studying raw material of glass and the origin of glass making. Colorless glass : The specific gravity is $1.50{\pm}0.04$. Circle or oval circle pores are observed with regular direction in internal zone and the longest one is about 0.35 mm. The raw material of sodium must be the plant ash because sodium glasses contain HCLA(High CaO, Low $Al_2O_3$) and HMK(high MgO, high $K_2O$) and suggested to Sasanian glass. The total amount of coloring agent of colorless glass is below 1 % which is too small to attribute to the color. Greenish blue glass : The specific gravity is $1.58{\pm}0.04$. The fine pores which are 0.1~0.2mm are dispersed in internal zone. Sodium glasses are distributed to HCLA and HMK. Therefore the greenish blue glass also have used plant ash for raw material of sodium with the same as colorless glass. It was also suggested to the glass of Sasanian. The total amount of coloring agent of greenish blue glass is about 4% under the influence of working MnO, $Fe_2O_3$ and CuO. Dark purple blue glass : The specific gravity is $1.48{\pm}0.19$. There are rarely pores in internal zone. They are distributed to HCLA and LMK(Low MgO, Low $K_2O$) and suggested to Roman glass. The raw material of sodium is estimated to natron. The total amount of coloring agents of greenish blue is about 3% by $Fe_2O_3$ and CuO. These studies for western asia glass shards from South Mound of Hwangnamdaechong could be used in the future as the standard data which could be compared with those of other several graves in Korea and dispersed in foreign areas.

Dietary Administration of Probiotics, Bacillus sp. IS-2, Enhance the Innate Immune Response and Disease Resistance of Paralichthys olivaceus against Streptococcus iniae (Probiotics를 양식넙치에 투여시 Streptococcus iniae에 대한 면역반응 및 병저항성)

  • Jang, Ik-Soo;Kim, Dong-Hwi;Heo, Moon-Soo
    • Korean Journal of Microbiology
    • /
    • v.49 no.2
    • /
    • pp.172-178
    • /
    • 2013
  • The strains were added to the feed in the concentration of $10^3$, $10^5$, and $10^7$ CFU/kg and 2% of fishes were given the feed twice a day (8 AM and 5 PM) for 12 weeks. In result of the nonspecific immune response study to examine Respiratory burst activity, Lysozyme activity and Phagocytosis activity every two weeks until the end of the study, all test samples showed greater activities than control samples and improved immune activity with Bacillus sp. IS-2. The mortality test performed by artificial infection using Streptococcus iniae, a pathogenic bacterium, after the completion of this study also showed over 55% greater survival rate in all test samples. In result of performing PCR using the universal primer to verify that the probiotic stays in the intestines of the fishes, all test samples showed PCR product of 1,465 bp. Based on the above findings, it was concluded that Bacillus sp. IS-2 in the feed improved farmed flatfish's immune system and resistance against diseases as the probiotics. Also, the physiological indicators discovered by this study would be useful for identifying the mechanisms of probiotics.

A Study on Dosimetry for Small Fields of Photon Beam (광자선 소조사면의 선량 측정에 관한 연구)

  • 강위생;하성환;박찬일
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.57-68
    • /
    • 1994
  • Purpose : The purposes are to discuss the reason to measure dose distributions of circular small fields for stereotactic radiosurgery based on medical linear accelerator, finding of beam axis, and considering points on dosimetry using home-made small water phantom, and to report dosimetric results of 10MV X-ray of Clinac-18, like as TMR, OAR and field size factor required for treatment planning. Method and material : Dose-response linearity and dose-rate dependence of a p-type silicon (Si) diode, of which size and sensitivity are proper for small field dosimetry, are determined by means of measurement. Two water tanks being same in shape and size, with internal dimension, 30${\times}$30${\times}$30cm$^3$ were home-made with acrylic plates and connected by a hose. One of them a used as a water phantom and the other as a device to control depth of the Si detector in the phantom. Two orthogonal dose profiles at a specified depth were used to determine beam axis. TMR's of 4 circular cones, 10, 20, 30 and 40mm at 100cm SAD were measured, and OAR's of them were measured at 4 depths, d$\sub$max/, 6, 10, 15cm at 100cm SCD. Field size factor (FSF) defined by the ratio of D$\sub$max/ of a given cone at SAD to MU were also measured. Result : The dose-response linearity of the Si detector was almost perfect. Its sensitivity decreased with increasing dose rate but stable for high dose rate like as 100MU/min and higher even though dose out of field could be a little bit overestimated because of low dose rate. Method determining beam axis by two orthogonal profiles was simple and gave 0.05mm accuracy. Adjustment of depth of the detector in a water phantom by insertion and remove of some acryl pates under an auxiliary water tank was also simple and accurate. TMR, OAR and FSF measured by Si detector were sufficiently accurate for application to treatment planning of linac-based stereotactic radiosurgery. OAR in field was nearly independent of depth. Conclusion : The Si detector was appropriate for dosimetry of small circular fields for linac-based stereotactic radiosurgery. The beam axis could be determined by two orthogonal dose profiles. The adjustment of depth of the detector in water was possible by addition or removal of some acryl plates under the auxiliary water tank and simple. TMR, OAR and FSF were accurate enough to apply to stereotactic radiosurgery planning. OAR data at one depth are sufficient for radiosurgery planning.

  • PDF

Development of a Ranging Inspection Technique in a Sodium-cooled Fast Reactor Using a Plate-type Ultrasonic Waveguide Sensor (판형 웨이브가이드 초음파 센서를 이용한 소듐냉각고속로 원격주사 검사기법 개발)

  • Kim, Hoe Woong;Kim, Sang Hwal;Han, Jae Won;Joo, Young Sang;Park, Chang Gyu;Kim, Jong Bum
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.1
    • /
    • pp.48-57
    • /
    • 2015
  • In a sodium-cooled fast reactor, which is a Generation-IV reactor, refueling is conducted by rotating, but not opening, the reactor head to prevent a reaction between the sodium, water and air. Therefore, an inspection technique that checks for the presence of any obstacles between the reactor core and the upper internal structure, which could disturb the rotation of the reactor head, is essential prior to the refueling of a sodium-cooled fast reactor. To this end, an ultrasound-based inspection technique should be employed because the opacity of the sodium prevents conventional optical inspection techniques from being applied to the monitoring of obstacles. In this study, a ranging inspection technique using a plate-type ultrasonic waveguide sensor was developed to monitor the presence of any obstacles between the reactor core and the upper internal structure in the opaque sodium. Because the waveguide sensor installs an ultrasonic transducer in a relatively cold region and transmits the ultrasonic waves into the hot radioactive liquid sodium through a long waveguide, it offers better reliability and is less susceptible to thermal or radiation damage. A 10 m horizontal beam waveguide sensor capable of radiating an ultrasonic wave horizontally was developed, and beam profile measurements and basic experiments were carried out to investigate the characteristics of the developed sensor. The beam width and propagation distance of the ultrasonic wave radiated from the sensor were assessed based on the experimental results. Finally, a feasibility test using cylindrical targets (corresponding to the shape of possible obstacles) was also conducted to evaluate the applicability of the developed ranging inspection technique to actual applications.

A Development of Tapered Metallic Microneedle Array for Bio-medical Application (생체의학에 적용 가능한 테이퍼형태의 금속성 마이코로니들 어레이의 개발)

  • Che Woo Seong;Lee Jeong-Bong;Kim Kabseog;Kim Kyunghwan;Jin Byung-Uk
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.2 s.31
    • /
    • pp.59-66
    • /
    • 2004
  • This paper presents a novel fabrication process for a tapered hollow metallic microneedle array using backside exposure of SU-8, and analytic solutions of critical buckling of a tapered hollow microneedle. An SU-8 meta was formed on a Pyrex glass substrate and another SU-8 layer, which was spun on top of the SU-8 mesa, was exposed through the backside of the glass substrate. An array of SU-8 tapered pillar structures. with angles in the range of $3.1^{\circ}{\sim}5^{\circ}$ was formed on top of the SU-8 mesa. Conformal electrodeposition of metal was carried out followed by a mechanical polishing using a pianarizing polymeric layer. All organic layers were then removed to create a metallic hollow microneedle array with a fluidic reservoir on the backside. Both $200{\mu}m\;and\;400{\mu}m$ tall, 10 by 10 arrays of metallic microneedles with inner diameters of the tip in the range of $33.6{\sim}101\;{\mu}m$ and wall thickness of $10{\mu}m\;-\;20{\mu}m$ were fabricated. Analytic solutions of the critical buckling of arbitrary-angled truncated cone-shaped columns are also presented. It was found that a single $400{\mu}m$ tall hollow cylindrical microneedle made of electroplated nickel with a wall thickness of $20{\mu}m$, a tapered angle of $3.08^{\circ}$ and a tip inner diameter of $33.6{\mu}m$ has a critical buckling force of 1.8 N. This analytic solution can be used for square or rectangular cross-sectioned column structures with proper modifications.

  • PDF

The characteristic of InGaN/GaN MQW LED by different diameter in selective area growth method (선택성장영역 크기에 따른 InGaN/GaN 다중양자우물 청색 MOCVD-발광다이오드 소자의 특성)

  • Bae, Seon-Min;Jeon, Hun-Soo;Lee, Gang-Seok;Jung, Se-Gyo;Yoon, Wi-Il;Kim, Kyoung-Hwa;Yang, Min;Yi, Sam-Nyung;Ahn, Hyung-Soo;Kim, Suck-Whan;Yu, Young-Moon;Ha, Hong-Ju
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.1
    • /
    • pp.5-10
    • /
    • 2012
  • In general, the fabrications of the LEDs with mesa structure are performed grown by MOCVD method. In order to etch and separate each chips, the LEDs are passed the RIE and scribing processes. The RIE process using plasma dry etching occur some problems such as defects, dislocations and the formation of dangling bond in surface result in decline of device characteristic. The SAG method has attracted considerable interest for the growth of high quality GaN epi layer on the sapphire substrate. In this paper, the SAG method was introduced for simplification and fabrication of the high quality epi layer. And we report that the size of selective area do not affect the characteristics of original LED. The diameter of SAG circle patterns were choose as 2500, 1000, 350, and 200 ${\mu}m$. The SAG-LEDs were measured to obtain the device characteristics using by SEM, EL and I-V. The main emission peaks of 2500, 1000, 350, and 200 ${\mu}m$ were 485, 480, 450, and 445 nm respectively. The chips of 350, 200 ${\mu}m$ diameter were observed non-uniform surface and resistance was higher than original LED, however, the chips of 2500, 1000 ${\mu}m$ diameter had uniform surface and current-voltage characteristics were better than small sizes. Therefore, we suggest that the suitable diameter which do not affect the characteristic of original LED is more than 1000 ${\mu}m$.

Feasibility Study of Vertical Multileaf Collimator for Determination of Irradiation Size (수직형 다엽 콜리메이터의 방사선 조사면 크기 결정을 통한 유용성 연구)

  • Lee, Chang-Yeol;Son, Ki-Hong;Shin, Sang-Hun;Park, Seung-Woo;Lee, Dong-Han;Jung, Hai-Jo;Choi, Mun-Sik;Oh, Won-Young;Kim, Kum-Bae;Yang, Gwang-Mo;Ji, Young-Hoon
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.3-11
    • /
    • 2011
  • The purpose of this study was to evaluate feasibility of Vertical Multileaf Collimator for determination of irradiation size using Vertical Multileaf Collimator and lead block to determine 4 different irradiation shape in case of Co-60 gamma-ray and 6 MV X-ray. We chose ion chamber, glass dosimeter and EBT chromic film to compare with Vertical Multileaf Collimator results and lead block results. In case of Co-60 gamma-ray and 6 MV X-ray, the central axis point dose normalized at reference field of lead block with ion chamber results for Vertical Multileaf Collimator were estimated higher than lead block about 5.1%, 4.2%. In case of Co-60 gamma-ray, the central axis point dose normalized at reference field of lead block with glass dosimeter results for Vertical Multileaf Collimator were estimated higher than lead block about 2.2%, 7.8%, 7.2%, 4.0% for reference, circle, triangle, cross field, respectively. In case of 6 MV X-ray, the central axis point dose normalized at reference field of lead block with glass dosimeter results for Vertical Multileaf Collimator were estimated higher than lead block about 6.7%, 6.2%, 3.8%, 6.2% for reference, circle, triangle, cross field, respectively. The results of EBT chromic film, Vertical Multileaf Collimator of penumbra size for all irradiation shape was smaller than lead block of those size that 2.0~3.5 mm for Co-60 gamma-ray, 0.5~1.0 mm for 6 MV X-ray. The results from this study, radiation treatment volume that results in shielding block can be minimized. In addition, during radiation treatment for 2, 3-dimensional radiation therapy using a Vertical Multileaf Collimator of this survey can be used to determine variety of irradiation fields.

Iconography and Symbols of the Gwandeokjeong Pavilion Murals in Jeju (제주 관덕정(觀德亭) 벽화의 도상과 표상)

  • Kang, Yeongju
    • Korean Journal of Heritage: History & Science
    • /
    • v.53 no.3
    • /
    • pp.258-277
    • /
    • 2020
  • The purpose of this paper is to examine the paintings and symbols of the Jeju Guandeokjeong murals, Treasure No. 322. Gwandeokjeong Pavilion in Jeju is one of the oldest buildings in Jeju and was built in 1448 during the reign of King Sejong (世宗) of the Joseon Dynasty to serve as a training ground for soldiers. Unlike Gwandeokjeong Pavilions in other regions, Jeju's Gwandeokjeong Pavilion has a long history and is of cultural value due to its beautiful architecture. In addition, it contains various murals which are a further source of attention. There are four murals on the front and back of the two Lintels on the left and right sides of the building. Their contents include of 『The Three Kingdoms (三國志)』 and and on the back. Towards the right, is depicted, with on the back. Based on a replica of the murals from 1976, the plan, style, and age of the Gwandeokjeong Pavilion murals have been studied, together with their meanings. The contents of the mural are broadly divided into five parts, which are identified by the tacit signatures atop the screen, which provide such details as the painting titles. The paintings on the left and right sides of the center appear to inspire the spirit of the military's commerce in order to boost soldiers' morale, protect the country, and protect the people in line with the purpose of Gwandeokjeong Pavilion. The following and figuratively depict guidelines for the behavior and mindset of officials. In particular, is a painting concerned with concepts of longevity and an auspicious (吉祥), which shows how court paintings became popular as folk paintings at that time. The paintings of tangerines and other specialties of Jeju Island, the ritual paintings of Jeokbyeokdaejeon, and the expressions of Mt. Halla (漢拏山) and Oreum (오름) indicate the existence of Jeju artists that belonged to the Jeju government office at that time. The five themes and styles of the murals also show that the murals of Gwandeokjeong Pavilion were produced in the late 19th and early 20th centuries.