• Title/Summary/Keyword: 원형 링

Search Result 172, Processing Time 0.028 seconds

Detection Models and Response Techniques of Fake Advertising Phishing Websites (가짜 광고성 피싱 사이트 탐지 모델 및 대응 기술)

  • Eunbeen Lee;Jeongeun Cho;Wonhyung Park
    • Convergence Security Journal
    • /
    • v.23 no.3
    • /
    • pp.29-36
    • /
    • 2023
  • With the recent surge in exposure to fake advertising phishing sites in search engines, the damage caused by poor search quality and personal information leakage is increasing. In particular, the seriousness of the problem is worsening faster as the possibility of automating the creation of advertising phishing sites through tools such as ChatGPT increases. In this paper, the source code of fake advertising phishing sites was statically analyzed to derive structural commonalities, and among them, a detection crawler that filters sites step by step based on foreign domains and redirection was developed to confirm that fake advertising posts were finally detected. In addition, we demonstrate the need for new guide lines by verifying that the redirection page of fake advertising sites is divided into three types and returns different sites according to each situation. Furthermore, we propose new detection guidelines for fake advertising phishing sites that cannot be detected by existing detection methods.

광학 분석 시스템용 수.발광 소자 집적 모듈 개발

  • Song, Hong-Ju;Lee, Jun-Ho;Park, Jong-Hwan;Han, Cheol-Gu;Park, Jeong-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.311-312
    • /
    • 2012
  • 본 발표에서는 광학적 분석 시스템에 적용 가능한 발광소자(광원)과 수광소자(광센서)를 집적화시키는 모듈(수 발광 집적모듈) 기술을 제시하고자 한다. 이러한 수-발광 집적모듈은 다양한 응용 분야에 적용 될 수 있다. 예를 들어, 광신호 감지를 위한 광통신용 송-수신 모듈(optical communication), 의료/진단 분야에서 단백질/DNA/박테리아 등의 검출 및 분석에 관한 바이오 센서(bio-sensor), 그리고 대기(가스)/수질 모니터링에 관한 환경센서 등 매우 광범위한 분야에 해당되는 요소 기술이라 할 수 있다. 특히, 이들 분야들 중 바이오 물질을 분석하고 검출하는 광학적 바이오 센서 기술은 높은 경제적 가치와 산업적 성장 잠재력으로 인해 오랫동안 활발한 연구가 진행되어 오고 있다. 이러한 광학적 바이오 센서에서 가장 범용적인 방법 중 하나가 항온-항체 면역반응을 기반으로 하는 형광 검출(fluorescence detection) 기법이다. 이러한 시스템은 전체적으로 광원, 광학계, 그리고 센서로 구성되는데 기존에 일반적으로 사용되고 있는 형광 현미경의 경우는 민감도가 우수하다는 장점은 있으나 상당히 고가이고 부피가 크며 복잡한 광학구성으로 이루어져 있다는 한계점을 가지고 있다. 이러한 맥락에서 고민감도를 확보하면서 휴대성, 고속처리, 저가 등의 특성을 가진 시스템에 대한 요구가 갈수록 증가하고 있다. 이를 해결하기 위한 핵심기술 중의 하나가 수-발광 부분을 집적화 시키는 기술이라 할 수 있다. 본 연구에서는 바이오 센서 기술의 하나로서 형광을 측정하여 혈액내의 진단 지표인자를 검출할 수 있는 휴대용 혈액진단기기에 적용되는 소형 수 발광 집적 모듈을 개발하였다. 혈액내의 검출 성분의 양에 따라 형광의 세기가 변화하게 됨으로써 정량적인 검출이 가능한 원리이다. 모듈의 구조는 크게 광원(발광소자), 광학계, 그리고 광센서(수광소자) 세 영역으로 나누어 진다. 광원은 635 nm 적색 레이저다이오드로서 형광체(Alexa Fluor 647/발광파장: 668 nm)를 여기 시키는 기능을 하며 장착된 볼렌즈 의해 샘플의 형광체 영역으로 집광된다. 광학계는 크게 시준렌즈(collimating lens)와 광학필터로 구성됨으로써 샘플로부터 발생되는 광을 적절하게 수광소자로 전달하는 기능을 하게 된다. 여기서 광학필터의 경우는 기본적으로 Distributed Bragg's Reflector(DBR) 구조로써 실리콘(Si) 포토다이오드 상부에 모노리식(monolithic)하게 형성되며 검출 샘플로부터 진행되는 레이저 광(잡음의 주원인)은 차단하고 형광(광신호)만 통과 시키는 기능을 하게 된다. 따라서 신호 대 잡음비(S/N ratio)를 향상시키기 위해서는 정밀한 광 필터링 기능이 요구됨으로써 박막의 세밀한 공정 조건과 구조적-광학적 특성 분석이 수행되었다. 마지막으로 포토다이오드 소자는 일반적인 구조 이외에 중앙에 원형 구멍이 형성된 특별한 구조가 적용된다. 이것은 포토다이오드 구조에 변화를 줌으로써 모듈 구조를 효율적으로 응용할 수 있다는 의미를 갖는다. 또한 포토다이오드의 전기적-광학적 측정 분석을 통해 잡음 및 감도 특성이 세부적으로 조사되며 형광신호를 효과적으로 측정할 수 있음을 확인하였다. 최종적으로 제작된 모듈은 약 $1{\times}1{\times}1cm^3$ 내외 정도의 크기를 갖는다. 요약하자면 본 발표에서는 광학적 바이오센서에 적용할 수 있는 소형 수-발광 소자 집적모듈을 소개한다. 전체 모듈 설계는 최소한의 부피를 가짐과 동시에 측정의 정밀성을 향상시키는데 초점을 맞추어 진행하였다. 세부요소인 광학필터와 포트다이오드의 경우 잡음 및 민감도에 미치는 중요성 때문에 세밀한 공정 및 특성분석이 수행되었다. 결론적으로 독자적인 설계 및 공정을 통해 휴대성 및 정밀성 등의 목적에 부합한 경쟁력 있는 수-발광 소자 집적모듈 제작 기술을 확보하였다.

  • PDF

Construct of uncontaminated underground reservoir test facility (청정지하저수지 시험시설의 구축)

  • Lee, Chang Seob;Park, Nam Sik;Jeong, Jae Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.328-328
    • /
    • 2016
  • 우리나라는 생활용수의 대부분을 지표수에 의존하고 있는 실정이다. 그러나 지표수는 가뭄과 같은 기상변화, 수질사고 등으로 물 공급의 안정성에 문제가 되기도 한다. 향후 기후변화는 가뭄의 빈도와 강도를 증대시킬 것으로 파악되므로 수질 및 수량의 문제를 더욱 악화시킬 것으로 예상된다. 이러한 문제점을 해결하기 위해 지표수를 대수층 내에 인공적으로 함양한 뒤 대수층의 자연정화 기능에 의해 여과된 양질의 청정원수를 생산하는 기술을 본 연구에서 현장에 실증 적용하는 시설을 구축하였다. 이러한 기술은 기존의 지하 대수층을 이용하는 강변여과 등이 갖는 장점을 취하고 단점을 보완하였으며 친환경적이며 지속가능한 용수공급뿐만 아니라 청정 원수 확보를 통해 정수처리비용을 절감, 장기간의 가뭄이나 지표수 수질사고 시에 비상용수 공급 등 기존 취수원들과 달리 많은 장점을 갖고 있는 대규모 청정지하저수지 시험시설이다. 청정 지하저수지 기술이 주로 적용되는 지역은 해안지역 또는 하구 델타지역을 대상으로 한다. 해안 또는 델타지역은 해수침투로 인하여 염지하수가 부존되어 있기 때문에 지하수자원 활용에 매우 제한적이다. 따라서 지표수(담수)를 전처리하여 대수층에 인공적으로 함양을 하여 염지하수 대수층 안에 담지하수(담수체)를 형성할 수 있다. 이는 염수와 담수의 밀도차에 의해 희석되지 않는 특성을 이용한 기술이다. 청정 지하저수지 시험시설은 크게 지표수 취수시설, 전처리시설, 주입정, 양수정, 운영시스템으로 나눌 수 있다. 주입정 및 양수정은 원형의 형태로 지하저수지 조성범위 중심부에 9개의 주입정과 외각에 8개의 양수정을 설치하였다. 시험시설의 운영 과정은 하천수를 취수하여 전처리시설에서 탁도를 제거한 후, 피압대수층 염지하수에 동력으로 주입을 한다. 이때 기존에 부존되어 있던 염지하수를 밀어내고 담수체 지하수 형성을 유도한다. 일정기간 주입을 통해 목표 담수체를 만들어 내면 양수정에서 담수를 취수하되, 대수층의 모래자갈층을 일정거리 이동하여 취수하는 방식이다. 즉, 하천수를 대수층에 함양하고, 일정거리를 이동하여 취수하는 ASTR 방식의 대체수자원 확보 기술이다. 시험시설은 통합운영센터를 통해 원격감시 및 각종 제어/계측을 실시하며, 모니터링된 자료는 운영시스템에서 관리한다. 본 연구시설에서는 대수층 주입, 관정폐색, 미생물/지화학 수질반응, 지하수모니터링, 지반변형 등이 주요 핵심 연구를 진행하고 있도록 시설을 구성하였다. 본 시험시설은 2015년 8월 착공하여 2016년 4월에 완공 예정이며, 2016년 3월부터 주입을 시작하여 6개월간 피압대수층에 주입을 실시하고 이후부터 주입과 양수를 병행할 계획이다.

  • PDF

Effects of Various Ventilation Systems on the Carbon Dioxide Concentration and Fruiting Body Formation of King Oyster Mushroom (Pleurotus eryngii) Grown in Culture Bottles (새송이버섯 병재배에서 환기방법이 이산화탄소 농도 및 자실체형성에 미치는 영향)

  • Lee, Hyun-Uk;Ahn, Mi-Jeong;Lee, Shin-Woo;Lee, Cheol-Ho
    • Journal of Life Science
    • /
    • v.17 no.1 s.81
    • /
    • pp.82-90
    • /
    • 2007
  • In an attempt to establish the appropriate ventilation device for the bottle culture of king oyster mushroom (Pleurotus eryngii), we investigated carbon dioxide concentration and fruiting body formation according to the various ventilation systems within the mushroom house. In addition to, the efficiency of air circulation and growth rate as well as the appearance of physiologically abnormal phenotypes during their growth stage were also evaluated. four different ventilation devices, parallel-pressure type, positive-pressure type, negative-pressure type, and positive- and negative-pressure type were applied in this study. The positive-and negative-pressure type showed the highest efficiency of air circulation as $CO_2$ concentration was 800 ppm and the level of air current was relatively low compared to the other types (the $CO_2$ concentration of parallel-pressure type was 1,400 ppm). Moreover, the stipe length, the cap diameter, yield, and general quality grown in positive- and negative type ventilation device were also better than in the other three devices though it took slightly longer period for harvesting (18.4 days) than the others (17.6, 17.9 and 18.3 days). The appearance of physiologically abnormal phenotypes such as fruiting body lump, soft rot, and brown rot were significantly decreased in positive-and negative type compared to other types, while the appearance rates were not much different for other symptoms of bacterial ooze, stipe limb and stipe bumpy. In summary, we propose that the optimal ventilation system for the bottle culture of king oyster mushroom is positive- and negative type, and this device is expected to increase the total quality as well as yield all year around.

Quantitative Conductivity Estimation Error due to Statistical Noise in Complex $B_1{^+}$ Map (정량적 도전율측정의 오차와 $B_1{^+}$ map의 노이즈에 관한 분석)

  • Shin, Jaewook;Lee, Joonsung;Kim, Min-Oh;Choi, Narae;Seo, Jin Keun;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.4
    • /
    • pp.303-313
    • /
    • 2014
  • Purpose : In-vivo conductivity reconstruction using transmit field ($B_1{^+}$) information of MRI was proposed. We assessed the accuracy of conductivity reconstruction in the presence of statistical noise in complex $B_1{^+}$ map and provided a parametric model of the conductivity-to-noise ratio value. Materials and Methods: The $B_1{^+}$ distribution was simulated for a cylindrical phantom model. By adding complex Gaussian noise to the simulated $B_1{^+}$ map, quantitative conductivity estimation error was evaluated. The quantitative evaluation process was repeated over several different parameters such as Larmor frequency, object radius and SNR of $B_1{^+}$ map. A parametric model for the conductivity-to-noise ratio was developed according to these various parameters. Results: According to the simulation results, conductivity estimation is more sensitive to statistical noise in $B_1{^+}$ phase than to noise in $B_1{^+}$ magnitude. The conductivity estimate of the object of interest does not depend on the external object surrounding it. The conductivity-to-noise ratio is proportional to the signal-to-noise ratio of the $B_1{^+}$ map, Larmor frequency, the conductivity value itself and the number of averaged pixels. To estimate accurate conductivity value of the targeted tissue, SNR of $B_1{^+}$ map and adequate filtering size have to be taken into account for conductivity reconstruction process. In addition, the simulation result was verified at 3T conventional MRI scanner. Conclusion: Through all these relationships, quantitative conductivity estimation error due to statistical noise in $B_1{^+}$ map is modeled. By using this model, further issues regarding filtering and reconstruction algorithms can be investigated for MREPT.

Lifejcket-Integrated Antenna for Search and Rescue System (탐색 및 구조 시스템용 구명조끼 내장형 안테나)

  • Lim, Ji-Hun;Yang, Gyu-Sik;Jung, Sung-Hun;Park, Dong-Kook
    • Journal of Navigation and Port Research
    • /
    • v.38 no.4
    • /
    • pp.367-371
    • /
    • 2014
  • When the crew or passengers fall into the water due to marine accident of vessel, it is very important to rescue them quickly. In the case of marine accidents, most people in distress have been wearing a lifejacket, so if the GPS and Cospas-Sarsat communication module will be integrated within the lifejacket, it is easy to rescue them. In this paper, development of the dual band lifejacket-integrated antenna for GPS and Cospas-Sarsat communication is discussed. The antenna with the FR-4 substrate of 0.2mm thickness for flexibility was designed that it can be fitted close to the shoulder of the life jacket and operate at 1.575GHz and 406MHz. The GPS communication antenna was implemented with a ring-slot antenna having a circular polarized characteristic and a meander type linear polarized antenna is used as Cospas-Sarsat communication. The two antennas are fed by a single microstrip line and an open stub is used to minimize the mutual interference between the two antennas. The performance of the fabricated antenna attached to the life vest is confirmed by the measurement of the return loss at GPS and Cospas-Sarsat frequency bands.

Comparative Study on the Applicability of Point Estimate Methods in Combination with Numerical Analysis for the Probabilistic Reliability Assessment of Underground Structures (수치해석과 연계한 지하구조물의 확률론적 신뢰성 평가를 위한 점추정법의 적용성에 관한 비교 연구)

  • Park, Do-Hyun;Kim, Hyung-Mok;Ryu, Dong-Woo;Choi, Byung-Hee;Han, Kong-Chang
    • Tunnel and Underground Space
    • /
    • v.22 no.2
    • /
    • pp.86-92
    • /
    • 2012
  • Point estimate method has a less accuracy than Monte Carlo simulation that is usually considered as an exact probabilistic method, but this method still remains popular in probability-based reliability assessment in geotechnical and rock engineering, because it significantly reduce the number of sampling points and produces the statistical moments of a performance function in a reasonable accuracy. In the present study, we investigated the accuracy and applicability of point estimate methods proposed by Rosenblueth and Zhou & Nowak by comparing the results of these two methods with those of Monte Carlo simulations. The comparison was carried out for the problem of a lined circular tunnel in an elastic medium where an closed-form analytical solution is given. The comparison results showed that despite the non-linearity of the analytical solution, the statistical moments calculated by the point estimate methods and the Monte Carlo simulations agreed well with an average error of roughly 1-2%. This average error demonstrates the applicability of the two point estimate methods for the probabilistic reliability assessment of underground structures in combination with numerical analysis.

A Study on Appropriate Traffic Volume Calculation for Revitalizing Roundabout Installation (국내 회전교차로 활성화를 위한 적정교통량 산정에 관한 연구)

  • Lee, Dongmin;You, Jungho
    • Journal of Korean Society of Transportation
    • /
    • v.31 no.6
    • /
    • pp.43-52
    • /
    • 2013
  • A roundabout is a form of circular intersection in which traffic travels counterclockwise around a central island and in which entering traffic must yield to circulating traffic. It has been known that a roundabout provides substantially better operational and safety characteristics than other intersections including rotaries. Recently, a roundabout has started to be constructed due to its efficiency, safety, and other advantages of a roundabout comparing other intersections in Korea. However, there has been no guideline to be used to decide appropriate intersection types considering given conditions of the intersections. To solve this problem, the guideline with traffic volume to choose the suitable intersection types was developed based on analysis results using the SIDRA software which is generally used to analyze operational effects of roundabouts. It was found that a roundabout is more efficient than signalized intersection when the traffic volume is between 125 and 450 veh/h on one lane road and roundabout is not recommended when there are more than 30% left turn traffic. The optimal traffic volume provided in this research will be usefully used in planing and designing roundabouts in Korea.

Electron Beam Welding on Module-typed Turbine Diaphragm (모듈 형 터빈 다이아프람의 전자빔 용접 기술)

  • Kim, Yong-Jai;Shim, Duck-Nam;Jung, In-Chul
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.107-107
    • /
    • 2009
  • 모듈 형 터빈 다이아프람은, 아우터 링(outer ring), 스팀 패스(steam path)와 이너 웹(inner web)의 원형 형상을 갖는 세 부분을 조립하여 원주 방향의 용접 조인트를 형성하는 기존의 다이아프람 형태가 아니라, 아우터 슈라우드(outer shroud), 베인(vane)과 이너 슈라우드(inner shroud)의 세 부분이 하나의 모듈을 이루고 이러한 모듈을 원주 방향으로 조립하여 방사 방향의 조인트를 형성한다. 전자빔 용접은 이와 같은 방사 방향의 조인트를 수직으로 가로지르는 용접 궤적을 따라 진행되며, 용접 패스에 따라 형성되는 용융 비드의 단면적만큼 인접하는 두 모듈을 접합시킨다. 이 경우 용융 비드의 단면적과 형상은 두 모듈의 결합 강도를 결정하는 중요한 요소가 되어, 제작 시 다이아프람의 크기와 두께에 따라 용입 깊이와 평균 단면 비드 폭을 규정하고 있다. 본 연구에서는 용입 깊이와 단면 비드 폭의 요구 조건을 만족하면서 결함이 없는 건전한 용접부를 얻을 수 있는 최적 용접 조건을 도출하는데 그 목적이 있다. 이를 위해 플레이트 시편과 모듈 시편을 사용한 기초 실험과 유사 시제품(semi-mockup) 실험을 실시하였다. 플레이트 기초 실험을 통해 전자빔 주요 변수인 빔 전류, 초점 위치, 용접 속도, 빔 진동 폭 변화에 따른 용융 비드 형상 변화를 관찰하였고, 빔 전류가 용입 깊이에 가장 큰 영향을 주는 인자임을 확인하여 요구 용입 깊이 별 적정 빔 전류 값을 설정하였다. 용접 속도는 생산성 측면에서 균열이 발생하지 않는 범위에서 가능하면 가장 큰 값을 사용하였고, 빔 진동 폭은 초점 위치와 함께 단면 비드 형상 결정에 많은 영향을 주는 인자로 확인되어 균열이 없는 가장 이상적인 단면 비드 형상인 완만한 쐐기 형태가 되도록 설정하였다. 이 후 실제 제품 폭과 용접 패스를 갖는 블록 모듈 실험을 통해 설정 용접 변수의 적용성과 균열 발생 여부를 확인하였고, 이 때 적용 제품 폭이 30 mm 이하이며 요구 용입 깊이가 50 mm 이상의 경우에서 비드 중앙부 균열이 발생함을 관찰하였다. 따라서 해당 영역의 제품에는 균열 저항성이 높도록 용접 속도와 빔 진동 폭을 줄여 최적 용접 변수를 새롭게 설정하였으며, 이를 유사 시제품 실험에 적용하여 최종적으로 용접 변수 안정성을 검증하였다. 이러한 실험을 통해 확인된 최적 용접 조건을 실 제품 제작에 적용하여 모듈 형 터빈 다이아프람 전자빔 용접 제작을 성공적으로 완료할 수 있었다.

  • PDF

A study of ubiquitous-RTLS system for worker safety (작업자 안전관리를 위한 유비쿼터스-실시간 위치추적시스템 연구)

  • Kim, Young-Baig
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.1C
    • /
    • pp.1-7
    • /
    • 2012
  • At the industrial work site, the manufacturing process is being automated to improve work efficiency. However, it is often difficult to automate the entire manufacturing process, and there are spaces in which workers there are constantly exposed to danger. To protect such workers from the danger, this paper studied a worker safety management system for the industrial work site which uses a location recognition system and which is based on the Ubiquitous-Wireless Sensor Network (U-WSN). Using wireless signals, the distance between two devices can be measured and the location of a worker can be calculated using triangularization in 3-D. But at the industrial work sites where there are a lot of steel and structures, errors occur due to signal reflection and multi-path, etc., which makes it difficult to get the accurate location. To address this problem the following was done: first, a circular polarization patch antenna appropriate to the work site was used to reduce the degree of error that may occur from the antenna emission pattern and the particular Line of Sight (LOS); second, a 3-D localization technique and a filtering algorithm were used to improve the accuracy of location determination. The developed system was tested by using it on a wharf crane to validate its accuracy and effectiveness. The proposed location recognition system is expected to contribute greatly in ensuring the safety of workers at industrial work sites.